Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Confidence interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Supplementary Clear-Sky Snow and Ice Recognition Technique for CERES Level 2 Products

Identification of clear-sky snow and ice is an important step in the production of cryosphere radiation budget products, which are used in the derivation of long-term data series for climate research. In this paper, a new method of clear-sky snow/ice identification for Moderate Resolution Imaging Spectroradiometer (MODIS) is presented. The algorithm's goal is to enhance the identification of snow and ice within the Clouds and the Earth's Radiant Energy System (CERES) data after application of the standard CERES scene identification scheme. The input of the algorithm uses spectral radiances from five MODIS bands and surface skin temperature available in the CERES Single Scanner Footprint (SSF) product. The algorithm produces a cryosphere rating from an aggregated test: a higher rating corresponds to a more certain identification of the clear-sky snow/ice-covered scene. Empirical analysis of regions of interest representing distinctive targets such as snow, ice, ice and water clouds, open waters, and snow-free land selected from a number of MODIS images shows that the cryosphere rating of snow/ice targets falls into 95% confidence intervals lying above the same confidence intervals of all other targets. This enables recognition of clear-sky cryosphere by using a single threshold applied to the rating, which makes this technique different from traditional branching techniques based on multiple thresholds. Limited tests show that the established threshold clearly separates the cryosphere rating values computed for the cryosphere from those computed for noncryosphere scenes, whereas individual tests applied consequently cannot reliably identify the cryosphere for complex scenes.

Radkevich, Alexander↗

Atrial Septal Aneurysm and Patent Foramen Ovale as Risk Factors for Cryptogenic Stroke in Patients Less Than 55 Years of Age: A Study using Transesophageal Echocardiography

Background and Purpose: An association between atrial septal aneurysm and embolic events has been suggested. Atrial septal aneurysm has been shown to be associated with patent foramen ovale and,.in some reports, with mitral valve prolapse. These two latter cardiac disorder; have been identified as potential risk factors for ischemic stroke. The aim of this prospective study was to assess the role of atrial septal aneurysm as an independent risk factor for stroke, especially for cryptogenic stroke. Methods: We studied the prevalence of atrial septal aneurysm, patent foramen ovale, and mitral valve prolapse in 100 consecutive patients <55 years of age with ischemic stroke who underwent extensive etiological investigations. We compared these results with those in a control group of 50 consecutive patients. The diagnosis of atrial septal aneurysm and patent foramen ovale relied on transesophageal echocardiography with a contrast study and that of mitral valve prolapse, on two-dimensional transthoracic echocardiography. Results: Stepwise logistic regression analysis showed that atrial septal aneurysm (odds ratio, 4.3; 95% confidence interval, 1.3 to 14.6; P=.01) and patent foramen ovale (odds ratio, 3.9; 95% confidence interval, 1.5 to 10; P=.003) but not mitral valve prolapse were significantly associated with the diagnosis of cryptogenic stroke. The stroke odds of a patient with both atrial septal aneurysm and patent foramen ovale were 33.3 times (95% confidence interval, 4.1 to 270) the stroke odds of a patient with neither of these cardiac disorders. For a patient with atrial septal aneurysm of >lo-mm excursion, the stroke odds were approximately 8 times the stroke odds of a patient with atrial septal aneurysm of <10 mm. Conclusions: This study shows that atrial septal aneurysm and patent foramen ovale are both significantly associated with cryptogenic stroke and that their association has a marked synergistic effect. Atrial septal aneurysms of >lo-mm excursion are associated with a higher risk of stroke. (Stroke. 1993;24:1865-1873.) KEY WORDS aneurysm echocardiography foramen ovale, patent mitral valve prolapse o young adults

