Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CELL FLOW SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Redox flow cell energy storage systems

NASA-Redox systems are electrochemical storage devices that use two fully soluble Redox couples, anode and cathode fluids, as active electrode materials separated by a highly selective ion exchange membrane. The reactants are contained in large storage tanks and pumped through a stack of Redox flow cells where the electrochemical reactions (reduction and oxidation) take place at porous carbon felt electrodes. A string or stack of these power producing cells is connected in series in a bipolar manner. Redox energy storage systems promise to be inexpensive and possess many features that provide for flexible design, long life, high reliability and minimal operation and maintenance costs. These features include independent sizing of power and storage capacity requirements and inclusion within the cell stack of a cell that monitors the state of charge of the system as a whole, and a rebalance cell which permits continuous correction to be made for minor side reactions that would tend to result in the anode fluid and cathode fluids becoming electrochemically out of balance. These system features are described and discussed.

Thaller, L. H.↗

The Advantages of Non-Flow-Through Fuel Cell Power Systems for Aerospace Applications

NASA has been developing proton-exchange-membrane (PEM) fuel cell power systems for the past decade, as an upgraded technology to the alkaline fuel cells which presently provide power for the Shuttle Orbiter. All fuel cell power systems consist of one or more fuel cell stacks in combination with appropriate balance-of-plant hardware. Traditional PEM fuel cells are characterized as flow-through, in which recirculating reactant streams remove product water from the fuel cell stack. NASA recently embarked on the development of non-flow-through fuel cell systems, in which reactants are dead-ended into the fuel cell stack and product water is removed by internal wicks. This simplifies the fuel cell power system by eliminating the need for pumps to provide reactant circulation, and mechanical water separators to remove the product water from the recirculating reactant streams. By eliminating these mechanical components, the resulting fuel cell power system has lower mass, volume, and parasitic power requirements, along with higher reliability and longer life. These improved non-flow-through fuel cell power systems therefore offer significant advantages for many aerospace applications.

Hoberecht, Mark↗

NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications

NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.

Araghi, Koorosh R.↗

Development Status of PEM Non-Flow-Through Fuel Cell System Technology for NASA Applications

Today s widespread development of proton-exchange-membrane (PEM) fuel cell technology for commercial users owes its existence to NASA, where fuel cell technology saw its first applications. Beginning with the early Gemini and Apollo programs, and continuing to this day with the Shuttle Orbiter program, fuel cells have been a primary source of electrical power for many NASA missions. This is particularly true for manned missions, where astronauts are able to make use of the by-product of the fuel cell reaction, potable water. But fuel cells also offer advantages for unmanned missions, specifically when power requirements exceed several hundred watts and primary batteries are not a viable alternative. In recent years, NASA s Exploration Technology Development Program (ETDP) funded the development of fuel cell technology for applications that provide both primary power and regenerative fuel cell energy storage for planned Exploration missions that involved a return to the moon. Under this program, the Altair Lunar Lander was a mission requiring fuel cell primary power. There were also various Lunar Surface System applications requiring regenerative fuel cell energy storage, in which a fuel cell and electrolyzer combine to form an energy storage system with hydrogen, oxygen, and water as common reactants. Examples of these systems include habitat modules and large rovers. In FY11, the ETDP has been replaced by the Enabling Technology Development and Demonstration Program (ETDDP), with many of the same technology goals and requirements applied against NASA s revised Exploration portfolio.

Hoberecht, Mark A.↗

Flow cell sample generator

A sample generator system includes a fluid source and a flow cell. The sample generator system includes a sampling system in communication with the flow cell to eject a fluid sample through an orifice in the flow cell. The sample generator system includes a gas pressure at the orifice in the flow cell greater than or equal to a fluid pressure at the orifice in the flow cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

