Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CTC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of propylene-, meta-, and para-linked triazine and tert-butyltriphenylamine as bipolar hosts for phosphorescent organic light-emitting diodes

Three representative bipolar hybrids - tBu-TPA-p-TRZ, tBu-TPA-m-TRZ, and tBu-TPA-L -TRZ with triplet energies, ET = 2.5, 2.7 and 3.0 eV, respectively - were synthesized and characterized for a comprehensive evaluation of their potential as a host for phosphorescent organic light-emitting diodes (PhOLEDs) using red-emitting Ir(piq)3 as the dopant with an ET value of 2.1 eV. Formation of charge transfer complexes, CTCs, was diagnosed by fluorescence bathochromism in increasingly polar solvents. Both intra- and inter-molecular charge transfer processes are invoked to explain CTC formation in all three hybrids. The p-hybrid is by far the most susceptible to CTC formation both in solution and neat solid film, resulting in PhOLEDs with reduced external quantum efficiency, EQE, despite the best balance between charge fluxes across the emitting layer, EML, as revealed by the electron- and hole-only devices in addition to PhOLEDs containing a sensing layer. The highest EQE is achieved with the m-hybrid thanks to the compromise between balanced charge fluxes and CTC formation. The L-hybrid is the least prone to CTC formation while suffering charge flux imbalance to yield an EQE intermediate between those of the m- and p-hybrids. The least CTC formation involving the L-hybrid is advantageous in accommodating the most singlets and triplets readily transferrable to both red and blue phosphors on account of its relatively high ET value. Furthermore, the L-hybrid offers the best morphological stability of the desired glassy EML, thus holding promise for the fabrication of superior PhOLEDs overall.

36 MATERIALS SCIENCE↗

Crosstalk Compensation for a Rapid, Higher Resolution Impedance Spectrum Measurement

Batteries and other energy storage devices are playing larger roles in various industries (e.g., military, automotive, electric utilities, etc.) as the U.S. seeks to reduce its dependence on foreign energy resources. As such, there exists a significant need for accurate, robust state-of-health assessment techniques. Present techniques tend to focus on simple, passive monitoring of voltage and current at a given ambient temperature. However, this approach has the disadvantage of ignoring key elements of health, that is, changes in resistance growth and power fade. Impedance spectroscopy is considered a useful laboratory tool in gauging changes in the resistance and power performance, but it has not been widely considered as an onboard diagnostic tool due to the length of time required to complete the measurement. Cross-Talk Compensation (CTC) is a novel approach that enables rapid, high resolution impedance spectra measurements using a hardware platform that could be designed as an embedded system. This input signal consists of a sum-of-sines excitation current that has a known frequency spread and a duration of one period of the lowest frequency. The voltage response is then captured at a sufficiently fast sample rate. Previously developed rapid impedance spectrum measurement techniques either required a longer excitation signal or a sum-of-sines signal that was separated by harmonic frequencies to reduce or eliminate, respectively, the cross-talk interference in the calculated results. The distinct advantage of CTC, however, is that non-harmonic frequencies can now be included within the excitation signal while still keeping the signal duration at one period of the lowest frequency. Since the frequency spread of the input signal is known, the crosstalk interference between sinusoidal signals within the sum-of-sines at a given frequency of interest can be pre-determined and assigned to an error matrix. Consequently, the real and imaginary components of the impedance at each frequency of interest can be calculated using simple linear algebra based on the error matrix and measured response from the energy storage device given the excitation signal. Analytical validation of CTC over a frequency range between 2000 and 0.1 Hz (i.e., a ten-second input signal duration) was performed using a standardized battery lumped parameter model. The results indicated that the CTC was able to successfully resolve more than 45 frequencies within a sum-of-sines excitation signal, whereas previous techniques could only resolve up to 15 frequencies. A simplified derivation of the CTC technique and its corresponding analytical validation studies using the lumped-parameter model will be presented.

