Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Circulating Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Anion-Exchange-Membrane Electrolysis with Alkali-Free Water Feed

Hydrogen is a green and sustainable energy vector that can facilitate the large-scale integration of intermittent renewable energy, renewable fuels for heavy transport, and deep decarbonization of hard-to-abate industries. Anion-exchange-membrane water electrolyzers (AEM-WEs) have several achieved or expected competitive advantages over other electrolysis technologies, including the use of precious metal-free electrocatalysts at both electrodes, fluorine-free hydrocarbon-based ionomeric membranes and bipolar plates based on inexpensive materials. Contrasting the analogous proton-exchange-membrane system (PEM-WE), where pure water is circulated (no support electrolyte), the current generation of AEM-WEs necessitates the circulation of a dilute aqueous alkaline electrolyte for reaching high energy efficiency and durability. For several reasons, including but not limited to lower cost of balance-of-plant, lower operating cost and improved device's lifetime, achieving high cell efficiency and performance using an alkali-free water feed is highly desirable. In this review, we develop and build a foundational understanding of AEM-WEs operating with pure water, as well as discuss the effects of operating with natural water feeds like seawater. After a discussion of the possible advantages of pure-water-fed AEM-WEs, we cover the thermodynamic and kinetic processes involved in AEM-WE, followed by a detailed review of materials and components and their integration in the device. We highlight the influence of electrolyte composition and alkali/electrolyte-free feed on the membrane-electrode assembly, ionomers, electrocatalysts, porous transport layer, bipolar plates and operating configuration. We provide evidence for how the pure water feed engenders several issues related to the degradation of device components and propose mitigation strategies.

Electrodes↗

Experimental Study of Underground Heat Storage via Hydraulic Fractures

In this study, we present a laboratory setup to test the energy flow in the form of underground heat storage using hydraulic fractures, a so-called Fracture Thermal Energy Storage (FTES) system. In the experiment, de-ionized water is circulated under high pressure through steel tubing automatically heated to a target temperature. The fluid adjusts to the tubing temperature during its flow before entering a production well drilled into a 250 mm edge length block of Zimbabwe Gabbro. The warm fluid then circulates through a previously created hydraulic fracture at mid-height of the block to a production well drilled at the block periphery. External fracture appearances are sealed using an epoxy resin and the production well by a cork of polydimethylsiloxane. In this cork, tubing to an open outlet is glued. We demonstrated through the results of a preliminary heating experiment that we can transfer nearly all of the heat from the circulating fluid to the block. An efficient charging of the thermal battery is achieved. This first-order demonstration is currently under further improvement and serves as a knowledge basis for the upscaling of mid- to large-scale field implementation of FTES systems.

Möri, Andreas↗

Control rod drive mechanism with heat pipe cooling

A representative cooling system for a nuclear reactor control rod drive mechanism (CRDM) includes an evaporation section located within or next to the CRDM and a condensation section fluidly coupled to the evaporation section. The cooling system includes a set of heat fins coupled to drive coils in the CRDM and heat pipes that extend through the drive coils and heat fins. A fluid evaporates while in the evaporation section of the heat pipes from heat generated by the CRDM and moves out of the evaporation section into the condensation section in the heat fins. The fluid cools and condensates while in the condensation section, recirculating back into the evaporation section. This passive natural circulation cooling system reduces or eliminates the number of water hoses, piping, and other water pumping equipment typically used for cooling a CRDM thereby increasing nuclear reactor reliability and simplifying nuclear reactor operation and maintenance.

Lobscheid, Christian↗

Southern Ocean polynyas and dense water formation in a high-resolution, coupled Earth system model

Antarctic coastal polynyas produce dense shelf water, a primary source of Antarctic Bottom Water that contributes to the global overturning circulation. This paper investigates Antarctic dense water formation in the high-resolution version of the Energy Exascale Earth System Model (E3SM-HR). The model is able to reproduce the main Antarctic coastal polynyas, although the polynyas are smaller in area compared to observations. E3SM-HR also simulates several occurrences of open-ocean polynyas (OOPs) in the Weddell Sea at a higher rate than what the last 50 years of the satellite sea ice observational record suggests, but similarly to other high-resolution Earth system model simulations. Furthermore, the densest water masses in the model are formed within the OOPs rather than on the continental shelf as is typically observed. Biases related to the lack of dense water formation on the continental shelf are associated with overly strong atmospheric polar easterlies, which lead to a strong Antarctic Slope Front and too little exchange between on- and off-continental shelf water masses. Strong polar easterlies also produce excessive southward Ekman transport, causing a build-up of sea ice over the continental shelf and enhanced ice melting in the summer season. This, in turn, produces water masses on the continental shelf that are overly fresh and less dense relative to observations. Our results indicate that high resolution alone is insufficient for models to properly reproduce Antarctic dense water; the large-scale polar atmospheric circulation around Antarctica must also be accurately simulated.

