Mechanisms of Comp-B Thermal Explosions
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided.
Collection of FORTRAN90 routines for software development in finite element analysis using linear nodal and edge basis functions on a tetrahedral mesh. Routines for mesh I/O; mesh quality testing; element-wise mass and stiffness matrix computation, solution I/O; preconditioned iterative linear solvers (QMR, BiCGSTAB and CG) utilizing the matrix-free approach in Weiss (SEG, 2001).
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Highlights: • Autoantibodies against the TSP-4, COMP and CLEC3A are present in serum of osteoarthritis (OA) patients. • The detection of autoantibodies against TSP-4, COMP and CLEC3A may support the clinical diagnosis of OA. • OA with autoantibodies against cartilage extracellular matrix proteins defines a new OA subgroup. • Patients with high concentrations of autoantibodies may benefit from an immune suppressive therapy. We investigated the presence of autoantibodies against the extracellular matrix proteins thrombospondin-4 (TSP-4), cartilage oligomeric matrix protein (COMP), C-type lectin domain family 3 member A (CLEC3A), collagen II, collagen VI, matrilin-3, and fibrillin-2 in the serum of osteoarthritis (OA) patients. We compared those results with the presence of such antibodies in rheumatoid arthritis (RA) patients and in healthy donors (HD). Our study examines whether antibodies against extracellular proteins can be used as potential biomarkers to support the clinical diagnosis of OA. 10 OA, 10 RA patients and 10 HD were enrolled in this explorative cross-sectional study. SDS-PAGE and immunoblot were used to investigate the presence of antibodies against extracellular matrix proteins. The serum of 5/10 OA patients but 0/10 HD exhibited TSP-4 IgG isotype antibodies (P = 0.033). The serum of 8/10 OA patients but only 1/10 HD exhibited IgG isotype antibodies against TSP-4 or COMP (P = 0.005). The serum of 9/10 OA patients but only 1/10 HD exhibited IgG isotype antibodies against TSP-4, COMP or CLEC3A (P = 0.005). We found strong evidence for the presence of IgG isotype autoantibodies against the cartilage extracellular matrix proteins TSP-4, COMP and CLEC3A in OA. The detection of IgG isotype autoantibodies against TSP-4, COMP and CLEC3A may support the clinical diagnosis of OA. OA with autoantibodies against cartilage extracellular matrix proteins defines a new OA subgroup suggesting that patients with high concentrations of autoantibodies may benefit from an immune suppressive therapy.
The United States (US) Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (SNL). The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water moderated and — reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM 096, LEU- COMP-THERM-097, LEU-COMP-THERM-101, LEU-COMP-THERM-102, and LEU-COMP-THERM-111. Applied interests in neutron-absorbing elements at epithermal and intermediate neutron energy ranges at DOE’s Hanford Site and Savannah River Site were identified through DOE Office of Environmental Management (EM) workshops and needs surveys performed in conjunction with the National Nuclear Security Administration/Nuclear Criticality Safety Program. In response, a team lead by Oak Ridge National Laboratory (ORNL) performed a study evaluating the use of 7uPCX for testing the epithermal cross sections of materials at SNL. This marked the inception of the set of experiments described here. The purpose of these experiments was to measure the effects of tantalum in nearly-critical systems. The tantalum was introduced into the fuel arrays as experiment rods within a central test region. The central test region was designed to target the epithermal neutron energy range by providing a dry cylindrical cavity constructed of aluminum and lined with 0.04 in (0.1016 cm) thick cadmium sheet. The central test region has an outer diameter of 3.75 in (9.525 cm) length of 31 in (78.74 cm) and can hold 85 tantalum rods nominally 0.25 in (0.635 cm) outside diameter and 31.25 in (79.375 cm) long. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 2016 fuel rod positions on a pitch of 0.4 in (1.016 cm) in a series of 21 hexagonal rings positioned around the central test region. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The eight cases in this experiment series were performed in 2024 in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility by varying the number of fuel rods in the critical assembly. The personnel involved in conducting these experiments included David Ames, Elijah Lutz, Beth Hanson, Patrick Ward, Jason Soares, and Augie Chapa from SNL, as well as Mathieu Dupont and B.J. Marshall from ORNL. Case 1 had no tantalum experiment rods. Case 2 had seven tantalum rods in the center of the central test region. Case 3 had 18 tantalum rods in the third hexagonal ring of the central test region. Case 4 had 19 tantalum rods in the center of the central test region. Case 5 had 30 tantalum rods in the outer most positions of the central test region. Case 6 had 37 tantalum rods in the center of the central test region. Case 7 had 61 tantalum rods in the center of the central test region. Case 8 had 85 tantalum rods filling all positions in the central test region. All eight critical experiments are judged to be acceptable as benchmark experiments.
