Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Concentrating Solar Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Vascular Carbon/Carbon composites for concentrated solar power

Due to their exceptional mechanical and thermal properties under high temperature conditions, for the first time, a novel vascular (embedded channels) Carbon/Carbon (C/C) composite was developed for use as a modular concentrated solar power (CSP) gas receiver. The fabrication process involves the combination of the vaporization of sacrificial component (VaSC) technique with conventional methods to produce C/C composites with well preserved channels. Different heat treatments were evaluated together with X-ray diffraction (XRD) analysis to determine optimal fabrication conditions that maintains the material and channel’s integrity. Mechanical testing confirms that structural integrity is maintained, with statistical analyses indicating no compromise in flexural strength or modulus. Furthermore, this research introduces an innovative pathway for efficient CSP gas receivers, which can bridge the gap towards improved energy generation efficiency in next-gen CSP plants through higher operating temperatures with the use of C/C composites.

14 SOLAR ENERGY↗

Multi-Objective Optimization of a Bi-Metal High-Temperature Recuperator for Application in Concentrating Solar Power

Supercritical CO 2 closed Brayton cycles are a major candidate for future power cycle designs in concentrating solar power applications, with high-temperature recuperators playing an essential role in realizing their high thermal efficiency. Here, printed circuit heat exchangers (PCHEs) are often chosen for this role due to their thermal-hydraulic and mechanical performance at high temperatures and pressures, all while remaining compact. However, PCHEs can be costly because of the high-performance materials demanded in these applications, and the heat exchanger internal geometry is restricted by their manufacturing process. Additively manufactured heat exchangers can address both of these shortcomings. This work proposes a modular bi-metal high-temperature recuperator with integrated headers to be produced with additive manufacturing. Beginning with existing PCHE channel geometries, a 1D heat exchanger model is developed. Then, multi-objective optimization is used to maximize the heat transfer effectiveness of a lab-scale device while limiting its size. Two distinct channel geometries emerge from the optimization. Optimal designs achieve up to 88% effectiveness with negligible pressure drop. Deterioration of effectiveness due to axial conduction of heat in the heat exchanger walls is found to be a notable problem for lab-scale PCHEs, and the optimal designs obtained here minimize its detrimental effects. A sensitivity analysis reveals that the effectiveness of the recuperator is much less sensitive to variation in mass flowrate in off-design operation when axial conduction is significant, while increasing the length of the device easily increases effectiveness.

14 SOLAR ENERGY↗

Using concentrating-solar-power plants as economic carbon-free capacity resources

Deep decarbonization of electricity systems raises concerns about the need for generating capacity that can maintain reliable energy supply. Given this concern, we explore the ability of concentrating-solar-power plants with thermal energy storage to provide a carbon-free source of such capacity. We develop an approach to assessing the capacity contribution of concentrating-solar-power plants that considers future systems. Such considerations are important, because of potential differences in net-load patterns compared to today (e.g., due to higher renewable-energy penetrations). Using historical data spanning an 18-year period, we demonstrate that concentrating-solar-power plants with thermal energy storage can provide this necessary capacity with little impact on their financial viability. We examine the impact of myopic decisions and imperfect foresight of future system conditions on the operation of concentrating-solar-power plants and the resultant impact on their capacity contributions. We find that imperfect foresight can have limited impacts on such a use of concentrating-solar-power plants, so long as proper forecasting techniques are developed and used. Overall, our work shows that concentrating-solar-power plants with thermal energy storage may have a role to play in delivering reliable electricity supply in a decarbonized energy system.

14 SOLAR ENERGY↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Analysis and Optimization of the Recompression Cycle with High Temperature Recuperator Bypass for Concentrating Solar Power Applications

This work analyzes the sCO2 recompression with high temperature recuperator (HTR) bypass power cycle for use in concentrating solar power (CSP) systems. CSP operation differs from other thermal power plants in that CSP must balance between maximizing the heat transfer fluid (HTF) temperature difference and maximizing the cycle thermal efficiency, which typically are inversely related. Large HTF temperature differences reduce the size and cost of thermal energy storage (TES), improve the solar receiver efficiency, and require lower mass flow rates that reduce pumping power required to elevate the HTF to the receiver. The recompression cycle with HTR bypass potentially offers improved thermal efficiency with larger HTF temperature differences as compared to the recompression cycle, and it has fewer turbomachinery components than the partial cooling cycle. The recompression with HTR bypass cycle adds a second lower temperature primary heat exchanger which transfers heat from the HTF to the fraction of sCO2 flow that bypasses the HTR. We developed a model to compare the recompression with HTR bypass cycle to the recompression and partial cooling cycles. A sweep of design parameters including bypass fraction, recompression fraction, recuperator conductance, and pressure ratio is used to form a pareto-optimal front with the cycle thermal efficiency and HTF temperature difference as objectives. An optimization routine has also been developed to find optimal design point parameters for a target HTF temperature difference. The performance of the recompression with HTR bypass cycle is compared with recompression and partial cooling cycles.

concentrating solar power↗

UHTC-TPMS Heat Exchangers for Concentrating Solar Power Applications with Thermal Energy Storage in Molten Chlorides

Concentrating solar power (CSP) plants convert energy from sunlight into electricity. Generally, a heliostat field is used to reflect sunlight and concentrate it onto a receiver, which heats the receiver and/or the media flowing through it. A flow loop transports the media through the system to a heat exchanger before returning the media back to the receiver to be reheated. The heat extracted by the heat exchanger is then converted into electricity using a conventional heat engine.

