Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Concurrent Function Evaluations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluating Optimization Strategies for Engine Simulations Using Machine Learning Emulators

This work evaluates different optimization algorithms for computational fluid dynamics (CFD) simulations of engine combustion. Due to the computational expense of CFD simulations, emulators built with machine learning algorithms were used as surrogates for the optimizers. Two types of emulators were used: a Gaussian process (GP) and a weighted variety of machine learning methods called SuperLearner (SL). The emulators were trained using a dataset of 2048 CFD simulations that were run concurrently on a supercomputer. The design of experiments (DOE) for the CFD runs was obtained by perturbing nine input parameters using a Monte-Carlo method. The CFD simulations were of a heavy duty engine running with a low octane gasoline-like fuel at a partially premixed compression ignition mode. Ten optimization algorithms were tested, including types typically used in research applications. Each optimizer was allowed 800 function evaluations and was randomly tested 100 times. The optimizers were evaluated for the median, minimum, and maximum merits obtained in the 100 attempts. Some optimizers required more sequential evaluations, thereby resulting in longer wall clock times to reach an optimum. The best performing optimization methods were particle swarm optimization (PSO), differential evolution (DE), GENOUD (an evolutionary algorithm), and micro-genetic algorithm (GA). These methods found a high median optimum as well as a reasonable minimum optimum of the 100 trials. Moreover, all of these methods were able to operate with less than 100 successive iterations, which reduced the wall clock time required in practice. Two methods were found to be effective but required a much larger number of successive iterations: the DIRECT and MALSCHAINS algorithms. A random search method that completed in a single iteration performed poorly in finding optimum designs but was included to illustrate the limitation of highly concurrent search methods. The last three methods, Nelder–Mead, bound optimization by quadratic approximation (BOBYQA), and constrained optimization by linear approximation (COBYLA), did not perform as well.

Probst, Daniel M.↗

A Phase II Study of Radiotherapy and Concurrent Paclitaxel Chemotherapy in Breast-Conserving Treatment for Node-Positive Breast Cancer

Purpose: Administering adjuvant chemotherapy before breast radiotherapy decreases the risk of systemic recurrence, but delays in radiotherapy could yield higher local failure. We assessed the feasibility and efficacy of placing radiotherapy earlier in the breast-conserving treatment course for lymph node-positive breast cancer. Methods and Materials: Between June 2000 and December 2004, 44 women with node-positive Stage II and III breast cancer were entered into this trial. Breast-conserving surgery and 4 cycles of doxorubicin (60 mg/m{sup 2})/cyclophosphamide (600 mg/m{sup 2}) were followed by 4 cycles of paclitaxel (175 mg/m{sup 2}) delivered every 3 weeks. Radiotherapy was concurrent with the first 2 cycles of paclitaxel. The breast received 39.6 Gy in 22 fractions with a tumor bed boost of 14 Gy in 7 fractions. Regional lymphatics were included when indicated. Functional lung volume was assessed by use of the diffusing capacity for carbon monoxide as a proxy. Breast cosmesis was evaluated with the Harvard criteria. Results: The 5-year actuarial rate of disease-free survival is 88%, and overall survival is 93%. There have been no local failures. Median follow-up is 75 months. No cases of radiation pneumonitis developed. There was no significant change in the diffusing capacity for carbon monoxide either immediately after radiotherapy (p = 0.51) or with extended follow-up (p = 0.63). Volume of irradiated breast tissue correlated with acute cosmesis, and acute Grade 3 skin toxicity developed in 2 patients. Late cosmesis was not adversely affected. Conclusions: Concurrent paclitaxel chemotherapy and radiotherapy after breast-conserving surgery shortened total treatment time, provided excellent local control, and was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Older Adult With Locoregionally Advanced Head and Neck Squamous Cell Carcinoma: Knowledge Gaps and Future Direction in Assessment and Treatment

