Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CO2 Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modeling the Cost of CO2 Saline Storage on a Regional and National Level

This poster presents the results of using the FECM/NETL CO2 Saline Storage Cost Model (CO2_S_COM) to evaluate the cost of saline storage in potential storage formations in the lower 48 U.S. states. Costs were calculated for 314 saline storage formations in the CO2_S_COM geologic property database. These results were used to generate national and regional cost-supply curves. In addition, a sensitivity analysis was performed that quantified how modifying several input variables in CO2_S_COM affected the costs. Poster presented (virtual) at the 2024 AGU Conference, December 9-13, 2024, Washington, D.C.

Morgan, David [NETL]

Assessing Seismic Risk for CO2 Geologic Storage: Comparative Analysis of the Delaware Basin and Basin and Range Province Projects

ABSTRACT: Effective management of induced seismicity is critical for safe and sustainable CO2 storage. This study evaluates fault slippage risks in the Delaware Basin (Texas) and Basin and Range Province (Utah), integrating geological, operational, and geomechanical parameters to assess fault stability and seismic hazard mitigation. In the Delaware Basin, two sites were analyzed under an injection rate of 20,000 bbl/day over 25 years. One site showed low fault slip risk, while the other exhibited higher reactivation potential due to proximity to critically stressed faults. Sensitivity analysis revealed that increased pore pressure significantly heightened slip potential, highlighting the necessity of precise pressure control and real-time monitoring. In the Basin and Range Province, fault stability was evaluated at Neck of the Desert, Escalante Desert, Parowan, and Beaver sites under injection rates of 8,750 bbl/day per site over 30 years. Minimal fault slip risk was observed at Neck of the Desert and Escalante Desert sites, whereas Parowan and Beaver sites exhibited elevated slip potential due to semi-critically stressed faults sensitive to modest pore pressure increases. The findings demonstrate that fault slippage analysis, combined with sensitivity analysis of pore pressure and friction coefficients, is essential for understanding seismic risks. Continuous monitoring, adaptive injection management, and rigorous geomechanical analysis are key strategies for minimizing induced seismicity in CO2 sequestration projects.

58 GEOSCIENCES

Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide

The project Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. Sandia Technologies, LLC, and co-investigator Conrad Geoscience Corporation, examined the potential for large-scale, permanent CO2 storage in sedimentary strata within the Newark Rift Basin. The Newark Rift Basin underlies an industrialized, developed region comprising parts of New York, New Jersey, and Pennsylvania. The project characterized and investigated the suitability of Triassic age sedimentary formations for potential geologic CO2 storage. The project team drilled and cored two test wells to define the sedimentary geologic formations underlying the basin and to document or reach basement rock. With this geologic characterization phase, an integration of seismic, geologic, borehole, and formation core results provided a higher resolution assessment of CO2 storage potential. The Stockton Formation is known to be a potentially favorable geologic storage formation in the basin. In 2011, the 1-NYSTA Tandem Lot stratigraphic test well was drilled to a depth of 6,855 feet in the northern portion of the Newark Basin in southern New York State. Approximately 9 miles south-southeast on the Lamont Doherty Campus, TW-4 was drilled and cored in 2013 to a depth of 1,802 feet and contacted apparent igneous basement at a depth of 1,712 feet. Both wells penetrated the Palisades Sill ranging from 800 feet thick in the eastern well to approximately 1,800 feet in thickness at the 1-NYSTA Tandem Lot deep drill site. A diabase sill can provide an excellent seal and dense confining layer for potential CO2 storage reservoirs and flow layers that are situated beneath it within the Stockton Sandstone. The Stockton Sandstone was encountered beneath the sill in the TW-4 well on the Lamont campus, and data integration suggests that it was likely observed near total depth in the deep 1-NYSTA Tandem Lot well. The test wells confirm and define reservoirs are present beneath the sill and offer CO2 storage potential. The integration of geologic and reservoir characterization of well logs, formation cores, and formation fluids indicated Triassic age lacustrine playa lake and mudbank shales of the Upper Passaic Group can provide an effective seal for the porous and permeable underlying sandstone reservoir layers. This project acquired seismic data, drilled borehole well logs, acquired core samples, and integrated these findings to provide a better understanding of the subsurface geologic formations in the Newark Rift Basin. These findings have contributed to a higher degree of accuracy in predicting potential geologic storage opportunities, while refining geologic storage capacity estimates for the indicated reservoirs and flow units.