Purpose: Conventional radiotherapy typically aims for homogenous dose in the planning target volume (PTV) while sparing organs at risk (OAR). The authors quantified and characterized the trade-off between PTV dose inhomogeneity (IH) and OAR sparing in complex head and neck volumetric modulated arc therapy plans. Methods: Thirteen simultaneous integrated boost plans were created per patient, for ten patients. PTV boost{sub (B)}/elective{sub (E)} optimization priorities were systematically increased. IH{sub B} and IH{sub E}, defined as (100% − V95%) + V107%, were evaluated against the average of the mean dose to the combined composite swallowing and combined salivary organs (D-OAR{sub comp}). To investigate the influence of OAR size and position with respect to PTV{sub B/E}, OAR dose was evaluated against a modified Euclidean distance (DM{sub B}/DM{sub E}) between OAR and PTV. Results: Although the achievable D-OAR{sub comp} for a given level of PTV IH differed between patients, excellent logarithmic fits described the D-OAR{sub comp}/IH{sub B} and IH{sub E} relationship in all patients (mean R{sup 2} of 0.98 and 0.97, respectively). Allowing an increase in average IH{sub B} and IH{sub E} over a clinically acceptable range, e.g., from 0.4% ± 0.5% to 2.0% ± 2.0% and 6.9% ± 2.8% to 14.8% ± 2.7%, respectively, corresponded to a decrease in average dose to the composite salivary and swallowing structures from 30.3 ± 6.5 to 23.6 ± 4.7 Gy and 32.5 ± 8.3 to 26.8 ± 9.3 Gy. The increase in PTV{sub E} IH was mainly accounted for by an increase in V107, by on average 5.9%, rather than a reduction in V95, which was on average only 2%. A linear correlation was found between the OAR dose to composite swallowing structures and contralateral parotid and submandibular gland, with DM{sub E} (R{sup 2} = 0.83, 0.88, 0.95). Only mean ipsilateral parotid dose correlated with DM{sub B} (R{sup 2} = 0.87). Conclusions: OAR sparing is highly dependent on the permitted PTV{sub B/E} IH. PTV{sub E} IH substantially influences OAR doses. These results are relevant for clinical practice and for future automated treatment-planning strategies.
Purpose: RapidPlan, a commercial knowledge-based planning solution, uses a model library containing the geometry and associated dosimetry of existing plans. This model predicts achievable dosimetry for prospective patients that can be used to guide plan optimization. However, it is unknown how suboptimal model plans (outliers) influence the predictions or resulting plans. We investigated the effect of, first, removing outliers from the model (cleaning it) and subsequently adding deliberate dosimetric outliers. Methods and Materials: Clinical plans from 70 head and neck cancer patients comprised the uncleaned (UC) Model{sub UC}, from which outliers were cleaned (C) to create Model{sub C}. The last 5 to 40 patients of Model{sub C} were replanned with no attempt to spare the salivary glands. These substantial dosimetric outliers were reintroduced to the model in increments of 5, creating Model{sub 5} to Model{sub 40} (Model{sub 5-40}). These models were used to create plans for a 10-patient evaluation group. Plans from Model{sub UC} and Model{sub C}, and Model{sub C} and Model{sub 5-40} were compared on the basis of boost (B) and elective (E) target volume homogeneity indexes (HI{sub B}/HI{sub E}) and mean doses to oral cavity, composite salivary glands (comp{sub sal}) and swallowing (comp{sub swal}) structures. Results: On average, outlier removal (Model{sub C} vs Model{sub UC}) had minimal effects on HI{sub B}/HI{sub E} (0%-0.4%) and sparing of organs at risk (mean dose difference to oral cavity and comp{sub sal}/comp{sub swal} were ≤0.4 Gy). Model{sub 5-10} marginally improved comp{sub sal} sparing, whereas adding a larger number of outliers (Model{sub 20-40}) led to deteriorations in comp{sub sal} up to 3.9 Gy, on average. These increases are modest compared to the 14.9 Gy dose increases in the added outlier plans, due to the placement of optimization objectives below the inferior boundary of the dose-volume histogram-predicted range. Conclusions: Overall, dosimetric outlier removal from or addition of 5 to 10 outliers to a 70-patient model had marginal effects on resulting plan quality. Although the addition of >20 outliers deteriorated plan quality, the effect was modest. In this study, RapidPlan demonstrated robustness for moderate proportions of salivary gland dosimetric outliers.
