Detection of dynamical transitions in hydrogenous materials using transmission measurements with very cold neutrons

We have tested the transmission of very cold neutrons as a method to measure dynamical transitions in hydrogenous materials. Transmitted intensities vs. temperature at 30 A neutron wavelength were measured for four materials that undergo phase transformations associated with changes in dynamics: ammonium iodide, sodium borohydride, hexamethylbenzene, and dicesium dodecahydro-closo-dodecaborate. In some cases, neutron vibrational spectra above and below the transformation temperatures are compared to the transmission results. The measurements show changes in transmission at or near the transition for all these compounds, reflecting dynamical changes. The results demonstrate that the transmission method is sensitive to motional changes due to a wide range of structural transitions, from first-order to much more subtle order-disorder effects and for both small molecular species and larger molecules. The technique is valuable for rapid (ca. hours) scans of new materials to guide neutron inelastic scattering experiments or to complement the results of other techniques. - Graphical abstract: The transmission of very long wavelength neutrons is a highly sensitive probe of dynamical transitions in hydrogenous materials. Highlights: > Transmission of very long wavelength neutrons can probe dynamical transitions. > The technique is sensitive for both first-order and order-disorder transformations. > Changes in dynamical behavior of small and large molecular species can be detected. > This method can be a valuable guide for complex neutron scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of achromatic cold-neutron microscope utilizing axisymmetric focusing mirrors

An achromatic cold-neutron microscope with magnification 4 is demonstrated. The image-forming optics is composed of nested coaxial mirrors of full figures of revolution, so-called Wolter optics. The spatial resolution, field of view, and depth of focus are measured and found consistent with ray-tracing simulations. Methods of increasing the resolution and magnification are discussed, as well as the scientific case for the neutron microscope. In contrast to traditional pinhole-camera neutron imaging, the resolution of the microscope is determined by the mirrors rather than by the collimation of the beam, leading to possible dramatic improvements in the signal rate and resolution.

43 PARTICLE ACCELERATORS↗

Measurement of cross sections for inelastic cold-neutron scattering in metals and polymers by the method of (n, {gamma}) analysis

The results obtained by measuring the cross sections for the inelastic scattering of very cold neutrons for a number of metals and polymers by the method of a neutron-irradiation analysis are presented. The method is based on simultaneously measuring events of inelastic scattering and neutron capture in the sample under investigation via recording gamma radiation with a semiconductor germanium detector. Neutron capture by a nucleus of the sample is accompanied by the prompt radiation of gamma rays having a known spectrum. Upon inelastic scattering, a neutron acquires thermal energy. Upon leaving the sample, this neutron is absorbed in a special converter that contains the isotope {sup 10}B. The capture of the neutron by a {sup 10}B nucleus is followed by the emission of a 477-keV gamma ray. The probabilities of capture and inelastic scattering are proportional to the respective neutron-interaction cross sections, and the ratio of the recorded detector counts corresponding to events of the two types does not depend on the spectrum of the incident flux of very cold neutrons or on the trajectory of neutron motion in the sample. The sought inelastic-scattering cross section at a fixed sample temperature is calculated by using this ratio and the known cross section for neutron capture by the sample isotope having a known gamma-radiation spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cold Neutron Energy Dependent Production of Ultracold Neutrons in Solid Deuterium

A measurement of the production of ultracold neutrons from velocity-selected cold neutrons on gaseous and solid deuterium targets is reported. The expected energy dependence for two-particle collisions with well defined neutron and Maxwell-Boltzmann distributed molecular velocities is found for the gas target. The solid target data agree in shape with the phonon density-of-states curve and provide strong evidence for the phonon model including multiphonon excitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance tests of boron-coated straw detectors with thermal and cold neutron beams