60 APPLIED LIFE SCIENCES↗

Application of Neutron Imaging to InvestigateFlow Through Fractures for EGS

This paper will describe ongoing efforts at Oak Ridge National Laboratory to develop a unique experimental capability for investigating flow through porous and fractured geological media using neutron imaging techniques. This capability is expected to support numerous areas of investigation associated with flow processes relevant to EGS including, but not limited to: experimental visualization and measurement of velocity profiles and other flow characteristics to better inform reduced-order modeling of flow through fractures; laboratory scale validation of flow models and simulators; and a 'real-time' tool for studying geochemical rock/fluid interactions by noninvasively measuring material effects such as precipitation and dissolution in EGS representative conditions. Neutron scattering and attenuation based techniques have many distinctive advantages over other radiographic imaging methods for studying certain types of physical processes because cold and thermal neutrons are more highly attenuated by materials with large Hydrogen compositions while they more easily penetrate higher Z materials, such as those used in structural applications. Experiments exploiting this behavior may therefore be devised to study flow behaviors in samples even when thick pressure vessel walls and large sample masses are present. The objective of this project is to develop an experimental setup and methodology for taking EGS representative core samples with engineered fractures and fracture features, subjecting them to a triaxial stress state at EGS representative temperatures (up to 300 degrees C), and pumping high pressure fluid through the sample while imaging and measuring fluid flow characteristics using high flux neutron beams. This effort will take advantage of signature Oak Ridge National Laboratory facilities, including the Spallation Neutron Source and High Flux Isotope Reactor, as well as its core expertise in Neutron Science. Towards this end, a geothermal pressure test cell and flow system has been developed that can accommodate 1.5 diameter, 6 long core samples and apply a radial confining pressure up to 10,000 psi with fluid flow pressures up to 5,000 psi. This cell has been specially designed to optimize the transmission of neutrons and permit improved imaging of the interior of the sample of interest. Proof of principle measurements of the system have been performed and will be discussed in this paper. Techniques for injecting fluid contrast agents to permit visualization and quantification of flow profiles are also being developed and will be described along with future development plans.

Polsky, Yarom↗

Breakthrough Flow Battery Cell Stack: Transformative Electrochemical Flow Storage System (TEFSS)

GRIDS Project: UTRC is developing a flow battery with a unique design that provides significantly more power than today's flow battery systems. A flow battery is a cross between a traditional battery and a fuel cell. Flow batteries store their energy in external tanks instead of inside the cell itself. Flow batteries have traditionally been expensive because the battery cell stack, where the chemical reaction takes place, is costly. In this project, UTRC is developing a new stack design that achieves 10 times higher power than today’s flow batteries. This high power output means the size of the cell stack can be smaller, reducing the amount of expensive materials that are needed. UTRC’s flow battery will reduce the cost of storing electricity for the electric grid, making widespread use feasible.

ARPA-E↗

System and method for minimizing transport related performance losses in a flow battery system

A flow battery system and method of operating the system minimizes performance losses. The flow battery system includes at least one cell, a first tank including a liquid electrolyte, a pump operably connected to the first tank and to the at least one cell, and a second electrolyte tank operably connected to the at least one cell. The flow battery system further includes a memory including program instructions stored therein, at least one sensor configured to a generate at least one signal associated with a sensed condition of the battery system, and a controller operably connected to the at least one sensor, the pump, and the memory and configured to execute the program instructions to determine a dead zone condition exists based upon the at least one signal, and control the pump to pulse flow of the liquid electrolyte to the at least one cell based upon the determination.

Knudsen, Edward↗

A Comparison of Flow-Through Versus Non-Flow-Through Proton Exchange Membrane Fuel Cell Systems for NASA's Exploration Missions

As part of the Exploration Technology Development Program (ETDP) under the auspices of the Exploration Systems Mission Directorate (ESMD), NASA is developing both primary fuel cell power systems and regenerative fuel cell (RFC) energy storage systems within the fuel cell portion of the Energy Storage Project. This effort is being led by the NASA Glenn Research Center (GRC) in partnership with the NASA Johnson Space Center (JSC), Jet Propulsion Laboratory (JPL), NASA Kennedy Space Center (KSC), and industrial partners. The development goals are to improve fuel cell and electrolysis stack electrical performance, reduce system mass, volume, and parasitic power requirements, and increase system life and reliability. A major focus of this effort has been the parallel development of both flow-through and non-flow-through proton exchange membrane (PEM) primary fuel cell power systems. The plan has been, at the appropriate time, to select a single primary fuel cell technology for eventual flight hardware development. Ideally, that appropriate time would occur after both technologies have achieved a technology readiness level (TRL) of six, which represents an engineering model fidelity PEM fuel cell system being successfully tested in a relevant environment. Budget constraints in fiscal year 2009 and beyond have prevented NASA from continuing to pursue the parallel development of both primary fuel cell options. Because very limited data exists for either system, a toplevel, qualitative assessment based on engineering judgement was performed expeditiously to provide guidance for a selection. At that time, the non-flow-through technology was selected for continued development because of potentially major advantages in terms of weight, volume, parasitic power, reliability, and life. This author believes that the advantages are significant enough, and the potential benefits great enough, to offset the higher state of technology readiness of flow-through technology. This paper summarizes the technical considerations which helped form the engineering judgement that led to the final decision.

