Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTROLLED AREAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting Masquerade Attacks in Controller Area Networks Using Graph Machine Learning

Modern vehicles rely on a myriad of electronic control units (ECUs) interconnected via controller area networks (CANs) for critical operations. Despite their ubiquitous use and reliability, CANs are susceptible to sophisticated cyberattacks, particularly masquerade attacks, which inject false data that mimic legitimate messages at the expected frequency. These attacks pose severe risks such as unintended acceleration, brake deactivation, and rogue steering. Traditional intrusion detection systems (IDS) often struggle to detect these subtle intrusions due to their seamless integration into normal traffic. This paper introduces a novel framework for detecting masquerade attacks in the CAN bus using graph machine learning (ML). We hypothesize that the integration of shallow graph embeddings with time series features derived from CAN frames enhances the detection of masquerade attacks. We show that by representing CAN bus frames as message sequence graphs (MSGs) and enriching each node with contextual statistical attributes from time series, we can enhance detection capabilities across various attack patterns compared to using graph-based features only. Our method ensures a comprehensive and dynamic analysis of CAN frame interactions, improving robustness and efficiency. Extensive experiments on the ROAD dataset validate the effectiveness of our approach, demonstrating statistically significant improvements in the detection rates of masquerade attacks compared to a baseline that uses graph-based features only as confirmed by Mann-Whitney U and Kolmogorov-Smirnov tests (p < 0.05) .

Marfo, William [Univ. of Texas, El Paso, TX (Unite↗

Controller area network decoder (CAN-D)

A system and method for decoding an unknown automotive controller area network (“CAN”) message definitions. CAN data vehicle signal mappings are typically held in secret and varied by automotive model and year. Without knowledge of the mappings, the wealth of real-time vehicle data hidden in the automotive CAN packets is uninterpretable—impeding research, after-market tuning, efficiency and performance monitoring, fault diagnosis, and privacy-related technologies. This technology can ascertain the CAN signals' boundaries (start bit and length), endianness (byte ordering), signedness (binary-to-integer encoding) from raw CAN data. This allows conversion of CAN data to time series. Interpreting the translated CAN data's physical meaning and finding a linear mapping to standard units (e.g., knowing the signal is speed and scaling values to represent units of miles per hour) can be achieved for many signals by leveraging diagnostic standards to obtain real-time measurements of in-vehicle systems. The system and method can be integrated into lightweight hardware enabling an OBD-II plugin for real-time in-vehicle CAN decoding or run on standard computers. The system can output a standard DBC file with the signal definition information.

Verma, Kiren E.↗

Low Probability Tail Event Analysis and Mitigation in BPA Control Area: Task 2 Report

Task report detailing low probability tail event analysis and mitigation in BPA control area. Tail event refers to the situation in a power system when unfavorable forecast errors of load and wind are superposed onto fast load and wind ramps, or non-wind generators falling short of scheduled output, causing the imbalance between generation and load to become very significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CANShield: Signal-based Intrusion Detection for Controller Area Networks

Modern vehicles rely on complex cyber-physical systems made up of hundreds of electronic control units (ECUs) connected through controller area network (CAN) buses. However, the CAN bus attack surface is increasing due to advanced features in automobiles, making it prone to injection attacks. The ordinary injection attacks disrupt the typical timing properties of the CAN data stream, and the rule-based intrusion detection systems (IDS) can easily detect them. However, advanced attackers can inject false data to the signal level, maintaining the regular pattern/frequency of the CAN messages. Such attacks can bypass the rule-based IDS or any anomaly-based IDS built on binary payload data. To make the vehicles robust against such intelligent attacks, we propose CANShield, a signal-based intrusion detection framework for the CAN bus that consists of three modules. A data preprocessing module handles the high-dimensional CAN data stream at the signal level and make them suitable for any machine learning model. A data analyzer module consists of multiple deep autoencoder networks, each analyzing the time series data from a different perspective. Finally, an attack detection module uses an ensemble method to make the final decision. Evaluation results on a standard signal-based dataset show the effectiveness of the CANShield in detecting five advanced attacks.