.las

Characterization of Most Promising Sequestration Formations in the Rocky Mountain Region

The project Characterization of Most Promising Sequestration Formations in the Rocky Mountain Region is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The Rocky Mountain Carbon Capture and Storage (RMCCS) project investigated multiple geologic formations and characterized a local site on the Colorado Plateau for future CCS opportunities. The RMCCS project focused on the Cretaceous Dakota, Jurassic Entrada, and Pennsylvanian Weber Sandstones, the three largest regional formations. All formations in this project are potential CO2 storage resources for future power plants, natural gas processing plants, cement plants, and oil shale development projects. The area adjacent to Craig, Colorado, (Sand Wash Basin) was the area selected for detailed geologic characterization on the RMCCS project. The basin was selected in part because the geology can be extrapolated to other sites on the Colorado Plateau. Field mapping and seismic surveys were conducted to identify and evaluate the basin's structural configuration. A 9,745-foot deep characterization well was drilled to collect 131 feet of core and a suite of geophysical well log data. Petrophysical tests on samples of core were used to calibrate geophysical log data, which can be used to obtain storage resource estimates and evaluate associated uncertainty as well as simulate the hydrologic behavior of injected CO2. A detailed analysis of the primary formations (Dakota, Entrada and Weber sandstones) yielded a more accurate CO2 storage resource assessment for these formations within the Colorado Plateau; RMCCS estimates indicate a total CO2 storage resource of more than 38,000 million metric tons. The characterization of the Sand Wash Basin (2-D seismic surveys, multiple well logs and lithological, petrophysical and geochemical analyses) allowed for a detailed 3-D model to be constructed. The model served as the framework for analyses ranging from CO2 storage resource, injectivity, and subsurface flow to uncertainty estimates to evaluation of risk.

2-D seismic

Implementing Large-Scale CCS in Complex Geologic Reservoirs: Insights from Three Appalachian Basin Case Studies

This paper presents three design case studies for implementing large-scale geologic carbon storage in the Appalachian Basin region of the midwestern United States. While the Appalachian Basin has a challenging setting for carbon storage, the three case studies detailed in this article demonstrate that there are realistic options for implementing carbon storage in the basin. Carbonate rock formations, depleted hydrocarbon reservoirs, and moderate-porosity sandstones can be utilized as carbon-storage reservoirs in the Appalachian Basin. While these are not typical concepts for CO2 storage, the storage zones have advantages such as defined trapping mechanisms, multiple caprocks, and defined boundaries that are not always present in thick, permeable sandstones being targeted for many carbon-storage projects. The geologic setting, geotechnical parameters, and hydrologic setting for the three case studies are provided, along with the results of reservoir simulations of the CO2 injection-deployment strategies. The geological rock formations available for CO2 storage in the Appalachian Basin are more localized reservoirs with defined boundaries and finite storage capacities. Simulation results showed that accessing carbon-storage resources in these fields may require wellfields with 2–10 injection wells. However, these fields would have the capacity to inject 1–3 million metric tons of CO2 per year and up to 90 million metric tons of CO2 in total. The CO2 storage resources would fulfill decarbonization goals for many of the natural-gas power plants, cement plants, hydrogen plants, and refineries in the Appalachian Basin region.

