Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy and crystallography define carotenoid oxygenases as a new subclass of mononuclear non-heme Fe II enzymes

Carotenoid cleavage dioxygenases (CCDs) are non-heme Fe II enzymes that catalyze the oxidative cleavage of alkene bonds in carotenoids, stilbenoids, and related compounds. How these enzymes control the reaction of dioxygen (O 2 ) with their alkene substrates is unclear. Here, we apply spectroscopy in conjunction with X-ray crystallography to define the iron coordination geometry of a model CCD, CAO1 (Neurospora crassa carotenoid oxygenase 1), in its resting state and following substrate binding and coordination sphere substitutions. Resting CAO1 exhibits a five-coordinate (5C), square pyramidal Fe II center that undergoes steric distortion toward a trigonal bipyramidal geometry in the presence of piceatannol. Titrations with the O 2 -analog, nitric oxide, show a >100-fold increase in iron–nitric oxide affinity upon substrate binding, defining a crucial role for the substrate in activating the Fe II site for O 2 reactivity. The importance of the 5C Fe II structure for reactivity was probed through mutagenesis of the second-sphere Thr151 residue of CAO1, which occludes ligand binding at the sixth coordination position. A T151G substitution resulted in the conversion of the iron center to a six-coordinate state and a 135-fold reduction in apparent catalytic efficiency toward piceatannol compared with the wildtype enzyme. Substrate complexation resulted in partial six-coordinate to 5C conversion, indicating solvent dissociation from the iron center. Additional substitutions at this site demonstrated a general functional importance of the occluding residue within the CCD superfamily. Taken together, these data suggest an ordered mechanism of CCD catalysis occurring via substrate-promoted solvent replacement by O 2 . CCDs thus represent a new class of mononuclear non-heme Fe II enzymes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of (1.39±0.11)×10^{-5} e^{-}/pix/day, corresponding to (39.8±3.1) e^{-}/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the wavelength range between near-infrared and ultraviolet. We use these data to obtain a 90% confidence level upper bound of 1.53×10^{-5} e^{-}/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

dark matter↗

Charge-trap analysis in a SENSEI skipper-CCD: Understanding low-energy backgrounds in rare-event searches

Skipper charge-coupled devices (CCDs) are ultralow-threshold detectors capable of detecting energy deposits in silicon at the electronvolt scale. Skipper CCDs are increasingly used in rare-event searches, including experiments such as SENSEI, DAMIC-M, Oscura, and CONNIE, where one of the major challenges is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we use the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly, but more work is needed to assess the impact of the traps that cannot be characterized.

Brusco, Agustin↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

DarkNESS: developing a skipper-CCD instrument to search for Dark Matter from Low Earth Orbit

The DarkNESS (Dark Matter Nano-satellite Equipped with Skipper Sensors) mission aims to deploy a skipper-CCD CubeSat Observatory to search for dark matter (DM) from Low Earth Orbit. This mission will employ novel skipper-CCDs to investigate O(keV) X-rays from decaying DM, as well as electron recoils from strongly-interacting sub-GeV DM. The DarkNESS mission will be the first space deployment of skipper-CCDs, and the DarkNESS team is developing a skipper-CCD instrument that is compatible with the CubeSat platform. DarkNESS has recently progressed from laboratory validation to a Critical Design Review (CDR) phase, with a launch opportunity anticipated in late 2025. The implementation of the DarkNESS skipper-CCD payload on the CubeSat platform will pave the way for future demonstrators of space-based imagers for X-ray and single-electron counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DarkNESS: A skipper-CCD nanosatellite for dark matter searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace’s DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). As a result, this will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

Alpine, Phoenix [University of Illinois, Urbana-Ch↗

Two-dimensional burn velocity and analysis of burn products of nitromethane at high pressure

We have studied the laser-initiated deflagration of nitromethane (CH 3 NO 2 ) under high static pressure in the diamond anvil cell. Time-resolved images of the deflagrations have been obtained using intensified CCDs (ICCD). In contrast with previous work, we rely on spontaneous emission from the reaction, rather than changes in the speckle pattern produced by artificial illumination of the sample. Furthermore, as opposed to the 1D records obtained previously with streak cameras, ICCDs permit imaging of the burn in two dimensions providing the ability to directly observe anisotropic deflagration behavior. Here, we report several examples of this behavior and discuss its possible origins. We have also investigated the products of the reaction using Raman spectroscopy. At pressures below 25 GPa, the burn product is observed to be opaque and has a Raman spectrum consistent with a carbonaceous soot. At pressures above 25 GPa, the burn product is observed to be transparent (consistent with earlier reports) and its Raman spectrum reveals the presence of molecular N 2 and a nitrogen-carbonate species. The latter species can be recovered to ambient pressure and has a Raman spectrum consistent with ammonium carbonate or ammonium bicarbonate. To aid interpretation of the Raman spectra, measurements have also been made on the isotopologues CH 3 15 NO 2 and 13 CH 3 NO 2 . This work establishes the importance of advanced time-resolved imaging to reveal the details of deflagration under high pressure and further advances our understanding of the corresponding chemistry.