25 ENERGY STORAGE↗

Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The yield and patient factors associated with CT colonography C-RADS results in a non-screening patient population

Objectives: To determine the proportion of diagnostic computed tomography colonography (CTC) Reporting and Data System (C-RADS) categories in a non-screening population, and which patient factors are associated with a positive CTC (C2–4), a non-diagnostic CTC (C0), and potentially relevant extracolonic findings (ECF, E3–4). Methods: Diagnostic CTCs performed at a single academic center from 2017 to 2018 were retrospectively reviewed. For each examination, the indications, age, sex, admission status, and C-RADS categories were recorded. Multivariate logistic regression was performed of patient demographic factors and clinical indications, with adjusted odds ratios (OR) and 95% confidence intervals. Results: 1373 CTCs were included. The mean age was 66.4 ± 13 years (range 24–97). There were 782 women and 75 inpatients. The number of CTCs reported as C0–C4 were 194/1373 (14.1%), 970/1373 (70.6%), 77/1373 (5.6%), 86/1373 (6.3%), and 46/1373 (3.4%), respectively, and 134/1373 (9.8%), 960/1373 (69.9%), 173/1373 (12.6%), and 106/1373 (7.7%) CTCs were reported as E1–4, respectively. Factors that demonstrated the strongest associations were as follows: with C2–4, age groups 50–79 (OR 2.8, 95% confidence interval 1.4–6.1), 80–89 (6.2, 2.9–14.5) and ≥ 90 (7.6, 2.0–29.1), and inpatients (3.4, 1.8–6.4); with C0, age groups 50–79 (5.9, 2.2–24.4), 80–89 (9.8, 3.4–41.8), and ≥ 90 (22.5, 5.8–113.0), incomplete colonoscopy (3.2, 2.0–5.1) and melena or gastrointestinal bleeding (4.1, 1.8–9.4); and with E3–4, age groups 50–79 (1.6, 1.0–2.9), 80–89 (2.0, 1.1–3.9), and ≥ 90 (3.2, 1.2–8.8), and inpatients (2.3, 1.3–3.9). Conclusion: Older age is increasingly associated with a positive test, a non-diagnostic test and potentially relevant ECF. Inpatients are also associated with positive tests and E3–4 findings. Symptoms are not strongly associated with a positive CTC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anorectal pitfalls in computed tomography colonography

There is a wide array of pathological lesions seen in the anorectal region with CT colonography (CTC), much of which is unique to this location. Many relatively common findings in the anorectal region are typically benign, but can be misinterpreted as malignant. There are also technique-related pitfalls that can impede accurate diagnosis of anorectal findings at CTC. Understanding common and uncommon lesions in the anorectal region as well as recognizing technical pitfalls will optimize interpretation of CTC and decrease the number of missed cancers and false positives. This review will systematically cover that they key pitfalls confronting the radiologist at CTC interpretation of the anorectal region, primarily dividing them into those related to underlying anatomy and those related to technique. Tips for how to effectively handle these potential pitfalls will also be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Interrater Reliability in Grading of Rectal Bleeding Using National Cancer Institute Common Toxicity Criteria and Radiation Therapy Oncology Group Toxicity Scales: A Survey of Radiation Oncologists

Purpose: To measure concordance among genitourinary radiation oncologists in using the National Cancer Institute Common Toxicity Criteria (NCI CTC) and Radiation Therapy Oncology Group (RTOG) grading scales to grade rectal bleeding. Methods and Materials: From June 2013 to January 2014, a Web-based survey was sent to 250 American and Canadian academic radiation oncologists who treat prostate cancer. Participants were provided 4 case vignettes in which patients received radiation therapy and developed rectal bleeding and were asked for management plans and to rate the bleeding according to NCI CTC v.4 and RTOG late toxicity grading (scales provided). In 2 cases, participants were also asked whether they would send the patient for colonoscopy. A multilevel, random intercept modeling approach was used to assess sources of variation (case, respondent) in toxicity grading to calculate the intraclass correlation coefficient (ICC). Agreement on a dichotomous grading scale (low grades 1-2 vs high grades 3-4) was also assessed, using the κ statistic for multiple respondents. Results: Seventy-two radiation oncologists (28%) completed the survey. Forty-seven (65%) reported having either written or been principal investigator on a study using these scales. Agreement between respondents was moderate (ICC 0.52, 95% confidence interval [CI] 0.47-0.58) when using NCI CTC and fair using the RTOG scale (ICC 0.28, 95% CI 0.20-0.40). Respondents who chose an invasive management were more likely to select a higher toxicity grade (P<.0001). Using the dichotomous scale, we observed moderate agreement (κ = 0.42, 95% CI 0.40-0.44) with the NCI CTC scale, but only slight agreement with the RTOG scale (κ = 0.19, 95% CI 0.17-0.21). Conclusion: Low interrater reliability was observed among radiation oncologists grading rectal bleeding using 2 common scales. Clearer definitions of late rectal bleeding toxicity should be constructed to reduce this variability and avoid ambiguity in both reporting and interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Influence of Hemorheological Parameters on Circulating Tumor Cell Trajectory and Simulation Time

