Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flow Visualization in Evaporating Liquid Drops and Measurement of Dynamic Contact Angles and Spreading Rate

A new hybrid optical system, consisting of reflection-refracted shadowgraphy and top-view photography, is used to visualize flow phenomena and simultaneously measure the spreading and instant dynamic contact angle in a volatile-liquid drop on a nontransparent substrate. Thermocapillary convection in the drop, induced by evaporation, and the drop real-time profile data are synchronously recorded by video recording systems. Experimental results obtained from this unique technique clearly reveal that thermocapillary convection strongly affects the spreading process and the characteristics of dynamic contact angle of the drop. Comprehensive information of a sessile drop, including the local contact angle along the periphery, the instability of the three-phase contact line, and the deformation of the drop shape is obtained and analyzed.

Zhang, Neng-Li↗

Contact angle and surface tension measurements of a five-ring polyphenyl ether

Contact angle measurements were performed for a five-ring polyphenyl ether isomeric mixture on M-50 steel in a dry nitrogen atmosphere. Two different techniques were used: (1) a tilting plate apparatus, and (2) a sessile drop apparatus. Measurements were made for the temperature range 25 to 190 C. Surface tension was measured by a differential maximum bubble pressure technique over the range 23 to 220C in room air. The critical surface energy of spreading (gamma (sub c)) was determined for the polyphenyl ether by plotting the cosine of the contact angle (theta) versus the surface tension (gamma (sub LV)). The straight line intercept at cosine theta = 1 is defined as gamma (sub c). Gamma (sub c) was found to be 30.1 dyn/cm for the tilting plate technique and 31.3 dyn/cm for the sessile drop technique. These results indicate that the polyphenyl ether is inherently autophobic (i.e., it will not spread on its own surface film until its surface tension is less than gamma (sub c). This phenomenon is discussed in light of the wettability and wear problems encountered with this fluid.

Jones, W. R., Jr.↗

Contact angle and surface tension measurements of a five-ring polyphenyl ether

Contact angle measurements were performed for a five-ring polyphenyl ether isomeric mixture on M-50 steel in a dry nitrogen atmosphere. Two different techniques were used: (1) a tilting plate apparatus, and (2) a sessile drop apparatus. Measurements were made for the temperature range 25 to 190 C. Surface tension was measured by a differential maximum bubble pressure technique over the range 23 to 220 C in room air. The critical surface energy of spreading (gamma /sub c/) was determined for the polyphenyl ether by plotting the cosine of the contact angle (theta) versus the surface tension (gamma /sub LV/). The straight line intercept at cosine theta = 1 is defined as gamma (sub c). Gamma (sub c) was found to be 30.1 dyn/cm for the tilting plate technique and 31.3 dyn/cm for the sessile drop technique. These results indicate that the polyphenyl ether is inherently autophobic (i.e., it will not spread on its own surface film until its surface tension is less than gamma /sub c/). This phenomenon is discussed in light of the wettability and wear problems encountered with this fluid.

Jones, W. R., Jr.↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond.

36 MATERIALS SCIENCE↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts.

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications

In the low Earth orbit (LEO) space environment, spacecraft surfaces can be altered during atomic oxygen exposure through oxidation and erosion. There can be terrestrial benefits of such interactions, such as the modification of hydrophobic or hydrophilic properties of polymers due to chemical modification and texturing. Such modification of the surface may be useful for biomedical applications. For example, atomic oxygen texturing may increase the hydrophilicity of polymers, such as chlorotrifluoroethylene (Aclar), thus allowing increased adhesion and spreading of cells on textured Petri dishes. The purpose of this study was to determine the effect of atomic oxygen exposure on the hydrophilicity of nine different polymers. To determine whether hydrophilicity remains static after atomic oxygen exposure or changes with exposure, the contact angles between the polymer and a water droplet placed on the polymer s surface were measured. The polymers were exposed to atomic oxygen in a radio frequency (RF) plasma asher. Atomic oxygen plasma treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Significant decreases in the water contact angle occurred with atomic oxygen exposure. Fluorinated polymers were found to be less sensitive to changes in hydrophilicity for equivalent atomic oxygen exposures, and two of the fluorinated polymers became more hydrophobic. The majority of change in water contact angle of the non-fluorinated polymers was found to occur with very low fluence exposures, indicating potential cell culturing benefit with short treatment time.