Hoberecht, Mark A.↗

The Autonomous Pathogen Detection System

We developed, tested, and now operate a civilian biological defense capability that continuously monitors the air for biological threat agents. The Autonomous Pathogen Detection System (APDS) collects, prepares, reads, analyzes, and reports results of multiplexed immunoassays and multiplexed PCR assays using Luminex{copyright} xMAP technology and flow cytometer. The mission we conduct is particularly demanding: continuous monitoring, multiple threat agents, high sensitivity, challenging environments, and ultimately extremely low false positive rates. Here, we introduce the mission requirements and metrics, show the system engineering and analysis framework, and describe the progress to date including early development and current status.

59 BASIC BIOLOGICAL SCIENCES↗

Particle Size and Density Measurement

This project has developed a miniature gravity settling classifier (flow cell) and flow system that separates slurry particles by settling rate into six different Cuts. The settling rates for particles in each Cut were determined from COMSOL computational fluid dynamics (CFD) modeling of the flow in the flow cell together with particle tracking for particles of differing settling rates. For particles collected in each Cut, the particle concentration and size distribution were measured. The effective particle densities from each Cut are calculated from their respective CFD modeled settling rates using a relationship between the unhindered settling rate, particle size distribution (PSD), and effective density. The particle size and density distribution (PSDD) of the slurry sample is then calculated by combining the size and density distributions determined for the particles collected in each of the settling rate Cuts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bead-based microfluidic immunoassay for diagnosis of Johne's disease

Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.

60 APPLIED LIFE SCIENCES↗

Bead-Based Assays for Biodetection: From Flow-Cytometry to Microfluidics

ABSTRACT The potential for the use of biological agents by terrorists is a real threat. Two approaches for detection of biological species will be described: 1) The use of microbead arrays for multiplexed flow cytometry detection of cytokines and botulinum neurotoxin simulant, and 2) a microfluidic platform for capture and separation of different size superparamagnetic nanoparticles followed by on-chip fluorescence detection of the sandwich complex. The methods and automated fluidic systems used for trapping functionalized microbeads will be described. This approach allows sample, assay reagents, and wash solutions to be perfused over a micro-column of beads, resulting in faster and more sensitive assays. The automated fluidic approach resulted in up to five-fold improvements in assay sensitivity/speed as compared to identical assays performed in a typical manual batch mode. A second approach for implementing multiplexed bead-based assays without using flow cytometry detection is currently under development. The goal of the microfluidic-based approach is to achieve rapid (<20 minutes), multiplexed (> 3 bioagents) detection using a simple and low-cost, integrated microfluidic/optical detection platform. Using fiber-optic guided laser-induced fluorescence, assay detection limits were shown to be in the 100’s of picomolar range (10’s of micrograms per liter) for botulinum neurotoxin simulant without any optimization of the microfluidic device or optical detection approach. Video taping magnetic nanoparticle capture and release was used to improve understanding of the process and revealed interesting behavior.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Data File Standard for Flow Cytometry, Version FCS 3.1

The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allows files created by one type of acquisition hardware and software to be analyzed by any other type. The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.