Extravasation of circulating tumor cells (CTCs) occurs primarily in the microvasculature, where flow and cell interactions significantly affect the blood rheology. Capturing cell trajectory at this scale requires the coupling of several interaction models, leading to increased computational cost that scales as more cells are added or the domain size is increased. In this work, we focus on micro-scale vessels and study the influence of certain hemorheological factors, including the presence of red blood cell aggregation, hematocrit level, microvessel size, and shear rate, on the trajectory of a circulating tumor cell. We determine which of the aforementioned factors significantly affect CTC motion and identify those which can potentially be disregarded, thus reducing simulation time. We measure the effect of these elements by studying the radial CTC movement and runtime at various combinations of these hemorheological parameters. To accurately capture blood flow dynamics and single cell movement, we perform high-fidelity hemodynamic simulations at a sub-micron resolution using our in-house fluid dynamics solver, HARVEY. We find that increasing hematocrit increases the likelihood of tumor cell margination, which is exacerbated by the presence of red blood cell aggregation. As microvessel diameter increases, there is no major CTC movement towards the wall; however, including aggregation causes the CTC to marginate quicker as the vessel size increases. Finally, as the shear rate is increased, the presence of aggregation has a diminished effect on tumor cell margination.

Roychowdhury, Sayan↗

Prostate extracellular vesicles in patient plasma as a liquid biopsy platform for prostate cancer using nanoscale flow cytometry

Background: Extracellular vesicles released by prostate cancer present in seminal fluid, urine, and blood may represent a non-invasive means to identify and prioritize patients with intermediate risk and high risk of prostate cancer. We hypothesize that enumeration of circulating prostate microparticles (PMPs), a type of extracellular vesicle (EV), can identify patients with Gleason Score≥4+4 prostate cancer (PCa) in a manner independent of PSA. Patients and Methods: Plasmas from healthy volunteers, benign prostatic hyperplasia patients, and PCa patients with various Gleason score patterns were analyzed for PMPs. We used nanoscale flow cytometry to enumerate PMPs which were defined as submicron events (100-1000nm) immunoreactive to anti-PSMA mAb when compared to isotype control labeled samples. Levels of PMPs (counts/µL of plasma) were also compared to CellSearch CTC Subclasses in various PCa metastatic disease subtypes (treatment naïve, castration resistant prostate cancer) and in serially collected plasma sets from patients undergoing radical prostatectomy. Results: PMP levels in plasma as enumerated by nanoscale flow cytometry are effective in distinguishing PCa patients with Gleason Score≥8 disease, a highrisk prognostic factor, from patients with Gleason Score≤7 PCa, which carries an intermediate risk of PCa recurrence. PMP levels were independent of PSA and significantly decreased after surgical resection of the prostate, demonstrating its prognostic potential for clinical follow-up. CTC subclasses did not decrease after prostatectomy and were not effective in distinguishing localized PCa patients from metastatic PCa patients. Conclusions: PMP enumeration was able to identify patients with Gleason Score ≥8 PCa but not patients with Gleason Score 4+3 PCa, but offers greater confidence than CTC counts in identifying patients with metastatic prostate cancer. CTC Subclass analysis was also not effective for post-prostatectomy follow up and for distinguishing metastatic PCa and localized PCa patients. Nanoscale flow cytometry of PMPs presents an emerging biomarker platform for various stages of prostate cancer.

60 APPLIED LIFE SCIENCES↗

Quality Assurance Program Application for the Component Test Capability

This paper documents the application of quality requirements to Component Test Capability (CTC) Project activities for each CTC alternative. Four alternatives are considered for quality program application: do nothing, vendor testing, existing testing facility modification, and Component Test Facility. It also describes the advantages and disadvantages of using the existing Next Generation Nuclear Plant Quality Program Plan with CTC modifications versus a stand-alone CTC Quality Program Plan.

