Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient of performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Thermodynamic analysis of a two-stage binary-fluid ejector heat pump water heater

Ejector heat pump water heaters (EHPWHs) could significantly increase the thermal efficiency of domestic water heating and reduce greenhouse gas emissions. This study addresses two major technical barriers to using EHPWHs in domestic water heating—low heating cycle coefficient of performance (COP) and low condensation temperatures—using binary fluid pairs as a working fluid in a two-stage ejector system. A comprehensive, geometry-free model of binary-fluid ejectors was built and validated to predict the entrainment ratios of binary-fluid ejectors. A thermodynamic model of a two-stage binary-fluid ejector EHPWH was built to predict the heating cycle COP of EHPWHs. The performance of the EHPWH was theoretically evaluated using HFE7000 and Novec649 as primary fluids and R600 and R1234ze(Z) as secondary fluids. HFE7000/R600 gave the highest heating cycle COP (i.e., 1.356) in producing domestic hot water at 60.0 °C. An optimum evaporation temperature of the primary fluid was identified for the maximum effective entrainment ratio and effective pressure lift ratio of two-stage ejectors. Here, the effective entrainment ratio of the two-stage ejector dominated the heating cycle COP of the EHPWH. Primary fluids with lower latent heats of evaporation and/or secondary fluids with higher latent heats of evaporation yielded higher heating cycle COPs of EHPWHs.

42 ENGINEERING↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Searching for Suitable Binary Fluid for an Ejector Heat Pump for Domestic Water Heating

Water heating is a major source of energy consumption in the U.S. residential sector. Heat pumps can significantly increase the energy efficiency of water heating. An ejector heat pump (EHP) is a novel, thermally driven heat pump that uses an ejector as a thermocompressor. Choosing suitable working fluids is critical in developing high-performance EHPs. Therefore, this research screens binary fluid pairs (BFPs) for EHPs to produce domestic hot water at a high coefficient of performance (COP). The criteria for screening BFP candidates for EHP water heaters (EHPWHs) are established, and BFP candidates are shortlisted. This study identifies HFE7000, Novec649, HFE7100, HFE7200, and HFE7500 for the primary fluids and RE170, R600a, R600, and R1234ze(Z) for the secondary fluids. The thermodynamic model is employed to investigate the performance of EHPWHs using the shortlisted BFPs under various operating parameters, including the evaporation pressure of the primary working fluid in the high-temperature evaporator and the condensation temperature. In conclusion, the highest heating-cycle COP of 1.328 is achieved by an EHPWH operating with HFE7000/R600 at a condenser temperature of 50 °C and a pressure of 1.69 MPa in the high-temperature evaporator.

42 ENGINEERING↗

Performance Analysis of High-Temperature Heat Pumps with Two-Phase Ejectors

A two-phase ejector recovers the energy in the refrigerant cycles’ throttling process, improving the coefficient of performance (COP) of high-temperature heat pumps (HTHPs). This study investigated the effects of the mixing pressure on the performance of two-phase ejectors and ejector-assisted HTHPs. A 1D theoretical model of a two-phase ejector was built to predict the internal fluid dynamics and evaluate ejector performance. A thermodynamic model of an ejector-assisted HTHP was built to evaluate the COP of HTHPs and the volumetric heating capacity of low-global warming potential refrigerants. The results demonstrate that an optimum mixing pressure in a two-phase ejector provides the best performance of a two-phase ejector and ejector-assisted HTHP. The optimum mixing pressure was slightly lower than the evaporation pressure. At this pressure, the two-phase flow in the ejector was subsonic. For ejector-assisted HTHPs using low–global warming potential refrigerants at a sink temperature of 120°C, temperature lift of 40°C, and subcooling of 10°C, a two-phase ejector has an average ejector efficiency of 0.334, and the COP and volumetric heating capacity were improved by 7.2% and 7.3%, respectively.

Wang, Pengtao↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Review of Dew Point Evaporative Cooling Technology for Air Conditioning Applications

Indirect evaporative cooling has the potential to significantly improve the natural environment. It follows from a significant reduction in electricity consumption in the hot period, and hence lower operating costs for cooling systems. This paper presents the current state of knowledge and research directions on dew point indirect evaporative cooling. It was found that researchers focus on the development of dew point indirect evaporative coolers (DPIEC) by improving its design, geometry, water distribution, and new porous materials implementation. To evaluate the performance of new types of DPIEC, different methods are used by the scientists. Finally, optimized devices are studied in terms of their performance in different systems, like hybrid and desiccant systems, considering different climate conditions. Potential directions of development of evaporative technologies were indicated, such as increasing the coefficient of performance of solid desiccant evaporative cooling systems, developing novel geometry, and efficient water distribution, including development of porous materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Performance Trade-off in thermoelectric air conditioning system with graded and constant material properties