Sminchak, Joel

Modeling commercial-scale CO 2 storage in the gas hydrate stability zone with PFLOTRAN v6.0

Abstract. Safe and secure carbon dioxide (CO2) storage is likely to be critical for mitigating some of the most dangerous effects of climate change. In the last decade, there has been a significant increase in activity associated with reservoir characterization and site selection for large-scale CO2 storage projects across the globe. These prospective storage sites tend to be selected for their optimal structural, petrophysical, and geochemical trapping potential. However, it has also been suggested that storing CO2 in reservoirs within the CO2 hydrate stability zone (GHSZ), characterized by high pressures and low temperatures (e.g., Arctic or marine environments), could provide a natural thermodynamic barrier to gas leakage. Evaluating the prospect of commercial-scale, long-term storage of CO2 in the GHSZ requires reservoir-scale modeling capabilities designed to account for the unique physics and thermodynamics associated with these systems. We have developed the HYDRATE flow mode and the accompanying fully implicit parallel well model in the massively parallel subsurface flow and reactive transport simulator PFLOTRAN to model CO2 injection into the marine GHSZ. We have applied these capabilities to a set of CO2 injection scenarios designed to reveal the challenges and opportunities for commercial-scale CO2 storage in the GHSZ.

carbon storage

Hero Carbonsafe Phase 2 Project in the Columbia River Basalt Group: Technical Program Overview

The Hermiston, Oregon Basalt CarbonSAFE Phase II project (HERO CarbonSAFE) seeks to accelerate the deployment of commercial carbon dioxide (CO2) storage projects in basaltic rocks. Hermiston is located near the center of the Columbia River Basalt Group (CRBG), which is one of the largest basalt flows in the US. Basalt CO2 storage has potential advantages to conventional saline storage reservoirs including 1. The potential for rapid mineralization of CO2, 2. associated decreases in pressure and CO2 migration risks, 3. reduced long-term monitoring requirements with respect to plume tracking, 4. widespread geographic distribution and, 5. large storage potential due to thickness, porosity, and CO2 interactions with basalt. For locations such as the Pacific Northwest (PNW), Hawaii, Iceland, India and Japan, whose localities are isolated from large sedimentary basins offering conventional saline storage options, basalt may offer the only feasible option for local CO2 storage. However, mineralization/basalt storage still has many uncertainties, as there are limited field-scale assessments of CO2 storage in basalt. There are significant uncertainties hindering the effective implementation of carbon capture utilization and storage (CCUS) in basalt. These include the lack of proven storage capacities, challenges in methodologies for modeling the area of review in igneous formations, limited understanding of mineralization kinetics and timing, and uncertainties in injectivity. Additionally, the domestic availability of specialized services and drilling expertise is constrained, and existing CCUS permitting and regulatory frameworks, originally developed for conventional saline reservoirs, may not adequately address the unique requirements of basalt systems. HERO CarbonSAFE is designed to address major research gaps and uncertainties associated with basalt storage. Specifically, the project will assess the feasibility of CO2 injection in the deep layered basalts of the CRBG, long-term storage (mineralization), practical approaches for large-scale implementation (50+ million metric tons of CO2 over 30 years), lithology-specific risks, and the technoeconomic potential for CO2 storage in basalts.

58 GEOSCIENCES

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump

Modeling Co2 Flow Through Faulted/Fractured Reservoirs Using Tedfm in Corner-Point Grids

Interest in underground CO2 storage has increased significantly over the last decade, driven by growing concern about global warming and rising levels of greenhouse gases in the atmosphere. Given that CO2 accounts for 80% of these greenhouse gases, carbon capture, utilization, and storage (CCUS) is considered one of the most direct approaches to achieving the net-zero carbon target. Although CO2 storage in deep saline aquifers and depleted gas reservoirs has been studied extensively, most studies use commercial simulators that model faults/fractures by simply modifying the transmissibility in the direction perpendicular to the fault surfaces. This work shows that this simplistic approach ignores the accelerated flow in the directions parallel to the fault plane, leading to significantly higher leakage along the fault surface. To accurately model CO2 flow in faulted reservoirs, we present the first transient embedded discrete-fracture model for corner-point grids (tEDFM-CPG). By comparing the tEDFM-CPG results with high-resolution reference solutions, we show that this approach is accurate and efficient at predicting CO2 flow in faulted/fractured reservoirs. In conclusion, this work presents the use of mixed reality (MR) to efficiently observe CO2 gas migration in the interior of these corner-point grid systems.

