Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CaNiN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Velocity and attenuation of sound in arterial tissues

The velocity of sound in excised human and canine arterial tissues is measured in order to serve as a basis for the development and application of ultrasonic techniques for the diagnosis of atherosclerotic lesions. Measurements of sound velocity at different regions of 11 human and six canine aortas were made by a time delay spectrometer technique at frequencies from 2 to 10 MHz, and compared with ultrasonic attenuation parameters and the results of biochemical assays. Sound velocity is found to increase with increasing attenuation at all frequencies, and with increasing collagen content. A strong dependence of sound velocity on cholesterol content or low calcium contents is not observed, although velocities of up to 2000 m/sec are observed in highly organized calcified lesions. A decrease in velocity with decreasing temperature is also noted. It is thus concluded that it is principally the differences in tissue collagen levels that contribute to image formation according to sound velocity.

Rooney, J. A.↗

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.↗

The earliest fossil evidence for sexual dimorphism in primates

Recently obtained material of the early Eocene primate Notharctus venticolus, including two partial skulls from a single stratigraphic horizon, provides the geologically earliest evidence of sexual dimorphism in canine size and shape in primates and the only unequivocal evidence for such dimorphism in strepsirhines. By analogy with living platyrrhines, these data suggest that Notharctus venticolus may have lived in polygynous social groups characterized by a relatively high level of intermale competition for mates and other limited resources. The anatomy of the upper incisors and related evidence imply that Notharctus is not as closely related to extant lemuriform primates as has been recently proposed. The early Eocene evidence for canine sexual dimorphism reported here, and its occurrence in a nonanthropoid, indicates that in the order Primates such a condition is either primitive or evolved independently more than once.

Krishtalka, Leonard↗

Subtle alternating electrocardiographic morphology as an indicator of decreased cardiac electrical stability

Observations from finite-element computer models, together with analytic developments based on percolation theory have suggested that subtle fluctuations of ECG morphology might serve as an indicator diminished cardiac electrical stability. With fixed-rate atrial pacing in canines, we have previously observed a pattern of alternation in T wave energy which correlated with cardiac electrical stability. We report here on a series of 20 canine experiments in which cardiac electrical stability (measured via Ventricular Fibrillation Threshold determination) was compared to a non-degenerate, multidimensional measurement of the degree of alternating activity present in the ECG complex morphology. The decrease in cardiac electrical stability brought on by both coronary artery occlusion and systemic hypothermia was consistently accompanied by subtle alternation in ECG morphology, with the absolute degree of alternating activity being significantly (negatively) correlated with cardiac electrical stability.

Ventricular Fibrillation↗

Preliminary crystallographic studies of four crystal forms of serum albumin

Several crystal forms of serum albumin suitable for three-dimensional structure determination have been grown. These forms include crystals of recombinant and wild-type human serum albumin, baboon serum albumin, and canine serum albumin. The intrinsic limits of X-ray diffraction for these crystals are in the range 0.28-0.22 nm. Two of the crystal forms produced from human and canine albumin include incorporated long-chain fatty acids. Molecular replacement experiments have been successfully conducted on each crystal form using the previously determined atomic coordinates of human serum albumin illustrating the conserved tertiary structure.

Serum Albumin/chemistry↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Coronary flow and left ventricular function during environmental stress.

A canine model was used to study the effects of different environmental stresses on the heart and coronary circulation. The heart was surgically instrumented to measure coronary blood flow, left ventricular pressure, and other cardiovascular variables. Coronary flow was recorded by telemetry. Physiologic data were processed and analyzed by analog and digital computers. By these methods the physiologic response to altitude hypoxia, carbon monoxide, hypercapnia, acceleration, exercise, and the interaction of altitude hypoxia and carbon monoxide were described. The effects of some of these stresses on the heart and coronary circulation are discussed.

Erickson, H. H.↗

Effect of varying differentiator frequency response on recorded peak dP/dt

Dogs were used to study the effects of varying the differentiator cutoff frequency on the recorded peak first derivative of left ventricular pressure with respect to time (dP/dt), using high-precision solid-state pressure transducers and recording equipment. In canine hearts with a basic periodicity of 1 to 3 Hz, the differentiator frequency response required to record an accurate peak dP/dt is found to be influenced by the value of peak dP/dt. At peak dP/dt ranging from 1500 to 9000 mm Hg/sec (200 and 1200 kPa/sec), a differentiator cutoff frequency of at least 90 Hz was required to record accurately peak dP/dt.