14 SOLAR ENERGY↗

Concentrated solar power generation using solar receivers

Inventive concentrated solar power systems using solar receivers, and related devices and methods, are generally described. Low pressure solar receivers are provided that function to convert solar radiation energy to thermal energy of a working fluid, e.g., a working fluid of a power generation or thermal storage system. In some embodiments, low pressure solar receivers are provided herein that are useful in conjunction with gas turbine based power generation systems.

Anderson, Bruce N.↗

Investigation of Best-Practices and Computationally Inexpensive Radiative Exchange Models for Discrete Element Method Modeling of Aluminosilicate Particles in Concentrating Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrating solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrating solar power environments. In this study, coupled experimental and numerical slump testing of aluminosilicate particles was performed and computationally efficient radiative exchange models were evaluated to establish best-practices for discrete element method models for concentrating solar power environments. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Existing modeling limitations and computationally-efficient multi-modal heat transfer models were evaluated using Aspherix®, a commercial discrete element method software. High-temperature (< 1073 K) slump testing of aluminosilicate particles was performed to investigate the deviation between experimentally-observed and numerically-predicted angles of repose introduced by computation-time reduction practices including the relaxation of the particle elastic modulus and coarse-graining. Coarse-graining is used to use a single modeled particle that is representative of a collection of smaller particles, decreasing the computational cost at the expense of geometric accuracy. Additionally, relaxation of the elastic modulus is used to reduce computational time at the expense of an increased, modeled particle overlap. Prior studies have determined that aluminosilicate particles retain a high elastic modulus at high temperatures (< 1073 K), requiring small simulation timesteps to ensure resolved contact forces resemble appropriate solid mechanics. A parametric study was performed to evaluate the influence of computation time improvements on the deviation between experimental and modeled angle of repose across high temperatures < 1073 K. Additionally, numerical case studies were performed on candidate particle systems at varying porosities and temperatures. These studies were performed to investigate the influence of computationally-efficient radiative-exchange modeling methods coupled to Aspherix® on modeled accuracy and computation time. The recently-developed distance-based approximation was evaluated in estimating radiative exchange between particles and participating surfaces located in close proximity. The distance based approximation was developed to use tabulated estimates of the radiative distribution factor between individual particles and surfaces in close proximity (< 40 particle radii). These methods were expanded to the aluminosilicate particles of interest, including the influence of particle size distributions. To capture radiative exchange between particles and surfaces not in close proximity (> 40 particle radii) and to capture the absorption of directional irradiation from concentrating solar resources, a volumetrically-averaged radiative distribution factor was calculated between the modeled granular flow and surfaces using Monte Carlo ray-tracing for participating media. Volume-averaged absorption and scattering coefficients were predicted using a volumetric discretization of the modeled domain with monodisperse approximations based on geometric optics and experimentally-determined scattering phase functions for aluminosilicate particles.

14 SOLAR ENERGY↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

The material challenges of the next generation of concentrated solar power

This is an introductory seminar about the cleantech-to-market pathway with a focus on material innovation in Concentrated Solar Power. This seminar will first lay out the business model of cleantech companies to identify the players in technical innovation. With a summary of the desires of the major player, this seminar will dive into the possibility, potential, and challenges of next-generation Concentrated Solar Power to answer these desires, followed by a detailed discussion on the material challenges. The scope of our project “Scalable, Infiltration-Free Ceramic Matrix Composite for the molten salt receiver” will be presented as one potential way to solve these challenges. In the end, this seminar will present some job opportunities to inspire the audience to participate in cleantech innovation.