54 ENVIRONMENTAL SCIENCES↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dissipation Scaled Internal Wave Drag in a Global Heterogeneously Coupled Internal/External Mode Total Water Level Model

This study showcases a global, heterogeneously coupled total water level system wherein salinity and temperature outputs from a coarser-resolution (~12 km) ocean general circulation model are used to calculate density-driven terms within a global, higher-resolution (~2.5 km) depth-averaged total water level model. We demonstrate that the inclusion of baroclinic forcing in the barotropic model requires modification of the internal wave drag term to prevent excess degradation of tidal results compared to the barotropic model. By scaling the internal tide dissipation by an easy to calculate dissipation ratio, the resulting heterogeneously coupled model has complex root mean square errors (RMSE) of 2.27 cm in the deep ocean and 12.16 cm in shallow waters for the M 2 tidal constituent. While this represents a 10%–20% deterioration as compared to the barotropic model, the improvements in total water level prediction more than offset this degradation. Global median RMSE compared to observations of total water levels, 30-day sea levels, and non-tidal residuals improve by 1.86 (18.5%), 2.55 (42.5%), and 0.36 (5.3%) cm respectively. The drastic improvement in model performance highlights the importance of including density-driven effects within global hydrodynamic models and will help to improve the results of both hindcasts and forecasts in modeling extreme and nuisance flooding. With only an 11% increase in model run time compared to the fully barotropic total water level model, this approach paves the way for high resolution coastal water level and flood models to be used alongside climate models, improving operational forecasting of total water levels.

Blakely, Coleman Peter [University of Notre Dame, ↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Creative absorber design and optimization for CO 2 capture with aqueous piperazine

The Texas Carbon Management Program is preparing a Front-End Engineering Design (FEED) of the PZASTM (Piperazine with the Advanced Stripper TM ) for CO 2 capture at a natural gas combined cycle power plant in West Texas. This paper develops the absorber design for the capture system and studies the operational strategies of the absorber in response to ambient temperature swing. The design uses 2 absorber trains, and each train integrates absorption and a water-wash section in one column. Each column has a cross-section area of 174 m 2 and consists of 3 sections of MellapakPlus® 252Y structured packing. Packing heights for each section are 3, 4.9, and 2.7 m from top to bottom. A pump-around intercooler applied at the bottom bed circulates solvent and eliminates the direct contact cooler. The baseline CO 2 removal rate is 90% and will vary between 78% and 90% with ambient temperature. The system uses air cooling to eliminate cooling water usage. The water balance in the system will be managed by operating the water wash at a high circulation rate (1300 kg/h) to condense water during the night and make up for water loss during the day. Finally, the proposed design reduces the capital cost of the absorber column by minimizing the packing height and eliminating the direct contact cooler (DCC), and improves the energy cost by lowering the pump-around intercooling temperature and increasing the pump-around rate.

03 NATURAL GAS↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Uncertainty-informed selection of CMIP6 Earth System Model subsets for use in multisectoral and impact models

Earth system models (ESMs) and general circulation models (GCMs) are heavily used to provide inputs to sectoral impact and multisector dynamic models, which include representations of energy, water, land, economics, and their interactions. Therefore, representing the full range of model uncertainty, scenario uncertainty, and interannual variability that ensembles of these models capture is critical to the exploration of the future co-evolution of the integrated human–Earth system. The pre-eminent source of these ensembles has been the Coupled Model Intercomparison Project (CMIP). With more modeling centers participating in each new CMIP phase, the size of the model archive is rapidly increasing, which can be intractable for impact modelers to effectively utilize due to computational constraints and the challenges of analyzing large datasets. In this work, we present a method to select a subset of the latest phase, CMIP6, featuring models for use as inputs to a sectoral impact or multisector dynamics models, while prioritizing preservation of the range of model uncertainty, scenario uncertainty, and interannual variability in the full CMIP6 ensemble results. This method is intended to help impact modelers select climate information from the CMIP archive efficiently for use in downstream models that require global coverage of climate information. This is particularly critical for large-ensemble experiments of multisector dynamic models that may be varying additional features beyond climate inputs in a factorial design, thus putting constraints on the number of climate simulations that can be used. We focus on temperature and precipitation outputs of CMIP6 models, as these are two of the most used variables among impact models, and many other key input variables for impacts are at least correlated with one or both of temperature and precipitation (e.g., relative humidity). Besides preserving the multi-model ensemble variance characteristics, we prioritize selecting CMIP6 models in the subset that preserve the very likely distribution of equilibrium climate sensitivity values as assessed by the latest Intergovernmental Panel on Climate Change (IPCC) report. This approach could be applied to other output variables of climate models and, possibly when combined with emulators, offers a flexible framework for designing more efficient experiments on human-relevant climate impacts. It can also provide greater insight into the properties of existing CMIP6 models.

