Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Note: Simple calibration of the counting-rate dependence of the timing shift of single photon avalanche diodes by photon interval analysis

The counting-rate dependence of the temporal response of single photon avalanche diodes (SPADs) is a critical issue for the accurate determination of the fluorescence lifetime. In this study, the response of SPADs was examined with analyzing the time interval of the detected photons. The results clearly show that the shift of the detection timing causes the counting-rate dependence of the temporal response, and this timing shift is solely determined by the time interval from the preceding photon. We demonstrate that this timing instability is readily calibrated by utilizing the macrotime data taken with the time-tag mode that is implemented in the time-correlated single photon counting modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Count Rate Beam Monitor for Thermal Neutrons

Beam monitors are an important diagnostic tool in neutron science facilities. Present beam monitors use either ionization chambers in integration mode, which are slow and have no timing information, or pulse counters which can easily be saturated by high beam intensities. Neutron beam monitors indicate the number of neutrons incident on a scattering sample and allow neutron experimental data to be analyzed even when the source strength varies with time. At high flux neutron scattering facilities, neutron beam monitors with very low efficiency (10-5) are presently selected to keep the counting rate within a feasible range, even when a higher efficiency would improve the counting statistics and yield a better measurement of the incident beam. In this work, we report on a high count rate neutron beam monitor which also offers position sensitivity to provide a beam profile. This beam monitor offers good timing (less than 1 s) in addition to position resolution and will therefore improve the counting statistics at neutron energies up to 10 eV and allow moderator studies. The detector s main characteristics will be presented including its background rate, its count rate capability which is an order of magnitude higher than present counting monitors, and its efficiency for thermal neutrons.

Barnett, Amanda↗

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADONIS, high count-rate HP-Ge {gamma} spectrometry algorithm: Irradiated fuel assembly measurement

ADONIS is a digital system for gamma-ray spectrometry, developed by CEA. This system achieves high count-rate gamma-ray spectrometry with correct dynamic dead-time correction, up to, at least, more than an incoming count rate of 3.10{sup 6} events per second. An application of such a system at AREVA NC's La Hague plant is the irradiated fuel scanning facility before reprocessing. The ADONIS system is presented, then the measurement set-up and, last, the measurement results with reference measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects, determination, and correction of count rate nonlinearity in multi-channel analog electron detectors

Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We focus on a nearly ubiquitous “inverse saturation” nonlinearity that makes the spectra falsely sharp and beautiful. These artificially enhanced spectra limit accurate quantitative analysis of the data, leading to mistaken spectral weights, Fermi energies, and peak widths. We present a method to rapidly detect and correct for this nonlinearity. This algorithm could be applicable for a wide range of nonlinear systems, beyond photoemission spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guidance on the Use of Hand-Held Survey Meters for radiological Triage: Time-Dependent Detector Count Rates Corresponding to 50, 250, and 500 mSv Effective Dose for Adult Males and Adult Females

In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially larger numbers of individuals (100 s to 1,000 s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated by the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (G50, 50Y250, 250Y500, and 9500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances. Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Special Nuclear Material Mass Estimates from Neutron Singles Count Rate [Poster]

The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.

FLIR↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Tantalum STJ X-ray Detectors at Elevated Count Rates

Here, we have developed an X-ray detector system based on Ta superconducting tunnel junctions (STJs) with an energy resolution below 10 eV under 1 keV. A principal advantage of STJs over other low-temperature detectors is their high count rate capability. In this work, we have optimized the operating conditions and digital pulse processing parameters for input count rates up to 25 kcps/pixel. Resolution below 10 eV is maintained up to 2.5 kcps/pixel, and at input rates of 25 kcps per pixel the resolution is 26 eV FWHM at 525 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear photonics at ultra-high counting rates and higher multipole excitations

Next-generation {gamma} beams from laser Compton-backscattering facilities like ELI-NP (Bucharest)] or MEGa-Ray (Livermore) will drastically exceed the photon flux presently available at existing facilities, reaching or even exceeding 10{sup 13}{gamma}/sec. The beam structure as presently foreseen for MEGa-Ray and ELI-NP builds upon a structure of macro-pulses ({approx}120 Hz) for the electron beam, accelerated with X-band technology at 11.5 GHz, resulting in a micro structure of 87 ps distance between the electron pulses acting as mirrors for a counterpropagating intense laser. In total each 8.3 ms a {gamma} pulse series with a duration of about 100 ns will impinge on the target, resulting in an instantaneous photon flux of about 10{sup 18}{gamma}/s, thus introducing major challenges in view of pile-up. Novel {gamma} optics will be applied to monochromatize the {gamma} beam to ultimately {Delta}E/E{approx}10{sup -6}. Thus level-selective spectroscopy of higher multipole excitations will become accessible with good contrast for the first time. Fast responding {gamma} detectors, e.g. based on advanced scintillator technology (e.g. LaBr{sub 3}(Ce)) allow for measurements with count rates as high as 10{sup 6}-10{sup 7}{gamma}/s without significant drop of performance. Data handling adapted to the beam conditions could be performed by fast digitizing electronics, able to sample data traces during the micro-pulse duration, while the subsequent macro-pulse gap of ca. 8 ms leaves ample time for data readout. A ball of LaBr{sub 3} detectors with digital readout appears to best suited for this novel type of nuclear photonics at ultra-high counting rates.

