Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CERENKOV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center Francois Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the dose measurements performed with the DosiMap and with dosimetric films for three different irradiation configurations showed discrepancies smaller than 3.5% for a 2 mm spatial resolution. Two innovative discrimination solutions were demonstrated to separate the scintillation from the Cerenkov radiation. It was also shown that the DosiMap, which is water equivalent, fast, and user friendly, is a very promising tool for radiotherapy quality assurance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A test of incoherent Cerenkov radiation for VLF hiss and other magnetospheric emissions

Consideration of incoherent Cerenkov radiation from intense fluxes of electrons in the magnetosphere as a source of VLF hiss and several other emission phenomena. A procedure for calculating the Cerenkov and cyclotron radiation power from a spectrum of electrons in a test volume is outlined, as well as a ray-tracing routine for determining the path that the emitted power follows through the magnetosphere. Comparisons are made between a VLF hiss event and an energetic particle spectrum observed simultaneously with the Injun 5 spacecraft. Calculated power and fields for incoherent Cerenkov radiation are two orders of magnitude below the observed VLf hiss values, although the spectral shapes are similar. It is concluded that a partially coherent or amplified Cerenkov source or an instability is located in the altitude range from 3000 to 10,000 km. Calculations regarding Cerenkov radiation as a possible source for other wave phenomena indicate that upper hybrid resonance noise and fast hisslers may be understood in terms of incoherent Cerenkov radiation, but that V-shaped VLF hiss, saucers, ELF hiss, and Io-related Jovian decametric radiation may not.

Taylor, W. W. L.↗

Cerenkov x total energy telescopes for the study of the mass composition of cosmic rays

The mass resolution attainable with cosmic ray telescopes employing Cerenkov counters for velocity measurement was examined. It is shown that in most cases, the limiting mass resolution is determined by the resolution of the Cerenkov counter. The resolution achieved in the UNH telescope flown on a balloon in 1977 is studied as a function of charge and energy. This telescope determines the mass using the Cerenkov x total energy technique. It is shown that the mass resolution for heavier nuclei can be accurately predicted using the response of the Cerenkov counter to sea level mu-mesons. The actual in flight resolution for heavier nuclei, including broadening effects, may be predicted using the beta = 1 Cerenkov distributions, and independently by studying the distribution function of the differences of the two banks of photomultipliers employed on each Cerenkov counter.

Webber, W. R.↗

SU-E-T-108: An Investigation of Cerenkov Light Production in the Exradin W1 Scintillator Under Various Measurement Conditions

Purpose: To investigate the effects of depth, fiber-optic cable bends, and incident radiation angle on Cerenkov production in the Standard Imaging Exradin W1. Methods: Measurements were completed using a Varian Clinac 21EX linear accelerator with an Exradin W1 scintillator as well as a cable-only scintillator (no scintillation material) to isolate the Cerenkov signal. The effects of cable bend radius and location were investigated by bending the fiber-optic cable into a circle with radii ranging from 1.0 to 10.8 cm and positioning the center of the coil at distances ranging from 10.0 to 175.0 cm from the photodiode. The effects of depth and incident radiation angle were investigated by performing measurements in water at depths ranging from 1.0 cm to 25.0 cm and angles ranging from 0° to 80°. Eclipse treatment-planning software was utilized to ensure a consistent dose was delivered to the W1 regardless of depth or angle. Results: Measured signal in both channels of the cable-only scintillator decreased as the bend radius decreased and as the distance between the bend and photodiode increased. A fiber bend of 1.0 cm radius produced a 17.1% decrease in the green channel response in the cable-only scintillator. The effect of depth was less severe; a maximum increase of 6.6% in the green channel response was observed at a depth of 25.0 cm in the W1. In the angular dependence investigation, the signal in both channels of the W1 peaked at an angle of 40°; which is in agreement with the nominal Cerenkov emission angle of 45°. Conclusion: The green channel response in the W1 (mainly Cerenkov signal) varied with depth, fiber-optic cable bends, and incident radiation angle. Fully characterizing Cerenkov production is essential to ensure it is properly accounted for in scintillator measurements. Research funding and materials received by Standard Imaging, Inc. (Middleton WI)

07 ISOTOPE AND RADIATION SOURCES↗

Gadolinium-doped water cerenkov-based neutron and high energy gamma-ray detector and radiation portal monitoring system

