Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COAXIAL CABLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

A Simple Design Erosional Plasma Gun Made of a Coaxial Cable with Polyethylene Insulation

Abstract—: A compact pulsed plasma generator of simple design made of a coaxial cable with polyethylene insulation has been described. A plasma gun generates a cloud of carbon-hydrogen plasma with an electron density of more than 10{sup 13} cm{sup –3}, including in a magnetic field produced of up to 500 G and also in the presence of the background plasma with a density of about 10{sup 12} cm{sup –3}, which is produced by an independent source. The high resource of the gun and stability of plasma parameters from one pulse to another allows using such a gun in laboratory experiments simulating dynamic processes in space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

We report a metal-ceramic coaxial cable Fabry-Pérot interferometer (MCCC-FPI) has been developed as a new microwave sensor and demonstrated for fast and reliably measuring and continuously monitoring dielectric constants for pure and mixed liquids. The sensor only requires a simple reference scan of the interferogram for the FPI with its sensing chamber filled with air or under vacuum to determine the actual inter-reflector length. The sensor is validated by measuring room temperature dielectric constant (εr) at high frequencies around 1.4–4.7 GHz for three vegetable oils (corn, sesame, and olive), the synthetic Mobil ® -1 engine oil, and mixtures containing sesame oil and water. The sensor has been also successfully demonstrated for determining εr values for the Mobil-1 oil at various temperatures and for the well-dispersed sesame oil-water mixtures of different compositions. The Bottcher’s model of effective medium theory is shown to be better suited for predicting the ε r of the sesame oil-water mixture than the Maxwell-Garnett and Bruggeman equations of spherical solutions.

47 OTHER INSTRUMENTATION↗

Corrugated Coaxial Cable Modeling with a Nodal Discontinuous Galerkin (nDG) Method

Due to the lack of well-developed time domain models for a corrugated coaxial cable, the cable was modeled by numerically solving axially symmetric Maxwell’s equations in the dielectric. Although there have already been many implementations of a nodal Discontinuous Galerkin method for solving the axially symmetric Maxwell’s equations, there has yet to be any stability or convergence results proven for this method.

97 MATHEMATICS AND COMPUTING↗

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

UWB radar technique for arc detection in coaxial cables and waveguides

As spread spectrum technology has revolutionized the communications industry, Ultra Wide Band (UWB) technology is dramatically improving radar performances. These advanced signal processing techniques have been adapted to coaxial cables and waveguides to provide new features and enhanced performance on arc detection. UWB signals constituted by a sequence of chips (properly chosen to reduce side lobes and to improve detection accuracy) are transmitted along the transmission lines at a specified Pulse Repetition Frequency (PRF) and their echoes are received by means of directional couplers. The core of the receiver is an ultra high-speed correlator implemented in a Digital Signal Processor (DSP). When a target (arc) is detected, its position and its 'radar cross section' are calculated to be able to provide the arc position along the transmission line and to be able to classify the type of detected arc. The 'background scattering' is routinely extracted from the received signal at any pulse. This permits to be resilient to the background structure of transmission lines (bends, junctions, windows, etc.). Thanks to the localization feature, segmentation is also possible for creating sensed and non-sensed zones (for example, to be insensitive to antenna load variations)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Easy-to-maintain electron cyclotron resonance (ECR) plasma sputtering apparatus featuring hybrid waveguide and coaxial cables for microwave delivery

The branched-waveguide electron cyclotron resonance plasma sputtering apparatus places quartz windows for transmitting microwaves into the plasma source not in the line of sight of the target. However, the quartz windows must be replaced after some time of operation. For maintenance, the loop waveguide branching from the T-junction must be dismounted and re-assembled accurately, which is a time-consuming job. We investigated substituting the waveguide branches with two sets of coaxial cables and waveguide/coaxial cable converters to simplify assembly as far as connection and disconnection go. The resulting hybrid system worked well for the purposes of plasma generation and film deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lightweight coaxial cable connector reduces signal loss

Connectors with milled interface surfaces for perfect electrical contact eliminate secondary- emission discharge and low signal loss in RF coaxial cables. the connectors which contain alignment and centering components for proper joint concentricity are used in communications systems designs.

Brejcha, A. G., Jr.↗

Cutter and stripper reduces coaxial cable connection time

Consisting of three pivoted members, this hand cutter and stripper positions to cut shielding and insulation at the right distance and depth. Coaxial cable is prepared quickly and accurately for connector attachment.

Thompson, F. E.↗

Risetime distortion of Shuttle Ku-band payload 50 MBPS data due to coaxial cable skin effects

This paper discusses distortion of digital signals generated in the Space Shuttle Ku-band communications systems. Specifically, the degradation considered is due to coaxial cables which interface data and clock from a source located in the payload bay to the KuSPA (Ku-Band Signal Processor Assembly) located in the avionics bay of the Shuttle. Due to the length (nearly 100 feet) and relatively narrow bandwidth of the cable, the clock and data waveforms are significantly affected by this transmission medium. This paper presents a closed form model that closely approximates the distortion of the waveforms measured in laboratory tests.

Schadelbauer, S.↗

Dynamic Termination On Radiating Coaxial Cable

Radiation pattern dithered to reduce adverse effect of nulls. In improved system for radio communication between base station and portable units within building, tunnel, ship, or other large structure, radiating or "leaky" coaxial cable serves as base-station antenna, and radiation pattern of cable dithered by dithering impedance of termination at end of cable remote from base station.

Lombardi, Robert↗

Plug-in connector socket accepts coaxial cable end

Connector which includes a spring-loaded contact to receive a protruding center conductor and an internal collet to clamp against a collar attached to a woven outer conductor, is used as a receptacle for the end of a coaxial cable. This plug-in connector socket is used successfully with remote manipulators.

Mitchell, D.↗

Design considerations for high-power VHF radar transceivers: Phase matching long coaxial cables using a cable radar

The Poker Flat 49.92-MHz MST radar uses 64 phase-controlled transmitters in individual shelters distributed throughout the antenna array. Phase control is accomplished by sampling the transmitted pulse at the directional coupler of each transmitter and sending the sample pulse back to a phase-control unit. This method requires phase matching 64 long (256 meter) coaxial cables (RG-213) to within several electrical degrees. Tests with a time domain reflectometer showed that attenuation of high frequency components in the long RG-213 cable rounded the leading edge of the reflected pulse so that the cables could only be measured to within 50 cm (about 45 deg at 49.92 MHz). Another measurement technique using a vector voltmeter to compare forward and reflected phase required a directional coupler with unattainable directivity. Several other techniques were also found lacking, primarily because of loss in the long RG-213 cables. At this point it was realized that what was needed was a simple version of the phase-coherent clear-air radar, i.e., a cable radar. The design and operation of this cable are described.

Johnson, P. E.↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