Investigation of external refrigeration systems for long term cryogenic storage
Selection and optimization of space cryogenic storage tanks
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Selection and optimization of space cryogenic storage tanks
Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments.
Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments.
Cryogenic fluid storage on moon surface, considering Lambert reflection law, thermal insulation performance, incident heat flux and boil-off rates
Performance of cryogenic liquid shroud insulation for cryogenic fluid storage system
Supercritical cryogenic electric power system storage for gemini and apollo projects by use of a set of pressure-enthalpy and temperature-entropy diagrams
Evaluation of cryogenic refrigeration systems for space applications
The Long Term Cryogenic Storage Facility Systems Study (LTCSFSS) is a Phase A study of a large capacity propellant depot for the space based, cryogenic orbital transfer vehicle. The study is being performed for Marshall Space Flight Center by General Dynamics Space Systems Division and has five principal objectives: (1) Definition of preliminary concept designs for four storage facility concepts; (2) Selection of preferred concepts through the application of trade studies to candidate propellant management system components; (3) Preparation of a conceptual design for an orbital storage facility; (4) Development of supporting research and technology requirements; and (5) Development of a test program to demonstrate facility performance. The initial study has been completed, and continuation activities are just getting under way to provide greater detail in key areas and accommodate changes in study guidelines and assumptions.
Development of cryogenic storage systems for manned space flight
The thermal stresses on a cryogenic storage tank contribute strongly to the state of stress of the tank material and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A previous preliminary elastic analysis showed that the thermal stress on the inner wall would reach approximately 1,000MPa (145,000 psi). This stress far exceeds the ASTM specified room temperature values for both yield (170MPa) and ultimate (485 MPa) strength for 304L stainless steel. The present analysis determines the thermal stresses using an elastic-plastic model. The commercial software application ANSYS was used to determine the transient spatial temperature profile and the associated spatial thermal stress profiles in a segment of a thick-walled vessel during a typical cooldown process. A strictly elastic analysis using standard material properties for 304L stainless steel showed that the maximum thermal stress on the inner and outer walls was approximately 960 MPa (tensile) and - 270 MPa (compressive) respectively. These values occurred early in the cooldown process, but at different times, An elastic-plastic analysis showed significantly reducing stress, as expected due to the plastic deformation of the material. The maximum stress for the inner wall was approximately 225 MPa (tensile), while the maximum stress for the outer wall was approximately - 130 MPa (compressive).
The topics are presented in viewgraph form and include the following: an assessment of cryogenic storage technology; cryogenic boiloff predictions; Space Shuttle/Centaur thermodynamic vent system; zero-g thermodynamic vent system; heat exchanger/mixer pump module; the thick multilayer insulation (MLI) development program; blanket geometry concept evaluations; four-inch thick MLI system on 1/4-scale test tank; combined environments of vibration, acceleration, and temperature testing (CEVAT); Centaur fixed foam insulation; insulation system design; and fixed foam on operational Atlas 2.
Thick superinsulation system design for long term cryogenic storage using superfloc, radiation shield and spacer material
A unique multilayer insulation concept for orbital cryogenic storage was experimentally evaluated at NASA Marshall Space Flight Center (MSFC) using the Multipurpose Hydrogen Test Bed (MHTB). A combination of foam/Multi layer Insulation (MLI) was used. The MLI (45 layers of Double Aluminized Mylar (DAM) with Dacron net spacers) was designed for an on-orbit storage period of 45 days and included several unique features such as: a variable layer density and larger but fewer DAM perforations for venting during ascent to orbit. The focus of this paper is on analytical modeling of the variable density MLI performance during orbital coast periods. The foam/MLI combination model is considered to have five segments. The first segment represents the foam layer. The second, third, and fourth segments represent the three layers of MLI with different layer densities and number of shields. Finally, the last segment is considered to be a shroud that surrounds the last MLI layer. The hot boundary temperature is allowed to vary from 164 K to 305 K. To simulate MLI performance, two approaches are considered. In the first approach, the variable density MLI is modeled layer by layer while in the second approach, a semi-empirical model is applied. Both models account for thermal radiation between shields, gas conduction, and solid conduction through the separator materials. The heat flux values predicted by each approach are compared for different boundary temperatures and MLI systems with 30, 45, 60, and 75 layers.
Predicting flight performance of cryogenic storage system for Apollo 15
Handbook of external refrigeration systems for long term cryogenic storage
Storage and transfer of cryogenic liquefied gases on volume scales from under 10 liters for lab use, up to hundreds of millions of liters for industrial applications is of paramount importance across a vast range of industries. Traditionally, these commodities have been stored at or near the normal boiling point due to relative ease of operation and safety-related considerations; however, this also means that some percentage will always be lost due to environmental heat leaking into the vessel and causing boil-off. These losses become more concerning as scales increase, and are of particular importance for high-cost commodities such helium and hydrogen. Additionally, the normal boiling point marks the highest liquid density achievable; which becomes a strong driver of end-use system designs such as space launch vehicles. Recent development and testing of an Integrated Refrigeration and Storage (IRAS) system for liquid hydrogen has proven that next generation cryogenic storage operations such as zero boil-off and densification are feasible on a large scale. This IRAS system married an 850 Watt at 20 Kelvin reverse-Brayton cycle commercial cryogenic refrigerator with a 125,000 liter LH2 storage tank via and internal tubular heat exchanger. This allowed heat to be removed directly from the hydrogen, and by extension, provided a means to control the bulk thermodynamic state. Zero boil-off, in-situ liquefaction, and densification down to the triple point was performed during testing, and data such as fluid temperature profiles and tank pressure were gathered. Details regarding the design, setup, and testing of the IRAS system are discussed herein, and the data used to anchor various physics models created to predict the behavior of the system during transient and steady state operation. It is hoped that these efforts will provide a useful basis for the design and implementation of future large scale IRAS systems across numerous industries.
A unique foam/Multilayer Insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated at NASA Marshall Space Flight Center (MSFC) using the Multipurpose Hydrogen Test Bed (MHTB). The MLI was designed for an on-orbit storage period of 45 days and included several unique features such as: a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or heat leak is reduced by about half in comparison with standard MLI. The focus of this paper is on analytical modeling of the Variable Density MLI (VD-MLI) on-orbit performance (i.e. vacuum/low pressure environment). The foam/VD-MLI combination model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three MLI segments with different layer densities. The last segment is considered to be a shroud that surrounds the last MLI layer. Two approaches are considered. In the first approach, the variable density MLI is modeled layer by layer while in the second approach, a semi-empirical model is applied. Both models account for thermal radiation between shields, gas conduction, and solid conduction through the layer separator materials.
A unique foam/multilayer insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated using a large-scale hydrogen tank. The foam substrate insulates for ground-hold periods and enables a gaseous nitrogen purge as opposed to helium. The MLI, designed for an on-orbit storage period for 45 days, includes several unique features including a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or tank heat leak is reduced by about half in comparison with standard MLI. The focus of this effort is on analytical modeling of the variable density MLI (VD-MLI) on-orbit performance. The foam/VD-MLI model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three different MLI layer densities. The last segment is an environmental boundary or shroud that surrounds the last MLI layer. Two approaches are considered: a variable density MLI modeled layer by layer and a semiempirical model or "modified Lockheed equation." Results from the two models were very comparable and were within 5-8 percent of the measured data at the 300 K boundary condition.