Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measuring the Hubble constant and spatial curvature from supernova apparent magnitude, baryon acoustic oscillation, and Hubble parameter data

Cosmic microwave background (CMB) anisotropy (spatial inhomogeneity) data provide the tightest constraints on the Hubble constant, matter density, spatial curvature, and dark energy dynamics. Other data, sensitive to the evolution of only the spatially homogeneous part of the cosmological model, such as Type Ia supernova apparent magnitude, baryon acoustic oscillation distance, and Hubble parameter measurements, can be used in conjunction with the CMB data to more tightly constrain parameters. Recent joint analyses of CMB and such non-CMB data indicate that slightly closed spatial hypersurfaces are favored in nonflat untilted inflation models and that dark energy dynamics cannot be ruled out, and favor a smaller Hubble constant. Here, we show that the constraints that follow from these non-CMB data alone are consistent with those that follow from the CMB data alone and so also consistent with, but weaker than, those that follow from the joint analyses of the CMB and non-CMB data.

79 ASTRONOMY AND ASTROPHYSICS↗

Coarse-Grained Models for Constant pH Simulations of Carboxylic Acids

A model for carboxylic acids, in both the protonated and deprotonated states, is developed in which hydrogen interaction sites are not used and all interactions are short-ranged. A method for constant pH simulations, which exploits these features of the model, is developed. Here, the constant pH method samples protonation states by making discrete Monte Carlo steps and is able to efficiently move between states in two steps. The method is applied to the polymer poly(methacrylic acid), a pH-responsive polymer that undergoes structural changes as a function of pH. The model is able to reproduce the structural changes induced by pH.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermodynamics of electrolyte solutions near charged surfaces: Constant surface charge vs constant surface potential

Electric double layers are ubiquitous in science and engineering and are of current interest, owing to their applications in the stabilization of colloidal suspensions and as supercapacitors. While the structure and properties of electric double layers in electrolyte solutions near a charged surface are well characterized, there are subtleties in calculating thermodynamic properties from the free energy of a system with charged surfaces. These subtleties arise from the difference in the free energy between systems with constant surface charge and constant surface potential. In this work, we present a systematic, pedagogical framework to properly account for the different specifications on charged bodies in electrolyte solutions. Our approach is fully variational—that is, all free energies, boundary conditions, relevant electrostatic equations, and thermodynamic quantities are systematically derived using variational principles of thermodynamics. We illustrate our approach by considering a simple electrolyte solution between two charged surfaces using the Poisson–Boltzmann theory. Our results highlight the importance of using the proper thermodynamic potential and provide a general framework for calculating thermodynamic properties of electrolyte solutions near charged surfaces. Specifically, we present the calculation of the pressure and the surface tension between two charged surfaces for different boundary conditions, including mixed boundary conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample variance in the local measurements of the Hubble constant

The current >3σ tension between the Hubble constant H 0 measured from local distance indicators and from cosmic microwave background is one of the most highly debated issues in cosmology, as it possibly indicates new physics or unknown systematics. In this work, we explore whether this tension can be alleviated by the sample variance in the local measurements, which use a small fraction of the Hubble volume. We use a large-volume cosmological N-body simulation to model the local measurements and to quantify the variance due to local density fluctuations and sample selection. We explicitly take into account the inhomogeneous spatial distribution of type Ia supernovae. Despite the faithful modelling of the observations, our results confirm previous findings that sample variance in the local Hubble constant ($H$ $^{loc}_{0}$) measurements is small; we find σ ($H$ $^{loc}_{0}$)=0.31km s -1 Mpc -1 a nearly negligible fraction of the ~6 km s -1 Mpc -1 necessary to explain the difference between the local and global H 0 measurements. While the H 0 tension could in principle be explained by our local neighbourhood being a underdense region of radius ~150 Mpc, the extreme required underdensity of such a void (δ ≃ -0.8) makes it very unlikely in a ΛCDM universe, and it also violates existing observational constraints. Furthermore, sample variance in a ΛCDM universe cannot appreciably alleviate the tension in H 0 measurements even after taking into account the inhomogeneous selection of type Ia supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining the hubble constant from hubble parameter measurements

We use 28 measurements of the Hubble parameter, H(z), at intermediate redshifts 0.07⩽z⩽2.3 to determine the present-day Hubble constant H{sub 0} in four cosmological models. We measure H{sub 0}=68.3{sub −2.6}{sup +2.7},68.4{sub −3.3}{sup +2.9},65.0{sub −6.6}{sup +6.5}, and 67.9{sub −2.4}{sup +2.4} km s{sup −1} Mpc{sup −1} (1σ errors) in the ΛCDM (spatially flat and non-flat), ωCDM, and ϕCDM models, respectively. These measured H{sub 0} values are more consistent with the lower values determined from recent data on the cosmic microwave background and baryon acoustic oscillations, as well as with the value found from a median statistical analysis of Huchra’s compilation of H{sub 0} measurements, but include the higher local measurements of H{sub 0} within the 2σ confidence limits.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of constant-load and constant-deflection stress-corrosion tests on precracked DCB specimens