42 ENGINEERING↗

Coupled Experimental and High-Temperature Discrete-Element Method Modeling Studies of Aluminosilicate Particle Handling in Concentrated Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrated solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrated solar power environments. Coupled experimental and numerical studies of aluminosilicate particles in rotary kilns and dense particle curtains were performed for bulk temperatures up to 1073 K. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Temperature, spatial, and velocity profile data were extracted from experimental runs using embedded K-type thermocouple probes and particle image velocimetry techniques. Experimental and numerical studies were compared using spatial temperature profiles, velocity fields, and shape profiles of the bulk, granular flows. Numerical models were developed using commercially available discrete element method modeling software, Aspherix®. Existing Aspherix® functionality was expanded by introducing coupled radiative exchange modeling tools. The laboratory-scale rotary kiln was developed to investigate the steady-state heat and mass transfer performance of aluminosilicate particles based on particle type, bulk handling temperature, and wall roughness. The rotational speed of the rotary kiln was varied to control the relative impact of collisional and frictional effects upon the granular flow behavior. Heat and mass transfer performance was categorized based on the Froude number and the observed flow regimes of slipping, rolling, cascading, and centrifuging. Coupled discrete element method modeling studies were used to evaluate the effects of temperature-dependent, particulate mechanical properties upon bulk flow behavior and upon the relative effects of radiative, advective, and/or conductive heat transfer. A high-temperature (< 1073 K) falling particle curtain was similarly fabricated to investigate the heat and mass transfer performance of aluminosilicate particles in particle handling situations dominated by inter-particle collisions. The impact of particle type, flow preheat temperatures (< 1073K), and bulk mass flow rates were investigated upon the particle curtain shape, temperature, and velocity profiles. Coupled discrete element method modeling studies were performed to evaluate the varying impact of temperature-dependent, particulate mechanical properties on the bulk flow behavior and the temperature profile of the particle curtain.

14 SOLAR ENERGY↗

Characterizing and improving the performance of molten-salt-steam heat exchangers in concentrating solar power plants

Shell-and-tube heat exchangers (HXs) for steam generation from molten salts in concentrating solar power (CSP) plants experience thermal fatigue due to significant temperature gradients and inherent transient operation. Molten salt-steam HX design lifespans exceed actual lifespans, and, as a consequence, designers overpredict plant profitability and operators neglect appropriate prescriptions to optimize these lifetimes. Here, this study refines HX lifespan estimates with data benchmarked against thermal-fluid mechanical modeling of stress and accumulated fatigue. Reduced-order thermal models of the molten salt-steam, shell-and-tube evaporator and superheater predict transient temperature profiles along the two HXs salt-steam flow paths. The modeled evaporator and superheater temperature profiles enable assessment of cyclic stresses within the HX tubesheets, where molten-salt HX failures are most common. Evaporator and superheater performance data from a current 110 MW elec commercial CSP plant provide a basis for validating the reduced-order HX models. HX life predictions derived from stochastic failure distributions serve as inputs for simulating and optimizing existing plant operations. The impact of the updated lifespans on overall plant revenue depends on operating scenarios. This study suggests that typical ramping rates for a CSP plant with a high-temperature Rankine cycle result in an evaporator and superheater life of approximately 10 and 25 years, respectively, compared to the design target of 30 years. Reduced HX lifespans decrease operational plant revenue on average by 4.6-5.1%. Furthermore, there may be as many as four HX replacements over the 30-year lifetime of the plant; and, purchase agreement loss due to failure to meet contractual production requirements can have ramifications that include the risk of bankruptcy.

14 SOLAR ENERGY↗

The value of concentrating solar power in ancillary services markets

Ancillary services, such as spinning reserves, can provide grid reliability and contribute to profitability of an energy resource. We exercise an existing dispatch optimization model to estimate the profitability of a concentrating solar power plant by incorporating the sale of spinning reserves in the ancillary service market using the National Renewable Energy Laboratory's System Advisor Model to simulate operations within a 72-h rolling horizon framework. Assuming a price-taker approach with day-ahead energy and spinning reserve prices from both the California Independent System Operator and the Electricity Reliability Council of Texas, we find that selling spinning reserves in addition to electric energy increases plant profitability by up to 7% with perfect knowledge of day-ahead pricing and solar resource availability. Here, this finding suggests that spinning reserve markets provide significant value streams to concentrating solar power plants that can leverage thermal energy storage to offer reliable production in the short-to-medium term.

14 SOLAR ENERGY↗

Concentrating Solar Power (CSP) Plant Optimization Study for the California Power Market (CalCSP)

In the United States, many states are implementing goals to achieve 100% carbon free power generation by 2050 or sooner. California has one of the more aggressive goals to achieve 100% carbon free generation of its retail power sales by 2045. California has excellent solar resources, but to accomplish this goal, California’s power utilities will need new zero carbon resources that can replace the natural gas units that they currently rely on for suppling power at night. Appropriately configured concentrating solar power plants with thermal energy storage are an option to serve this nighttime load. These plants would be designed to take advantage of CSP’s low-cost thermal energy storage and collect and store energy during the day and then be dispatched to produce power at night. The U.S. Department of Energy has funded a study to identify the design of a CSP plant that optimally meets the evolving CA grid needs. This will be done by taking a fresh look at how CSP technologies can best be designed to meet the emerging nighttime market for carbon free power generation or zero-carbon firm resources. The paper provides an overview of the study and present preliminary findings on the California power market requirements, CSP configurations, technoeconomic analysis, siting opportunities, and key issues for CSP deployment in this market.

Price, Hank (ORCID:0000000267049197)↗