Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CESIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A study of environmental effects caused by cesium from ion thrusters

The ATS-F satellite will carry two cesium ion thrusters. Cesium is a material that is not present in the upper atmosphere, and there is concern that the introduction of this material may result in some unexpected behavior. A study has been conducted to assess the magnitude of the effects that are to be expected. No observable effects were found as a result of the study. Consideration was given to the origin and destination of the material and the various reactions that could occur. The origin was considered to be anywhere in space from altitudes of about 100 km upward. The probable short term destination is in the form of cesium ions trapped in the earth's magnetic field or as ions and atoms in the heterosphere. The maximum possible number of cesium atoms in the field of view of an earth based observer is of the order of one million per square centimeter, far too few to be observable by visible, near-visible, or radio-frequency means. Further, no phenomena could be found that would result in the occurance of an observable event.

Source record

Probe measurements of a cesium plasma in a simulated thermionic energy converter

Cesium-filled thermionic energy converters are considered as electrical energy sources in future spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency impose stringent constraints on the converter fabrication. The converter physics for reducing operating temperatures and cesium plasma losses are being studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.

Performance tests of a thermionic converter with an oxygenated cesium reservoir

Cesium oxide/cesium solutions as a possible source of oxygen and cesium are investigated. A converter-reservoir system which allows multiple additions of oxygen with intervening thermionic performance tests was developed. The experimental data cover the cesium oxide mole fraction range of 0 to 0.018 with thermionic performance measurements in the emitter temperature range of 1600 to 1900 K. The data showed that the thermionic performance was unaffected by the presence of cesium oxide in this mole fraction range and higher mole fractions appear to be required for the proper oxygen arrival rate at the emitter surface.

Gunther, B.

Low-work-function surfaces produced by cesium carbonate decomposition

Cesium carbonate (Cs2CO3) was heated to the decomposition temperature of approximately 600 C. The nonvolatile decomposition products were condensed on a nickel substrate while the carbon dioxide was removed by pumping. The deposited material is characterized by an effective work function of between 1.05 and 1.15 eV at 450 K and by photoemission in the visible and near-infrared region of the spectrum. It is suggested that the deposited material consists of Cs2O, possibly Cs2O2, and adsorbed cesium. Silver, evaporated from a heated silver bead, produced the typical photoemissive and thermionic properties of a silver-oxygen-cesium (S-1) photocathode. The material may be of interest for thermionic energy converters and for the formation of silver-oxygen-cesium photocathodes.

Briere, T. R.

Pulsed laser deposition assisted epitaxial growth of cesium telluride photocathodes for high brightness electron sources

The development of high-brightness electron sources is critical to state-of-the-art electron accelerator applications like X-ray free electron laser (XFEL) and ultra-fast electron microscopy. Cesium telluride is chosen as the electron source material for multiple cutting-edge XFEL facilities worldwide. This manuscript presents the first demonstration of the growth of highly crystalized and epitaxial cesium telluride thin films on 4H-SiC and graphene/4H-SiC substrates with ultrasmooth film surfaces. The ordering of the film was characterized by in situ reflection high energy electron diffraction and multiple X-ray diagnostics. The results of the quantum efficiency performance for epitaxial cesium telluride photocathodes are also reported.

43 PARTICLE ACCELERATORS

High-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes

Lanthanum hexaboride electrodes in 1700 K cesium diodes may triple power outputs compared with those demonstrated for nuclear thermionic space applications. Still greater relative gains seem possible for emitters below 1700 K. Further improvements in cesium diode performance should result from the lower collector temperatures allowed for earth and low power space duties. Decreased temperatures will lessen thermal transport losses that attend thermionic conversion mechanisms. Such advantages will add to those from collector Carnot and electrode effects. If plasma ignition difficulties impede diode temperature reductions, recycling small fractions of the output power could provide ionization. So high efficiency, low temperature cesium diodes with lanthanum hexaboride electrodes appear feasible.

