Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cold plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Adding through-bolt holes to pin-fin cold plates

Spot-welding technique is less expensive than secondary-brazing and electron-beam methods. With procedure, standard plates can be modified in quantity for various mounting configurations without need for special tooling.

Ruppe, E. P.

Repairing pin-fin cold plates

Inexpensive technique avoids high temperatures that deform thin stainless steel plates. Because repair disks have small diameters, repaired area can sustain greater loads that larger unsupported areas of faceplate.

Ruppe, E. P.

Monogroove cold plate

The coolant fluid evaporated in a compact heat absorbing panel utilizing monogroove heat pipes in a pumped two-phase system is replenished through a liquid inlet control valve under the control of an ultrasonic liquid presence detector which is connected to the panel. The detector maintains the desired liquid quantity in the panel's liquid coolant channels, thereby dynamically responding to varying heat loads.

Edelstein, Fred

Flow boiling with enhancement devices for cold plate coolant channel design

A research program to study the effect of enhancement devices on flow boiling heat transfer in coolant channels, which are heated either from the top side or uniformly, is discussed. Freon 11 is the working fluid involved. The specific objectives are: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls or with both a twisted tape and spiral finned walls, (2) examine the effect channel diameter (and the length-to-diameter aspect ratio) variations for the smooth wall channel, and (3) develop an improved data reduction analysis.

Boyd, Ronald D., Sr.

Flow boiling with enhancement devices for cold plate coolant channel design

The effects of enhancement devices on flow boiling heat transfer in circular coolant channels, which are heated over a fraction of their perimeters, are studied. The variations were examined in both the mean and local (axial, and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls or with both a twisted tape and spiral finned walls. Improvements were initiated in the present data reduction analysis. These efforts should lead to the development of heat transfer correlations which include effects of single side heat flux and enhancement device configuration. It is hoped that a stage will be set for the study of heat transfer and pressure drop in single sided heated systems under zero gravity conditions.

Boyd, Ronald D.

Flow boiling with enhancement devices for cold plate coolant channel design

The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.

Boyd, Ronald D., Sr.

Flow boiling with enhancement devices for cold plate coolant channel design

Future space exploration and commercialization will require more efficient heat rejection systems. For the required heat transfer rates, such systems must use advanced heat transfer techniques. Forced two phase flow boiling heat transfer with enhancements falls in this category. However, moderate to high quality two phase systems tend to require higher pressure losses. This report is divided into two major parts: (1) Multidimensional wall temperature measurement and heat transfer enhancement for top heated horizontal channels with flow boiling; and (2) Improved analytical heat transfer data reduction for a single side heated coolant channel. Part 1 summarizes over forty experiments which involve both single phase convection and flow boiling in a horizontal channel heated externally from the top side. Part 2 contains parametric dimensionless curves with parameters such as the coolant channel radius ratio, the Biot number, and the circumferential coordinate.

Boyd, Ronald D.

Modular Cooling Components

Three modular heat-transfer components designed for use together or separately. Simple mechanical connections facilitate assembly of these and related heat-transfer components into cooling systems of various configurations, such as to cool laboratory equipment rearranged for different experiments. Components are clamp-on cold plate, cold plate attached to flexible heat pipe, and thermal-bus receptacle. Clamp-on cold plate moved to any convenient location for attachment of equipment cooled by it, then clamped onto thermal bus. Heat from equipment conducted through plate and into coolant. Thermal-bus receptacle integral with thermal bus. Includes part of thermal bus to which clamp-on cold plate attached, plus tapered socket into which condenser end of flexible heat pipe plugged. Thermal-bus receptacle includes heat-pipe wick structure using coolant in bus to enhance transfer of heat from cold plate.

Eastman, G. Yale

Microgravity condensing heat exchanger

A heat exchanger having a plurality of heat exchanging aluminum fins with hydrophilic condensing surfaces which are stacked and clamped between two cold plates. The cold plates are aligned radially along a plane extending through the axis of a cylindrical duct and hold the stacked and clamped portions of the heat exchanging fins along the axis of the cylindrical duct. The fins extend outwardly from the clamped portions along approximately radial planes. The spacing between fins is symmetric about the cold plates, and are somewhat more closely spaced as the angle they make with the cold plates approaches 90.degree.. Passageways extend through the fins between vertex spaces which provide capillary storage and communicate with passageways formed in the stacked and clamped portions of the fins, which communicate with water drains connected to a pump externally to the duct. Water with no entrained air is drawn from the capillary spaces.

Thomas, Christopher M.

Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature

An apparatus allows the measurement of the thermal conductance across a thin sample clamped between metal plates, including thermal boundary resistances. It allows in-situ variation of the clamping force from zero to 30 lb (133.4 N), and variation of the sample temperature between 40 and 300 K. It has a special design feature that minimizes the effect of thermal radiation on this measurement. The apparatus includes a heater plate sandwiched between two identical thin samples. On the side of each sample opposite the heater plate is a cold plate. In order to take data, the heater plate is controlled at a slightly higher temperature than the two cold plates, which are controlled at a single lower temperature. The steady-state controlling power supplied to the hot plate, the area and thickness of samples, and the temperature drop across the samples are then used in a simple calculation of the thermal conductance. The conductance measurements can be taken at arbitrary temperatures down to about 40 K, as the entire setup is cooled by a mechanical cryocooler. The specific geometry combined with the pneumatic clamping force control system and the steady-state temperature control approach make this a unique apparatus.

Tuttle, James G.

Neural-Net Processed Characteristic Patterns for Measurement of Structural Integrity of Pressure Cycled Components

A neural-net inspection process has been combined with a bootstrap training procedure and electronic holography to detect changes or damage in a pressure-cycled International Space Station cold plate to be used for cooling instrumentation. The cold plate was excited to vibrate in a normal mode at low amplitude, and the neural net was trained by example to flag small changes in the mode shape. The NDE (nondestructive-evaluation) technique is straightforward but in its infancy; its applications are ad-hoc and uncalibrated. Nevertheless previous research has shown that the neural net can detect displacement changes to better than 1/100 the maximum displacement amplitude. Development efforts that support the NDE technique are mentioned briefly, followed by descriptions of electronic holography and neural-net processing. The bootstrap training procedure and its application to detection of damage in a pressure-cycled cold plate are discussed. Suggestions for calibrating and quantifying the NDE procedure are presented.

Decker, A. J.

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza