Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSOR EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydrogen Infrastructure Modeling and Optimization

HyET, established in 2008, is a small business developing electro-chemical hydrogen compressors. HyET’s goals are for a low-cost, efficient, high-pressure compressor ready for market and installation into hydrogen infrastructure stations servicing mobile fuel cell applications. NLR has been working on hydrogen infrastructure research for over a decade and includes electrolyzer production via electrolysis, storage, compression, dispensing, safety, and performance validation. Accelerating technologies into the marketplace is one goal of NLR’s hydrogen research. Therefore, HyET and NLR have teamed up to provide one year of support for HyET’s modeling and small-scale experiments optimization efforts for HyET’s next-generation electro-chemical compressor.

08 HYDROGEN↗

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CEAZ: Accelerating Parallel I/O Via Hardware-Algorithm Co-Designed Adaptive Lossy Compression

As supercomputers continue to grow to exa-scale, the amount of data that needs to be saved or transmitted is exploding. To this end, many previous works have studied using error-bounded lossy compressors to reduce the data size and improve the I/O performance. However, little work has been done for effectively offloading lossy compression onto FPGA-based SmartNICs to reduce the compression overhead. In this paper, we propose a hardware-algorithm co-design of efficient and adaptive lossy compressor for scientific data on FPGAs (called CEAZ) to accelerate parallel I/O. Our contribution is fourfold: (1) We propose an efficient Huffman coding approach that can adaptively update Huffman codewords online based on codewords generated offline (from a variety of representative scientific datasets). (2) We derive a theoretical analysis to support a precise control of compression ratio under an error-bounded compression mode, enabling accurate offline Huffman codewords generation. This also help us create a fixed-ratio compression mode for consistent throughput. (3) We develop an efficient compression pipeline by adopting cuSZ’s dual-quantization algorithm to our hardware use case. (4) We evaluate CEAC on five real-world datasets with both a single FPGA board and 256 nodes from Bridges2 supercomputer. Experiments show that CEAZ outperforms the second-best FPGA-based lossy compressor by 2× of throughput and 9.6× of compression ratio. It also improves MPI_File_write and MPI_Gather throughputs by up to 32.7× and 31.4×, respectively.

Zhang, Chengming↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Energy, Exergy, and Emission Analysis on Industrial Air Compressors

Abstract Air compressors, a key fluid power technology, play an essential role in industrial plants and office buildings, hospitals, and other types of facilities. The efficient use of the air compressor is crucial. By controlling unnecessary inefficiencies, high energy consumption can be reduced. This study aims to provide energy and exergy analysis on air compressors for different industries. Detailed case studies were also analyzed. The case study focuses on the energy and exergy analyses of the compressed air system of foundry industries. The results indicate that applying the six improvement recommendations yields significant amounts of energy and cost savings and significant improvements in the system's overall performance. The payback periods for different recommendations are economically feasible and worthwhile to use. The suggested improvement methods can provide cost savings with a low payback period.

Energy & Fuels↗

A Review of the Research and Development of Brayton Cycle Technology in Nuclear Power Applications with a Focus on Compressor Technology

This study reviews the integration of Brayton Cycle (BC) systems in nuclear power generation, emphasizing their potential to enhance thermal efficiency and operational flexibility over traditional Rankine Cycle (RC) systems. Key working fluids, such as helium (He), supercritical carbon dioxide (sCO 2 ), nitrogen (N 2 ), and air, are evaluated for their performance, efficiency, and compatibility with nuclear systems. He is recognized for its high thermal conductivity and inertness at elevated temperatures, while sCO 2 demonstrates advantages in compactness and efficiency in midrange temperatures. This article also highlights the importance of compressor designs in optimizing BC performance and reviews, available compressor technologies. Axial and centrifugal compressor designs enable efficient gas compression while managing the thermal and mechanical stresses associated with high-pressure operations in nuclear systems. Combined with variable geometry components and advanced materials, these technologies address the challenges posed by varying load conditions. Despite the promising features of BC systems, several challenges persist, including high leakage rates and material degradation under extreme conditions, which necessitate robust sealing technologies and thorough testing. The insights gained from operational experiences at facilities, such as the Oberhausen II plant and the High-Temperature He Test Facility (HHV), underscore the complexities involved in designing high-temperature gas turbines for nuclear applications. This review concludes that as the nuclear industry evolves, BC systems hold significant promise for contributing to a sustainable energy future, particularly in the context of small modular reactors (SMRs) and microreactors. Further exploration of combined cycle configurations that combine BCs with RCs may enhance overall efficiency and flexibility in power generation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