Older adults with head and neck squamous cell carcinoma (HNSCC) pose unique treatment and supportive care challenges to oncologists and other cancer care providers. The majority of patients with HNSCC present with locoregionally advanced disease, for which combined-modality treatment integrating chemotherapy and radiation therapy is often necessary to maximize tumor control. However, applying these approaches to an older population with concomitant comorbidities and a higher risk of functional impairments remains challenging and is exacerbated by the paucity of studies involving older adults. The purpose of this article is to identify knowledge gaps in the evaluation and management of older adults with HNSCC—particularly those undergoing concurrent chemoradiation therapy—and their caregivers through a review of the literature conducted by clinicians, researchers, and patient advocates. The findings highlight the importance of a geriatric assessment and the therapeutic paradigms and challenges relevant to this population. Furthermore, we identify the need for additional research and interventions related to key supportive care issues that arise during and after treatment in older adults with locoregionally advanced HNSCC. On the basis of our findings, we prioritize these issues to guide future patient-oriented research endeavors to address these knowledge gaps and thus better serve this growing patient population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LibERI—A portable and performant multi-GPU accelerated library for electron repulsion integrals via OpenMP offloading and standard language parallelism

A portable and performant graphics processing unit (GPU)-accelerated library for electron repulsion integral (ERI) evaluation, named LibERI, has been developed and implemented via directive-based (e.g., OpenMP and OpenACC) and standard language parallelism (e.g., Fortran DO CONCURRENT). Offloaded ERIs consist of integrals over low and high contraction s, p, and d functions using the rotated-axis and Rys quadrature methods. GPU codes are factorized based on previous developments with two layers of integral screening and quartet presorting. In this work, the density screening is moved to the GPU to enhance the computational efficacy for large molecular systems. Here, the L-shells in the Pople basis set are also separated into pure S and P shells to increase the ERI homogeneity and reduce atomic operations and the memory footprint. LibERI is compatible with any quantum chemistry drivers supporting the MolSSI Driver Interface. Benchmark calculations of LibERI interfaced with the GAMESS software package were carried out on various GPU architectures and molecular systems. The results show that the LibERI performance is comparable to other state-of-the-art GPU-accelerated codes (e.g., TeraChem and GMSHPC) and, in some cases, outperforms conventionally developed ERI CUDA kernels (e.g., QUICK) while fully maintaining portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disturbance triggers non-linear microbe–environment feedbacks

Abstract. Conceptual frameworks linking microbial community membership, properties, and processes with the environment and emergent function have been proposed but remain untested. Here we refine and test a recent conceptual framework using hyporheic zone sediments exposed to wetting–drying transitions. Our refined framework includes relationships between cumulative properties of a microbial community (e.g., microbial membership, community assembly properties, and biogeochemical rates), environmental features (e.g., organic matter thermodynamics), and emergent ecosystem function. Our primary aim was to evaluate the hypothesized relationships that comprise the conceptual framework and contrast outcomes from the whole and putatively active bacterial and archaeal communities. Throughout the system we found threshold-like responses to the duration of desiccation. Membership of the putatively active community – but not the whole bacterial and archaeal community – responded due to enhanced deterministic selection (an emergent community property). Concurrently, the thermodynamic properties of organic matter (OM) became less favorable for oxidation (an environmental component), and respiration decreased (a microbial process). While these responses were step functions of desiccation, we found that in deterministically assembled active communities, respiration was lower and thermodynamic properties of OM were less favorable. Placing the results in context of our conceptual framework points to previously unrecognized internal feedbacks that are initiated by disturbance and mediated by thermodynamics and that cause the impacts of disturbance to be dependent on the history of disturbance.

59 BASIC BIOLOGICAL SCIENCES↗

Conceptual Model of Offshore Wind Environmental Risk Evaluation System

In this report we describe the development of the Environmental Risk Evaluation System (ERES), a risk-informed analytical process for estimating the environmental risks associated with the construction and operation of offshore wind energy generation projects. The development of ERES for offshore wind is closely allied to a concurrent process undertaken to examine environmental effects of marine and hydrokinetic (MHK) energy generation, although specific risk-relevant attributes will differ between the MHK and offshore wind domains. During FY10, a conceptual design of ERES for offshore wind will be developed. The offshore wind ERES mockup described in this report will provide a preview of the functionality of a fully developed risk evaluation system that will use risk assessment techniques to determine priority stressors on aquatic organisms and environments from specific technology aspects, identify key uncertainties underlying high-risk issues, compile a wide-range of data types in an innovative and flexible data organizing scheme, and inform planning and decision processes with a transparent and technically robust decision-support tool. A fully functional version of ERES for offshore wind will be developed in a subsequent phase of the project.