A comparison is made between measurements of stress-corrosion crack propagation made by a constant-load procedure and by a constant-deflection procedure. Precracked double cantilever beam specimens from 7075 aluminum alloy plate were used. The specimens were oriented in such a way that cracking would begin in the short-transverse plane and would propagate in the rolling direction. The specimens were subjected to a buffered salt-chromate solution and a 3.6% synthetic sea salt solution. The measurements were made optically with a binocular microscope. Stress intensities and crack lengths were calculated and crack velocities were obtained. Velocity was plotted against the average calculated stress intensity. Good agreement between the two methods was found for the salt-chromate solution, although some descrepancies were noted for the artificial sea salt solution.

Dorward, R. C.↗

Cohesive Energy-Lattice Constant and Bulk Modulus-Lattice Constant Relationships: Alkali Halides, Ag Halides, Tl Halides

In this note we present two expressions relating the cohesive energy, E(sub coh), and the zero pressure isothermal bulk modulus, B(sub 0), of the alkali halides. Ag halides and TI halides, with the nearest neighbor distances, d(sub nn). First, we show that the product E(sub coh)d(sub 0) within families of halide crystals with common crystal structure is to a good approximation constant, with maximum rms deviation of plus or minus 2%. Secondly, we demonstrate that within families of halide crystals with a common cation and common crystal structure the product B(sub 0)d(sup 3.5)(sub nn) is a good approximation constant, with maximum rms deviation of plus or minus 1.36%.

Schlosser, Herbert↗

Accurate Optical Constants for Liquids in the Near-Infrared: Improved Methods for Obtaining the n and k Constants from 1 to 4 Microns

Other than open bodies of water, bulk liquids are rarely encountered in the environment. Rather, liquids are typically found as aerosols, liquid droplets, or liquid layers on sundry substrates: glass, concrete, metals, etc. The layers can be of varying thicknesses, from micron-level to millimeter thick deposits. The infrared (IR) reflectance spectra of such deposits vary greatly, approximating the bulk reflectance for thicker deposits and for thinner layers on reflective surfaces, producing “transflectance” spectra that more closely replicate simple transmission of the IR light twice traversing the absorptive medium. Rather than recording large numbers of such spectra to serve as endmembers of a spectral reflectance library, we have recognized that the spectra can be modeled so long as the complex optical constants n(?) and k(?) are known as a function of frequency, ?. Here n is the real (dispersion) part and k is the imaginary (absorption) component of the complex index of refraction. However, in many cases the bands in the longwave IR (7 to 13 µm) can become saturated, and better signal-to-noise and specificity can be realized at shorter wavelengths. In earlier studies, we obtained the n/k values from 1.28 to 25 µm for a series of liquids, but are now expanding those measurements to include additional liquid species and extending the spectral range to lower wavelengths. In this paper we describe the methodologies for compiling and fusing the two data sets collected to provide better and more complete spectral coverage from 1 to 25 µm (10,000 to 400 cm-1). The broad spectral range means that one needs to account for both strong and weak spectral features, all of which can be useful for detection, depending on the scenario. To account for the large dynamic range, both long and short path length transmission cells are required for accurate measurements.

optical constants, refractive index, liquids, mid ↗

Generalized Charts for Determination of Pressure Drop of a High-speed Compressible Fluid in Heat-exchanger Passages I : Air Heated in Smooth Passages of Constant Area with Constant Wall Temperature

In the present paper an analysis is made of the compressible-flow variations occurring in heat-exchanger passages. The results of the analysis describe the flow and heating characteristics for which specific flow passages can be treated as segments of generalized flow systems. The graphical representation of the flow variations in the generalized flow systems can then be utilized as working charts to determine directly the pressure changes occurring in any specific flow passage. On the basis of these results, working charts are constructed to handle the case of air heated at constant wall temperature under turbulent-flow conditions. A method is given of incorporating the effect on the heat-exchanger flow process of high temperature differential between passage wall and fluid as based on recent NACA experimental data. Good agreement is obtained between the experimental and the chart pressure-drop values for passage-wall average temperatures as high as 1752 degrees R (experimental limit) and for flow Mach numbers ranging from 0.32 to 1.00 (choke) at the passage exit.

Valerino, Michael F↗