Engineering PapersSearch

SEARCH · Engineering Papers

Results for “COOLING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.

Next-Generation Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.

Analysis of cooling systems for hypersonic aircraft

A computer program has been written to analyze cooling systems of hypersonic aircraft. This computer program called NASP/SINDA is written into the SINDA'85 command structure and uses the SINDA'85 finite difference subroutines. Both internal fluid flow and heat transfer must be analyzed, because increased heating causes a decrease in the flow of the coolant. Also local hot spots will cause a redistribution of the coolant in the system. Both steady state and transient analyses have been performed. Details of empirical correlations are presented. Results for two cooling system applications are given.

Petley, Dennis H.

Thermal Design and Analysis of a Multi-Stage 30K Radiative Cooling System for EPIC

The Experimental Probe of Inflationary Cosmology (EPIC) is an implementation of the NASA Einstein Inflation Probe mission, to answer questions about the physics of Inflation in the early Universe by measuring the polarization of the Cosmic Microwave Background (CMB). The mission relies on a passive cooling system to cool the enclosure of a telescope to 30 K; a cryocooler then cools this enclosure to 18 K and the telescope to 4 K. Subsequently, an adiabatic demagnetization refrigerator further cools a large focal plane to approx.100 mK. For this mission, the telescope has an aperture of 1.4 m, and the spacecraft's symmetry axis is oriented approx. 45 degrees relative to the direction of the sun. The spacecraft will be spun at approx. 0.5 rpm around this axis, which then precesses on the sky at 1 rph. The passive system must both supply the necessary cooling power for the cryocooler and meet demanding temperature stability requirements. We describe the thermal design of a passive cooling system consisting of four V-groove radiators for shielding of solar radiation and cooling the telescope to 30 K. The design realizes loads of 20 and 68 mW at the 4 K and 18 K stages on the cooler, respectively. A lower cost option for reaching 40 K with three V-groove radiators is also described. The analysis includes radiation coupling between stages of the radiators and sunshields, and parasitic conduction in the bipod support, harnesses, and ADR leads. Dynamic effects are also estimated, including the very small variations in temperature due to the scan motion of the spacecraft.

Space

Venus Surface Power and Cooling System Design

A radioisotope power and cooling system is designed to provide electrical power for the a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors simply cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep certain components at a temperature below ambient. The fundamental cooling requirements are comprised of the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus. Assuming 5 cm radial thickness of ceramic blanket insulation, the ambient heat load was estimated at approximately 77 watts. With an estimated quantity of 10 watts of heat generation from electronics and sensors, and to accommodate some level of uncertainty, the total heat load requirement was rounded up to an even 100 watts. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. The maximum theoretically obtainable efficiency is 47.52 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500 watt power class, laboratory-tested Stirling engines at GRC. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg.

Landis, Geoffrey A.

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING

Preliminary design package for prototype solar heating and cooling systems

A summary is given of the preliminary analysis and design activity on solar heating and cooling systems. The analysis was made without site specific data other than weather; therefore, the results indicate performance expected under these special conditions. Major items include a market analysis, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. Two heating and six heating and cooling units will be delivered for Single Family Residences, Multiple-family Residences and commercial applications.

Source record

Internal convective cooling systems for hypersonic aircraft

Parametric studies were conducted to investigate the relative merits of construction materials, coolants, and cooled panel concepts for internal convective cooling systems applied to airframe structures of hydrogen-fueled hypersonic aircraft. These parametric studies were then used as a means of comparing various cooled structural arrangements for a hypersonic transport and a hypersonic research airplane. The cooled airplane studies emphasized weight aspects as related to the choice of materials, structural arrangements, structural temperatures, and matching of the cooling system heat load to the available hydrogen fuel-flow heat sink. Consideration was given to reliability and to fatigue and fracture aspects, as well. Even when auxiliary thermal protection system items such as heat shielding, insulation, and excess hydrogen for cooling are considered the more attractive actively cooled airframe concepts indicated potential payload increases of from 40 percent to over 100 percent for the hypersonic transport as compared to the results of previous studies of the same vehicle configuration with an uncooled airframe.

Anthony, F. M.