17 WIND ENERGY↗

Scaling and Benchmarking an Evolutionary Algorithm for Constructing Biophysical Neuronal Models

Single neuron models are fundamental for computational modeling of the brain's neuronal networks, and understanding how ion channel dynamics mediate neural function. A challenge in defining such models is determining biophysically realistic channel distributions. Here, we present an efficient, highly parallel evolutionary algorithm for developing such models, named NeuroGPU-EA. NeuroGPU-EA uses CPUs and GPUs concurrently to simulate and evaluate neuron membrane potentials with respect to multiple stimuli. We demonstrate a logarithmic cost for scaling the stimuli used in the fitting procedure. NeuroGPU-EA outperforms the typically used CPU based evolutionary algorithm by a factor of 10 on a series of scaling benchmarks. We report observed performance bottlenecks and propose mitigation strategies. Finally, we also discuss the potential of this method for efficient simulation and evaluation of electrophysiological waveforms.

59 BASIC BIOLOGICAL SCIENCES↗

C-Myc regulates substrate oxidation patterns during early pressure-overload hypertrophy

Pressure overload cardiac hypertrophy alters substrate metabolism. Prior work showed that myocardial inactivation of c-Myc (Myc) attenuated hypertrophy and decreased expression of glycolytic genes after aortic constriction. Accordingly, we hypothesize that Myc regulates substrate preferences for the citric acid cycle during pressure overload hypertrophy from transverse aortic constriction (TAC) and that these metabolic changes impact cardiac function and growth. To test this hypothesis, we subjected FVB mice with cardiac specific, inducible Myc inactivation (MycKO-TAC) and non-transgenic littermates (Cont-TAC) to transverse aortic constriction (n=7/group). A separate group underwent sham surgery (Sham, n=5). After two weeks, function was measured in isolated working hearts along with substrate fractional contributions to the citric acid cycle by using perfusate with 13C labeled mixed fatty acids, lactate, ketones and unlabeled glucose and insulin. Western blots were used to evaluate metabolic enzymes. Cardiac function was similar between groups after TAC although +dP/dT and -dP/dT trended towards improvement in MycKO-TAC versus Cont-TAC. Compared to Sham, Cont-TAC had increased free fatty acid fractional contribution with a concurrent decrease in unlabeled (presumably glucose) contribution. Myc inactivation (MycKO-TAC) inhibited these metabolic changes. Hypertrophy in general increased protein levels of PKM2; however this change was not linked to Myc status. Protein post-translation modification by O-GlcNAc was significantly greater in Cont-TAC versus both Sham and MycKO-TAC. In conclusion, Myc regulates substrate utilization during early pressure overload hypertrophy. Our results show that the metabolic switch during hypertrophy is not necessary to maintain cardiac function, but it may be important mechanism to promote cardiomyocyte growth. Myc also regulates protein O-GlcNAcylation during hypertrophy.

59 BASIC BIOLOGICAL SCIENCES↗

A Case for Optimistic Coordination in HPC Storage Systems

High-performance computing (HPC) storage systems rely on access coordination to ensure that concurrent updates do not produce incoherent results. HPC storage systems typically employ pessimistic distributed locking to provide this functionality in cases where applications cannot perform their own coordination. This approach, however, introduces significant performance overhead and complicates fault handling. In this work we evaluate the viability of optimistic conditional storage operations as an alternative to distributed locking in HPC storage systems. We investigate design strategies and compare the two approaches in a prototype object storage system using a parallel read/modify/write benchmark. Our prototype illustrates that conditional operations can be easily integrated into distributed object storage systems and can outperform standard coordination primitives for simple update workloads. Our experiments show that conditional updates can achieve over two orders of magnitude higher performance than pessimistic locking for some parallel read/modify/write workloads.