42 ENGINEERING↗

Administration of Concurrent Vaginal Brachytherapy During Chemotherapy for Treatment of Endometrial Cancer

Purpose: To evaluate the tolerability and toxicity of administering vaginal brachytherapy (VB) concurrently during chemotherapy compared with the sequential approach for patients with endometrial cancer. Methods and Materials: A retrospective analysis of 372 surgically staged patients with endometrial cancer American Joint Committee on Cancer 2009 stages I to IV treated with adjuvant postoperative radiation therapy (RT) at our institution from 2001 to 2012 was conducted. All patients received VB + external beam RT (EBRT) + 6 cycles of adjuvant carboplatin- and paclitaxel-based chemotherapy. The VB mean dose was 15.08 Gy (range, 15-20 Gy), with 3 to 4 weekly applications, and the EBRT mean dose was 45 Gy delivered with 3-dimensional or intensity modulated RT techniques. Hematologic, gastrointestinal (GI), and genitourinary (GU) toxicities were assessed by Common Toxicity Criteria (CTC) and compared between sequential and concurrent chemotherapy and VB schedules. Results: Among patients who received RT and adjuvant chemotherapy, 180 of 372 patients (48%) received RT sandwiched between cycles 3 and 4 of chemotherapy. A separate group of 192 patients (52%) were treated with VB during the first 3 cycles of chemotherapy, with a weekly application on nonchemotherapy days, and received the EBRT portion in a sandwiched fashion. Patients treated with VB during chemotherapy had a decreased overall treatment time by 4 weeks (P<.001; 95% confidence interval: 3.99-4.02) and sustained no difference in CTC-graded acute hematologic, GI, or GU toxicities in comparison with the patients treated with VB and chemotherapy in a sequential manner (P>.05). CTC grade 3 or 4 hematologic, GI, and GU toxicities were zero. Conclusions: VB during chemotherapy is well tolerated, decreases overall treatment time, and does not render more toxicity than the sequential regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Blind, Placebo-Controlled Pilot Study of Processed Ultra Emu Oil Versus Placebo in the Prevention of Radiation Dermatitis

Purpose: The purpose of this single-institution pilot study was to evaluate the feasibility and safety of an oil-based skin agent, Ultra Emu Oil, on skin-related toxicity in patients undergoing radiation therapy to the breast or chest wall. Methods and Materials: Patients were randomized 2:1 in a double-blind fashion and were instructed to apply processed Ultra Emu Oil or placebo (cottonseed oil) twice daily during the course of radiation therapy. The oils were applied before the third fraction and continued for 6 weeks after completion of treatment. The primary endpoint was the area under the curve (AUC) of Skindex-16 scale scores over time. Secondary outcomes included maximum grade of radiation dermatitis using the Common Terminology Criteria (CTC) for Adverse Events (CTCAE 3.0), the Skin Toxicity Assessment Tool, quality of life (QOL) measured by Linear Analogue Self-Assessment, and a symptom experience diary (SED). Results: In all, 42 of 45 patients completed the study and were evaluable. The median times to peak rash, skin redness, peeling, and skin swelling were weeks 6, 6, 7, and 7, respectively as measured by the SED. The Skindex AUC scores tended to be lower in emu oil patients than in placebo patients (mean total AUC 7.2 vs 10.4, respectively). This trend was also seen in all the Skindex subdomains. The overall QOL was slightly better in the emu oil group but remained stable throughout the study for both arms. Peak CTC toxicity occurred at week 6. Patients using emu oil appeared slightly worse on maximum CTC grade, but the difference was not significant. Conclusions: This pilot study confirmed the safety of oil-based skin treatments during radiation therapy and suggests a trend for reduced skin toxicity for patients receiving emu oil. A larger study is needed to evaluate the efficacy of emu oil in reducing radiation dermatitis in patients receiving breast radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational ranking identifies Plexin-B2 in circulating tumor cell clustering with monocytes in breast cancer metastasis

Abstract Multicellular circulating tumor cell (CTC) clusters can be up to 50 times more efficient than single CTCs in mediating viable metastasis. Here, combining computational ranking and functional determination, we identify the transmembrane protein Plexin-B2 (PLXNB2) as one of the top molecular targets associated with unfavorable distant metastasis-free survival, showing enriched expression in CTC clusters versus single CTCs from patients with advanced breast cancer (mostly female). Loss of PLXNB2 (Plxnb2) reduces the formation of homotypic tumor cell clusters and heterotypic tumor-myeloid cell clusters, reducing spontaneous metastases in female mice bearing human (mouse) breast cancer. Interactions of PLXNB2 with its ligands SEMA4C on tumor cells and SEMA4A on myeloid cells (monocytes) promote homotypic and heterotypic CTC cluster formation, respectively, thereby driving lung metastasis. Global proteomic analysis reveals downstream effectors of the PLXNB2 pathway associated with tumor cell clustering. Thus, PLXNB2 is a therapeutic target for preventing new metastasis in breast cancer.