Cooling system and insulation concept for a Mach 5 turbo-ramjet aircraft

A cooling system and insulation concept for a Mach 5 cruise aircraft, using non-cryogenic fuel is presented. Catalytic endothermic reaction of petroleum fuel is used as the heat sink for engine cooling. A secondary closed-loop coolant circuit removes heat from the engine and transfers this heat to the catalytic reactor. Insulation on the engine flow path surfaces reduces the cooling requirements. A high temperature insulation system, which is capable of a surface temperature of 4,000 F, is used for the combustor and nozzle. A complete closed-loop cooling system design is shown in detail. Main features of this system include a fuel preheater, a catalytic fuel reactor, and engine wall cooling panels. A silicone-based liquid polymer, designed for extended use at 750 F, is used as the coolant. The preheater and reactor design are based on the results of recent experimental work. The cooling panels are designed using a thermal fluid analysis computer program, which was originally developed for the National Aero-Space Plane (NASP). Major components are analyzed structurally as well as thermally and weights are presented.

Jones, S. C.

Cooling Panel Optimization for the Active Cooling System of a Hypersonic Aircraft

Optimization of cooling panels for an active cooling system of a hypersonic aircraft is explored. The flow passages are of rectangular cross section with one wall heated. An analytical fin-type model for incompressible flow in smooth-wall rectangular ducts with coupled wall conduction is proposed. Based on this model, the a flow rate of coolant to each design minimum mass flow rate or coolant for a single cooling panel is obtained by satisfying hydrodynamic, thermal, and Mach number constraints. Also, the sensitivity of the optimal mass flow rate of coolant to each design variable is investigated. In addition, numerical solutions for constant property flow in rectangular ducts, with one side rib-roughened and coupled wall conduction, are obtained using a k-epsilon and wall function turbulence model, these results are compared with predictions of the analytical model.

Youn, B.

Effects of cooling system parameters on heat transfer in PAFC stack

Analytical and experimental study for the effects of cooling system parameters on the heat transfer and temperature distribution in the electrode plates of a phosphoric acid fuel-cell has been conducted. An experimental set-up that simulates the operating conditions prevailing in a phosphoric-acid fuel-cell stack was designed and constructed. The set-up was then used to measure the overall heat transfer coefficient, the thermal contact resistance, and the electrode temperature distribution for two different cooling plate configurations. Two types of cooling plate configurations, serpentine and straight, were tested. Air, water, and oil were used as coolants. Measurements for the heat transfer coefficient and the thermal contact resistance were made for various flow rates ranging from 16 to 88 Kg/hr, and stack clamping pressure ranging from O to 3448 Kpa. The experimental results for the overall heat transfer coefficient were utilized to derive mathematical relations for the overall heat transfer coefficient as a function of stack clamping pressure and Reynolds number for the three coolants. The empirically derived formulas were incorporated in a previously developed computer program to predict electrodes temperature distribution and the performance of the stack cooling system. The results obtained were then compared with those available in the literature. The comparison showed maximum deviation of +/- 11%.

Abdul-Aziz, Ali A.

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

High Temperature Gas Reactor (HTGR) designs incorporate passive safety systems (e.g., the Reactor Cavity Cooling System [RCCS]) that utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. The industry community is experiencing a pressing need for advanced simulation tools that can accurately assess the performance of these types of systems. In the literature, a knowledge gap exists concerning high-fidelity data for the RCCS, and this gap is one of the areas of focus of the present study. This research focuses on a specific RCCS designed for General Atomics' Modular High-Temperature Gas Reactor (GA-MHTGR). Experimental studies on a scaled version (can be seen in Figure 1) of the air-cooled RCCS used in GA-MHTGR were conducted by the University of Wisconsin-Madison (UW-Madison). This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands

The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

Harber, H.

A spacecraft cooling system for a charged coupled device

This paper describes the thermal analysis, design, and testing of a dedicated cooling system for a Spartan spacecraft payload. A simple reliable design that requires minimum power consumption and minimum weight was developed. The payload has a CCD detector that must be maintained at a temperature of approximately -40 C or colder. The cooling system consists of a fin radiator, dual redundant heat pipes, and a thermal electric device (TED). The system was analytically modeled through the use of the Simplified Shuttle Payload Thermal Analyzer (SSPTA) computer program. A thermal test of the system simulating flight conditions was conducted to correlate the computer model and verify performance specifications.

Walker, Mary S.