Cabanes, L.↗

Impact Real World System Validation

Introduction NASA has developed a new evidence-based data-driven probabilistic risk assessment and tradespace analysis tool as a successor to the Integrated Medical Model. This updated decision support tool is known as IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces). IMPACT estimates the frequency and consequences of medical conditions that might arise during exploration missions. A validation analysis of IMPACT was performed with respect to a set of International Space Station (ISS) and Shuttle Transportation System (STS) real world system (RWS) referent data due to the limited referent data available from exploration missions. Methods Observed mission and crew characteristics from STS and ISS missions were used as model inputs within MEDPRAT (Medical Extensible Dynamic Probabilistic Risk Assessment Tool). For each mission, two hundred thousand simulations were generated. For each mission, model outputs included occurrence counts for each condition, total medical events (TME), and the probability of loss of crew life (LOCL). These simulated model outputs were compared to the RWS referent data. Results The predicted number of total medical events exceeded the total RWS medical events for ISS missions and combined ISS and STS missions and fell within the 90% confidence interval for STS missions. For the 32 ISS missions simulated by IMPACT, the number of total medical events was overpredicted for 19 missions and fell within the 90% confidence interval for 13 missions. For the 21 STS missions, the total number of medical events was overpredicted for 3 missions, fell within the 90% confidence interval for 16 missions, and was underpredicted for 2 missions. Combined, 29 missions were in range, 22 were overpredicted, and 2 were underpredicted. The predicted LOCL probability for the 32 ISS missions, the 21 STS missions, and the combined ISS and STS missions was consistent with the zero LOCL events observed in the RWS referent data. The validation analysis included a comparison of the number of medical events predicted by IMPACT and the number of medical events observed in the RWS data on a condition-by-condition basis. For ISS missions, 50 conditions were in range, 52 conditions were statistically underpowered (not enough observed sample to draw any conclusions on precision), 8 conditions were overpredicted, and 9 conditions were underpredicted. Overall, only 14% (17/119) of conditions were out of range for STS missions, 40 conditions were in range, 59 conditions were statistically underpowered, 10 conditions were overpredicted, and 10 conditions were underpredicted. Overall, only 17% (20/119) of conditions were out of range. For combined ISS and STS missions, 11 conditions were overpredicted, and 11 conditions were underpredicted. Overall, only 18% (22/119) of conditions were out of range. For combined ISS and STS missions, 49 conditions were in range, 46 conditions were statistically underpowered, 18 conditions were overpredicted, and 8 conditions were underpredicted. Overall, 21% (26/121) of conditions were out of range. Conclusion The results of this validation analysis should not be interpreted as a pass/fail test of the validity of IMPACT. Instead, this validation analysis should be used to assess some of the IMPACT outcomes in terms of consistencies and inconsistencies with the ISS and STS RWS referent data.

L. Boley↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

A comparison of approximate interval estimators for the Bernoulli parameter

The goal of this paper is to compare the accuracy of two approximate confidence interval estimators for the Bernoulli parameter p. The approximate confidence intervals are based on the normal and Poisson approximations to the binomial distribution. Charts are given to indicate which approximation is appropriate for certain sample sizes and point estimators.

Leemis, Lawrence↗

A Comparison Between Raman Lidar and Conventional Contact Measurements of Atmospheric Temperature

Described here are the results of comparison between lidar and conventional contact measurements of the vertical temperature profile of the atmosphere. The lidar measurements are based on the method of temperature dependence of pure rotational Raman scattering of nitrogen and oxygen molecules. The presented results show that, as a whole, the motion of the lidar and conventional profiles coincide in the confidence intervals. Still there are districts in which the differences lay out of the confidence intervals. In analysis and estimation of the coincidence and the distinction in moving the profiles, we must take into account the differences between the methods for measuring the temperature profiles by lidar and contact methods, i.e. the next additional factors. The tied balloon meter gives the momentary values of the temperature in particular points of the profile, as these momentary values are the results of consequent, but not simultaneous measurements. In the case of free flying balloon, the time of measuring the lower several hundred meters is little because of high vertical velocity (about 300 m/min). This leads to an indefinite increase of the measuring error. The complete space coincidence between the lidar's and conventional profiles isn't possible. The contribution of the factors mentioned above about the error of comparison could increase because of nonstable layers in the planetary boundary layer of the atmosphere as well as by the influence of the mountains and the city situated nearby.