We report the discovery of a stripped giant + lower giant Algol-type binary, 2M04123153+6738486 (2M0412), identified during a search for non-interacting compact object – star binaries. 2M0412 is an evolved ( T eff, giant ≃ 4000 K), luminous ( L giant ≃ 150 L ⊙ ) red giant in a circular P = 81.2 d binary. 2M0412 is a known variable star previously classified as a semiregular variable. The cross-correlation functions of follow-up Keck/HIRES and LBT/Potsdam Echelle Polarimetric and Spectroscopic Instrument (PEPSI) spectra show an radial velocity variable second component with implied mass ratio q = M giant / M comp ≃ 0.20 ± 0.01. The All-Sky Automated Survey for SuperNovae (ASAS-SN), Asteroid Terrestrial-impact Last Alert System (ATLAS), Transiting Exoplanet Survey Telescope ( TESS ), and Zwicky Transient Facility (ZTF) light curves show that the giant is a Roche lobe filling ellipsoidal variable with an inclination of 49.4 ± 0.3°, and a giant mass of M giant = 0.38 ± 0.01 M ⊙ for a distance of ≃ 3.7 kpc. The mass of the giant indicates that its envelope has been partially stripped. The giant companion on the lower red giant branch has a mass of M comp = 1.91 ± 0.03 M ⊙ with T eff, comp ≃ 5000 K, L comp ≃ 60 L ⊙ , and R comp ≃ 11 R ⊙ . The lower giant contributes ${\sim }35{{\ \rm per\ cent}}$ of the flux in the V band. We also identify an orbital phase dependent, broad $\rm H\,\alpha$ emission line which could indicate ongoing accretion from the stripped red giant on to the companion.
Turbulence is a critical ingredient for star formation, yet its role for the initial mass function (IMF) is not fully understood. Here we perform magnetohydrodynamical (MHD) simulations of star cluster formation including gravity, turbulence, magnetic fields, stellar heating, and outflow feedback to study the influence of the mode of turbulence driving on IMF. We find that simulations that employ purely compressive turbulence driving (COMP) produce a higher fraction of low-mass stars as compared to simulations that use purely solenoidal driving (SOL). The characteristic (median) mass of the sink particle (protostellar) distribution for COMP is shifted to lower masses by a factor of ∼1.5 compared to SOL. Our simulation IMFs capture the important features of the observed IMF form. We find that turbulence-regulated theories of the IMF match our simulation IMFs reasonably well in the high-mass and low-mass range, but underestimate the number of very low-mass stars, which form towards the later stages of our simulations and stop accreting due to dynamical interactions. Our simulations show that for both COMP and SOL, the multiplicity fraction is an increasing function of the primary mass, although the multiplicity fraction in COMP is higher than that of SOL for any primary mass range. We find that binary mass ratio distribution is independent of the turbulence driving mode. The average specific angular momentum of the sink particles in SOL is a factor of 2 higher than that for COMP. Overall, we conclude that the turbulence driving mode plays a significant role in shaping the IMF.
The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.