A water Cerenkov-based neutron and high energy gamma ray detector and radiation portal monitoring system using water doped with a Gadolinium (Gd)-based compound as the Cerenkov radiator. An optically opaque enclosure is provided surrounding a detection chamber filled with the Cerenkov radiator, and photomultipliers are optically connected to the detect Cerenkov radiation generated by the Cerenkov radiator from incident high energy gamma rays or gamma rays induced by neutron capture on the Gd of incident neutrons from a fission source. The PMT signals are then used to determine time correlations indicative of neutron multiplicity events characteristic of a fission source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cerenkov luminescence endoscopy: Improved molecular sensitivity with β - -emitting radiotracers

Cerenkov luminescence endoscopy (CLE) is an optical technique that captures the Cerenkov photons emitted from highly energetic moving charged particles (β + or β $-$ ) and can be used to monitor the distribution of many clinically available radioactive probes. A main limitation of CLE is its limited sensitivity to small concentrations of radiotracer, especially when used with a light guide. We investigated the improvement in the sensitivity of CLE brought about by using a β $-$ radiotracer that improved Cerenkov signal due to both higher β-particle energy and lower γ noise in the imaging optics because of the lack of positron annihilation. Here, the signal-to-noise ratio (SNR) of 90 Y was compared with that of 18 F in both phantoms and small-animal tumor models. Sensitivity and noise characteristics were demonstrated using vials of activity both at the surface and beneath 1 cm of tissue. Rodent U87MG glioma xenograft models were imaged with radiotracers bound to arginine-glycine-aspartate (RGD) peptides to determine the SNR. As a result, γ noise from 18 F was demonstrated by both an observed blurring across the field of view and a more pronounced fall-off with distance. A decreased γ background and increased energy of the β particles resulted in a 207-fold improvement in the sensitivity of 90 Y compared with 18 F in phantoms. 90 Y-bound RGD peptide produced a higher tumor-to-background SNR than 18 F in a mouse model. In conclusion, the use of 90 Y for Cerenkov endoscopic imaging enabled superior results compared with an 18 F radiotracer.

60 APPLIED LIFE SCIENCES↗

A threshold gas Cerenkov detector for the spin asymmetries of the nucleon experiment

In this study, we report on the design, construction, commissioning, and performance of a threshold gas Cerenkov counter in an open configuration, which operates in a high luminosity environment and produces a high photo-electron yield. Part of a unique open geometry detector package known as the Big Electron Telescope Array, this Cerenkov counter served to identify scattered electrons and reject produced pions in an inclusive scattering experiment known as the Spin Asymmetries of the Nucleon Experiment E07-003 at the Thomas Jefferson National Accelerator Facility (TJNAF) also known as Jefferson Lab. The experiment consisted of a measurement of double spin asymmetries A || and A ⊥ of a polarized electron beam impinging on a polarized ammonia target. The Cerenkov counter's performance is characterised by a yield of about 20 photoelectrons per electron or positron track. Thanks to this large number of photoelectrons per track, the Cerenkov counter had enough resolution to identify electron-positron pairs from the conversion of photons resulting mainly from π 0 decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the mode composition of an X-band overmoded O-type Cerenkov high-power microwave oscillator

Overmoded slow wave structures (SWSs) with large diameter are utilized in O-type Cerenkov high-power microwave (HPM) sources for their high power capacity. However, multi-modes may be output simultaneously in the overmoded O-type Cerenkov HPM sources. In order to achieve high mode purity, the mode composition of the output power should be analyzed quantitatively when the structure of this type of device is being optimized. Two accurate numerical methods of making quantitative analysis of the mode composition in particle-in-cell model are introduced in this paper. And then, the mode composition of an X-band O-type Cerenkov oscillator with overmoded SWSs (D/{lambda} Almost-Equal-To 2.7) is analyzed. The analysis indicates that appropriate selection of the parameters of overmoded SWSs and electron beam is important, as mentioned in previous reports, for realizing mode selection in beam-wave interaction. Besides, designing of the mode conversion effect, which is rarely discussed, can also affect the mode purity of output power. After adjustment of the dimensions of the tapered waveguide, which converts the combination of 'surface wave' and 'volume wave' to the 'volume wave' in the output waveguide, the percentage of total output microwave power carried by the TM{sub 01} mode is higher than 95% in the X-band overmoded Cerenkov oscillator at the diode voltage ranging from 570 kV to 750 kV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum theory of stimulated Cerenkov radiation of transverse electromagnetic waves by a low-density electron beam in a medium