Morris, J. F.

High-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes

Lanthanum-hexaboride electrodes in 1700 K cesium diodes may triple power outputs compared with those demonstrated for nuclear thermionic space applications. Still greater relative gains seem possible for emitters below 1700 K. Further improvements in cesium-diode performance should result from the lower collector temperatures allowed for earth and low-power-space duties. Decreased temperatures will lessen thermal-transport losses that attend thermionic-conversion mechanisms. Such advantages will add to those from collector-Carnot and electrode effects. If plasma ignition difficulties impede diode temperature reductions, recycling small fractions of the output power could provide ionization. So high-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes appear feasible.

Morris, J. F.

Operational stability of rubidium and cesium frequency standards

In the course of testing various rubidium and cesium frequency standards under operational conditions for use in NASA tracking stations, about 55 unit-years of relative frequency measurements for averaging times from 10 to 10 to the 7th power have been accumulated at Goddard Space Flight Center (GSFC). Statistics on the behavior of rubidium and cesium standards under controlled laboratory conditions have been published, but it was not known to what extent the lesser controlled environments of NASA tracking stations affected the performance of the standards. The purpose of this report is to present estimates of the frequency stability of rubidium and cesium frequency standards under operational conditions based on the data accumulated at GSFC.

Lavery, J. E.

A comparison of the cesium and hydrogen hyperfine frequencies by means of Loran-C and portable clocks

A comparison of the hydrogen and cesium hyperfine frequencies is made using a hydrogen maser calibrated directly against the Flexible Bulb Large Storage Box Hydrogen Maser and a Hewlett-Packard portable high performance cesium clock calibrated indirectly against the USNO Master Clock via a Loran-C link. The portable cesium clock is transported from the USNO to Harvard University in operating condition. This allows the evaluation of the portable clock's performance under transport. Data are presented on the epoch and frequency stability of the portable clock under transport as well as the usefulness of a closure measurement in determining clock drift.

Reinhardt, V. S.

The adsorption of cesium on lanthanum hexaboride surfaces

The adsorption/desorption characteristics of cesium on clean and oxygen-covered LaB6 (100) surfaces were studied using various surface analysis techniques. On the initially clean surface (phi = 2.77 eV), adsorption produces a minimum work function of 1.96 eV and a saturation work function of 2.07 eV. For the oxygen-saturated surface, the cesium adsorption curve shows no minimum, the lowest work function (1.35 eV) occurring at cesium saturation. The utility of LaB6 (100) as an emitter or collector in thermionic converter applications (particularly for space nuclear electric propulsion) is evaluated.

Davis, P. R.

X-ray photoemission studies of superficially oxidized cesium antimonide photoemitters

Superficially oxidized cesium antimonide photoemitting surfaces prepared in ultrahigh vacuum were studied by X-ray photoelectron spectroscopy. Oxidation of Cs3Sb to produce a surface with enhanced photosensitivity converts part of the antimony to elemental antimony and part of the cesium to cesium suboxide. The latter is identified on the basis of an O1 s peak at 531.3 eV, characteristic of Cs11O3. The production of Cs2O is not ruled out in this process since its signature at 527.5 eV is masked by an antimony shake-up peak at 527 eV.

Bates, C. W., Jr.

Study of radiatively sustained cesium plasmas for solar energy conversion

The results of a study aimed at developing a high temperature solar electric converter are reported. The converter concept is based on the use of an alkali plasma to serve as both an efficient high temperature collector of solar radiation as well as the working fluid for a high temperature working cycle. The working cycle is a simple magnetohydrodynamic (MHD) Rankine cycle employing a solid electrode Faraday MHD channel. Research milestones include the construction of a theoretical model for coupling sunlight in a cesium plasma and the experimental demonstration of cesium plasma heating with a solar simulator in excellent agreement with the theory. Analysis of a solar MHD working cycle in which excimer laser power rather than electric power is extracted is also presented. The analysis predicts a positive gain coefficient on the cesium-xenon excimer laser transition.

