An observational test of theories of neutron- star cooling.
Neutron star cooling tested by photon flux measurements indicative of effective temperature change
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Neutron star cooling tested by photon flux measurements indicative of effective temperature change
This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.
Abstract: This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.
This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass..
In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal variable conductance heat pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor by bypassing the heat during stops. In a previous NASA Small Business Innovation Research (SBIR) Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for the Stirling RPS. In 2012, one of these VCHPs was successfully tested at NASA Glenn Research Center with a Stirling convertor as an Advanced Stirling Radioisotope Generator (ASRG) backup cooling system. The prototype; however, was not optimized and did not reflect the final heat rejection path. ACT through further funding has developed a semioptimized prototype with the finalized heat path for testing at Glenn with a Stirling convertor. The semioptimized system features a two-phase radiator and is significantly smaller and lighter than the prior prototype to reflect a higher level of flight readiness. The VCHP is designed to activate and remove heat from the GPHS during stoppage with a small temperature increase from the nominal vapor temperature. This small temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the multilayer insulation (MLI). The VCHP passively allows the Stirling convertor to be turned off multiple times during a mission with potentially unlimited off durations. Having the ability to turn the Stirling off allows for the Stirling to be reset and reduces vibrations on the platform during sensitive measurements or procedures. This paper presents the design of the VCHP and its test results with a Stirling convertor at Glenn. Tests were carried for multiple on and off cycles to demonstrate repeatability. The impacts associated with the addition of the VCHP to the system are also addressed in terms of mass and additional heat losses due to the presence of the VCHP.
Film-cooling tests, with water as the coolant, were made on an 80 deg total-angle cone in a Mach number 2 free jet at sea-level pressure. The tests were made at free-stream total temperatures from 1,500 deg R to 3,000 deg R and at free-stream Reynolds numbers per foot from 8 x 10(exp 6) to 3 x 10(exp 6). The tests showed that the downstream end of the model became very hot if the coolant rate was too small to cover the complete model with a water film. This water film was fairly symmetrical when the model was at zero angle of attack but was very asymmetrical when the model was at an angle of attack of 5 deg. A comparison with results of a previous transpiration-cooling test showed that, with water as the coolant, transpiration cooling was at least 2.5 times as efficient as the film cooling of the present tests.
The method of differential similarity is applied to the partial differential equations and boundary conditions which govern the temperature, velocity, and pressure fields in the flowing gases and the solid stationary components in air-cooled engines. This procedure yields the nondimensional groups which must have the same value in both the test rig and the engine to produce similarity between the test results and the engine performance. These results guide the experimentalist in the design and selection of test equipment that properly scales quantities to actual engine conditions. They also provide a firm fundamental foundation for substantiation of previous similarity analyses which employed heuristic, physical reasoning arguments to arrive at the nondimensional groups.
Ceramic Matrix Composites (CMCS) offer the potential for significant weight savings and improved performance for a range of propulsion components utilizing refractory materials. This paper describes the fabrication and testing of functionally graded CMCs produced via a low cost process that represents an order of magnitude cost savings over conventionally fabricated CMCS. Test cylinders were fabricated, characterized and evaluated during exposure to high thermal fluxes of up to 10MW/meters squared at the Laser Hardened Materials Evaluation Laboratory (LHMEL). The bulk density of the CMC tubes was approximately 2.2 grams per cubic centimeters. The performance of cryogenically cooled CMCs was compared with uncooled CMCs against similar thermal loads, and fundamental property data collected for this relatively new breed of CMC. Finally, test thrust cells were fabricated from the functionally graded composite and tested using liquid H2 and O2 propellants at NASA Glen.
Flight 5 aft segments with nozzles were exposed to -17 F temperatures while awaiting shipment to KSC in February, 1989. No records were found which show that any previous nozzles were exposed to air temperatures as low as those seen by the Flight 5 nozzles. Thermal analysis shows that the temperature of the fixed housing, and forward and aft exit cone components dropped as low as -10 F. Structural analysis of the nozzles at these low temperatures show the forward and aft exit cone adhesive bonds to have a positive margin of safety, based on a 2.0 safety factor. These analyses show the normal and shear stresses in the fixed housing bond as low values. However, the hoop and meridinal stresses were predicted to be in the 4000 psi range; the failure stress allowable of EA913NA adhesive at -7 F. If the bonds did break in directions perpendicular to the surfaces, called bond crazing, no normal bond strength would be lost. Testing was conducted in two phases, showing that no degradation to the adhesive bonds occurred while the Flight 5 nozzles were subjected to subzero temperatures. The results of these tests are documented. Phase 1 testing cooled a full-scale RSRM insulated fixed housing to -13 F, with extensive bondline inspections. Phase 2 testing cooled the witness panel adhesive tensile buttions to -13 F, with failure strengths recorded before, during, and after the cooldown.
The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. In preparation for the Passive Safety Testing program, a series of individual reactivity feedback tests were performed which were designed to simulate and validate specific features and reactivity feedbacks of the FFTF core.
Advanced Stirling Radioisotope Generator (ASRG) is an attractive energy system for select space missions, and with the addition of a VCHP, it becomes even more versatile. The ASRG is powered through thermal energy from decaying radioisotopes acting as General Purpose Heat Sources (GPHS). A Stirling engine converts the thermal energy to electrical energy and cools the GPHS [2]. The Stirling convertor must operate continuously to maintain acceptable temperatures of the GPHS and protect their cladding. The addition of alkali metal VCHP allows the Stirling to cycle on and off during a mission and can be used as a backup cooling system. The benefits of being able to turn the Stirling off are: allowing for a restart of the Stirling and reducing vibrations for sensitive measurements. The VCHP addition should also increase the efficiency of the Stirling by providing a uniform temperature distribution at the heat transfer interface into the heater head.
