Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Use of Mini-CT Specimens for Fracture Toughness Characterization of Irradiated Highly Embrittled Weld

In the 1990’s, the Heavy Section Steel Irradiation Program at the ORNL performed investigation of the shape of the fracture toughness master curve for reactor pressure vessel steel highly embrittled because of irradiation exposure. A radiation-sensitive reactor pressure vessel (RPV) weld with intentionally enhanced copper content, designated KS-01, has been characterized in terms of static initiation (KJc) and Charpy impact toughness in the unirradiated and irradiated conditions. The objective of this original project was to investigate the ability of highly embrittled material to maintain the shape of the unirradiated transition fracture toughness curve, as well as to examine the ability of the Charpy 41-J shift to predict the fracture toughness shift at such high level of embrittlement. Irradiation of this weld was performed at the University of Michigan Ford Reactor in the new HSSI irradiation-anneal-reirradiation (IAR) facility. Broken specimens from that project have been saved in ORNL storage. To verify applicability of Mini-CT specimens for fracture toughness characterization of RPV materials as part of the DOE Light Water Reactor Sustainability Program, Mini-CT specimens were machined from broken Charpy specimens and tested according to ASTM E1921 standard. As result of this study, the fracture toughness of this weld derived by testing Mini-CT specimens in the unirradiated and irradiated conditions is compared to previously reported fracture toughness derived by large number of conventional specimens.

Sokolov, Mikhail A.↗

A New Workflow of X-ray CT Image Processing and Data Analysis of Structural Features in Rock Using Open-Source Software

X-ray computed tomography (CT) images of rock specimens often contain artifacts which must be corrected before scientific analyses are performed. Here, we present a new workflow of automated image processing to utilize poor-quality X-ray CT scan images. The workflow runs on the open-source image analysis software and efficiently separates desired features from low-contrast scanned images. The new workflow is a two-step technique using contrast enhancement and automated feature segmentation to generate noise-free binary images. The results of binary images using the proposed workflow and using a conventional thresholding technique are analyzed to show the quality of the proposed method. The paper also presents a workflow of estimating the structural geometries of features in two and three dimensions. The results of the structural feature analyses and computational time were compared between the open-source (ImageJ) and commercial image analysis software (Bruker Computed Tomography Analyzer). The commercial software was more computationally efficient, but the task-specific macros in open-source software enabled the user-desired automation in image processing and data extraction of desired structural features of comparable quality.

47 OTHER INSTRUMENTATION↗

Role of Surface Termination in the Structural and Electronic Properties of Sc$_2$CT$_\textrm{x}$ MXene

Graphene-like layered transition metal carbides, nitrides, or carbonitrides, called MXenes, obey the stoichiometric formula of M n+1 X n T x , where M is an early transition metal such as scandium (Sc), n is a natural number, X is C, N, or CN, and T x is a functional group such as –O, –F, or –OH that passivates the surface of the MXene. The electronic structure of bare Sc 2 C and functionalized Sc 2 CT x MXenes are explored by performing first-principles density functional theory (DFT) calculations. The bare Sc 2 C is metallic, but less stable than its passivated structure. The Sc 2 C MXene has an interlayer 2D electron gas not bound to Sc or C atoms but free to move, making it an electride. DFT calculations show that functionalization can open an energy gap in Sc 2 CT x MXenes. The size and type (direct versus indirect) of the bandgap vary with the functional groups, which provides a means for opening and tuning of the band gap.

DFT↗

Uncertainty quantification of the convolutional neural networks on permeability estimation from micro-CT scanned sandstone and carbonate rock images

Rock permeability is one of the most crucial properties affecting subsurface fluid flow behaviors. To accurately and robustly estimate the permeability, Digital Rock Physics, including micro-CT scanning technology and direct flow simulations on scanned images, has prevailed in recent years. Besides, machine learning techniques such as convolutional neural networks (CNNs) have been widely adopted and achieved success in permeability estimations directly from rock images. However, existing ML methods used for permeability estimation from rock images lack uncertainty quantification that causes unreliable predictions and overconfident estimations on out-of-distribution (OOD) samples. Here, in this work, we propose a PI3NN-CNN framework to address this problem. PI3NN-CNN consists of a CNN model for absolute permeability estimation and a PI3NN method to quantify the estimation uncertainty. It is able to quantify the uncertainty for in-distribution (InD) data with a desired confidence level, and identify OOD samples to avoid overconfident predictions. We demonstrate the method using micro-CT scanned images from two sandstone and two carbonate rocks. We found that PI3NN-CNN generates accurate predictions for InD samples, while producing high-quality prediction uncertainties regardless of the prediction accuracy. Meanwhile, PI3NN-CNN identifies OOD samples using its special network initialization scheme. The unique feature of PI3NN-CNN makes it applicable to more complex real-world image-based data for robust learning and predictions without overconfident estimations when the ground-truth information is unavailable.