Mitev, V. M.↗

Blind Validation Study of PRICE TruePlanning and SEER-H

Two of the primary parametric costing tools used to estimate the development and production cost of future spacecraft hardware are PRICE TruePlanning by PRICE Systems, and System Estimation and Evaluation of Resources-Hardware (SEER-H) by Galorath. These are standard tools used by NASA and industry to estimate the cost of new aerospace hardware. This study is an independent verification of the accuracy of these tools and was originally published in 2018. The purpose of this presentation is to circulate the findings of that study among the NASA cost community. Both PRICE Systems and Galorath have completed internal validation studies of their parametric cost estimating tools; however, they only provided the results of the studies and did not detail the exact methods used to perform the validation. In the present study, cost estimators used PRICE TruePlanning and SEER-H to estimate the cost of twelve different past NASA science missions. The estimators were prevented from knowing the actual cost of the missions in an effort to minimize cognitive biases. In the present study, SEER-H had an average error of 23%, median error of -0.3%, with a standard deviation of 43%. PRICE had an average error of 52%, median error of 50%, and standard deviation of 45%. Nine of the twelve mission's actual costs fell within the 80% confidence interval of SEER's probabilistic estimates; however, none of the missions fell within PRICE’s confidence intervals. There were several factors independent of PRICE and SEER-H which may have affected the accuracy of the results in the present study including: uncertainty in the technical data used for the estimates, the methods used to estimate uncertainty in spacecraft component mass and numbers of prototypes, and the experience of the estimators.

SEER↗

The statistical significance of error probability as determined from decoding simulations for long codes

The very low error probability obtained with long error-correcting codes results in a very small number of observed errors in simulation studies of practical size and renders the usual confidence interval techniques inapplicable to the observed error probability. A natural extension of the notion of a 'confidence interval' is made and applied to such determinations of error probability by simulation. An example is included to show the surprisingly great significance of as few as two decoding errors in a very large number of decoding trials.

Massey, J. L.↗

Initial Validation of NDVI time seriesfrom AVHRR, VEGETATION, and MODIS

The paper will address Theme 7: Multi-sensor opportunities for VEGETATION. We present analysis of a long-term vegetation record derived from three moderate resolution sensors: AVHRR, VEGETATION, and MODIS. While empirically based manipulation can ensure agreement between the three data sets, there is a need to validate the series. This paper uses atmospherically corrected ETM+ data available over the EOS Land Validation Core Sites as an independent data set with which to compare the time series. We use ETM+ data from 15 globally distributed sites, 7 of which contain repeat coverage in time. These high-resolution data are compared to the values of each sensor by spatially aggregating the ETM+ to each specific sensors' spatial coverage. The aggregated ETM+ value provides a point estimate for a specific site on a specific date. The standard deviation of that point estimate is used to construct a confidence interval for that point estimate. The values from each moderate resolution sensor are then evaluated with respect to that confident interval. Result show that AVHRR, VEGETATION, and MODIS data can be combined to assess temporal uncertainties and address data continuity issues and that the atmospherically corrected ETM+ data provide an independent source with which to compare that record. The final product is a consistent time series climate record that links historical observations to current and future measurements.

Morisette, Jeffrey T.↗

Exact intervals and tests for median when one sample value possibly an outliner

Available are independent observations (continuous data) that are believed to be a random sample. Desired are distribution-free confidence intervals and significance tests for the population median. However, there is the possibility that either the smallest or the largest observation is an outlier. Then, use of a procedure for rejection of an outlying observation might seem appropriate. Such a procedure would consider that two alternative situations are possible and would select one of them. Either (1) the n observations are truly a random sample, or (2) an outlier exists and its removal leaves a random sample of size n-1. For either situation, confidence intervals and tests are desired for the median of the population yielding the random sample. Unfortunately, satisfactory rejection procedures of a distribution-free nature do not seem to be available. Moreover, all rejection procedures impose undesirable conditional effects on the observations, and also, can select the wrong one of the two above situations. It is found that two-sided intervals and tests based on two symmetrically located order statistics (not the largest and smallest) of the n observations have this property.