43 PARTICLE ACCELERATORS↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms of pulse shape analysis for Gammasphere under high count rate conditions

The implementation of digital electronics for the multi-detector Gammasphere array has provided an opportunity to perform experiments which exceed the technical capabilities of its analog counterpart. The pulse shape analysis of HPGe detectors is presented for the purpose of determining the γ-ray energy under high-counting rates and short integration times with the aim of improving the data throughput. A revised trapezoidal algorithm is delineated which is able to determine the γ-ray energies during the offline analysis without being constrained by predetermined parameters. The performance of this algorithm is discussed, and compared with that of the analog system. The measured energy resolution meets expectations for operations with high-counting rates and short integration times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Transition-Edge Sensor Design for High Count-Rate Applications

We are developing transition-edge sensor (TES) X-ray detectors optimized for high count-rate applications. These devices are fabricated on thick (300 {mu}m) Si substrates, resulting in a 20 times increase in thermal conductance to the heat sink compared to our conventional membrane isolated TES's. Operating a TES with higher heat sink conductance requires 4.5 times more bias current. This results in a 2.7 times increase in {beta}, the logarithmic derivative of resistance with respect to current. Noise measurements show a lower limit on the TES excess noise scales as (2{beta}){sup 1/2}, consistent with the near-equilibrium, non-linear expansion of the Ohmic Johnson noise. This is consistent with our membrane devices though the increased {beta} means the theoretical best attainable resolution is degraded by 25-35%. We have tested devices with different contact geometries between the absorber, and the TES and substrate. This allows us to investigate the loss of athermal phonons to the substrate, which can degrade the resolution. Results show a correlation between the stem contact area and a low-energy tail in the spectral response at 5.9 keV due to the athermal phonon loss. In several devices tested we demonstrate a resolution of 4.1-5.6 eV, coupled with detector time constants as fast as 44 {mu}s, representing an increase in detector response by 7 times compared to the membrane devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a four-element Si drift detector for X-ray absorption fine-structure spectroscopy: resolution, maximum count rate, and dead-time correction with incorporation into the ATHENA data analysis software

The performance of a four-element Si drift detector for energy-dispersive fluorescence-yield X-ray absorption fine-structure measurements is reported, operating at the National Institute of Standards and Technology beamline X23A2 at the National Synchrotron Light Source. The detector can acquire X-ray absorption fine-structure spectra with a throughput exceeding 4 x 10{sup 5} counts per second per detector element (>1.6 x 10{sup 6} total counts per second summed over all four channels). At this count rate the resolution at 6 keV is approximately 220 eV, which adequately resolves the Mn K{sub {alpha}} and K{sup {beta}} fluorescence lines. Accurate dead-time correction is demonstrated, and it has been incorporated into the ATHENA data analysis program. To maintain counting efficiency and high signal to background, it is suggested that the incoming count rate should not exceed {approx}70% of the maximum throughput.

42 ENGINEERING↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High quantum efficiency and low dark count rate in multi-layer superconducting nanowire single-photon detectors

In this paper, we theoretically show that a multi-layer superconducting nanowire single-photon detector (SNSPD) is capable of approaching characteristics of an ideal SNSPD in terms of the quantum efficiency, dark count, and band-width. A multi-layer structure improves the performance in two ways. First, the potential barrier for thermally activated vortex crossing, which is the major source of dark counts and the reduction of the critical current in SNSPDs is elevated. In a multi-layer SNSPD, a vortex is made of 2D-pancake vortices that form a stack. It will be shown that the stack of pancake vortices effectively experiences a larger potential barrier compared to a vortex in a single-layer SNSPD. This leads to an increase in the experimental critical current as well as significant decrease in the dark count rate. In consequence, an increase in the quantum efficiency for photons of the same energy or an increase in the sensitivity to photons of lower energy is achieved. Second, a multi-layer structure improves the efficiency of single-photon absorption by increasing the effective optical thickness without compromising the single-photon sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coincident count rates in absorbing dielectric media

A study of the effects of absorption on the nonlinear process of parametric down-conversion is presented. Absorption within the nonlinear medium is accounted for by employing the framework of macroscopic QED and the Green tensor quantization of the electromagnetic field. An effective interaction Hamiltonian, which describes the nonlinear interaction of the electric field and the linear noise polarization field, is used to derive the quantum state of the light leaving a nonlinear crystal. The signal and idler modes of this quantum state are found to be a superposition of the electric and noise polarization fields. Using this state, the expression for the coincident count rates for both type-I and type-II down-conversion are found. The nonlinear interaction with the noise polarization field was shown to cause an increase in the rate on the order of 10{sup -12} for absorption of 10% per centimeter. This astonishingly small effect is found to be negligible compared to the decay caused by linear absorption of the propagating modes. From the expressions for the biphoton amplitude, it can be seen that the maximally entangled states can still be produced even in the presence of strong absorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