Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Camera shutter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In-vessel visible inspection system on KSTAR

To monitor the global formation of the initial plasma and damage to the internal structures of the vacuum vessel, an in-vessel visible inspection system has been installed and operated on the Korean superconducting tokamak advanced research (KSTAR) device. It consists of four inspection illuminators and two visible/H-alpha TV cameras. Each illuminator uses four 150 W metal-halide lamps with separate lamp controllers, and programmable progressive scan charge-coupled device cameras with 1004x1004 resolution at 48 frames/s and a resolution of 640x480 at 210 frames/s are used to capture images. In order to provide vessel inspection capability under any operation condition, the lamps and cameras are fully controlled from the main control room and protected by shutters from deposits during plasma operation. In this paper, we describe the design and operation results of the visible inspection system with the images of the KSTAR Ohmic discharges during the first plasma campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature measurement using very high shutter speed to avoid image saturation

This paper explores the adaptation of the two-colour principle to develop a high-speed colour temperature correlation system, which is able to cover a range of temperature that is challenging to achieve before. A colour digital camera has built in RGB filters. It is possible to measure the temperature from the ratio of intensity of the green and red pixels using the two-colour principle based on the expansion of the Plank’s radiation law. In this study, experiments were carried out using a temperature calibrated tungsten ribbon lamp which can be tuned to vary from 1300 to 2200°C. Using very high shutter speed and small aperture, the high-speed camera successfully captured the tungsten ribbon without image saturation at the full temperature scale. Tests have been carried out at different temperature and camera settings. The sensitivity and errors have been analysed, and experiment results demonstrate the potential of using very high shutter speed is available for measuring the temperature even beyond 2200°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

Initial Results of Transverse Beam Profile Measurements Using a LYSO:Ce Crystal

A prototype transverse beam profile monitor for eventual use at the Advanced Superconducting Test Accelerator (ASTA) has been tested at the Fermilab A0 Photoinjector. Results from low-charge (20 pC) studies indicate that a LYSO:Ce scintillator will be a viable alternative to a YAG:Ce scintillator when using intercepting radiation convertor screens for beam profiling. We will also describe the planned implementation of LYSO:Ce crystals to mitigate the coherent optical transition radiation due to the microbunching instability through the use of band-pass filters and specially timed cameras. Based upon tests conducted at the A0PI, we can conclude that the LYSO:Ce crystal will be a suitable alternative to the YAG:Ce crystal for beam imaging. The YAG:Ce and LYSO:Ce crystals both offer similar performance characteristics for low charge beam, but LYSO:Ce combined with a violet bandpass filter has the added benefit of mitigating the COTR due to themicrobunching instability in beam images. The OTR screen can also be used to avoid the scintillator saturation at high areal charge density and the thin foils generate less beam scattering. If the use of bandpass filters, CCD shutter timing and LYSO:Ce are not enough to reduce the COTR due to the microbunching instability, we could use a gated, intensified camera.

43 PARTICLE ACCELERATORS↗

Control and automation of the Pegasus multi-point Thomson scattering system

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ePix: a class of architectures for second generation LCLS cameras

ePix is a novel class of ASIC architectures, based on a common platform, optimized to build modular scalable detectors for LCLS. The platform architecture is composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog-to-digital converters per column. It also implements a dedicated control interface and all the required support electronics to perform configuration, calibration and readout of the matrix. Based on this platform a class of front-end ASICs and several camera modules, meeting different requirements, can be developed by designing specific pixel architectures. This approach reduces development time and expands the possibility of integration of detector modules with different size, shape or functionality in the same camera. The ePix platform is currently under development together with the first two integrating pixel architectures: ePix100 dedicated to ultra low noise applications and ePix10k for high dynamic range applications.

Dragone, A.↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Mechanical Design of the LSST Camera

The LSST camera is a tightly packaged, hermetically-sealed system that is cantilevered into the main beam of the LSST telescope. It is comprised of three refractive lenses, on-board storage for five large filters, a high-precision shutter, and a cryostat that houses the 3.2 giga-pixel CCD focal plane along with its support electronics. The physically large optics and focal plane demand large structural elements to support them, but the overall size of the camera and its components must be minimized to reduce impact on the image stability. Also, focal plane and optics motions must be minimized to reduce systematic errors in image reconstruction. Design and analysis for the camera body and cryostat will be detailed.