Shahriar, Md Hasan↗

Distributed MPC for Efficient Coordination of Storage and Renewable Energy Sources Across Control Areas

In electric power systems, multiple entities are responsible for ensuring an economic and reliable way of delivering power from producers to consumers. With the increase of variable renewable generation it is becoming increasingly important to take advantage of the individual entities' (and their areas') capabilities for balancing variability. Hence, in this paper, we employ and extend the approximate Newton directions method to optimally coordinate control areas leveraging storage available in one area to balance variable resources in another area with only minimal information exchange among the areas. The problem to be decomposed is a model predictive control problem including generation constraints, energy storage constraints, and AC power flow constraints. Singularity issues encountered when formulating the respective Newton-Raphson steps due to intertemporal constraints are addressed and extensions to the original decomposition method are proposed to improve the convergence rate and required communication of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Controller Area Network for Power Converter Network Monitoring and Control

This presentation explores the adaptation and implementation of CAN bus technology in a network of power converters, emphasizing its potential beyond automotive applications. In this system, multiple power converters can utilize the CAN bus to transmit diverse data types, each assigned specific message and node IDs. A central controller continuously monitors the status of each converter, ensuring efficient management and coordination of power distribution. Additionally, an individual CAN node is

Montoya, Armando Yassir↗

F100 exhaust nozzle area control

The details of the F100 nozzle mechanism design are highlighted, placing particular emphasis upon the evolution of design constraints or drivers from initial concept through current operational deployment. A kinematic description of the area control mechanism is given, and several environmental constraints which complicate the normal mechanism design process are discussed.

Kozlin, J. R.↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fusing Edge Computing with Transport Security by Leveraging the Controller Area Network Transport Security Tracking and Reporting (C-STAR) Unit

Rapid advances in embedded system complexity and capability provides exciting opportunities for transportation security deployment. Manufacturers and developers of these embedded systems continue to provide lower cost and more powerful solutions that can be leveraged by researchers and engineers. Furthermore, deploying these devices at the “edge” of the Internet-of-Things (IoT) infrastructure provides opportunities for highly capable applications in transport security. In an edge computation architecture, the device is co-located at the source of the data in the larger IoT structure – this provides computational capability at the location directly where the data is collected. For shipment transport security, this provides a direct compute node for digestion of data and mitigation actions in real-time. In our application, the vehicle provides a significant amount of this data that can be processed in real-time via the Controller Area Network Transport Security Tracking and Reporting (C-STAR) edge device. Utilization of a computational node located on the vehicle, such as the C-STAR, capitalizes on previously discussed opportunities of edge architectures. In this paper, we will discuss this security solution’s usability, current deployments, and scalability to further applications in transport security. First, we will cover the supported vehicle platforms that can leverage the C-STAR technology. This will be particularly relevant to medium- and heavy-duty vehicles transporting high-risk shipments. Second, we will speak to current deployments of the C-STAR that are ongoing. Finally, we will discuss additional areas for expansion such as maturing the onboard algorithms through continuing collaborations.

Cook, Adian [ORNL] (ORCID:0000000160825395)↗

Criticality Safety Evaluation for 700 and 350 Gram Moderated Fissionable Equivalent (MFE) Criticality Control Areas (CCAs)

This evaluation is intended to generically apply to facilities and/or areas designated as CCAs that store and/or handle greater than 15 grams of fissionable material but no more than 700 grams of MFE. This evaluation includes facilities and/or areas designated as CCAs limited to no more than 350 grams of MFE. Activities performed in these CCAs may include general laboratory activities to include work in radiological areas, chemical procurement, material handling, sampling, imaging, non-destructive analysis, and disposing of nuclear and radiological materials. Materials included in these activities may include radioactive-contaminated oil, polychlorinated biphenyls (PCBs), and/or equipment. Fissionable materials may consist of transuranic (TRU) waste, sources containing fissionable material, uranium in various forms such as metal, oxide and silicide, however other forms of uranium and plutonium may be present. Fissionable materials may consist of fines from cutting, be solid forms mounted on a ring and embedded in epoxy or be in small volumes of dilute solutions resulting from cleaning or other processes. Major equipment located in these CCAs may include inert gas environment gloveboxes, fume hoods, ultrasonic testing equipment, hot presses, rolling mills, furnaces, gamma irradiators, autoclaves, machining equipment, tensile testing equipment, shears, forklifts and cranes.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental Comparison of Speed : Fuel-flow and Speed-area Controls on a Turbojet Engine for Small Step Disturbances

Optimum proportional-plus-integral control settings for speed - fuel-flow control, determined by minimization of integral criteria, correlated well with analytically predicted optimum settings. Engine response data are given for a range of control settings around the optimum. An inherent nonlinearity in the speed-area loop necessitated the use of nonlinear controls. Response data for two such nonlinear control schemes are presented.