OPEN2018 (continuation of GENSETS effort)

This project has demonstrated the key components and engineering principles to support a residential scale (1 to 2 kWe) recuperated Brayton cycle generator based upon a screw compressor and screw expander. This technical work is a continuation of the previously awarded ‘GENSETS’ program. The product goal has been to achieve a 40% fuel-to-electric LHV efficiency, an 80% overall CHP efficiency, emissions qualified to the California Air Resources Board standards, and at noise levels of 55 dB or less at 1 meter. Further, the product must operate with 8,000 hour service intervals and achieve a mean-time to overhaul of 90,000 hours. Lastly, and possibly most importantly, the product must meet demanding cost targets, exhibiting a factory cost well below $1,500/kWe. After extensive aerodynamic studies under the ‘GENSETS’ program, Brayton concluded that miniature turbomachinery could not achieve an efficiency consistent with the product’s system performance goal. Given compressor and turbine efficiency targets in the range of 78 to 81%, Brayton turned to the rotary screw machines. While the justification for a screw compressor over a conventional centrifugal compressor is well supported by industry experience, the high temperature expander represented the core technology advancement. To meet the extremely high efficiency goals, an all-ceramic rotary screw expander hot section was developed and has now been tested in the laboratory. This first-of-its-kind ceramic screw expander prototype was able to demonstrate aerodynamic efficiency in line with predictions. The test article was successfully run to full stress conditions so has also validated the mechanical design of such a unit. This has opened new avenues for the commercialization of high efficiency, small scale power generation. Interest in the technology has sparked several requests for alternate uses, an invitation to present at a screw machine conference, and continued interest from parties looking to develop a product in the spirit of the original ‘GENSETS’ goals.

42 ENGINEERING↗

SnowPac : a multiscale cubic B-spline wavelet compressor for astronomical images

ABSTRACT As more advanced and complex survey telescopes are developed, the size and scale of data being captured grows at increasing rates. Across various domains, data compression through wavelets has enabled the reduction of data size and increase in computation efficiency. In this paper, we provide qualitative and quantitative tests of a new wavelet-based image compression method compared against the current standard for astronomical images. The analysis is improved by making use of state-of-the-art object detection systems to accurately measure the impact of the compression. We find that a combination of lossy wavelet-based methods, efficient quantization, and lossless dictionary compressors can preserve up to 98 per cent of astronomical objects at a 10:1 compression ratio. This significant reduction in file size also preserves astronomical object properties better than existing methods. These methods help further reduce future workloads for image-heavy processing pipelines.

Pulido, Jesus↗

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

cuZ-Checker: A GPU-Based Ultra-Fast Assessment System for Lossy Compressions

Lossy compression is becoming an indispensable technique for the success of today's extreme-scale high-performance computing projects that produce vast volumes of data during scientific simulations or instrument data acquisitions. Comprehensively understanding the compression quality and performance of different lossy compressors is critical to selecting the best-fit compressors and using them properly and efficiently in practice. A few lossy compression assessment tools (e.g., Z-checker) have been developed, but none of them support the execution in a GPU environment. This is a significant gap because many recent extreme-scale applications and lossy compressors (e.g., cuSZ) can run entirely within GPUs. In this work, we develop an efficient lossy compression measuring system (called cuZ-Checker) on the GPU platform, which aims to perform the lossy compression quality and performance assessment completely within the GPU environment. Our contribution is threefold. (1) We develop a novel GPU-based lossy compression measuring framework using a computation pattern-based design approach. This approach classifies the computing-intensive metrics into three categories based on their patterns which creates large opportunities for kernel fusion and data reuse. (2) For each pattern in cuZ-Checker, we develop a CUDA kernel and provide fine-grained optimizations to boost its performance. (3) We thoroughly evaluate our cuZ-checker on a V100 GPU using four real-world scientific application datasets. Experiments show that cuZ-Checker can significantly accelerate the overall lossy compression assessment performance by 23X similar to 31X compared with the OpenMP-based multithreading CPU performance. To the best of our knowledge, this is the first lossy compression measuring system designed for GPU devices.

GPU↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