59 BASIC BIOLOGICAL SCIENCES↗

Cell cycle arrest and induction of apoptosis of newly synthesized pyranoquinoline derivatives under microwave irradiation

A set of 2-amino-4-aryl-4H-pyrano[3,2-h]quinoline-3-carbonitrile derivatives were prepared via a one-pot, three-component condensation reaction between the substituted hydroxyquinoline derivatives, some aryl and/or hetaryl aldehydes, and malononitrile in an ethanol/piperidine solution in a microwave irradiation environment. The structure of the prepared compounds was instituted on the foundations of their spectral data: IR, {sup 1}H NMR, {sup 13}C NMR, and MS. Four human cancer cell lines, MCF-7, HCT-116, HepG-2, and A549 were utilized to evaluate the antiproliferative properties of the target compounds in comparison to the positive controls, Vinblastine and Colchicine using the MTT viability assay. The cell cycle arrest behavior, detected by propidium iodide as well as the apoptosis induction, which was monitored by the flow cytometer, using the Annexin V-FITC kits, was investigated. The results illustrated that the potent cytotoxic compounds induce cell cycle arrest at the G2/M phases and trigger apoptosis in the different tested cancer cells. Finally, the structure−activity relationship (SAR) study showcases the substitution of some specific groups at the 4-, 6-, and 9-positions in the prepared 2-amino-4H-pyrano[3,2-h]quinoline derivatives, which indicates that the lipophilicity manipulates the ability of these moieties against the diverse cell lines.

60 APPLIED LIFE SCIENCES↗

Oxidative stress induced apoptosis mediated anticancer activity of Rhus typhina fruits extract in human colon cancer

The present work was tested the anti-proliferation activity of Rhus typhina fruits extract (RTFE) in HEK293 and HT-29 cells, and studied their underlying mechanisms through the analysis of oxidative stress and apoptosis-related genes expressions by flow cytometer and RT-qPCR. In addition, the bioactive constituents were identified from RTFE by chromatography and NMR analysis. Among the various type of the fractions from the RTFE, the ethyl acetate fraction (EAF) was showed the potent anti proliferation effect in HT-29 cells. Thus EAF was selected for the further extensive analysis. Cytotoxcity and RT-qPCR results revealed that the treatment of EAF significantly inhibit the growth of the HT-29 cells by the up regulating of Bax and down regulation of Bcl-2, Survivn, AIF and SOD-2 gene expressions in time and dose dependent manner. Followed by sub G1 accumulation and the G0/G1 phase arrest, ROS production, and mitochondrial transmembrane potential (ΔΨm). Finally, the active anti-proliferations agents such as luteolin and luteolin-7-O-glucuronide were identified from EAF by NMR. This work suggests that EAF could be a functional food to treat the chronic diseases.

60 APPLIED LIFE SCIENCES↗

Long-range forces affecting equilibrium inertial focusing behavior in straight high aspect ratio microfluidic channels

The controlled and directed focusing of particles within flowing fluids is a problem of fundamental and technological significance. Microfluidic inertial focusing provides passive and precise lateral and longitudinal alignment of small particles without the need for external actuation or sheath fluid. The benefits of inertial focusing have quickly enabled the development of miniaturized flow cytometers, size-selective sorting devices, and other high-throughput particle screening tools. Straight channel inertial focusing device design requires knowledge of fluid properties and particle-channel size ratio. Equilibrium behavior of inertially focused particles has been extensively characterized and the constitutive phenomena described by scaling relationships for straight channels of square and rectangular cross section. In concentrated particle suspensions, however, long-range hydrodynamic repulsions give rise to complex particle ordering that, while interesting and potentially useful, can also dramatically diminish the technique’s effectiveness for high-throughput particle handling applications. We have empirically investigated particle focusing behavior within channels of increasing aspect ratio and have identified three scaling regimes that produce varying degrees of geometrical ordering between focused particles. To explore the limits of inertial particle focusing and identify the origins of these long-range interparticle forces, we have explored equilibrium focusing behavior as a function of channel geometry and particle concentration. Experimental results for highly concentrated particle solutions identify equilibrium thresholds for focusing that scale weakly with concentration and strongly with channel geometry. Balancing geometry mediated inertial forces with estimates for interparticle repulsive forces now provide a complete picture of pattern formation among concentrated inertially focused particles and enhance our understanding of the fundamental limits of inertial focusing for technological applications.

42 ENGINEERING↗