Carns, Philip↗

TU-C-17A-12: Towards a Passively Optimized Phase-Space Monte Carlo (POPMC) Treatment Planning Method: A Proof of Principle

Purpose: The advent of on-line/off-line adaptive, and biologically-conformal radiation therapy has led to a need for treatment planning solutions that utilize voxel-specific penalties, requiring optimization over a large solution space that is performed quickly, and the dose in each voxel calculated accurately. This work proposes a “passive” optimization framework, which is executed concurrently during Monte Carlo dose calculation, evaluating the cost/benefit of each history during transport, and creates a passively optimized fluence map. Methods: The Monte Carlo code Geant4 v9.6 was used for this study. The standard voxel geometry implementation was modified to support the passive optimization framework, with voxel-specific optimization parameters. Dose-benefit functions, which will increase a particle history’s weight upon dose deposition, were defined in a central collection of voxels to effectively create target structures. Histories that deposit energy to voxels are reweighted based on a voxel’s dose multiplied by its cost/benefit value. Upon full termination of each history, the dose contributions of that history are reweighted to reflect a contribution proportional to the history’s final weight. A parallel-planar 1.25 MeV photon fluence is transported through the geometry, and re-weighted at each dose deposition step. The resulting weight is tallied with the incident spatial and directional coordinates in a phase-space distribution. Results: A uniform incident fluence was reweighted during MC dose calculations to create an optimized fluence map which would generate dose profiles in target volumes that exhibit the same dose characteristics as the prescribed optimization parameters. An optimized dose profile, calculated concurrently with the phase-space, reflects the resulting dose distribution. Conclusion: This study demonstrated the feasibility of passively optimizing an incident fluence map during Monte Carlo dose calculations. The flexibility of the voxel-specific optimization framework allows a variety and combination of optimization parameters to be calculated for each voxel at every transportation step. This work is partially supported by Varian. This work is partially supported by the NIH.

07 ISOTOPE AND RADIATION SOURCES↗

WE-AB-202-02: Incorporating Regional Ventilation Function in Predicting Radiation Fibrosis After Concurrent Chemoradiotherapy for Lung Cancer

Purpose: To investigate the incorporation of pre-therapy regional ventilation function in predicting radiation fibrosis (RF) in stage III non-small-cell lung cancer (NSCLC) patients treated with concurrent thoracic chemoradiotherapy. Methods: 37 stage III NSCLC patients were retrospectively studied. Patients received one cycle of cisplatin-gemcitabine, followed by two to three cycles of cisplatin-etoposide concurrently with involved-field thoracic radiotherapy between 46 and 66 Gy (2 Gy per fraction). Pre-therapy regional ventilation images of the lung were derived from 4DCT via a density-change-based image registration algorithm with mass correction. RF was evaluated at 6-months post-treatment using radiographic scoring based on airway dilation and volume loss. Three types of ipsilateral lung metrics were studied: (1) conventional dose-volume metrics (V20, V30, V40, and mean-lung-dose (MLD)), (2) dose-function metrics (fV20, fV30, fV40, and functional mean-lung-dose (fMLD) generated by combining regional ventilation and dose), and (3) dose-subvolume metrics (sV20, sV30, sV40, and subvolume mean-lung-dose (sMLD) defined as the dose-volume metrics computed on the sub-volume of the lung with at least 60% of the quantified maximum ventilation status). Receiver operating characteristic (ROC) curve analysis and logistic regression analysis were used to evaluate the predictability of these metrics for RF. Results: In predicting airway dilation, the area under the ROC curve (AUC) values for (V20, MLD), (fV20, fMLD), and (sV20, and sMLD) were (0.76, 0.70), (0.80, 0.74) and (0.82, 0.80), respectively. The logistic regression p-values were (0.09, 0.18), (0.02, 0.05) and (0.004, 0.006), respectively. With regard to volume loss, the corresponding AUC values for these metrics were (0.66, 0.57), (0.67, 0.61) and (0.71, 0.69), and p-values were (0.95, 0.90), (0.43, 0.64) and (0.08, 0.12), respectively. Conclusion: The inclusion of regional ventilation function improved predictability of radiation fibrosis. Dose-subvolume metrics provided a promising method for incorporating functional information into the conventional dose-volume parameters for outcome assessment.