Keller, G. J.↗

Extensive Global Wetland Loss Over the Past Three Centuries

Wetlands have long been drained for human use, thereby strongly affecting greenhouse gas fluxes, flood control, nutrient cycling and biodiversity. Nevertheless, the global extent of natural wetland loss remains remarkably uncertain. Here, we reconstruct the spatial distribution and timing of wetland loss through conversion to seven human land uses between 1700 and 2020, by combining national and subnational records of drainage and conversion with land-use maps and simulated wetland extents. We estimate that 3.4 million km 2 (confidence interval 2.9–3.8) of inland wetlands have been lost since 1700, primarily for conversion to croplands. This net loss of 21% (confidence interval 16–23%) of global wetland area is lower than that suggested previously by extrapolations of data disproportionately from high-loss regions. Wetland loss has been concentrated in Europe, the United States and China, and rapidly expanded during the mid-twentieth century. Our reconstruction elucidates the timing and land-use drivers of global wetland losses, providing an improved historical baseline to guide assessment of wetland loss impact on Earth system processes, conservation planning to protect remaining wetlands and prioritization of sites for wetland restoration.

Etienne Fluet-Chouinard↗

Stochastic performance robustness of aircraft control systems

Stochastic robustness, a simple technique used to estimate the robustness of linear, time-invariant systems, is applied to a twin-jet transport aircraft control system. Concepts behind stochastic stability robustness are extended to stochastic performance robustness. Stochastic performance robustness measures based on classical design specifications and measures specific to aircraft handling qualities are introduced. Confidence intervals for both individual stochastic robustness measures and for comparing two measures are presented. The application of stochastic performance robustness, the use of confidence intervals, and tradeoffs between performance objectives are demonstrated by means of the twin-jet aircraft example.

Stengel, Robert F.↗

Uncertainty and Sensitivity Analyses of Duct Propagation Models

This paper presents results of uncertainty and sensitivity analyses conducted to assess the relative merits of three duct propagation codes. Results from this study are intended to support identification of a "working envelope" within which to use the various approaches underlying these propagation codes. This investigation considers a segmented liner configuration that models the NASA Langley Grazing Incidence Tube, for which a large set of measured data was available. For the uncertainty analysis, the selected input parameters (source sound pressure level, average Mach number, liner impedance, exit impedance, static pressure and static temperature) are randomly varied over a range of values. Uncertainty limits (95% confidence levels) are computed for the predicted values from each code, and are compared with the corresponding 95% confidence intervals in the measured data. Generally, the mean values of the predicted attenuation are observed to track the mean values of the measured attenuation quite well and predicted confidence intervals tend to be larger in the presence of mean flow. A two-level, six factor sensitivity study is also conducted in which the six inputs are varied one at a time to assess their effect on the predicted attenuation. As expected, the results demonstrate the liner resistance and reactance to be the most important input parameters. They also indicate the exit impedance is a significant contributor to uncertainty in the predicted attenuation.

Nark, Douglas M.↗

Evidence-Based Approach to the Analysis of Serious Decompression Sickness with Application to EVA Astronauts

It is important to understand the risk of serious hypobaric decompression sickness (DCS) in order to develop procedures and treatment responses to mitigate the risk. Since it is not ethical to conduct prospective tests about serious DCS with humans, the necessary information was gathered from 73 published reports. We hypothesize that a 4-hr 100% oxygen (O2) prebreathe results in a very low risk of serious DCS, and test this through analysis. We evaluated 258 tests containing information from 79,366 exposures in attitude chambers. Serious DCS was documented in 918 men during the tests. Serious DCS are signs and symptoms broadly classified as Type II DCS. A risk function analysis with maximum likelihood optimization was performed to identify significant explanatory variables, and to create a predictive model for the probability of serious DCS [P(serious DCS)]. Useful variables were Tissue Ratio, the planned time spent at altitude (T(sub alt)), and whether or not repetitive exercise was performed at altitude. Tissue Ratio is P1N2/P2, where P1N2 is calculated nitrogen (N2) pressure in a compartment with a 180-min half-time for N2 pressure just before ascent, and P2 is ambient pressure after ascent. A prebreathe and decompression profile Shuttle astronauts use for extravehicular activity (EVA) includes a 4-hr prebreathe with 100% O2, an ascent to P2 = 4.3 lb per sq. in. absolute, and a T(sub alt) = 6 hr. The P(serious DCS) is: 0.0014 (0.00096 - 0.00196, 95% confidence interval) with exercise and 0.00025 (0.00016 - 0.00035) without exercise. Given 100 Shuttle EVAs to date and no report of serious DCS, the true risk is less than 0.03 with 95% confidence (Binomial Theorem). It is problematic to estimate the risk of serious DCS since it appears infrequently, even if the estimate is based on thousands of altitude chamber exposures. The true risk to astronauts may lie between the extremes of the confidence intervals (0.00016 - 0.00196) since the contribution of other factors, particularly exercise, to the risk of serious DCS during EVA is unknown. A simple model that only accounts for four important variables in retrospective data is still helpful to increase our understanding about the risk of serious DCS.