Beger, Lauren↗

Impact of Pressure-Dependent Interfacial Tension and Contact Angle on Capillary Heterogeneity Trapping of CO2 in Storage Aquifers

Summary Carbon dioxide (CO2) capillary trapping increases the total amount of CO2 that can be effectively immobilized in storage aquifers. This trapping, manifesting itself as accumulated CO2 columns at a continuum scale, is because of capillary threshold effects that occur below low-permeability barriers. Considering that capillary pressure is dictated by heterogeneous pore throat size, the trapped CO2 column height and associated CO2 saturation will vary spatially within a storage aquifer. This variation will be influenced by two pressure-dependent interfacial parameters—CO2/brine interfacial tension (IFT) and CO2/brine/rock contact angle. Our objective is to understand how the pressure dependence of these two parameters affects the heterogeneity of capillary trapped CO2 at a continuum scale. Our conceptual model is a 1D two-zone system with the upper zone being a flow barrier (low permeability) and the lower zone being a flow path (high permeability). The inputs to this model include microfacies-dependent capillary pressure vs. saturation curves and permeability values. The input capillary pressure curves were collected in the literature that represents carbonate microfacies (e.g., dolograinstone) in a prevalent formation in the Permian Basin. We then used the Leverett j-function to scale the capillary pressure curve for the two zones that are assigned with the same or different microfacies. During scaling, we considered the influence of pressure on both the IFT and contact angle of CO2/brine/dolomite systems. We varied the zone permeability contrast ratio from 2 to 50. We then assumed capillary gravity equilibriums and calculated the CO2 saturation buildup corresponding to various trapped CO2 column heights. The CO2 saturation buildup is defined as the CO2 saturation in the lower layer minus that in the upper one. We found that the saturation buildup can be doubled when varying pressure in a storage aquifer, after considering pressure-dependent IFT and contact angles. Thus, assuming these two parameters to be constant across such aquifers would cause large errors in the quantification of capillary trapping of CO2. The whole study demonstrates the importance of considering pressure-dependent interfacial properties in predicting the vertical distribution of capillary trapped CO2. It has important implications in developing a better understanding of leakage risks and consequent storage safety.

Engineering↗

Determination of the Contact Angle Based on the Casimir Effect

In several crystal growth processed based on capillarity, a melt comes into contact with a crucible wall at an angle defined as the contact angle. For molten metals and semiconductors, this contact angle is dependent upon both the crucible and melt material and typical values fall in the range 80-170deg. However, on a microscopic scale, there does not exist a precise and sharp contact angle but rather the melt and solid surfaces merge smoothly and continuously over a distance of up to several micrometers. Accurate modeling requires a more advanced treatment of this interaction. The interaction between the melt and solid surfaces can be calculated by considering two forces: a short-range repulsive force and a longer range (up to a few micrometers) Casimir force. The Casimir force between the two bodies of complex geometry is calculated using a retarded temperature Green's function (Matsubara type) for the photon in the medium. The governing equations are cast in the form of a set of boundary integral equations which are then solved numerically for the case of molten Ge on SiO2. The shape of the molten surface approaching the flat solid body is determined, and the contact angle is defined as the angle between the two surfaces at the microscopically asymptotic distance of 1-2 micrometers. The formulation of this model and the results of the numerical calculations will be presented and discussed.

Mazuruk, K.↗

Capillary surfaces in a wedge: Differing contact angles

The possible zero-gravity equilibrium configurations of capillary surfaces u(x, y) in cylindrical containers whose sections are (wedge) domains with corners are investigated mathematically, for the case in which the contact angles on the two sides of the wedge may differ. In such a situation the behavior can depart in significant qualitative ways from that for which the contact angles on the two sides are the same. Conditions are described under which such qualitative changes must occur. Numerically computed surfaces are depicted to indicate the behavior.

