Effect of non-uniform emitter current distribution on power transistor stability
Nonuniform emitter current distribution effect on power transistor thermal stability, discussing temperature distribution effects
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nonuniform emitter current distribution effect on power transistor thermal stability, discussing temperature distribution effects
A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O{sup 3+} ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.
This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.
Integral equation describing current distribution in array of superconducting thin films
Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.
Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.
MGD generator and accelerator electrode drops and current distribution using hydrogen-helium test gas mixture
This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distribution were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [I]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Car10 code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. The nuclear elastic component (also calculated using the MCNPX) has a negligible effect on the shape of the damage distribution. The Coulombic contribution was calculated using MRED [3,4], a Geant4 [4,5] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.
Current distribution along resistivity loaded V-antenna
Current distribution and input admittance of infinitely long cylindrical antenna driven by slice generator and immersed in anisotropic plasma
Current distribution and input impedance of infinite cylindrical antenna in anisotropic plasma, treating it as boundary value problem
This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distributions were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [1]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Carlo code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. While the nuclear elastic component (also calculated using the MCNPX) contributes only a small fraction of the total nonionizing damage energy, its inclusion in the shape of the damage across the array is significant. The Coulombic contribution was calculated using MRED [3-5], a Geant4 [4,6] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.
A computational model of the Mark-IV electrorefiner is currently being developed as a joint project between Idaho National Laboratory, Korea Atomic Energy Research Institute, Seoul National University, and the University of Idaho. As part of this model, the two-dimensional potential and current distributions within the molten salt electrolyte are calculated for U3+ , Zr4+ , and Pu3+ along with the total distributions, using the partial differential equation solver of the commercial Matlab software. The electrical conductivity of the electrolyte solution is shown to depend primarily on the composition of the electrolyte and to average 205 mho/m with a standard deviation of 2.5 × 10-5% throughout the electrorefining process. These distributions show that the highest potential gradients (thus, the highest current) exist directly between the two anodes and cathode. The total, uranium, and plutonium potential gradients are shown to increase throughout the process, with a slight decrease in that of zirconium. The distributions also show small potential gradients and very little current flow in the region far from the operating electrodes.
Fredholm equation description of current distribution in thin-film superconducting strip transmission line
We propose a novel method for tailoring the current distribution of relativistic electron bunches. The technique relies on a recently proposed transverse-to-longitudinal phase space exchange. The bunch is transversely shaped and the phase space exchange mechanism converts this transverse profile into a current profile. The technique provides a tool for generating arbitrary current profiles in a tunable fashion.We demonstrate, via computer simulations, the method and its application to tailor specific current profiles such as, e.g., linearly ramped profiles and train of femtosecond micro-bunches that have application in plasma and dielectric wakefield accelerators.
We proposed a novel method for tailoring the current distribution of relativistic electron bunches. The technique relies on a recently proposed transverse-to-longitudinal phase space exchange. The bunch is transversely shaped and the phase space exchange mechanism converts this transverse profile into a current profile. The technique provides a tool for generating arbitrary current profiles in a tunable fashion. We demonstrate, via computer simulations, the method and its application to tailor specific current profiles such as, e.g., linearly ramped profiles and train of femtosecond micro-bunches that have application in plasma and dielectric wakefield accelerators.
Conducting wall MHD generator channel current distribution, examining computer program for anode and cathode currents
Perfluorocarbons are important contributors to aluminum production greenhouse gas inventories. Tetrafluoromethane and hexafluoroethane are produced in the electrolysis process when a harmful event called anode effect occurs in the cell. This incident is strongly related to the lack of alumina and the current distribution in the cell and can be classified into two categories: high-voltage and low-voltage anode effects. The latter is hard to detect during the normal electrolysis process and, therefore, new tools are necessary to predict this event and minimize its occurrence. This paper discusses a new approach to model the alumina distribution behavior in an electrolysis cell by dividing the electrolytic bath into non-homogenous concentration zones using discrete elements. The different mechanisms related to the alumina distribution are discussed in detail. Moreover, with a detailed electrical model, it is possible to calculate the current distribution among the different anodic assemblies. With this information, the model can evaluate if low-voltage emissions are likely to be present under the simulated conditions. Using the simulator will help the understanding of the role of the alumina distribution which, in turn, will improve the cell energy consumption and stability while reducing the occurrence of high- and low-voltage anode effects.