60 APPLIED LIFE SCIENCES↗

Radiosensitization of Chemotherapy-Refractory, Locally Advanced or Locally Recurrent Breast Cancer With Trastuzumab: A Phase II Trial

Purpose: Trastuzumab (Herceptin), an anti-human epidermal growth factor receptor 2 (HER2) antibody, has been shown to be an effective radiosensitizer in preclinical studies. The present Phase II trial evaluated trastuzumab plus radiotherapy in patients with HER2-positive, chemotherapy-refractory, locally advanced or locoregionally recurrent breast cancer. Methods and Materials: Eligible patients had measurable disease, normal cardiac function, and biopsy-confirmed residual HER2-positive disease. Patients received weekly trastuzumab (2 mg/kg intravenously), concurrent with radiotherapy (50 Gy) to the breast and regional lymph nodes for 5 weeks. If feasible, surgery followed radiotherapy. The primary endpoint was safety, and the secondary endpoint was efficacy (pathologic response and interval to symptomatic local progression). Results: Of the 19 patients enrolled, 7 were ineligible and received radiotherapy alone and 12 received therapy per protocol. Of these 12 patients, 11 had a Stage T4 diagnosis. Grade 3 toxicities included skin (n = 2) and lymphopenia (n = 1). One patient experienced delayed wound healing after surgery. No patients developed symptomatic cardiac dysfunction. Of the 7 patients who had undergone mastectomy, 3 (43%) had a substantial pathologic response (complete response or microscopic residual disease), significantly more than a comparison cohort (2 of 38 or 5%, p = .02). The median interval to symptomatic local progression was not reached. The median overall survival was 39 months. Conclusion: This is the first prospective trial providing evidence for a radiosensitizing effect of trastuzumab in breast cancer. The combination of trastuzumab and radiotherapy was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Phase 2 Trial of Reirradiation With Stereotactic Body Radiation Therapy Plus Cetuximab in Patients With Previously Irradiated Recurrent Squamous Cell Carcinoma of the Head and Neck

Purpose: Salvage options for unresectable locally recurrent, previously irradiated squamous cell carcinoma of the head and neck (rSCCHN) are limited. Although the addition of reirradiation may improve outcomes compared to chemotherapy alone, significant toxicities limit salvage reirradiation strategies, leading to suboptimal outcomes. We therefore designed a phase 2 protocol to evaluate the efficacy of stereotactic body radiation therapy (SBRT) plus cetuximab for rSCCHN. Methods and Materials: From July 2007 to March 2013, 50 patients >18 years of age with inoperable locoregionally confined rSCCHN within a previously irradiated field receiving ≥60 Gy, with a Zubrod performance status of 0 to 2, and normal hepatic and renal function were enrolled. Patients received concurrent cetuximab (400 mg/m{sup 2} on day −7 and then 250 mg/m{sup 2} on days 0 and +8) plus SBRT (40-44 Gy in 5 fractions on alternating days over 1-2 weeks). Primary endpoints were 1-year locoregional progression-free survival and National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0 graded toxicity. Results: Median follow-up for surviving patients was 18 months (range: 10-70). The 1-year local PFS rate was 60% (95% confidence interval [CI]: 44%-75%), locoregional PFS was 37% (95% CI: 23%-53%), distant PFS was 71% (95% CI: 54%-85%), and PFS was 33% (95% CI: 20%-49%). The median overall survival was 10 months (95% CI: 7-16), with a 1-year overall survival of 40% (95% CI: 26%-54%). At last follow-up, 69% died of disease, 4% died with disease, 15% died without progression, 10% were alive without progression, and 2% were alive with progression. Acute and late grade 3 toxicity was observed in 6% of patients respectively. Conclusions: SBRT with concurrent cetuximab appears to be a safe salvage treatment for rSCCHN of short overall treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent targeting of nitrosative stress-PARP pathway corrects functional, behavioral and biochemical deficits in experimental diabetic neuropathy

