Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTERIZED TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The skeletal structure of insulin-like growth factor I-deficient mice

The importance of insulin-like growth factor I (IGF-I) for growth is well established. However, the lack of IGF-I on the skeleton has not been examined thoroughly. Therefore, we analyzed the structural properties of bone from mice rendered IGF-I deficient by homologous recombination (knockout [k/o]) using histomorphometry, peripheral quantitative computerized tomography (pQCT), and microcomputerized tomography (muCT). The k/o mice were 24% the size of their wild-type littermates at the time of study (4 months). The k/o tibias were 28% and L1 vertebrae were 26% the size of wild-type bones. Bone formation rates (BFR) of k/o tibias were 27% that of the wild-type littermates. The k/o bones responded normally to growth hormone (GH; 1.7-fold increase) and supranormally to IGF-I (5.2-fold increase) with respect to BFR. Cortical thickness of the proximal tibia was reduced 17% in the k/o mouse. However, trabecular bone volume (bone volume/total volume [BV/TV]) was increased 23% (male mice) and 88% (female mice) in the k/o mice compared with wild-type controls as a result of increased connectivity, increased number, and decreased spacing of the trabeculae. These changes were either less or not found in L1. Thus, lack of IGF-I leads to the development of a bone structure, which, although smaller, appears more compact.

NASA Discipline Musculoskeletal↗

Synaptic changes in rat maculae in space and medical imaging: the link

Two different space life sciences missions (SLS-1 and SLS-2) have demonstrated that the synapses of the hair cells of rat vestibular maculae increase significantly in microgravity. The results also indicate that macular synapses are sensitive to stress. These findings argue that vestibular maculae exhibit neuroplasticity to macroenvironmental and microenvironmental changes. This capability should be clinically relevant to rehabilitative training and/or pharmacological treatments for vestibular disease. The results of this ultrastructural research also demonstrated that type I and type II hair cells are integrated into the same neuronal circuitry. The findings were the basis for development of three-dimensional reconstruction software to learn details of macular wiring. This software, produced for scientific research, has now been adapted to reconstruct the face and skull directly from computerized tomography scans. In collaboration with craniofacial reconstructive surgeons at Stanford University Medical Center, an effort is under way to produce a virtual environment workbench for complex craniofacial surgery. When completed, the workbench will help surgeons train for and simulate surgery. The methods are patient specific. This research illustrates the value of basic research in leading to unanticipated medical applications.

Flight Experiment↗

Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent testing of meteorite and Apollo samples on micro-XRF instruments has shown that they can easily detect small zircons and phosphates (approx. 10 m), distinguish different clast lithologies within breccias, and identify different lithologies within small rock fragments (2-4 mm soil Apollo soil fragments).

Zeigler, R. A.↗

Strain Measurements of Chondrules and Refraction Inclusion in Allende

This study uses traditional strain measurement techniques, combined with X-ray computerized tomography (CT), to evaluate petrographic evidence in the Allende CV3 chondrite for preferred orientation and to measure strain in three dimensions. The existence of petrofabrics and lineations was first observed in carbonaceous meteorites in the 1960's. Yet, fifty years later only a few studies have reported that meteorites record such features. Impacts are often cited as the mechanism for this feature, although plastic deformation from overburden and nebular imbrication have also been proposed. Previous work conducted on the Leoville CV3 and the Parnallee LL3 chondrites, exhibited a minimum uniaxial shortening of 33% and 21%, respectively. Petrofabrics in Allende CV3 have been looked at before; previous workers using Electron Back Scatter Diffraction (EBSD) found a major-axis alignment of olivine inside dark inclusions and an "augen"-like preferred orientation of olivine grains around more competent chondrules

Tait, Alastair W.↗

Assessing the Effect of Spaceflight on the Propensity for Astronauts to Develop Disk Herniation

BACKGROUND: A previous study [1] reported that the instantaneous risk of developing a Herniated Nucleus Pulposus (HNP) was higher in astronauts who had flown at least one mission, as compared with those in the corps who had not yet flown. However, the study only analyzed time to HNP after the first mission (if any) and did not account for the possible effects of multiple missions. While many HNP's occurred well into astronauts' careers or in some cases years after retirement, the higher incidence of HNPs relatively soon after completion of space missions appears to indicate that spaceflight may lead to an increased risk of HNP. The purpose of this study was to support the Human System Risk Board assessment of back pain, evaluate the risk of injury due to dynamic loads, and update the previous dataset which contained events up to December 31, 2006. METHODS: Data was queried from the electronic medical record and provided by the Lifetime Surveillance of Astronaut Health. The data included all 330 United States astronauts from 1959 through February 2014. Cases were confirmed by Magnetic Resonance Imaging, Computerized Tomography, Myelography, operative findings, or through clinical confirmation with a neurologist or neurosurgeon. In this analysis, astronauts who had an HNP at selection into the corps or had an HNP diagnosis prior to their first flight were excluded. The statistical challenges in using the available data to separate effects of spaceflight from those associated with general astronaut training and lifestyle on propensity to develop HNPs are many. The primary outcome is reported date of first HNP (if any), which at best is only an approximation to the actual time of occurrence. To properly analyze this data with a survival analysis model, one must also know the "exposure" time - i.e. how long each astronaut has been at risk for developing an HNP. If an HNP is reported soon after a mission, is it mission caused or general? If the former, exposure time should be counted from the time of landing (assuming the risk of HNP occurring during a mission is zero). If the latter, exposure time should be counted from the time of selection; however we can't directly know which one to use. In our analysis we take both of these possibilities into account with a competing risks model, wherein two distinct stochastic processes are going on: TG = time to HNP (general) and TS = time to HNP (spaceflight). Under this type of model, whichever of these occurs first is what we observe; in other words we don't observe TG or TS, only min(TG, TS). Here, we parameterized the model in terms of separate Weibull hazard functions for each process and estimated all parameters using maximum likelihood. In addition, we allowed for a "cured fraction" - i.e. the possibility that some astronauts may never develop an HNP. RESULTS: Results will include a depiction of the competing hazard functions as well as a probability curve for the relative likelihood that an HNP reported at a given time after a mission is actually mission caused. Other factors, such as dwell time in microgravity and vehicle landing environment will be explored. An overall assessment as to whether spaceflight truly exacerbates HNP risk will be made.