This report presents the results of an investigation conducted to determine the interrelation of the constituents of the exhaust gases of internal-combustion engines and the effect of engine performance on these relations. Six single-cylinder, liquid-cooled tests engines and one 9-cylinder radial air-cooled engine were tested. Various types of combustion chambers were used and the engines were operated at compression ratios from 5.1 to 7.0 using spark ignition and from 13.5 to 15.6 using compression ignition. The investigation covered a range of engine speeds from 1,500 to 2,100 r.p.m. The fuels used were two grades of aviation gasoline, auto diesel fuel, and laboratory diesel fuel. Power, friction, and fuel-consumption data were obtained from the single-cylinder engines at the same time that the exhaust-gas samples were collected.
NASA Lewis Research Center is presently constructing a test facility for developing turbine-cooling and combustor technology for future-generation aircraft gas-turbine engines. Prototype engine hardware will be investigated in this facility at gas-stream conditions up to 2480 K average turbine inlet temperature and 4.14 million N/sq m turbine inlet pressure. The facility will have the unique features of fully automated control and data acquisition through the use of an integrated system of minicomputers and programmable controllers, which will result in more effective use of operating time and operators and will provide a built-in self-protection safety system. The facility, turbine rig, and turbine-cooling test program are described.
Data were taken with a film-cooled test plate placed in the exhaust stream of a rectangular combustor. Results showed that in a fuel-rich zone, fuel entrained into the film-cooling air would burn at the conditions tested. Test conditions were cooling-gas flow rates, 9.5 and 5 percent of total gas flow; cooling-gas velocities, 23 and 12 m/sec; ambient-temperature cooling gas; hot-gas velocity, nominally 215 m/sec; fuel-air ratio to stoichiometric fuel-air ratio values of 0.1, 0.8, 1.0, 1.2, and 1.35, resulting in hot-gas temperatures from 590 to 2100 K; and atmospheric pressure. Analytical prediction of wall temperatures agreed reasonably well with experimental results.
This internship focused primarily upon software unit testing of Ground Cooling System (GCS) components, one of the three types of tests (unit, integrated, and COTS/regression) utilized in software verification. Unit tests are used to test the software of necessary components before it is implemented into the hardware. A unit test determines that the control data, usage procedures, and operating procedures of a particular component are tested to determine if the program is fit for use. Three different files are used to make and complete an efficient unit test. These files include the following: Model Test file (.mdl), Simulink SystemTest (.test), and autotest (.m). The Model Test file includes the component that is being tested with the appropriate Discrete Physical Interface (DPI) for testing. The Simulink SystemTest is a program used to test all of the requirements of the component. The autotest tests that the component passes Model Advisor and System Testing, and puts the results into proper files. Once unit testing is completed on the GCS components they can then be implemented into the GCS Schematic and the software of the GCS model as a whole can be tested using integrated testing. Unit testing is a critical part of software verification; it allows for the testing of more basic components before a model of higher fidelity is tested, making the process of testing flow in an orderly manner.
The heat-transfer characteristics of a chordwise-finned, impingement-cooled vane were investigated in both a modified J-57 research engine and a four-vane cascade. The data were compared by a correlation of temperature difference ratio with coolant- to gas-flow ratio and also by two modifications of this correlation. The results indicated that the cascade vane temperature data can generally be used to represent the engine vane temperature data. A discussion of engine and cascade gas-side heat-transfer coefficients is also presented. A redesign of the vane leading edge could significantly increase the potential turbine-inlet temperature operating limit.
With the forecasted increase in the construction and operation of nuclear reactors, there will be a corresponding increase in the quantity of spent nuclear fuel (SNF) that requires long-term storage. In SNF, transuranic isotopes contribute the most to the long-term radiotoxicity of the fuel and pose a proliferation risk. One option that has been explored to address these issues is the removal of the transuranic isotopes from SNF and the conversion of these isotopes into transuranic fuel (TRU fuel). Here, this work sought to determine how effective a micro-modular Pebble-Bed High-Temperature Gas-Cooled Reactor (PB-HTGR); the 10-MW High Temperature Gas-cooled Test Reactor (HTR-10); and a salt-cooled small-modular pebble-bed reactor (PBR), i.e. the generic Fluoride-cooled High-temperature Reactor (gFHR), are at reducing the inventory of transuranic isotopes while still maintaining the intrinsic safety features of the PBR designs, such as negative temperature coefficients of reactivity. Optimized pebble designs utilizing TRU fuel were found for both reactors through the adjustment for the packing fraction of fuel in each pebble. The Axial Zone Equilibrium Modeling (A-ZEM) method was used in this work to help select the optimized pebble design. Once an optimized pebble design was selected and an equilibrium model was produced, the results from the deep burn (DB) HTR-10 and gFHR designs were compared to the results of two models from the literature. While both the DB gFHR and the DB HTR-10 were able to reduce the weapons-usable transuranic inventory, the performance of these reactors did not match that of the small-modular PB-HTGRs in the literature. Therefore, a need was identified for further refinement of the gFHR design using TRU fuel, as the results for this model were more promising than those of the DB HTR-10, which was strongly limited by the high leakage intrinsic to micro-modular PB-HTGRs.
A description of the facility and turbine test rig is presented. Also discussed is the turbine cooling test program.