Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cherenkov”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cherenkov and scintillation separation in water-based liquid scintillator using an LAPPDTM

Abstract This manuscript describes measurements of water-based liquid scintillators (WbLS), demonstrating separation of the Cherenkov and scintillation components using a low energy $$\beta $$ β source and the fast timing response of a Large Area Picosecond Photodetector (LAPPD). Additionally, the time profiles of three WbLS mixtures, defined by the relative fractions of scintillating compound, are characterized, with improved sensitivity to the scintillator rise-time. The measurements were made using both an LAPPD and a conventional photomultiplier tube (PMT). All samples were measured with an effective resolution $$O\left( 100~\text {ps}\right) $$ O 100 ps , which allows for the separation of Cherenkov and scintillation light (henceforth C/S separation) by selecting on the arrival time of the photons alone. The Cherenkov purity of the selected photons is greater than 60% in all cases, with greater than 80% achieved for a sample containing 1% scintillator. This is the first demonstration of the power of synthesizing low light yield scintillators, of which WbLS is the canonical example, with fast photodetectors, of which LAPPDs are an emerging leader, and has direct implication for future mid- and large-scale detectors, such as Theia , ANNIE, and AIT-NEO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

Cherenkov gamma ray detectors are a valuable diagnostic technique for HED systems. Inertial confinement fusion is working towards high gain ignition. Gamma rays from ICF systems can help inform the degradation mechanisms preventing ignition: Carbon ablator is not being degraded, unlike the DT fuel; carbon γ timing can estimate shell energy during bangtime and may suggest hot spot cooling rate; and Cherenkov detectors are also used for high spatial and temporal resolution ICF mix studies on OMEGA. Cherenkov systems also inform energy spectrum of radiographic sources: ARC laser and Mercury pulsed power machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and construction of the Chips water Cherenkov neutrino detector

Chips (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the Chips detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of Cherenkov photon production in PbF 2 crystals using proton beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. Finally, we focus on using PbF 2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov-type three-dimensional breakdown behavior of the Bloch-point domain wall motion in the cylindrical nanowire

A three-dimensional breakdown behavior of the magnetic Bloch-point domain wall (BP-DW) propagation was investigated in a ferromagnetic nanowire with the variation of the external magnetic field by means of micromagnetic simulation. As magnetic field strength increases up to a threshold value, the BP-DW velocity approaches a critical phase velocity of the spontaneously emitting spin wave (SW), where a Cherenkov-type DW breakdown phenomenon is observed originating from an interaction between the spontaneously emitting SW and the BP-DW. It is found that the velocity of the BP-DW approaches a maximum value (~2000 m/s) due to the intrinsic reversal time of a BP spin texture. This suggests that although cylindrical ferromagnetic nanowires might be free from the two-dimensional Walker breakdown phenomenon, there exists a Cherenkov-type three-dimensional breakdown behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning for imaging Cherenkov detectors

Imaging Cherenkov detectors are largely used in modern nuclear and particle physics experiments where cutting-edge solutions are needed to face always more growing computing demands. This is a fertile ground for AI-based approaches and at present we are witnessing the onset of new highly efficient and fast applications. This paper presents novel directions with applications to Cherenkov detectors. In particular, recent advances on detector design and calibration, as well as particle identification are presented.

47 OTHER INSTRUMENTATION↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Prospects for detecting heavy WIMP dark matter with the Cherenkov Telescope Array: The Wino and Higgsino

TeV-scale particles that couple to the standard model through the weak force represent a compelling class of dark matter candidates. The search for such weakly interacting massive particles has already spanned multiple decades, and whilst it has yet to provide any definitive evidence for their existence, viable parameter space remains. In this paper, we show that the upcoming Cherenkov Telescope Array (CTA) has significant sensitivity to uncharted parameter space at the TeV mass scale. To do so, we focus on two prototypical dark matter candidates, the Wino and Higgsino. Additionally, sensitivity forecasts for both models are performed including the irreducible background from misidentified cosmic rays, as well as a range of estimates for the Galactic emissions at TeV energies. For each candidate, we find substantial expected improvements over existing bounds from current imaging atmospheric Cherenkov telescopes. In detail, for the Wino we find a sensitivity improvement of roughly an order of magnitude in <σ v>, whereas for the Higgsino we demonstrate that CTA has the potential to become the first experiment that has sensitivity to the thermal candidate. Taken together, these enhanced sensitivities demonstrate the discovery potential for dark matter at CTA in the 1–100 TeV mass range.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of the Cherenkov Telescope Array to a dark matter signal from the Galactic centre

We provide an updated assessment of the power of the Cherenkov Telescope Array (CTA) to search for thermally produced dark matter at the TeV scale, via the associated gamma-ray signal from pair-annihilating dark matter particles in the region around the Galactic centre. We find that CTA will open a new window of discovery potential, significantly extending the range of robustly testable models given a standard cuspy profile of the dark matter density distribution. Importantly, even for a cored profile, the projected sensitivity of CTA will be sufficient to probe various well-motivated models of thermally produced dark matter at the TeV scale. This is due to CTA's unprecedented sensitivity, angular and energy resolutions, and the planned observational strategy. The survey of the inner Galaxy will cover a much larger region than corresponding previous observational campaigns with imaging atmospheric Cherenkov telescopes. CTA will map with unprecedented precision the large-scale diffuse emission in high-energy gamma rays, constituting a background for dark matter searches for which we adopt state-of-the-art models based on current data. Throughout our analysis, we use up-to-date event reconstruction Monte Carlo tools developed by the CTA consortium, and pay special attention to quantifying the level of instrumental systematic uncertainties, as well as background template systematic errors, required to probe thermally produced dark matter at these energies.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter and galaxy cross-correlations with the Cherenkov Telescope Array Observatory

The Cherenkov Telescope Array Observatory (CTAO) will be a ground-based Cherenkov telescope performing wide-sky surveys, ideal for anisotropy studies such as cross-correlations with tracers of the cosmic large-scale structure. Cross-correlations can shed light on high-energy γ -ray sources and potentially reveal exotic signals from particle dark matter. In this work, we investigate CTAO sensitivity to cross-correlation signals between γ -ray emission and galaxy distributions. We find that by using dense, low-redshift catalogs like 2 MASS, and for integration times around 50 hours, this technique achieves sensitivities to both annihilating and decaying dark matter signals that are competitive with those from dwarf galaxy and cluster analyses.

Pinetti, Elena [CCA, New York; Perimeter Inst. The↗

Color chiral Cherenkov radiation and energy loss in the quark-gluon plasma

We introduce and investigate the color chiral Cherenkov effect which consists in radiation of the circularly polarized gluons by a fast color charge moving with constant velocity in the presence of the chiral magnetic current. We derive the transition rates for all gluon polarizations. We compute the contribution of the color chiral Cherenkov effect to the parton energy loss in the quark-gluon plasma. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-step dependent force interpolation scheme for suppressing numerical Cherenkov instability in relativistic particle-in-cell simulations

The WT scheme, a piecewise polynomial force interpolation scheme with time-step dependency, is proposed in this paper for relativistic particle-in-cell (PIC) simulations. The WT scheme removes the lowest order numerical Cherenkov instability (NCI) growth rate for arbitrary time steps allowed by the Courant condition. While NCI from higher order resonances is still present, the numerical tests show that for smaller time steps, the numerical instability grows much slower than using the optimal time step found in previous studies. The WT scheme is efficient for improving the quality and flexibility of relativistic PIC simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