Conkin, Johnny↗

Effects of aerodynamic heating and TPS thermal performance uncertainties on the Shuttle Orbiter

A procedure for estimating uncertainties in the aerodynamic-heating and thermal protection system (TPS) thermal-performance methodologies developed for the Shuttle Orbiter is presented. This procedure is used in predicting uncertainty bands around expected or nominal TPS thermal responses for the Orbiter during entry. Individual flowfield and TPS parameters that make major contributions to these uncertainty bands are identified and, by statistical considerations, combined in a manner suitable for making engineering estimates of the TPS thermal confidence intervals and temperature margins relative to design limits. Thus, for a fixed TPS design, entry trajectories for future Orbiter missions can be shaped subject to both the thermal-margin and confidence-interval requirements. This procedure is illustrated by assessing the thermal margins offered by selected areas of the existing Orbiter TPS design for an entry trajectory typifying early flight test missions.

Goodrich, W. D.↗

Statistical analysis of failure data on controllers and SSME turbine blade failures

The expressions for the maximum likelihood functions are given when the failure data are censored at a given point or at multiple points, or when the data come in groups. Different models applicable to failure data are presented with their characteristics. A graphical method of distinguishing different models by using cumulative hazard fucnction is discussed. For the failure data on controllers the model is determined by cumulative hazard function and chi-square goodness of fit. Using the Weibull Model the maximum likelihood estimators of the shape parameter and the failure rate parameter are obtained. The confidence intervals, meantime between failures, and B1 are determined. Similarly, for the data on Space Shuttle Main Engine (SSME) blade failures the maximum likelihood estimators are obtained for the Weibull parameters. The variances, confidence intervals, meantime between failures, and reliability are determined. The analysis is performed under assumption of grouped data as well as randomly placed data.

Patil, S. A.↗

SeaWiFS technical report series. Volume 26: Results of the SeaWiFS Data Analysis Round-Robin, July 1994 (DARR-1994)

The accurate determination of upper ocean apparent optical properties (AOP's) is essential for the vicarious calibration of the sea-viewing wide field-of-view sensor (SeaWiFS) instrument and the validation of the derived data products. To evaluate the role that data analysis methods have upon values of derived AOP's, the first Data Analysis Round-Robin (DARR-94) workshop was sponsored by the SeaWiFS Project during 21-23 July, 1994. The focus of this intercomparison study was the estimation of the downwelling irradiance spectrum just beneath the sea surface, E(sub d)(0(sup -), lambda); the upwelling nadir radiance just beneath the sea surface, L(sub u)(0(sup -), lambda); and the vertical profile of the diffuse attenuation coefficient spectrum, K(sub d)(z, lambda). In the results reported here, different methodologies from four research groups were applied to an identical set of 10 spectroradiometry casts in order to evaluate the degree to which data analysis methods influence AOP estimation, and whether any general improvements can be made. The overall results of DARR-94 are presented in Chapter 1 and the individual methods of the four groups are presented in Chapters 2-5. The DARR-94 results do not show a clear winner among data analysis methods evaluated. It is apparent, however, that some degree of outlier rejection is required in order to accurately estimate L(sub u)(0(sup -), lambda) or E(sub d)(0(sup -), lambda). Furthermore, the calculation, evaluation and exploitation of confidence intervals for the AOP determinations needs to be explored. That is, the SeaWiFS calibration and validation problem should be recast in statistical terms where the in situ AOP values are statistical estimates with known confidence intervals.

Hooker, Stanford B.↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers were collected and analyzed to determine how the data compares to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e. Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100 %. The tensile strength samples of the C/W pairs values followed a normal distribution with an average tensile strength value that was at least 182 % of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95 % confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that there is good likelihood to observe C/W pair normal distribution with a 95 % confidence interval that will meet and surpass the standard requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It could be possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project must evaluate the impact to risk from reducing the frequency of testing.

Crimped connections↗