Prototypes of in-house developed boron-coated straw (BCS) detectors have been tested in the thermal and cold neutron energy ranges. Their neutron detection performance has been benchmarked against the industry standard (detector tubes filled with 3 He gas). The tests show that the BCS detectors perform near their theoretical limit regarding the detection efficiency, which is adequate for scientific instruments in the cold neutron energy range. Finally, the BCS detectors perform on par with 3 He tubes in terms of signal to noise and timing resolution, and superior regarding longitudinal spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Edge localized modes of cold neutrons in periodic condensed media

It is found that for certain energies of discreet cold neutrons, quasi-stationary eigen solutions of the corresponding Schrodinger equation, which are localized in the layer of a periodic medium, exist. The localization time of these solutions is strongly dependent on the layer thickness, being finite for a finite layer thickness and increasing indefinitely upon a infinite growth of the layer thickness as the third power of the layer thickness. The problem has been solved in the two-wave approximation of the dynamic diffraction theory for the neutron propagation direction coinciding with the periodicity axes (normal incidence of the neutron beam on the layer). The expressions for neutron eigenwave functions in a periodic medium, the reflection and transmission coefficients, and the neutron wavefunction in the layer as a function of the neutron energy incident on the layer have been determined. It turns out that for the certain discrete neutron energies, the amplitudes of the neutron wavefunction in the layer reach sharp maxima. The corresponding energies are just outside of the neutron stop band (energies forbidden for neutron propagation in the layer) and determine the energies of neutron edge modes (NEMs) localized in the layer, which are direct analogs of the optical edge modes for photonic crystals. The dispersion equation for the localized neutron edge modes has been obtained and analytically solved for the case of thick layers. A rough estimate for the localization length L is L ~(db N){sup –1}, where b is the neutron scattering length, d is the crystal period, and N is the density of nuclei in the crystal. The estimates of the localized thermal neutron lifetime show that acheaving of a lifetime close to the free neutron lifetime seems nonrealistic due to absorption of thermal neutrons and requires a perfect large size crystal. Nevertheless, acheaving the localized neutron lifetime exceeding by ~10{sup 4} times the neutron time of flight through the layer appears as experimentally attainable. The perspectives of the NEM observation are briefly discussed. It is proposed to use NEM for ultrahigh thermal neutron monochromatization by means of NEM excitation in perfect single crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The crystal acceleration effect for cold neutrons

A new mechanism of neutron acceleration is discussed and studied experimentally in detail for cold neutrons passing through the accelerated perfect crystal with the energies close to the Bragg one. The effect arises due to the following reason. The crystal refraction index (neutron-crystal interaction potential) for neutron in the vicinity of the Bragg resonance sharply depends on the parameter of deviation from the exact Bragg condition, i.e. on the crystal-neutron relative velocity. Therefore the neutrons enter into accelerated crystal with one neutron-crystal interaction potential and exit with the other. Neutron kinetic energy cannot vary inside the crystal due to its homogeneity. So after passage through such a crystal neutrons will be accelerated or decelerated because of the different energy change at the entrance and exit crystal boundaries.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%)CF{sub 4}, at atmospheric pressure, in a stable condition at a gain of around 10{sup 4}. Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene

Ultra-cold neutrons (UCN) from the LANSCE super-thermal deuterium source were used to fill an acrylic bottle coated with deuterated polystyrene. The bottle was constructed to minimize losses through the filling valve. The storage time was extracted from a series of measurements where the number of neutrons was counted after they were held in the bottle for durations varying from 60-1200 s. The data were collected at temperatures of 18, 40, 65, 105, and 295 K. The data has been analyzed in terms of the ratio of the imaginary to real part of the wall potential. The analysis considers the velocity dependence of the probability per bounce of wall loss. The implication of these measurements for the SNS electric dipole moment search will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The decompression of cold neutron star matter

The ejection of cold neutron-star matter is examined, and an attempt is made to determine whether the final composition of this matter may be similar to that normally associated with the hot high-neutron-flux r-process. A semiempirical liquid-drop model is used for the nucleus, and the equilibrium composition of the matter is determined by assuming it to be in its absolute ground state at a given density. Physical mechanisms operating during the expansion are analyzed, and the composition of the ejected matter is found as a function of its density during expansion. The results indicate that it is virtually impossible for deuterium to form, that neutrons can be captured only after beta decay increases the atomic numbers of nuclei, and that no free neutrons can escape. It is concluded that neutron-star ejecta can produce heavy neutron-rich nuclei and may produce somewhat heavier nuclei than a standard r-process.