Palmer, A. J.

Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

Remer, D. S.

Study of a cesium plasma as a selective emitter for thermophotovoltaic applications

This experimental study evaluates the potential of a cesium plasma as an emitter for a thermophotovoltaic (TPV) energy conversion system. A cesium plasma, as a result of the ground-state transitions of its single outer-shell electron, produces large amounts of radiation in the 850-890-nm wavelength region. This would provide excellent coupling to silicon, gallium arsenide, and indium phosphide photovoltaic cells. Measurements of the radiative efficiency, the sum of the power at the 852 and 894 nm wavelengths relative to the total emitted power, were made and correlated to the plasma operating variables. It was determined that, for atomic density in the range (3-6) x 10 exp 21/cu cm and electron temperature in the range 2000-3000 K, radiative efficiencies in excess of 70 percent are attainable. This would indicate that a cesium plasma with its selective emission characteristics and low electron operating temperatures of 2000-3000 K would be an excellent candidate as an emitter in a TPV system.

Lowe, R.

Hydrogen masers and cesium fountains at NRC

The NRC masers H-3 and H-4 have been operating since June 1993 with cavity servo control. These low-flux active H masers are showing stabilities of about 10(exp -15) from 1 hour to several days. Stability results are presented, and the current and planned uses of the masers are discussed. A cesium fountain primary frequency standard project has been started at NRC. Trapping and launching experiments with the goal of 7 m/s launches are beginning. We discuss our plans for a local oscillator and servo that exploit the pulsed aspect of cesium fountain standards, and meet the challenge of 10(exp -14) tau(exp -1/2) stability without requiring masers. At best, we expect to run this frequency standard initially for periods of hours each working day rather than continuously for years, and so frequency transfer to outside laboratories has been carefully considered. We conclude that masers (or other even better secondary clocks) are required to exploit this potential accuracy of the cesium fountain. We present and discuss our conclusion that it is feasible to transfer frequency in this way with a transfer-induced uncertainty of less than 10(exp -15), even in the presence of maser frequency drift and random walk noise.

Boulanger, J.-S.

A heat and mass transfer model for evaluation of damaged cesium chloride radiological sources

Radiological sources are vital to many applications, and typically contain byproducts from waste streams which decay over time to form complex mixtures of elements. Daughter products resulting from these decay processes can introduce complicating factors to the integrity and safety of the vessel that contains the radiological material. Sources containing cesium 137 ( 137 Cs) are of particular interest, because the decay of this isotope produces barium metal which reacts readily and exothermically with oxygen. This work employs physics-based numerical tools to examine the thermal response of a radiological source containing a mixture of cesium and barium in the event that vessel walls are damaged and atmospheric gases contact source material. A parametric study was conducted to determine the sensitivity of the response to various factors, including vessel geometry, source material age, the degree of vessel damage, and other parameters. Here, it was found that the peak temperatures that occurred within the source material strongly depend on these parameters, particularly vessel geometry and age, which determine whether a breach would be a relatively minor accident or a catastrophic incident. Finally, the model’s sensitivity to uncertain thermophysical properties is discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

High-Vacuum Condenser Design: Experimental Effects from Cesium and Mercury Ion Beams

Effects of variable-energy electrostatic rocket-engine ion exhaust beams that pertain to the design of high-vacuum condensers are discussed. Three ion-engine beam sources, using cesium and mercury as propellants, were operated at energy levels of 200 to 9000 electron volts and currents of 0.002 to 0.200 ampere. Five condenser geometries, having surface areas from 0.287 to 5.76 square meters, were tested. Values for a function of the accommodation and condensation coefficients, which appears in an existing theoretical analysis, were determined. Although exhibiting rather wide variations in some tests, the values were estimated at approximately 0.15 for cesium and 0.015 for mercury. A method of estimating condenser surface area requirements is given.

MERCURY /METAL/