Deflagration↗

Balmer emission measurements in JET-ILW hydrogen, deuterium, tritium and deuterium-tritium low-confinement mode plasmas

Measurements of Balmer-alpha (B-α) and Balmer-gamma (B-γ), where B = H, D, or T isotopes of hydrogen, emission across the low-field side (LFS) divertor in JET ITER-like Wall (ILW), low-confinement mode (L-mode) plasma indicate that the divertor plasma was more strongly detached in deuterium, tritium and deuterium–tritium than in hydrogen plasmas. These measurements are consistent with the lower degree of detachment in hydrogen versus tritium plasmas inferred from Langmuir probes (Groth et al., 2023). The ratio of B-γ to B-α is a suitable indicator of high density/low temperature conditions because B-α emission is dominated by electron impact excitation with a small electron–ion recombination component regardless of electron temperature and density (for conditions in tokamak plasmas) whilst for B-γ the recombination component increases and the excitation component decreases as the electron temperature decreases and the electron density increases. Within the uncertainty of the measurements, the electron density at the low-field side separatrix and the power crossing the separatrix are similar to permit these comparisons. The B-©/B-α ratio is well correlated with the onset of detachment as measured by Langmuir probes (McCracken et al., 1998; Groth et al., 2023). The ratios of B-γ and B-α varied between 0.005 and 0.035 for low-recycling, high-recycling and partially detached conditions, and were 60–70 % higher in partially detached hydrogen than in tritium plasmas. In contrast, the difference between deuterium, tritium and 40–60 % deuterium–tritium is within 10 % and thus within the uncertainties of the measurements. Profiles of the B-α and B-γ emission was measured with two filtered CCDs connected to the visible lost light leg of JET’s mirror link spectroscopy system (Meigs et al., 2010; Lomanowski et al., 2014). Spatially (radial) narrower B-α profiles were measured with increasing isotope mass, while similarly broadened B-γ profiles were measured.

Balmer↗

The La Silla Schmidt Southern Survey

We present the La Silla Schmidt Southern Survey (LS4), a new wide-field, time-domain survey to be conducted with the 1 m ESO Schmidt telescope. The 268 megapixel LS4 camera mosaics 32 2k × 4k fully depleted CCDs, providing a ∼20 deg 2 field of view with 1″ pixel −1 resolution. The LS4 camera will have excellent performance at longer wavelengths: in a standard 45 s exposure the expected 5σ limiting magnitudes in g, i, z are ∼21.5, ∼20.9, and ∼20.3 mag (AB), respectively. The telescope design requires a novel filter holder that fixes different bandpasses over each quadrant of the detector. Two quadrants will have i band, while the other two will be g and z band with color information obtained by dithering targets across the different quadrants. The majority (90%) of the observing time will be used to conduct a public survey that monitors the extragalactic sky at both moderate (3 days) and high (1 day) cadence, as well as focused observations within the Galactic plane and bulge. Alerts from the public survey will be broadcast to the community via established alert brokers. LS4 will run concurrently with the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST). The combination of LS4+LSST will enable detailed holistic monitoring of many nearby transients: high-cadence LS4 observations will resolve the initial rise and peak of the light curve while less-frequent but deeper observations by LSST will characterize the years before and after explosion. Here, we summarize the primary science objectives of LS4 including microlensing events in the Galaxy, extragalactic transients powered by massive black holes or stellar explosions, the search for electromagnetic counterparts to multi-messenger events, and supernova cosmology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-sided charge-coupled devices

Existing charge-coupled devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. Here, we propose an imager, the dual-sided CCD, which collects and measures both charge carriers on opposite sides of the device via a dual-buried channel architecture. We show that this dual detection strategy provides exceptional dark-count rejection and enhanced timing capabilities. These advancements have wide-ranging implications for dark-matter searches, near-infrared/optical spectroscopy, and time-domain x-ray astrophysics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Direct-Detection Results on Sub-GeV Dark Matter Using the SENSEI Detector at SNOLAB

Here, we present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4–10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our “hot-pixel” mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Skipper-CCD Light Shield for X-Ray Detection in Space

We present advancements in the design of Skipper-CCD sensors for X-ray detection in environments with high optical backgrounds, such as those expected in space. These packages incorporate a custom-made aluminum shield on the CCD surface that blocks over 99% of visible light while preserving the efficiency for keV X-rays. These features allow us to perform precise X-ray measurements in environments challenged by visible light interference. Furthermore, we briefly discuss the potential implementation of this design concept in frame-transfer CCDs, opening opportunities for broader applications and advancements in imaging technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robotic Assembly of Multi-Chip Modules Using Artificial Intelligence

With many properties of dark matter remaining a mystery, the OSCURA experiment aims to detect light dark matter particles using 1,536 Multi-Chip Modules (MCMs), containing a total of 24,576 skipper CCDs. Currently, each MCM is assembled by hand a time-consuming and error-prone process that can be automated. In this ongoing work, we present an automated assembly robot that leverages modern computer vision and artificial intelligence to assemble the OSCURA MCMs. This approach reduces cost, time, and error in the packaging of OSCURA sensors.

Arteaga, Matthew [Northern Illinois U.; Fermilab]↗

Novel Light Detectors for Directional MeV scale DM Detectors

The search for sub-GeV dark matter requires novel detector development due to the small expected ionization signal and large backgrounds, many of which still need to be well-modeled. For this reason, to unambiguously detect dark matter, a detector must be able to determine the directionality of the incoming particles so that the daily modulation of the rate can be used to confirm a dark matter signal. This can be accomplished by combining anisotropic scintillating crystals, such as trans-Stilbene, as a detector target, with an optically-sensitive Skipper CCD as a readout. I will present on my work over the past six months developing the first prototype of this detector, including optical testing of the trans-Stilbene and design of the detector. This work will lead to characterization of the CCDs and deployment of the first prototype later this year.

Hoch, Nora [MIT]↗