47 OTHER INSTRUMENTATION↗

Fast x-ray microdiffraction techniques for studying irreversible transformations in materials.

A pair of techniques have been developed for performing time-resolved X-ray microdiffraction on irreversible phase transformations. In one technique capillary optics are used to focus a high-flux broad-spectrum X-ray beam to a 60 {micro}m spot size and a fast pixel array detector is used to achieve temporal resolution of 55 {micro}s. In the second technique the X-rays are focused with Kirkpatrick-Baez mirrors to achieve a spatial resolution better than 10 {micro}m and a fast shutter is used to provide temporal resolution better than 20 {micro}s while recording the diffraction pattern on a (relatively slow) X-ray CCD camera. Example data from experiments are presented where these techniques are used to study self-propagating high-temperature synthesis reactions in metal laminate foils.

43 PARTICLE ACCELERATORS↗

Design and development of the 3.2 gigapixel camera for the Large Synoptic Survey Telescope

The Large Synoptic Survey Telescope (LSST) is a large aperture, wide-field facility designed to reflect deep images of half the sky every few nights. There is only a single instrument on the telescope, a 9.6 square degree visible-band camera, which is mounted close to the secondary mirror, and points down toward the tertiary. The requirements of the LSST camera present signifcant technical design challenges. To cover the entire 0.35 to 1 μm visible band, the camera incorporates an array of 189 over-depleted bulk silicon CCDs with 10 μm pixels. The CCDs are assembled into 3 x 3 "rafts", which are then mounted to a silicon carbide grid to achieve a total focal plane flatness of 15 μm p-v. The CCDs have 16 amplifiers per chip, enabling the entire 3.2 Gigapixel image to be read out in 2 seconds. Unlike other astronomical cameras, a vast majority of the focal plane electronics are housed in the cryostat, which uses a mixed refrigerant Joule-Thompson system to maintain a -100ºC sensor temperature. The shutter mechanism uses a 3 blade stack design and a hall-effect sensor to achieve high resolution and uniformity. There are 5 filters stored in a carousel around the cryostat and the auto changer requires a dual guide system to control its position due to severe space constraints. This paper presents an overview of the current state of the camera design and development plan.

99 GENERAL AND MISCELLANEOUS↗

Development of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited)

A new endoscope with optimised divertor view has been developed in order to survey and monitor the emission of specific impurities such as tungsten and the remaining carbon as well as beryllium in the tungsten divertor of JET after the implementation of the ITER-like wall in 2011. The endoscope is a prototype for testing an ITER relevant design concept based on reflective optics only. It may be subject to high neutron fluxes as expected in ITER. The operating wavelength range, from 390 nm to 2500 nm, allows the measurements of the emission of all expected impurities (W I, Be II, C I, C II, C III) with high optical transmittance ({>=}30% in the designed wavelength range) as well as high spatial resolution that is {<=}2 mm at the object plane and {<=}3 mm for the full depth of field ({+-}0.7 m). The new optical design includes options for in situ calibration of the endoscope transmittance during the experimental campaign, which allows the continuous tracing of possible transmittance degradation with time due to impurity deposition and erosion by fast neutral particles. In parallel to the new optical design, a new type of possibly ITER relevant shutter system based on pneumatic techniques has been developed and integrated into the endoscope head. The endoscope is equipped with four digital CCD cameras, each combined with two filter wheels for narrow band interference and neutral density filters. Additionally, two protection cameras in the {lambda} > 0.95 {mu}m range have been integrated in the optical design for the real time wall protection during the plasma operation of JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurements of D{sub α} spectrum produced by anisotropic fast ions in the gas dynamic trap

Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed two-camera imaging pyrometer for mapping fireball temperatures

A high-speed imaging pyrometer was developed to investigate the behavior of flames and explosive events. The instrument consists of two monochrome high-speed Phantom v7.3 m cameras made by Vision Research Inc. arranged so that one lens assembly collects light for both cameras. The cameras are filtered at 700 or 900 nm with a 10 nm bandpass. The high irradiance produced by blackbody emission combined with variable shutter time and f-stop produces properly exposed images. The wavelengths were chosen with the expected temperatures in mind, and also to avoid any molecular or atomic gas phase emission. Here, the temperatures measured using this pyrometer of exploded TNT charges are presented.

