Recent progress in photoelectron image detection with CCDs

Intensified CCDs (ICCDs) were built and operated. These ICCDs were electrostatically and magnetically-focussed image tubes which use CCDs as anodes. The ICCDs detected single photoelectrons, and have electron gain very near that which was predicted. The first single-pixel pulse-height distributions were presented, and the leakage current was shown to increase as a function of photoelectron irradiation. The advantages and disadvantages of front- and rear-illuminated designs were discussed in light of differing applications requirements.

Choisser, J. P.

The use of CCDs in the Space Telescope Imaging Spectrograph (STIS)

The present study describes the STIS instrument concept and the role and requirements of the CCD detectors. Specific required properties and the current status of the efforts to meet them are discussed. The goals of the STIS team include studies of the origin and evolution of the solar system, star formation, variable stellar phenomena, the nature and energy balance of the interstellar and intergalactic medium, and the origin and evolution of galaxies and their nuclear activity. The STIS operating modes (spectral range, resolving power, effective area, and angular range) and the optical arrangement to accomplish them are presented. The detective quantum efficiency of several candidate detector types are shown as a function of wavelength for the four STIS bands. Difficulties that arise in the use of CCDs are discussed. Consideration is given to the requirements imposed on STIS CCDs and to their performance.

Woodgate, Bruce E.

Quantum efficiency measurements of Tektronix backside thinned CCDs

Results are presented of a program in progress to produce CCDs with high stable quantum efficiency (QE). Measurements made at 253.7 nm over a six-month period showed no significant QE difference between two CCDs manufactured in 1989 and one manufactured in 1988. QE improvement by the addition of a two-layer antireflection coating is about threefold at 400 nm.

Delamere, Alan

Managing Radiation Degradation of CCDs on the Chandra X-ray Observatory

The CCDs on the Chandra X ray Observatory are sensitive to radiation damage particularly from low-energy protons scattering off the telescope's mirrors onto the focal plane. In its highly elliptical orbit, Chandra passes through a spatially and temporally varying radiation environment, ranging from the radiation belts to the solar wind. Translating thc Advanced CCD Imaging Spectrometer (ACIS) out of the focal position during radiation-belt passages has prevented loss of scientific utility and eventually functionality. However, carefully managing the radiation damage during the remainder of the orbit, without unnecessarily sacrificing observing time, is essential to optimizing the scientific value of this exceptional observatory throughout its planned 10-year mission. In working toward this optimization, the Chandra team developed aid applied radiation-management strategies. These strategies include autonomous instrument safing triggered by the on-board radiation monitor, as well as monitoring, alerts, and intervention based upon real-time space-environment data from NOAA and NASA spacecraft. Furthermore, because Chandra often spends much of its orbit out of the solar wind (in the Earth's outer magnetosphere and magnetosheath), the team developed the Chandra Radiation Model to describe the complete low-energy-proton environment. Management of the radiation damage has thus far succeeded in limiting degradation of the charge-transfer inefficiency (CTI) to less than 4.4*10^-6 and 1.4*10^-6 per year for the front-illuminated and back-illuminated CCDs, respectively.

ODell, Stephen L.

Comparison of the Proton-Induced Dark Current and Charge Transfer Efficiency Responses of N- and P-Channel CCDs

The proton-induced CTE behavior for the Lawrence Berkeley National Laboratory (LBNL) p-CCD (being developed for the Supernovae Acceleration Project (SNAP) and Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) n-CCDs were compared using 55Fe, EPER and FPR techniques. CTE performance of the p-CCD is about an order of magnitude better after a 63 MeV fluence of 2.5 x 10(sup 9)/sq cm, which is equivalent to 2.5 years in the shielded HST orbit. Notched n- and p-CCDs yielded factor of two improvement in CTE performance as compared to their un-notched versions. The introduction rate of hot pixels was greater in p-CCD as compared to n-CCD, and also greater in notched than un-notched devices.

Marshall, Cheryl

Chemical Thinning Process for Fabricating UV-Imaging CCDs

The thinning stage of the postfabrication process reported in the immediately preceding article is notable in its own right. Although the thinning process was described in the preceding article as part of an overall process of fabrication of a supported charge-coupled device (CCD), it is more generally applicable to both free-standing and supported devices that have been fabricated in die and wafer formats. Like the thermocompression bonding process described in the preceding article, the thinning process is compatible with CCD-fabrication processes, as well as postfabrication processes that enhance the response of CCDs to ultraviolet (UV) light, including the delta-doping process. CCDs that are thinned by this process and then delta-doped exhibit high quantum efficiencies that are stable with time and with exposure to the environment.