02 PETROLEUM

MRCI Subtask 2.4/2.5: Regional/Subregional Analysis and Risk Assessment Final Technical Summary Report

The objective of the Midwest Regional Carbon Initiative (MRCI) project is to implement a collaborative Regional Initiative (RI) to accelerate the deployment of carbon capture, and storage (CCS) in the Midwest-Northeastern quadrant of the United States. This report is a Technical Summary report describing work performed on Tasks 2.4 (Conducting Regional/Subregional Analysis) and 2.5 (Assessing and Managing Risk) during the MRCI project. In Task 2.4, detailed numerical reservoir simulation models were developed for selected carbon storage (CS) systems identified under Task 2.1 (Battelle, 2021a) in the MRCI study area. The objective of Task 2.4 is to demonstrate a dynamic modeling methodology for evaluating the suitability of the (selected) CS systems in the MRCI region for hosting a commercial-scale storage project. In this study, CO2 injectivity was evaluated for different CS systems with an annual injection rate of 1 million metric tonnes (MMT) of CO2 considered as the minimum requirement for a commercial scale project. The objective of Task 2.5 is to assess key risks associated with storing CO2 in the different CS systems across the MRCI region and to demonstrate a method(s) for assessing these risks that may be used by developers of future CO2 storage projects in the region. The risk analysis was limited to evaluating two types of leakage risks (i.e., wellbore leakage, flow across unfractured caprock) at three modeled sites considered in Task 2.4.

MRCI,Report,Summary,Technical Challenges,dynamic m

Optimal CO2 Transport and Storage Cost Screening: Application Example

Poster on “Optimal CO2 Transport and Storage Cost Screening: Application Example” for the CCUS 2025 conference held in Houston, Texas March 3-5, 2025. A major challenge to commercial scale CCS deployment from the perspective of coal and natural gas-fired power plants is understanding cost-optimal CO2 transport and viable geologic storage options. This study demonstrates unique workflows, using NETL-developed, publicly-available models and tools, to efficiently estimate optimal CO2 transport and storage (T&S) costs for each of the CO2 sources in NETL’s Carbon Capture Retrofit Databases (CCRD) for Electricity Generating Units. The results demonstrate the impact of cost-drivers on optimal T&S, and trends in optimal T&S data, based on real point sources that could be retrofitted with CO2 source technologies.

application example

Fracture Network Quantification during CO2 Injection

This is the presentation prepared for the ARMA 2025 (59th US Rock Mechanics/Geomechanics Symposium) Conference held in Santa Fe, New Mexico, June 8-11, 2025. Accurate mapping and quantification of these networks are essential to ensure the integrity of CO2 storage reservoirs, understand and reduce potential leakage, and maintain long-term environmental safety. This study presents a novel machine learning-driven approach, integrated with geomechanical analysis, to quantify fracture networks and assess their spatial distribution during CO2 injection. This paper combines microseismic monitoring data with principles of hydraulic diffusivity and geomechanical analysis to characterize reservoir scale fracture network. The novelty of our approach lies in its capacity to assimilate time-dependent pressure data and microseismicity into a cohesive framework, which not only identifies microseismic triggering fronts but also tracks fracture distribution during active injection. Besides, leveraging image log data and analysis our approach also provides another angle of the insights to solidate the fracture networks understanding and geomechanical impacts. Key results from our study include the detection of over 100 distinct fracture clusters across the injection site, with fracture orientations strongly correlated with the prevailing in-situ stress field.

CO2 storage and sequestration

Fracture Network Quantification during CO2 Injection

This is the conference paper accompanying an oral presentation at the ARMA 2025 (59th US Rock Mechanics/Geomechanics Symposium) Conference held in Santa Fe, New Mexico, June 8-11, 2025. Accurate mapping and quantification of these networks are essential to ensure the integrity of CO2 storage reservoirs, understand and reduce potential leakage, and maintain long-term environmental safety. This study presents a novel machine learning-driven approach, integrated with geomechanical analysis, to quantify fracture networks and assess their spatial distribution during CO2 injection. This paper combines microseismic monitoring data with principles of hydraulic diffusivity and geomechanical analysis to characterize reservoir scale fracture network. The novelty of our approach lies in its capacity to assimilate time-dependent pressure data and microseismicity into a cohesive framework, which not only identifies microseismic triggering fronts but also tracks fracture distribution during active injection. Besides, leveraging image log data and analysis our approach also provides another angle of the insights to solidate the fracture networks understanding and geomechanical impacts. Key results from our study include the detection of over 100 distinct fracture clusters across the injection site, with fracture orientations strongly correlated with the prevailing in-situ stress field.