58 GEOSCIENCES↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

An investigation of fracture behaviors of NBG-18 nuclear graphite using in situ mechanical testing coupled with micro-CT

Nuclear graphite contains defects spanning from nanoscale basal cracks to sub-mm scale voids. This study aims to establish an experimental method to investigate pre-existing defects and 3-D crack growth inside nuclear graphite, NBG-18. Three-point bending tests were performed on single-edge notched beam specimens with and without coupling with micro-CT. The fracture toughness was measured to be 1.17 ± 0.06 MPa $\sqrt{{m}}$. Cracks were observed to initiate from the pores and thermal cracks on the edge of the notch and then defect or twist to grow along the pre-existing defects. Crack bridging, defection, and twisting were the primary toughening mechanisms. The crack resistance curve exhibited a trend of rising-plateau-rising that can be related to the interaction of crack front and the pre-existing defects. In conclusion, the results highlight the capability of laboratory micro-CT-based experimental method for the visualization of multi-scale defect interactions, which remains to be a challenge in the characterization of nuclear graphite.

36 MATERIALS SCIENCE↗

Computed Tomography (CT) Analysis of 3D Printed Lattice Structures

LATTICE structures are increasingly used in product design across different industries, including the Department of Energy (DOE), due to their high strength and lightweight properties. These structures possess qualities such as high stiffness, energy absorption, large surface area, and structural support. To ensure lattice structures' quality and symmetry, it is crucial to have defect-free structures. However, in some cases, traditional non-destructive evaluation methods may not be practical due to encasing lattice structures in material. To analyze the lattice structures' quality, this project will employ CT imaging to gain access to the encased structures and perform a detailed analysis of each section. Three 3D printed complex lattice cubes were created, with two exposed and one encased in material, for this project. The CT X-ray cabinet will be used to scan all three cubes, and the data collected will be reconstructed and evaluated using complex interpretation software. This analysis will allow for a detailed examination of the structure's porosity, inclusions, cracks, wall thickness, and symmetry in each section.

36 MATERIALS SCIENCE↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

Physics guided machine learning for multi-material decomposition of tissues from dual-energy CT scans of simulated breast models with calcifications

We introduce a physics guided data-driven method for image-based multi-material decomposition for dual-energy computed tomography (CT) scans. The method is demonstrated for CT scans of virtual human phantoms containing more than two types of tissues. The method is a physics-driven supervised learning technique. We take advantage of the mass attenuation coefficient of dense materials compared to that of muscle tissues to perform a preliminary extraction of the dense material from the images using unsupervised methods. We then perform supervised deep learning on the images processed by the extracted dense material to obtain the final multi-material tissue map. The method is demonstrated on simulated breast models with calcifications as the dense material placed amongst the muscle tissues. The physics-guided machine learning method accurately decomposes the various tissues from input images, achieving a normalized root-mean-squared error of 2.75%.

Gopalakrishnan Meena, Murali↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

CT Scans of Cores Metadata, Utqiagvik (Barrow), Alaska, 2015

Individual ice cores were collected from Barrow Environmental Observatory in Barrow, Alaska, throughout 2013 and 2014. Cores were drilled along different transects to sample polygonal features (i.e. the trough, center and rim of high, transitional and low center polygons). Most cores were drilled around 1 meter in depth and a few deep cores were drilled around 3 meters in depth. Three-dimensional images of the frozen cores were constructed using a medical X-ray computed tomography (CT) scanner. TIFF files can be uploaded to ImageJ (an open-source imaging software) to examine soil structure and soil densities within each core.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Through-thickness fracture behavior of neutron-irradiated nuclear graphite NBG-17 Using X-ray micro-CT