Thermoelectric (TE) air cooling is a solid-state technology that has the potential to replace conventional vapor compression-based air conditioning. In this paper, we present a detailed system-level modeling for thermoelectric air conditioning system with position-dependent (graded) and constant material properties. Strategies for design optimization of the system are provided in terms of cost-performance trade-off. Realistic convection heat transfer at both sides of the system are taken into account in our modeling. Here, the effects of convection heat transfer coefficients, air flowrate, and thermoelectric material properties are investigated with varying key parameters such as TE leg thickness, module fill factor, and input current. Both constant material properties and graded properties are considered for the TE materials, and they are compared in terms of the degree of cooling, coefficient of performance (COP), and power consumption. For graded materials, we employ one-dimensional finite element methods to solve the coupled electrical and thermal current equations with arbitrary profile of material properties varying with position along the TE legs. We find that graded materials can enhance the degree of cooling, but only at the expense of COP, compared to the case of constant property materials. With constant material properties of ZT = 1 and relatively low electric current, the power consumption of TE coolers can be lower than those of conventional air conditioners at an equivalent cooling capacity. Considering additional advantages such as demand-flexible operation, low noise, and high scalability, thermoelectric cooling could be a competitive technology for future air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Moltensaltpropnet

MoltenSaltPropnet is a physics-informed machine learning framework that aims to predict the thermophysical properties of molten fluoride and chloride salt mixtures, which are crucial for the design and safety of Generation IV molten salt reactors. The code processes data from the Molten-Salt Thermal Properties Database (MSTDB-TP) and the Janz compendium, converting critically evaluated correlations into fast, differentiable surrogate models for density, viscosity, thermal conductivity, and heat capacity across 448 distinct salt systems. The implementation consists of several key components: 1. Data Curation: The code parses and cleans the raw data, normalizing elemental mole fractions and extracting relevant regression coefficients for various thermophysical properties. 2. Feature Engineering: It generates fixed-length numerical descriptors that encapsulate the composition and temperature, incorporating polynomial interaction terms and dimensionality-reduction techniques to optimize model performance. 3. Coefficient Learning: Four different machine learning architectures are employed: a deep residual network (ResNet), a Kolmogorov–Arnold network (KAN), a sparsity-inducing neural network (SNN), and classical regression models. Each model learns to predict coefficients that define the temperature-dependent correlations for the thermophysical properties. 4. Property Reconstruction: The predicted coefficients are used to compute temperature-dependent property values, ensuring positivity and monotonic trends through a composite loss function that enforces physical constraints. 5. User Interface: An open-source web application enables users to filter the database, train task-specific models, and visualize the results, allowing for rapid exploration of candidate salt mixtures. MoltenSaltPropnet bridges the gap between limited experimental data and high-fidelity reactor simulations, providing a powerful tool for researchers in the field of molten salt reactors and advanced nuclear energy systems.

Retamales, Mauricio Eduardo Tano [Idaho National L↗

Molecular Insight into Fluorocarbon Adsorption in Pore Expanded Metal–Organic Framework Analogs

The rapid growth in the global energy demand for space cooling requires the development of more efficient environmental chillers for which adsorption-based cooling systems can be utilized. Here, in this contribution, we explore sorbents for chiller use via a pore-engineering concept to construct analogs of the 1-dimensional pore metal–organic framework MOF-74 by using elongated organic linkers and stereochemistry control. The prepared pore-engineered MOFs show remarkable equilibrium adsorption of the selected fluorocarbon refrigerant that is translated to a modeled adsorption-based refrigeration cycle. To probe molecular level interactions at the origin of these unique adsorption properties for this series of Ni-MOFs, we combined in situ synchrotron X-ray powder diffraction, neutron powder diffraction, X-ray absorption spectroscopy, calorimetry, Fourier transform infrared techniques, and molecular simulations. Our results reveal the coordination of fluorine (of CH2F in R134a) to the nickel(II) open metal centers at low pressures for each Ni-MOF analog and provide insight into the pore filling mechanism for the full range of the adsorption isotherms. The newly designed Ni-TPM demonstrates exceptional R134a adsorption uptake compared to its parent microporous Ni-MOF-74 due to larger engineered pore size/volume. The application of this adsorption performance toward established chiller conditions yields a working capacity increase for Ni-TPM of about 400% from that of Ni-MOF-74, which combined with kinetics directly correlates to both a higher coefficient of performance and a higher average cooling capacity generated in a modeled chiller.

Zheng, Jian↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

A hybrid analytical and numerical model for cross-over and performance decay in a unit cell vanadium redox flow battery

Developing an accurate and efficient model for cross-over is critical for improving the long-term performance of redox flow batteries (RFBs). Here, this work presents a hybrid analytical and numerical model that combines a two-dimensional analytical solution to the active species, a one-dimensional analytical model for cross-over mechanisms, and a zero-dimensional numerical model for outlet concentrations of reactants. By comparing with experiment over 41 cycles (ca. 144 h), the model reported a mean voltage difference of 0.0089 V, mean time difference of 14 s per cycle (of 3.5 h), maximum relative difference for capacity and energy of 1.34% and 1.63%, respectively. The predicted mean concentrations for V 2+ , V 3+ , and VO$_{2}^{+}$ in membrane are 65%~77% of measured values from the literature. Upon validation, the model reproduced behaviors in electrolyte imbalance similar to those observed in experiments and numerical models, and revealed the control of cross-over, self-discharge, stoichiometry of side reactions, and Coulombic efficiency on electrolyte imbalance. The model also demonstrates excellent computational efficiency for simulating 41 cycles (around 37,000 points) within 3~4 s. The demonstrated efficiency and accuracy for predicting cross-over and its impacts on voltage, capacity&energy decay, membrane concentrations, and electrolyte imbalance makes it a reliable tool for optimizing RFBs’ long-term performance.

25 ENERGY STORAGE↗