42 ENGINEERING↗

WE-DE-BRA-10: Development of a Novel Scanning Beam Low-Energy Intraoperative Radiation Therapy (SBIORT) System for Pancreatic Cancer

Purpose: Developing a compact collimator system and validating a 3D surface imaging module for a scanning beam low-energy x-ray radiation therapy (SBIORT) system that enables delivery of non-uniform radiation dose to targets with irregular shapes intraoperatively. Methods: SBIORT consists of a low energy x-ray source, a custom compact collimator module, a robotic arm, and a 3D surface imaging module. The 3D surface imaging system (structure sensor) is utilized for treatment planning and motion monitoring of the surgical cavity. SBIORT can deliver non-uniform dose distributions by dynamically moving the x-ray source assembly along optimal paths with various collimator apertures. The compact collimator utilizes a dynamic shutter mechanism to form a variable square aperture. The accuracy and reproducibility of the collimator were evaluated using a high accuracy encoder and a high resolution camera platform. The dosimetrical characteristics of the collimator prototype were evaluated using EBT3 films with a Pantak Therapax unit. The accuracy and clinical feasibility of the 3D imaging system were evaluated using a phantom and a cadaver cavity. Results: The SBIORT collimator has a compact size: 66 mm diameter and 10 mm thickness with the maximum aperture of 20 mm. The mechanical experiment indicated the average accuracy of leaf position was 0.08 mm with a reproducibility of 0.25 mm at 95% confidence level. The dosimetry study indicated the collimator had a penumbra of 0.35 mm with a leaf transmission of 0.5%. 3D surface scans can be acquired in 5 seconds. The average difference between the acquired 3D surface and the ground truth is 1 mm with a standard deviation of 0.6 mm. Conclusion: This work demonstrates the feasibility of the compact collimator and 3D scanning system for the SBIORT. SBIORT is a way of delivering IORT with a compact system that requires minimum shielding of the procedure room. This research is supported by the University of Iowa Internal Funding Initiatives.

60 APPLIED LIFE SCIENCES↗

A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment (invited)

Here, a novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fast shutter. This –10 3 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot T e (R) for n e > 5 × 10 18 m –3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

The Steady State Challenge for Soft X-Ray Diagnostics on Wendelstein 7-X Stellarator

The steady state operation of Wendelstein 7-X stellarator presently under construction in Greifswald poses special challenges to the diagnostics development [1, 2]. A critical issue is the heat load on plasma facing components ({approx}500 kW/m{sup 2}) over a long discharge time (up to 30 min), which leads to the necessity of active cooling. As result, the design of the 400 channel soft X-Ray Multi Camera Tomography System (XMCTS) [2, 3] has to cope with dark currents and amplifier drifts due to the heating of active components like photo diodes and in-vessel preamplifiers. In order to allow for a quantitative measurement of dynamic drifts and offsets, a shutter system and blind diodes are considered to compensate these effects. Another important issue is the large amount of data gathered by the XMCT system during long pulse discharges. A fast but less precise online reconstruction is planned, which will give information on the plasma shape and position on a human time scale. The two options under investigation are a Cormack-Inversion method and an approach based on neural networks [4]. Dependent on the available hardware, as much information as possible should be stored for more accurate offline-analysis. An intelligent way of marking interesting data is required. In case that the steady-state storage of all measured data is not feasible, at least this marked data will be stored in high time resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging high jitter, very fast phenomena: A remedy for shutter lag

Dielectric breakdown is an example of a natural phenomenon that occurs on very short time scales, making it incredibly difficult to capture optical images of the process. Event initiation jitter is one of the primary challenges, as even a microsecond of jitter time can cause the imaging attempt to fail. Initial attempts to capture images of dielectric breakdown using a gigahertz frame rate camera and an exploding bridge wire initiation were stymied by high initiation jitter. Subsequently, a novel optical delay line apparatus was developed in order to effectively circumvent the jitter and reliably image dielectric breakdown. Here, the design and performance of the optical delay line apparatus are presented. The optical delay line increased the image capture success rate from 25% to 94% while also permitting enhanced temporal resolution and has application in imaging other high-jitter, extremely fast phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