ENGINES, CONTROL - TURBOJET↗

Turbine airfoil with controlled area cooling arrangement

A gas turbine airfoil includes a serpentine cooling path with a plurality of channels fluidly interconnected by a plurality of turns for cooling the airfoil wall material. A splitter component is positioned within at least one of the channels to bifurcate the channel into a pressure-side channel passing in between the outer wall and the inner wall of the pressure side and a suction-side channel passing in between the outer wall and the inner wall of the suction side longitudinally downstream of an intermediate height. The cross-sectional area of the pressure-side channel and suction-side channel are thereby controlled in spite of an increasing cross-sectional area of the airfoil along its longitudinal length, ensuring a sufficiently high mach number to provide a desired degree of cooling throughout the entire length of the airfoil.

42 ENGINEERING↗

Cyber‐physical system testbed for power system monitoring and wide‐area control verification

The electric power system is intrinsically a cyber‐physical system (CPS) with power flowing inthe physical system and information flowing in the cyber‐network. Testbeds arecrucial for understanding the cyber‐physical interactions and provideenvironments for prototyping novel applications. This study proposes afour‐layer architecture for CPS testbeds with emphases on communication networkemulation and networked physical components. A configurable software‐definednetwork is employed to bridge physical components with wide‐area applicationsfor closed‐loop control. In order to distribute physically coupled devices intomultiple software simulations, this study proposes a data broker setup based ona distributed messaging environment to achieve low‐latency data streaming. Thedecoupled design with data streaming allows for building testbed components asmodules and running them in a distributed manner. Case studies verify the databroker setup for low‐latency sensing and actuation, as well as the communicationemulation setup for the desired network latency. Also illustrated is a replayattack scenario using synchrophasors in the Western Electricity CoordinatingCouncil (WECC) 181‐bus system for demonstrating the closed‐loop cyber‐physicalsimulation capability of the testbed.

Cui, Hantao↗

A Framework for Probabilistic Evaluation of Interval Management Tolerance in the Terminal Radar Control Area

Projections of future traffic in the national airspace show that most of the hub airports and their attendant airspace will need to undergo significant redevelopment and redesign in order to accommodate any significant increase in traffic volume. Even though closely spaced parallel approaches increase throughput into a given airport, controller workload in oversubscribed metroplexes is further taxed by these approaches that require stringent monitoring in a saturated environment. The interval management (IM) concept in the TRACON area is designed to shift some of the operational burden from the control tower to the flight deck, placing the flight crew in charge of implementing the required speed changes to maintain a relative spacing interval. The interval management tolerance is a measure of the allowable deviation from the desired spacing interval for the IM aircraft (and its target aircraft). For this complex task, Formal Methods can help to ensure better design and system implementation. In this paper, we propose a probabilistic framework to quantify the uncertainty and performance associated with the major components of the IM tolerance. The analytical basis for this framework may be used to formalize both correctness and probabilistic system safety claims in a modular fashion at the algorithmic level in a way compatible with several Formal Methods tools.

Hercencia-Zapana, Heber↗

Selective image area control of X-ray film exposure density

A system for accurately determining the exposure density required for X-ray photography of a particular area of interest is provided. The light received from an X-ray image intensifier is applied to a beam splitting mirror which divides the light between a motion picture film camera and a television film camera. Between the beam splitter and the motion picture film camera, there is positioned another light beam splitter to direct some of the light at a mask having an opening which encloses only the image area of interest. Behind that opening there is positioned a photomultiplier intensity sensor for determining the exposure required and varying X-ray beam intensity accordingly.

Berdahl, C. M.↗