The quantum theory of stimulated Cerenkov radiation of transverse electromagnetic waves by an electron beam in an anisotropic medium is presented. Relativistic quantum nonlinear equations of the Cerenkov beam instability are obtained. In the linear approximation, the quantum dispersion equation is derived and the instability growth increments are determined. The nonlinear problem of the saturation of the quantum Cerenkov beam instability is solved. (cerenkov radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cerenkov radio pulses from electromagnetic showers in the time domain

The electric field of the Cerenkov radio pulse produced by a single charged particle track in a dielectric medium is derived from first principles. An algorithm is developed to obtain the pulse in the time domain for numerical calculations. The algorithm is implemented in a Monte Carlo simulation of electromagnetic showers in dense media (specifically designed for coherent radio emission applications) as might be induced by interactions of ultrahigh energy neutrinos. The coherent Cerenkov radio emission produced by such showers is obtained simultaneously both in the time and frequency domains. A consistency check performed by Fourier transforming the pulse in time and comparing it to the frequency spectrum obtained directly in the simulations yields, as expected, fully consistent results. The reversal of the time structure inside the Cerenkov cone and the signs of the corresponding pulses are addressed in detail. The results, besides testing algorithms used for reference calculations in the frequency domain, shed new light into the properties of the radio pulse in the time domain. The shape of the pulse in the time domain is directly related to the depth development of the excess charge in the shower and its width to the observation angle with respect to the Cerenkov direction. This information can be of great practical importance for interpreting actual data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Cerenkov Radiation in Nonlinear Photonic Crystal Waveguides

We study nonlinear Cerenkov radiation generated from a nonlinear photonic crystal waveguide where the nonlinear susceptibility tensor is modulated by the ferroelectric domain. Nonlinear polarization driven by an incident light field may emit coherently harmonic waves at new frequencies along the direction of Cerenkov angles. Multiple radiation spots with different azimuth angles are simultaneously exhibited from such a hexagonally poled waveguide. A scattering involved nonlinear Cerenkov arc is also observed for the first time. Cerenkov radiation associated with quasi-phase matching leads to these novel nonlinear phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-C-17A-02: New Radioluminescence Strategies Based On CRET (Cerenkov Radiation Energy Transfer) for Imaging and Therapy

Purpose: Cerenkov photons are produced when charged particles, emitted from radionuclides, travel through a media with a speed greater than that of the light in the media. Cerenkov radiation is mostly in the UV/Blue region and, thus, readily absorbed by biological tissue. Cerenkov Radiation Energy Transfer (CRET) is a wavelength-shifting phenomenon from blue Cerenkov light to more penetrating red wavelengths. We demonstrate the feasibility of in-depth imaging of CRET light originating from radionuclides realized by down conversion of gold nanoclusters (AuNCs, a novel particle composed of few atoms of gold coated with serum proteins) in vivo. Methods: Bovine Serum Albumin, Human Serum Albumin and Transferrin conjugated gold nanoclusters were synthesized, characterized and examined for CRET. Three different clinically used radiotracers: 18F-FDG, 90Y and 99mTc were used. Optical spectrum (440–750 nm) was recorded by sensitive bioluminescence imaging system at physiological temperature. Dose dependence (activity range from 0.5 up to 800uCi) and concentration dependence (0.01 to 1uM) studies were carried out. The compound was also imaged in a xenograft mouse model. Results: Only β+ and β--emitting radionuclides (18F-FDG, 90Y) are capable of CRET; no signal was found in 99mTc (γ-emitter). The emission peak of CRET by AuNCs was found to be ∼700 nm and was ∼3 fold times of background. In vitro studies showed a linear dependency between luminescence intensity and dose and concentration. CRET by gold nanoclusters was observed in xenografted mice injected with 100uCi of 18F-FDG. Conclusion: The unique optical, transport and chemical properties of AuNCs (gold nanoclusters) make them ideal candidates for in-vivo imaging applications. Development of new molecular imaging probes will allow us to achieve substantially improved spatiotemporal resolution, sensitivity and specificity for tumor imaging and detection.