Peroxynitrite mediated nitrosative stress, an indisputable initiator of DNA damage and overactivation of poly(ADP-ribose) polymerase (PARP), a nuclear enzyme activated after sensing DNA damage, are two crucial pathogenetic mechanisms in diabetic neuropathy. The intent of the present study was to investigate the effect of combination of a peroxynitrite decomposition catalyst (PDC), FeTMPyP and a PARP inhibitor, 4-ANI against diabetic peripheral neuropathy. The end points of evaluation of the study included motor nerve conduction velocity (MNCV) and nerve blood flow (NBF) for evaluating nerve functions; thermal hyperalgesia and mechanical allodynia for assessing nociceptive alterations, malondialdehyde and peroxynitrite levels to detect oxidative stress-nitrosative stress; NAD concentration in sciatic nerve to assess overactivation of PARP. Additionally immunohistochemical studies for nitrotyrosine and Poly(ADP-ribose) (PAR) was also performed. Treatment with the combination of FeTMPyP and 4-ANI led to significant improvement in nerve functions and pain parameters and also attenuated the oxidative-nitrosative stress markers. Further, the combination also reduced the overactivation of PARP as evident from increased NAD levels and decreased PAR immunopositivity in sciatic nerve microsections. Thus, it can be concluded that treatment with the combination of a PDC and PARP inhibitor attenuates alteration in peripheral nerves in diabetic neuropathy (DN).

60 APPLIED LIFE SCIENCES↗

Implementation and experimental results of 4D tumor tracking using robotic couch

Purpose: This study presents the implementation and experimental results of a novel technique for 4D tumor tracking using a commercially available and commonly used treatment couch and evaluates the tumor tracking accuracy in clinical settings. Methods: Commercially available couch is capable of positioning the patient accurately; however, currently there is no provision for compensating physiological movement using the treatment couch in real-time. In this paper, a real-time couch tracking control technique is presented together with experimental results in tumor motion compensation in four dimensions (superior-inferior, lateral, anterior-posterior, and time). To implement real-time couch motion for tracking, a novel control system for the treatment couch was developed. The primary functional requirements for this novel technique were: (a) the treatment couch should maintain all previous/normal features for patient setup and positioning, (b) the new control system should be used as a parallel system when tumor tracking would be deployed, and (c) tracking could be performed in a single direction and/or concurrently in all three directions of the couch motion (longitudinal, lateral, and vertical). To the authors' best knowledge, the implementation of such technique to a regular treatment couch for tumor tracking has not been reported so far. To evaluate the performance of the tracking couch, we investigated the mechanical characteristics of the system such as system positioning resolution, repeatability, accuracy, and tracking performance. Performance of the tracking system was evaluated using dosimetric test as an endpoint. To investigate the accuracy of real-time tracking in the clinical setting, the existing clinical treatment couch was replaced with our experimental couch and the linear accelerator was used to deliver 3D conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment plans with and without tracking. The results of radiation dose distribution from these two sets of experiments were compared and presented here. Results: The mechanical accuracies were 0.12, 0.14, and 0.18 mm in X, Y, and Z directions. The repeatability of the desired motion was within {+-}0.2 mm. The differences of central axis dose between the 3D-CRT stationary plan and two tracking plans with different motion trajectories were 0.21% and 1.19%. The absolute dose differences of both 3D tracking plans comparing to the stationary plan were 1.09% and 1.20%. Comparing the stationary IMRT plan with the tracking IMRT plan, it was observed that the central axis dose difference was -0.87% and the absolute difference of both IMRT plans was 0.55%. Conclusions: The experimental results revealed that the treatment couch could be successfully used for real-time tumor tracking with a high level of accuracy. It was demonstrated that 4D tumor tracking was feasible using existing couch with implementation of appropriate tracking methodology and with modifications in the control system.

60 APPLIED LIFE SCIENCES↗

Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received {>=}60 Gy radio(chemo)therapy for primary NSCLC in 1998-2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient's preradiation value at the following time intervals: 0-4 (T1), 5-8 (T2), and 9-12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy or intensity-modulated radiotherapy, may decrease the pulmonary impairment through greater lung sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