Snyder, Abigail C.↗

Modulation of Tropical Convection-Circulation Interaction by Aerosol Indirect Effects in Convective Self-Aggregation Simulations of a Gray Zone Global Model

Disentangling the response of tropical convective updrafts to enhanced aerosol concentrations has been challenging. Leading theories for explaining the influence of aerosol concentrations on tropical convection are based on the dynamical response of convection to changes in cloud microphysics, neglecting possible changes in the environment. In recent years, global convection-permitting models (GCPM) have been developed to circumvent problems arising from imposing artificial scale separation on physical processes associated with deep convection. Here, we use a global model in the convective gray zone that partially simulates deep convection to investigate how enhanced concentrations of aerosols that act as cloud condensate nuclei (CCN) impact tropical convection features by modulating the convection-circulation interaction. Results from a pair of idealized non-rotating radiative-convective equilibrium simulations show that the enhanced CCN concentration leads to weaker large-scale circulation, the closeness of deep convective systems to the moist cluster edges, and more mid-level cloud water at an equilibrium state in which convective self-aggregation occurred. Correspondingly, the enhanced CCN concentration modulates how the physical processes that support or oppose convective aggregation maintain the aggregated state at equilibrium. Overall, the enhanced CCN concentration facilitates the development of deep convection in a drier environment but reduces mean precipitation. Our results emphasize the importance of allowing atmospheric phenomena to evolve continuously across spatial and temporal scales in simulations when investigating the response of tropical convection to changes in cloud microphysics.

54 ENVIRONMENTAL SCIENCES↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Linking Synoptic Patterns to Cloud Properties and Local Circulations Over Southeastern Texas

This report classifies meteorological regimes in the southeastern Texas region to identify environmental conditions that favor sea-breeze induced convection. The classification is accomplished using a Self-Organizing Map (SOM) approach. We applied SOM to 10 years of 700-hPa geopotential height anomalies during the summer months from reanalysis data to distinguish three dominant synoptic regimes, with a continuum of transitional states between those. The primary regimes include: (a) a pre-trough regime associated with a synoptic trough, (b) a post-trough regime with upper-level northerly flow, and (c) an anticyclonic regime within the westward extent of the Bermuda High. We project the data from the Geostationary Operational Environmental Satellite and the Next Generation Weather Radar system onto each SOM node to investigate the characteristics of cloud and precipitation properties in different regimes. When southeastern Texas is positioned to the southwest quadrant of a maritime high pressure system, an increased cloud frequency is observed over the region during the afternoon hours due to significant moisture advection. A confluence of synoptic southerly flow and sea-breeze circulation commonly occurs in this regime. When a high pressure system is over southeastern Texas, the area is dominated by large-scale subsidence with weak pressure gradients and moderate precipitable water vapor. This weak synoptic forcing is favorable for the formation of a sea-breeze circulation. This is confirmed by an enhanced onshore flow and a decreased temperature at the surface in the early afternoon, as well as a sharp increase in radar echo top height.

54 ENVIRONMENTAL SCIENCES↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Dynamic coevolution of baseflow and multiscale groundwater flow system during prolonged droughts

Field and numerical studies suggest that baseflow is composed of waters from a spectrum of groundwater flow paths termed the Groundwater Flow System (GWFS) – from shallow hillslope contributions to watershed-scale deep circulation originating in headwaters and discharging into lowland rivers. Here, we explore the evolution of the GWFS under prolonged droughts to understand its dynamics and multiscale nature, and to elucidate its role in baseflow generation and recession at the watershed scale. In this work, we consider three drought scenarios of varying severity and simulate groundwater flow in a 2-D cross-section of an idealized watershed with deep permeable bedrock, tracking the evolution of flow paths, baseflow, and residence times during the recession process. We find that baseflow generation at different drainage stages, and within different subwatersheds, is influenced distinctly by flow paths of different scales, depending on the relative strength of the flow paths and the position of the subwatersheds relative to the recharge/discharge zones of the deeper watershed-scale groundwater circulation. Despite having the same local relief, geology, and climate, baseflow from each subwatershed has a distinct recession behavior and time-dependent residence time distribution. Also, the hydraulic and transport characteristics of baseflow generation co-evolve and are strongly affected by the connection state of the water table to subwatersheds. These findings suggest that asynchrony and dissimilarity of baseflow generation from hillslopes under the impact of the watershed-scale groundwater flow, and interactions with local-scale and intermediate-scale groundwater flow, must be taken into account when interpreting baseflow recession data and building conceptual baseflow models at the watershed scale.

54 ENVIRONMENTAL SCIENCES↗