60 APPLIED LIFE SCIENCES↗

Cosmic ray studies with a gas Cerenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cerenkov counter (threshold 16.5 GeV/nuc) and an ionization spectrometer are presented. The gas Cerenkov counter provides an absolute energy calibration for the response of the calorimeter for the Z range of 5-26 nuclei of cosmic rays. The contribution of scintillation to the gas Cerenkov pulse height has been obtained by independently selecting particles below the gas Cerenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi-squared between a Monte Carlo simulated data and flight data. Best fit power laws were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E exp-2.7, are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer.

Balasubrahmanyan, V. K.↗

EAS Cerenkov measurements of the composition of the cosmic ray flux around 10 to the 16th power eV

Information can be obtained about the nature of a primary cosmic ray by looking at the way in which an extensive air shower (EAS) develops in the atmosphere. Heavy nuclei give rise to showers that develop high in the atmosphere and the depth of maximum development is subjected to much smaller fluctuations than is the case for showers originating from protons. This development is followed by optical methods based on the observations of Cerenkov light or fluorescence light. The Cerenkov observations have two complementary techniques: measurement of the time profile of the Cerenkov pulse with resolution of a few nanoseconds and measurement of the lateral distribution of the Cerenkov light. In each case the measured quantities must be related to some characteristic development parameters.

Dawson, B. R.↗

MCNP6 Cerenkov Radiation Feature Verification

The MCNP6 code has being upgraded to treat Cerenkov radiation emission. Emission is performed using the Frank-Tamm Cerenkov theory with piecewiseconstant coefficients. This document discusses preliminary verification efforts for the Cerenkov feature. Tests were conducted using MCNP6 version MCNP6_Beta3_branch_r. The Frank-Tamm formulation has been coded in an auxiliary Perl script cr.pl. Comparisons of the photon production per wavelength bin and the aggregate photon production are made for 4-MeV electrons and 4000- MeV alphas in water using MCNP6 and cr.pl. The agreement is excellent. Verification calculations for the spectrum of light emerging from the surface of the water are presented for constant, Cauchy, and Sellmeier treatments of the refractive index. Efforts to conduct validation studies were limited by lack of time and limited useful measured data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cerenkov-type phase-matched second-harmonic emission from GaAs/AlGaAs quantum-cascade lasers

Second-harmonic (SH) emission in the form of Cerenkov-type phase-matched radiation has been measured for quantum-cascade lasers (QCLs) with built-in nonlinearities. The QCLs operate at 10.9 {mu}m wavelength and, due to material dispersion, show a high collinear phase mismatch, resulting in low SH external conversion efficiencies on the order of 2 {mu}W/W{sup 2}. Due to our waveguide design, we were able to couple out and measure the generated SH light in the form of Cerenkov-type phase-matched radiation from the substrate of the device. The SH power collected from the Cerenkov beam leads to an increased external conversion efficiency of {approx}50 {mu}W/W{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cerenkov radiation in metallic metamaterials

The electromagnetic response of a metallic metamaterial to fast-moving electrons is studied by numerical simulations. The considered metamaterial is a one-dimensional array of slits perforated on a metallic film and is found to generate Cerenkov wakes when the electron beam travels near its surface. There is no energy threshold for the generation of such wakes, which would be promising to lower the operation energy of the electron beam in compact Cerenkov free-electron-lasers. Moreover, by analyzing the spectral dependence of the Cerenkov light, it is possible to map the dispersion relation of the guided modes supported by the metamaterial.

36 MATERIALS SCIENCE↗

Effect of multiple scattering on Cerenkov radiation from energetic electrons

Cerenkov radiation can be used as a diagnostic tool to study energetic electrons generated in ultra-intense laser matter interactions. However, electrons suffer scattering with nuclei as they move in a medium. In this article, we theoretically study the effect of multiple scattering on Cerenkov radiation, and obtain analytical formulas under some circumstances. The results show that when the speed of an energetic electron is not close to the light speed in the medium, Cerenkov radiation is just slightly decreased due to multiple scattering. In the case that the electron speed is very close to the light speed in the medium, the effect of multiple scattering becomes significant, and the radiation is dominated by bremsstrahlung.

74 ATOMIC AND MOLECULAR PHYSICS↗