The Seven Percent Critical Experiment (7uPCX) was designed to provide benchmark criticality and reactor physics data for water-moderated pin-fueled nuclear reactor cores. The enrichment of the fuel was chosen to explore the enrichment range above the current 5% ceiling for US commercial pressurized water reactors. The experiment was part of the US Department of Energy (DOE) Nuclear Energy Research Initiative Project 01-124 titled 'Reactor Physics and Criticality Benchmark Evaluations for Advanced Nuclear Fuel'. Three sets of benchmark experiments have been completed using the 7uPCX and documented as LEUCOMP-THERM-080, LEU-COMP-THERM-078, and LEUCOMP-THERM-096. The experiments for LEUCOMP-THERM-080 and LEU-COMP-THERM-078 were done in fully-reflected arrays with the number of fuel rods in the array as the approach parameter. The experiments for LEU-COMP-THERM-096 are similar to those in LEUCOMP-THERM-080 except that the arrays are partially-reflected - the arrays were larger than would be possible with full reflection and the approach-to-critical experiments were done with the depth of the water in the critical assembly as the approach parameter. The experiments described here are similar to the fully-reflected experiments in LEU-COMP-THERM-080 with some of the central fuel rods in the array replaced by titanium rods, aluminum rods, and/or water. The experiments are designed to provide criticality safety benchmarks with significant reactivity from titanium and equivalent configurations with aluminum experiment rods. These experiments are documented as LEU-COMP-THERM-097. (authors)
The solubility of RDX (hexahydro-1,3,5-tri-nitro-1,3,5-triazine) in TNT (2,4,6-trinitrotoluene) at elevated temperatures is required to accurately predict the response of Comp-B 3 (60:40 RDX:TNT) during accidents involving fire. As the temperature increases, the TNT component melts, the RDX partially dissolves in the liquid TNT, and the remaining RDX melts (203 °C) as the Comp-B thermally ignites. In the current work, we used a differential scanning calorimeter (DSC) to estimate the solubility of RDX in TNT at the melting point of RDX. Most DSC measurements of Comp-B 3 do not show an RDX melt endotherm. The absence of an endotherm associated with the RDX melt has been interpreted as RDX being completely dissolved in TNT before reaching the melting point. Here, we have observed that the endotherm is not absent, but is masked by exothermic reactions occurring at these elevated temperatures. We have inhibited the exothermic reactions by venting our DSC samples and measuring the RDX melt endotherm in our Comp-B 3 samples at about 203 °C. Using the measured heat flow associated with the RDX melt and the latent melting enthalpy of RDX, we have approximated the solubility of RDX in TNT to be roughly 50–100 g RDX per 100 g TNT . The broad range is based on corrections for exothermic reactions occurring as the RDX melts.
Generalized synthetic strategies for nanostructures with well-defined physical dimensions and broad-range chemical compositions are at the frontier of advanced nanomaterials design, functionalization, and application. In this paper, we report a composition-programmable synthesis of multimetallic phosphide CoMP x nanorods (NRs) wherein M can be controlled to be Fe, Ni, Mn, Cu, and their binary combinations. Forming Co 2 P/MP x core/shell NRs and subsequently converting them into CoMP x solid-solution NRs through thermal post-treatment are essential to overcome the obstacle of morphology/structure inconsistency faced in conventional synthesis of CoMP x with the different M compositions. The resultant CoMP x with uniform one-dimensional (1-D) structure provides us a platform to unambiguously screen the M synergistic effects in improving the electrocatalytic activity, as exemplified by the oxygen evolution reaction. This new approach mediated by core/shell nanostructure formation and conversion can be extended to other multicomponent nanocrystal systems (metal alloy, mixed oxide, and chalcogenide, etc.) for diverse applications.
The discovery of ubiquitous low-frequency (3-5 mHz) Alfvenic waves in the solar chromosphere (with Hinode/Solar Optical Telescope) and corona (with CoMP and SDO) has provided some insight into the non-thermal energy content of the outer solar atmosphere. However, many questions remain about the true magnitude of the energy flux carried by these waves. Here we explore the apparent discrepancy in the resolved coronal Alfvenic wave amplitude ({approx}0.5 km s{sup -1}) measured by the Coronal Multi-channel Polarimeter (CoMP) compared to those of the Hinode and the Solar Dynamics Observatory (SDO) near the limb ({approx}20 km s{sup -1}). We use a blend of observational data and a simple forward model of Alfvenic wave propagation to resolve this discrepancy and determine the Alfvenic wave energy content of the corona. Our results indicate that enormous line-of-sight superposition within the coarse spatio-temporal sampling of CoMP hides the strong wave flux observed by Hinode and SDO and leads to the large non-thermal line broadening observed. While this scenario has been assumed in the past, our observations with CoMP of a strong correlation between the non-thermal line broadening with the low-amplitude, low-frequency Alfvenic waves observed in the corona provide the first direct evidence of a wave-related non-thermal line broadening. By reconciling the diverse measurements of Alfvenic waves, we establish large coronal non-thermal line widths as direct signatures of the hidden, or ''dark'', energy content in the corona and provide preliminary constraints on the energy content of the wave motions observed.
The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMPTHERM- 096, LEU-COMP-THERM-097, and LEU-COMP-THERM-101. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The purpose of these experiments was to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by removing fuel rods from fully fueled configurations, effectively increasing the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.