Feiveson, A. H.↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

Interdisciplinary Clinical Target Volume Generation for Cardiac Radioablation: Multicenter Benchmarking for the RAdiosurgery for VENtricular TAchycardia (RAVENTA) Trial

Cardiac radioablation is a novel treatment option for therapy-refractory ventricular tachycardia (VT) ineligible for catheter ablation. Three-dimensional clinical target volume (CTV) definition is a key step, and this complex interdisciplinary procedure includes VT-substrate identification based on electroanatomical mapping (EAM) and its transfer to the planning computed tomography (PCT). Benchmarking of this process is necessary for multicenter clinical studies such as the RAVENTA trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AI-Based Quantification of Planned Radiation Therapy Dose to Cardiac Structures and Coronary Arteries in Patients With Breast Cancer

The purpose of this work is to develop and evaluate an automatic deep learning method for segmentation of cardiac chambers and large arteries, and localization of the 3 main coronary arteries in radiation therapy planning on computed tomography (CT). In addition, a second purpose is to determine the planned radiation therapy dose to cardiac structures for breast cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Bioluminescence Tomography-Guided Conformal Irradiation for Preclinical Radiation Research

Widely used cone beam computed tomography (CBCT)-guided irradiators in preclinical radiation research are limited to localize soft tissue target because of low imaging contrast. Knowledge of target volume is a fundamental need for radiation therapy (RT). Without such information to guide radiation, normal tissue can be overirradiated, introducing experimental uncertainties. This led us to develop high-contrast quantitative bioluminescence tomography (QBLT) for guidance. The use of a 3-dimensional bioluminescence signal, related to cell viability, for preclinical radiation research is one step toward biology-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Risk Survival Measures Estimated From Pre- and Posttreatment Computed Tomography Scans Improves Stratification of Patients With Early-Stage Non-small Cell Lung Cancer Treated With Stereotactic Body Radiation Therapy

To predict overall survival of patients receiving stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (ES-NSCLC), we developed a radiomic model that integrates risk of death estimates and changes based on pre- and posttreatment computed tomography (CT) scans. We hypothesize this innovation will improve our ability to stratify patients into various oncologic outcomes with greater accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic Screening of COVID-19 Disease Based on Chest CT and RT-PCR for Cancer Patients Undergoing Radiation Therapy in a Coronavirus French Hotspot

Patients with cancer are presumed to be more vulnerable to COVID-19. We evaluated a screening strategy combining chest computed tomography (CT) and reverse-transcription polymerase chain reaction (RT-PCR) for patients treated with radiation therapy at our cancer center located in a COVID-19 French hotspot during the first wave of the pandemic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Reversible Plating/Stripping of Porous Zinc Anodes for Multivalent Zinc Batteries

Zinc continues to garner immense interest due to its versatility as an anode material in several configurations utilizing either alkaline or mild-pH electrolytes. Current research on using mild-pH electrolytes has improved the rechargeability aspect of Zn-based batteries since Zn2+ is solely utilized for plating/stripping of Zn. Several studies have incorporated Zn metal foils, yet, dramatic improvements can be achieved by expressing Zn as a porous structure. Herein, we use a quasi-pulsed electrodeposition process to prepare a conformal Zn coating onto 3D porous copper foam. By tuning the electrodeposition parameters, we achieved an optimal Zn coating that undergoes reversible plating/stripping when tested in symmetric Zn cells, which supported a low overpotential of ~60 mV for up to 100 cycles. We further investigated changes in the surface morphology by studying the Zn surface of both foil and 3D structure using scanning electron microscopy and X-ray micro-computed tomography. Both techniques showed that the Zn foil undergoes dramatic alterations at the surface, which results in inhomogeneous deposition of Zn, whereas the 3D form exhibited minimal changes. Lastly, we paired both Zn foil and 3D Zn with vanadium oxide and demonstrated that the porous structure supports high rate capability and high specific capacity.

25 ENERGY STORAGE↗