Achieving precise control over crack propagation in nuclear graphite and conducting quantitative analysis remain challenging. In this study, the through-thickness fracture behavior of pristine and neutron-irradiated (700 °C, ∼7 dpa) NBG-17 nuclear graphite was investigated using split-disc testing coupled with micro-computed tomography (micro-CT). A notably lower number of micropores was observed in the neutron-irradiated specimen. The fracture toughness of neutron-irradiated NBG-17 was measured to be 1.45 MPa√m, compared to 1.17 ± 0.05 MPa√m for the pristine specimen. In both materials, cracks were found to initiate at the filler–binder interface, and often correlated with microstructural features such as pores and thermal cracks. Crack bridging and deflections emerged as the primary toughening mechanisms in both unirradiated and irradiated NBG-17. However, compared with the pristine specimen, the cracks in the neutron-irradiated specimen were more likely to grow trans granularly, resulting in less deflected crack paths. The reduced micro-porosity and strengthened filler–binder boundaries were considered to be the cause of the observed differences in crack morphologies. In conclusion, this study provides a qualitative analysis of the fracture behavior of neutron-irradiated nuclear graphite in the absence of radiolytic oxidation.

36 - MATERIALS SCIENCE↗

Effect of chemical substitution and external strain on phase stability and ferroelectricity in two dimensional M 2 CT 2 MXenes

Two dimensional ferroelectric materials are gaining increasing attention for use in ultrathin electronic devices owing to the presence of a spontaneous polarization down to one or two monolayers. However, such materials are difficult to identify, especially those with out-of-plane electric polarizations. Previous work predicted that a metastable ferroelectric phase exists in the 2D MXene Sc 2 CO 2 , while further studies have predicted that this phase exists in other MXene chemistries. However, questions remain about the origin of ferroelectricity, the stability of this phase relative to other competing phases, and the effect of external stimuli in these materials. In this work, we use density functional theory calculations to investigate 12 M 2 CT 2 MXenes (M = transition metal, T = surface terminating group) and determine which have the ferroelectric phase as their ground state. We compute these materials’ polarizations, densities of states, phonon band structures, Bader charges, and Born effective charges in the ferroelectric phase to elucidate the reasons for its stabilization. We demonstrate that this ferroelectric phase can be preferentially stabilized in non-ferroelectric MXenes through full chemical substitution of Sc or O, alloying of the Sc sites, or application of epitaxial strain. Finally, we show that these materials have excellent piezoelectric properties as well. This work provides a detailed understanding of ferroelectric MXenes and show how the number of 2D ferroelectric materials can be increased through chemical substitution or application of external stimuli.

36 MATERIALS SCIENCE↗

Correlating electronic properties with M-site composition in solid solution Ti y Nb 2- y CT x MXenes

High electrical conductivity is desired in MXene films for applications such as electromagnetic interference shielding, antennas, and electrodes for electrochemical energy storage and conversion applications. Due to the acid etching-based synthesis method, it is challenging to deconvolute the relative importance that factors such as chemical composition and flake size contribute to resistivity. To understand the intrinsic and extrinsic contributions to the macroscopic electronic transport properties, a systematic study controlling compositional and structural parameters was conducted with eight solid solutions in the Ti y Nb 2-y CT x system. Here, in particular, we investigated the different roles played by metal (M)-site composition, flake size, and d-spacing on macroscopic transport. Hard x-ray photoemission spectroscopy and spectroscopic ellipsometry revealed changes to electronic structure induced by the M-site alloying. Consistent with the spectroscopic results, the low- and room-temperature conductivities and effective carrier mobility are correlated with the Ti content, while the impact of flake size and d-spacing is most prominent in low-temperature transport. The results provide guidance for designing and engineering MXenes with a wide range of conductivities.

36 MATERIALS SCIENCE↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Micro-CT Imaging and Fluid Flow Simulations of Fractures in MSEEL Shale

micro-CT scans of a naturally fractured MSEEL shale sample as a shear fracture is generated and displaced in the center, intact region of the sample. Steady State laminar fluid flow simulations were then performed on each individual fracture during each experimental segment as effective stress and shear displacement changed. Released under LA-UR-21-24335.

Fractures,Fracturing Initiation,Marcellus Shale↗