CO2 storage and sequestration

Carbonate formation on Mars: Latest experiments

Laboratory simulations of Martian CO2 storage address whether carbonate formation could have reduced CO2 pressure from a hypothetical greater than 1 bar to the present 7 mbar in less than or equal to 3 to 4 billion years. This problem is addressed with experiments and analysis designed to verify and improve previous kinetic measurements, reaction mechanisms, and product characterizations, with the goal of improving existing models of Martian CO2 history. A sensitive manometer monitored the pressure drop of CO2 due to uptake by powdered silicate for periods of 3 to 100+ days. Pressure drops for diopside 1 and basalt show rapid short-term (approximately one day) CO2 uptake and considerably slower long-term pressure drops. Curves for diopside 2, olivine 1, and olivine 2 are qualitatively similar to those for diopside 1, whereas quartz and plagioclase show near-zero short-term pressure drops and very slow long-term signals, indistinguishable from a leak (less than 10(exp 11) mol/sq m/s).

Stephens, S. K.

MRCI Subtask 2.1: Defining Sub-Regional Carbon Storage Systems Final Technical Summary Report

In order to assess the regional and subregional geologic framework of the MRCI area and expand carbon dioxide (CO2) storage characterization efforts in this larger region, the current state of geologic knowledge relative to carbon storage (CS) has been summarized by compiling available geologic data and interpretive results into a centralized resource under Subtask 2.1. The MRCI region is a large area, which includes (1) part of the Forest City Basin and Western Arches, (2) Illinois Basin, (3) Upper Mississippi Embayment, (4) Michigan Basin, (5) Central Arches, (6) Appalachian Basin, and (7) Atlantic Coastal Plain and West Atlantic basins. Basins and arches are subdivided into areas of similar geology based on geologic structures and state-specific stratigraphic nomenclature. A concerted effort was made to present the current understanding of rock-unit stratigraphy in the subsurface of each basin and arch region (and subdivisions therein). Rock units are characterized based on their relative CS potential (saline reservoirs, confining intervals, etc.) within CS systems. CS systems are defined by regional confining units (usually thick, widespread shales), and contain all reservoirs and strata between the regional confining units. Report Authors – Steve Greb and Tom Sparks (Kentucky Geological Survey), Mark Kelley, Sanjay Mawalkar, John Hershberger, Priya Ravi Ganesh, Derrick James, and Stuart Skopec (Battelle), Charles Bopp, Yaghoob Lasemi and Hannes Leetaru (deceased) (Illinois State Geological Survey), Kristin Carter (Pennsylvania Geological Survey), William Harrison (Michigan Geological Repository for Research and Education – Michigan Geological Survey), Susan Pool (West Virginia Geological and Economic Survey), James McDonald (Ohio Geological Survey), John Schmelz (Rutgers University), Ryan Clark (Iowa Geological Survey). Other Technical Contributors – Seth Carpenter and John Hickman (Kentucky Geological Survey), Jessica Moore, Eric Lewis, Philip Dinterman, Timothy Vance, and Gary Daft (West Virginia Geological and Economic Survey), Michele Cooney, Robin Anthony, Cheyenne Woodward, and Katherine Schmid (Pennsylvania Geological Survey), Autumn Haagsma and Amber Conner (Michigan Geological Repository for Research and Education – Michigan Geological Survey), Kenneth Miller (Rutgers University), Ashley Douds and Valerie Beckham-Feller (Indiana Geological & Water Survey), Michael Solis (Ohio Geological Survey).

Appalachian,Arches,Forest City,Illinois,MRCI,Michi

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.