Barry, W. H.↗

Cardiovascular function during sustained +G/z/ stress

The development of aerospace systems capable of very high levels of positive vertical accelerators stress has created a need for a better understanding of the cardiovascular responses to acceleration. Using a canine model, the heart and cardiovascular system were instrumented to continuously measure coronary blood flow, cardiac output, left ventricular and aortic root pressure, and oxygen saturation in the aorta, coronary sinus, and right ventricle. The animals were exposed to acceleration profiles up to +6 G, 120 s at peak G; a seatback angle of 45 deg was simulated in some experiments. Radiopaque contrast medium was injected to visualize the left ventricular chamber, coronary vasculature, aorta, and branches of the aorta. The results suggest mechanisms responsible for arrhythmias which may occur, and subendocardial hemorrhage which has been reported in other animals.

Erickson, H. H.↗

An Elastic Analysis of a Plated Bone to Determine Fracture Gap Motion

An elastic analysis to determine fracture gap motions occurring in the osteotomized and plated canine femur was performed using the finite element program NASTRAN. The femur was idealized as a hollow right cylinder, and transverse anisotropy was assumed for the elastic properties of the bone. A 3-D 360 degree model consisting of 224 isoparametric quadrilateral hexahedral and 11 beam elements was created. A range of plate stiffnesses was tested by varying the modulus of elasticity of the plate from 207 GPa to 1 GPA. Moments were applied in the plane of the plate, about the axis of the plate, and in the plane of the screws. Results showed that, for plates of typical geometry and elastic modulus under 10 GPa, the contribution to fracture gap motion occurring due to deformation in the bone was negligible compared to that contribution from deformation in the plate.

Cooke, F. W.↗

A critical synopsis: Continuous growth of proximal tubular kidney epithelial cells in hormone-supplemented serum-free medium

The kidney forms urine and reabsorbs electrolytes and water. Kidney cell lines and hormone supplemented serum free medium were used for growth. The hormones were insulin, transferrin, vasopressin, cholesterol, prostaglandins, hydrocortisone, and triidothyronine. Epithelial cell lines are polar and form hemicysts. The Madin-Darby canine kidney(MDCK) cell line used is distal tubulelike. LLC-PK sub 1 cells are derived from pig kidneys and have the properties of different kidney segments. The LLC-PK sub 1 cells with proximal tubule properties were maintained in hormone-supplemented serum free medium. Seven factors (the aforementioned homrones and selenium) were needed for growth. Hormone-defined medium supported LLC-PK sub 1 cell growth, allowed transport (as seen by hemicyst formation), and influenced cell morphology. Vasopressin (used for growth and morphology) could be partially replaced by isobutylmethylxanthine or dibutyryl cAMP. The defined medium was used to isolate rabbit proximal tubule kidney epithelial cells free of fibroblasts.

Chuman, L. M.↗

Estimation of left ventricular mass in conscious dogs

A method for the assessment of the development or the regression of left ventricular hypertrophy (LVH) in a conscious instrumented animal is described. First, the single-slice short-axis area-length method for estimating the left-ventricular mass (LVM) and volume (LVV) was validated in 24 formaldehyde-fixed canine hearts, and a regression equation was developed that could be used in the intact animal to correct the sonomicrometrically estimated LVM. The LVM-assessment method, which uses the combined techniques of echocardiography and sonomicrometry (in conjunction with the regression equation), was shown to provide reliable and reproducible day-to-day estimates of LVM and LVV, and to be sensitive enough to detect serial changes during the development of LVH.

Coleman, Bernell↗

Continuous flow electrophoretic separation of proteins and cells from mammalian tissues

This paper describes an apparatus for continuous flow electrophoresis (CFE), designed to separate macromolecules and cells at conditions of microgravity. In this CFE, buffer flows upward in a 120-cm long flow chamber, which is 16-cm wide x 3.0-mm thick in the microgravity version (and 6-cm wide x 1.5-mm thick in the unit-gravity laboratory version). Ovalbumin and rat serum albumin were separated in space (flight STS-4) with the same resolution of the two proteins achieved at 25 percent total w/v concentration that was obtained in the laboratory at 0.2 percent w/v concentration. Rat anterior pituitary cells, cultured human embryonic kidney cells, and canine Langerhans cells were separated into subpopulations (flight STS-8) more effectively than in unit gravity, with comparable resolution having been achieved at 100 times the concentration possible on earth.

Hymer, W. C.↗

Fuzzy neural network methodology applied to medical diagnosis

This paper presents a technique for building expert systems that combines the fuzzy-set approach with artificial neural network structures. This technique can effectively deal with two types of medical knowledge: a nonfuzzy one and a fuzzy one which usually contributes to the process of medical diagnosis. Nonfuzzy numerical data is obtained from medical tests. Fuzzy linguistic rules describing the diagnosis process are provided by a human expert. The proposed method has been successfully applied in veterinary medicine as a support system in the diagnosis of canine liver diseases.

Gorzalczany, Marian B.↗