Lattimer, J. M.↗

Flexible polyvinyl chloride neutron guides for transporting ultracold and very cold neutrons

The transmission of ultracold neutrons (UCNs) through flexible polyvinyl chloride (PVC) tubes with lengths of up to 3 m and an internal diameter of 6-8 mm has been studied. High UCN transmission is found even for arbitrarily bent tubes (single bend, double bend, triple bend, figure eight, etc.). The transmission can be improved significantly by coating the inner surface of the tube with a thin layer of liquid fluorine polymer. The prospects of these neutron guides in fundamental and applied research are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the parity-violating triton emission asymmetry in the reaction {sup 6}Li(n,{alpha}){sup 3}H with polarized cold neutrons

We describe measurements of the parity-violating (P-odd) triton emission asymmetry coefficient a{sub P-odd} in the {sup 6}Li(n,{alpha}){sup 3}H reaction with polarized cold neutrons. Experiments were carried out at the Petersburg Nuclear Physics Institute (Gatchina, Russia) and at the Institut Laue-Langevin (Grenoble, France). We employed an ionisation chamber in a configuration allowing us to suppress the left-right asymmetry well below 10{sup -8}. An additional test for a false asymmetry due to eventual target impurities (''zero test'') resulted in a{sub 0-test}=(0.0{+-}0.5)x10{sup -8}. As final result of this series of experiments we obtained a{sub P-odd}=(-8.8{+-}2.1)x10{sup -8}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Options for a very cold neutron source for the second target station at SNS

Simulation work is underway to identify a very cold neutron source solution that would provide an order of magnitude higher neutron output than the conventional moderator suite. Moderator candidates such as water ice, beryllium, ortho-D2, CH4, and neon all solid at temperatures of 4-6 K were investigated. At present no moderator option was able to achieve the set goal; ortho-D2 and CH4 seem to be the most promising options.

Gallmeier, Franz X.↗

Deuterated polyethylene coatings for ultra-cold neutron applications

We report on the fabrication and use of deuterated polyethylene as a coating material for ultra-cold neutron (UCN) storage and transport. The Fermi potential has been determined to be 214 neV, and the wall loss coefficient η is 1.3 × 10{sup 4} per wall collision. The coating technique allows for a wide range of applications in this field of physics. In particular, flexible and quasi-massless UCN guides with slit-less shutters and seamless UCN storage volumes become possible. These properties enable the use in next-generation measurements of the electric dipole moment of the neutron.

36 MATERIALS SCIENCE↗

The cold neutron chopper spectrometer at the Spallation Neutron Source—A review of the first 8 years of operation

The first eight years of operation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge is being reviewed. The instrument has been part of the facility user program since 2009, and more than 250 individual user experiments have been performed to date. CNCS is an extremely powerful and versatile instrument and offers leading edge performance in terms of beam intensity, energy resolution, and flexibility to trade one for another. In addition, experiments are being routinely performed with the sample at extreme conditions: T ≲ 0.05 K, p ≳ 2 GPa, and B = 8 T can be achieved individually or in combination. In particular, CNCS is in a position to advance the state of the art with inelastic neutron scattering under pressure, and some of the recent accomplishments in this area will be presented in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10 8 n s -1 cm -2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr 3 :(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10 5 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr 3 :(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133 Ba, 60 Co and 152 Eu as well as data from the reactions 27 Al(n,γ) 28 Al and 35 Cl(n,γ) 36 Cl in the energy range from 30 keV up to 10 MeV.

47 OTHER INSTRUMENTATION↗