Science & Technology - Other Topics↗

Discrepancy in the Critical State Void Ratio of Poorly Graded Sand due to Shear Strain Localization

The critical state (CS) concept is a theoretical framework that models the constitutive behavior of soils, including sand and other granular materials. It supports the notion of a unique postfailure state, where the soil ultimately experiences continuous shearing with no change in the plastic volumetric strain. However, the published literature has frequently noted the nonconvergence of sand specimens with different initial densities to a unique CS in the compression plane due to many factors such as specimen fabric, particle morphology, breakage, and grain size distribution. This paper examines the CS for poorly graded (uniform) glass beads and 3 different types of silica sands using 50 conventional triaxial compression (CTC) experiments, 12 oedometer tests, and in situ synchrotron microcomputed tomography (SMT) scans for 10 CTC experiments. The results of the 50 CTC experiments revealed a diffused CS zone in the compression plane, which was further examined using the in situ SMT scans. A thorough three-dimensional image analysis of the SMT scans accurately quantified the evolution of the local void ratio (elocal) versus axial compression within zones of intensive shearing toward the center of the specimen. The evolution of the void ratio was also measured using the entire volume of the specimen (eglobal). At the CS, the elocal/eglobal ratio was assessed to be ~1.25 when a single shear band developed within the scanned specimens and ~1.1-1.15 for specimens that failed via external bulging that was internally manifested by the development of multiple shear bands. This finding suggests that the CS zone in the compression plane can be attributed to the common wrong consideration of eglobal evolution in lieu of elocal within the developing shear bands. Furthermore, the lack of shear band development in uniaxial compression has made the results of the oedometer test reliable in quantifying the CS parameters in the compression plane.

58 GEOSCIENCES↗

Purification of mixed states with closed timelike curve is not possible

In ordinary quantum theory, any mixed state can be purified in an enlarged Hilbert space by adding an ancillary system. The purified state does not depend on the state of any extraneous system with which the mixed state is going to interact or on the physical interaction. Here, we prove that it is not possible to purify a mixed state that traverses a closed timelike curve (CTC) and is allowed to interact in a consistent way with a causality-respecting (CR) quantum system in the same manner. In other words, if a CTC quantum system with a mixed state has to undergo an arbitrary interaction with an arbitrary CR system then it has to be in a ''proper'' mixture, as it cannot be regarded as a subsystem of a pure entangled state. Thus, in general for arbitrary interactions between CR and CTC systems, there is no universal purification by embedding in a larger Hilbert space for mixed states with CTCs. This shows that in quantum theory with CTCs there can exist proper and improper mixtures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tuning between continuous time crystals and many-body scars in long-range XYZ spin chains.

Persistent oscillatory dynamics in nonequilibrium many-body systems is a tantalizing manifestation of ergodicity breakdown that continues to attract much attention. Recent works have focused on two classes of such systems: discrete time crystals and quantum many-body scars (QMBS). While both systems host oscillatory dynamics, its origin is expected to be fundamentally different: discrete time crystal is a phase of matter which spontaneously breaks the Z 2 symmetry of the external periodic drive, while QMBS span a subspace of nonthermalizing eigenstates forming an su(2) algebra representation. Here, we ask a basic question: is there a physical system that allows us to tune between these two dynamical phenomena? In contrast to much previous work, we investigate the possibility of a continuous time crystal (CTC) in undriven, energy-conserving systems exhibiting prethermalization. We introduce a long-range XYZ spin model and show that it encompasses both a CTC phase as well as QMBS. We map out the dynamical phase diagram using numerical simulations based on exact diagonalization and time-dependent variational principle in the thermodynamic limit. We identify a regime where QMBS and CTC order coexist, and we discuss experimental protocols that reveal their similarities as well as key differences.