Jones, TOdd

Delta-Doped CCDs for Enhanced UV Performance

Thin, backside-illuminated CCds are modified by growing a delta-doped silicon layer on the back surface using molecular beam epitaxy. Delta-doped CCDs exhibit stable and uniform 100 percent internal quantum efficiency. The process consists of growth of an epitaxial silicon layer on a fully-processed commercial CCd die in which 30 percent of a monolayer of boron atoms are incorporated into the lattice nominally in a single atomic layer. Long term stability was tested and showed no degradation of the device quantum efficiency over sixteen months.

silicon

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]

Electron-Induced Displacement Damage Effects in CCDs

We compare differences in parametric degradation for CCDs irradiated to the same displacement damage dose with 10-MeV and 50-MeV electrons. Charge transfer efficiency degradation was observed to not scale with NIEL for small signals.

Juno Mission

Sandbox CCDs

Seven new CCDs are presented. The devices will be used in a variety of applications ranging

Sandbox

Low-Energy Electron Detection with Delta-Doped CCDs

In this paper, we will briefly discuss delta-doped CCDs and their application of low-energy electron detection. We show that modification of the surface this way can greatly improve sensitivity to low energy electrons.

electron

Studying single-electron traps in newly fabricated Skipper-CCDs for the Oscura experiment using the pocket-pumping technique

Understanding and characterizing very low-energy (⁠ ∼eV) background sources is a must in rare-event searches. Oscura, an experiment aiming to probe electron recoils from sub-GeV dark matter using a 10 kg skipper-CCD detector, has recently fabricated its first two batches of sensors. In this work, we present the characterization of defects/contaminants identified in the buried-channel region of these newly fabricated skipper-CCDs. These defects/contaminants produce deferred charge from trap emission in the images next to particle tracks, which can be spatially resolved due to the sub-electron resolution achieved with these sensors. Using the trap-pumping technique, we measured the energy and cross section associated with these traps in three Oscura prototype sensors from different fabrication batches which underwent different gettering methods during fabrication. Results suggest that the type of defects/contaminants is more closely linked to the fabrication batch rather than to the gettering method used. The exposure-dependent single-electron rate (SER) of one of these sensors was measured ∼100 m underground, yielding (1.8±0.3)×10−3e−/pix/day at 131 K. The impact of the identified traps on the measured exposure-dependent SER is evaluated via a Monte Carlo simulation. Results suggest that the exposure-dependent SER of Oscura prototype sensors would be lower in lower background environments as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Low Activity Tritium Detection in CCDs Using Deep Learning Techniques

Here, this study explores the use of charge-coupled devices (CCDs) for detecting low-energy beta particles from tritium decay - a critical signal for nuclear safety, nuclear nonproliferation, and environmental monitoring. We employ a dual approach utilizing both measured CCD data and detailed Geant4 simulations. Our analysis compares classical techniques with advanced deep learning methods, including convolutional neural networks (CNNs), autoencoders trained exclusively on tritium data, and preliminary studies on boosted decision trees (BDTs). The CNN, trained on mixed signal/background datasets, demonstrates superior classification performance, while the autoencoder shows the potential of unsupervised, background-agnostic strategies when background characteristics are poorly defined. These results highlight the excellent sensitivity achievable thanks to the background rejection made possible by information-rich CCD data, paving the way for improved portable tritium monitoring.

Autoencoder

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS

Spectral analysis using CCDs

Charge-coupled devices (CCDs) are ideally suited for performing sampled-data transversal filtering operations in the analog domain. Two algorithms have been identified for performing spectral analysis in which the bulk of the computation can be performed in a CCD transversal filter; the chirp z-transform and the prime transform. CCD implementation of both these transform algorithms is presented together with performance data and applications.

Hewes, C. R.

Present and future CCDs for UV and X-ray scientific measurements

Interacting quantum efficiencies in excess of 50 percent have been demonstrated with CCDs throughout the spectral range 600-9,00 A, and comparable sensitivity is expected to continue to wavelengths as short as a few Angstroms. Nondispersive X-ray spectra throughout the 250-8000 V range have been obtained with an FWHM spectral resolution of 200-250 eV. At present, however, both spectral and spatial resolution is limited at some energies by the diffusion of photogenerated charge into more than one picture element. Progress in reducing charge diffusion is reported, with particular attention given to a theoretical diffusion model and its implications for further improvement.

Janesick, J. R.

CCDs at Lick Observatory

Improved sensitivity to light and uniformity of response has been obtained using various surface treatments of thinned CCDs. Procedures are described and some results are shown. The Lick Observatory data acquisition system is briefly described. A new thermoelectrically-cooled CCD camera for telescope guiding has been designed and built. The camera is described and preliminary results at the telescope are given.

Robinson, Lloyd B.