Concus, Paul↗

Contact Angles and Surface Tension of Germanium-Silicon Melts

Precise knowledge of material parameters is more and more important for improving crystal growth processes. Two important parameters are the contact (wetting) angle and the surface tension, determining meniscus shapes and surface-tension driven flows in a variety of methods (Czochralski, EFG, floating-zone, detached Bridgman growth). The sessile drop technique allows the measurement of both parameters simultaneously and has been used to measure the contact angles and the surface tension of Ge(1-x)Si(x) (0 less than or equal to x less than or equal to 1.3) alloys on various substrate materials. Fused quartz, Sapphire, glassy carbon, graphite, SiC, carbon-based aerogel, pyrolytic boron nitride (pBN), AIN, Si3N4, and polycrystalline CVD diamond were used as substrate materials. In addition, the effect of different cleaning procedures and surface treatments on the wetting behavior were investigated. Measurements were performed both under dynamic vacuum and gas atmospheres (argon or forming gas), with temperatures up to 1100 C. In some experiments, the sample was processed for longer times, up to a week, to investigate any changes of the contact angle and/or surface tension due to slow reactions with the substrate. For pure Ge, stable contact angles were found for carbon-based substrates and for pBN, for Ge(1-x)Si(x) only for pBN. The highest wetting angles were found for pBN substrates with angles around 170deg. For the surface tension of Ge, the most reliable values resulted in gamma(T) = (591- 0.077 (T-T(sub m)) 10(exp -3)N/m. The temperature dependence of the surface tension showed similar values for Ge(1-x)Si(x), around -0.08 x 10(exp -3)N/m K, and a compositional dependence of 2.2 x 10(exp -3)N/m at%Si.

Croell, A.↗

Tool Indicates Contact Angles In Bearing Raceways

Tool devised for use in measuring contact angles between balls and races in previously operated ball bearings. Used on both inner and outer raceways of bearings having cross-sectional widths between approximately 0.5 and 2.0 in. Consists of integral protractor mounted in vertical plane on bracket equipped with leveling screws and circular level indicator. Protractor includes rotatable indicator needle and set of disks of various sizes to fit various raceway curvatures.

Akian, Richard A.↗

Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications

The purpose of this study was to determine the effect of atomic oxygen (AO) exposure on the hydrophilicity of nine different polymers for biomedical applications. Atomic oxygen treatment can alter the chemistry and morphology of polymer surfaces, which may increase the adhesion and spreading of cells on Petri dishes and enhance implant growth. Therefore, nine different polymers were exposed to atomic oxygen and water-contact angle, or hydrophilicity, was measured after exposure. To determine whether hydrophilicity remains static after initial atomic oxygen exposure, or changes with higher fluence exposures, the contact angles between the polymer and water droplet placed on the polymer s surface were measured versus AO fluence. The polymers were exposed to atomic oxygen in a 100-W, 13.56-MHz radio frequency (RF) plasma asher, and the treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Pristine samples were compared with samples that had been exposed to AO at various fluence levels. Minimum and maximum fluences for the ashing trials were set based on the effective AO erosion of a Kapton witness coupon in the asher. The time intervals for ashing were determined by finding the logarithmic values of the minimum and maximum fluences. The difference of these two values was divided by the desired number of intervals (ideally 10). The initial desired fluence was then multiplied by this result (2.37), as was each subsequent desired fluence. The flux in the asher was determined to be approximately 3.0 x 10(exp 15) atoms/sq cm/sec, and each polymer was exposed to a maximum fluence of 5.16 x 10(exp 20) atoms/sq cm.

deGroh, Kim↗

Contact angle measurements of a polyphenyl ether to 190 C on M-50 steel

Contact angle measurements were performed for a polyphenyl ether on steel in nitrogen. A tilting plate and a sessile drop apparatus were used. Surface tension was measured with a maximum bubble pressure apparatus. Critical surface energies of spreading were found to be 30.1 and 31.3 dynes/cm. It was concluded that the polyphenyl ether is inherently autophobic and will not spread on its own surface film.

Jones, W. R., Jr.↗

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