Bull, Kieran↗

Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided doses over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-aided detection of renal calculi from noncontrast CT images using TV-flow and MSER features

Purpose: Renal calculi are common extracolonic incidental findings on computed tomographic colonography (CTC). This work aims to develop a fully automated computer-aided diagnosis system to accurately detect renal calculi on CTC images. Methods: The authors developed a total variation (TV) flow method to reduce image noise within the kidneys while maintaining the characteristic appearance of renal calculi. Maximally stable extremal region (MSER) features were then calculated to robustly identify calculi candidates. Finally, the authors computed texture and shape features that were imported to support vector machines for calculus classification. The method was validated on a dataset of 192 patients and compared to a baseline approach that detects calculi by thresholding. The authors also compared their method with the detection approaches using anisotropic diffusion and nonsmoothing. Results: At a false positive rate of 8 per patient, the sensitivities of the new method and the baseline thresholding approach were 69% and 35% (p < 1e − 3) on all calculi from 1 to 433 mm{sup 3} in the testing dataset. The sensitivities of the detection methods using anisotropic diffusion and nonsmoothing were 36% and 0%, respectively. The sensitivity of the new method increased to 90% if only larger and more clinically relevant calculi were considered. Conclusions: Experimental results demonstrated that TV-flow and MSER features are efficient means to robustly and accurately detect renal calculi on low-dose, high noise CTC images. Thus, the proposed method can potentially improve diagnosis.

60 APPLIED LIFE SCIENCES↗

Design of Novel Hot Gas Component for Gas Turbine Engines Enabled by Materials and Additive Manufacturing Process Development

This CRADA project was the result of a project award under FOA-DOE-0001980. The overarching FOA project team consisted of researchers from Carpenter Technology Corporation (CTC), Solar Turbines Incorporated (Solar), Pennsylvania State University (PSU), University of California-Santa Barbara (UCSB), and Oak Ridge National Laboratory (ORNL). Evaluations were conducted on two high-γ’ superalloys that were designed by CTC and the UCSB. One alloy named GammaPrint-700 (GP-700) is a cobalt-base superalloy. The other alloy named GammaPrint-1100 (GP-1100) is a nickel-base (Ni-base) superalloy. PSU provided expertise and experimental testing of the thermal performance of AM micro-cooling architectures. ORNL provided expertise with the AM superalloy materials characterization and AM processing science. Solar provided turbine component design expertise. The focus of this CRADA report is to document the efforts between ORNL and CTC towards the development of superalloys designed for AM. The project goal was to use an AM processable high-temperature superalloy and design for Additive Manufacturing (DfAM) techniques to design an efficient turbine component (i.e. a turbine tip shoe) with enhanced cooling features that can only be fabricated through additive manufacturing (AM). The efficiencies of existing combined heat and power (CHP) engines are capped by both component design and materials limitations. However, AM of a tip shoe component from a γ’strengthened superalloy offers the design flexibility to increase the efficiency and power of an industrial gas turbine. This project brought about advancements in the DfAM tip shoe design space and in the area of high temperature superalloys processable through laser powder bed fusion (LPBF) AM. State of art computation design tools were utilized to optimize unique cooling features into a tip shoe component design. A two-prong materials development approach was taken to support development of the AM tip shoe geometry. The first approach centered on investigating the processability and the appropriate process science for the industry standard high-γ’ nickel-base (Ni-base) superalloy Mar-M247. This superalloy is typically cast and considered non-weldable by traditional welding standards. In the course of this work, the alloy was not deemed feasible for process scale-up due to significant cracking issues during printing. The second approach focused on the development and evaluation of a novel cobalt-base superalloy, GammaPrint™-700 (GP-700 and a Ni-base superalloy, GammaPrint™-1100 (GP-1100) designed to mitigate the significant AM processing issues with Mar-M247. The processability of these two alloys were investigated through electron beam melting (EBM) binder-jet AM (BJAM), and LPBF as a risk mitigation for manufacturability. To be considered a candidate material for down-selection to proceed to full-scale AM tip shoe engine testing trials, the high temperature creep rupture strength was required to achieve at a minimum, a Larsen Miller Parameter (LMP) increase of 10.9% over the baseline material LPBF AM Hastelloy X.

99 GENERAL AND MISCELLANEOUS↗