Cathodochromic cathode ray tube: An operations manual

A cathodochromic (CC) storage and display system capable of storing full TV resolution images has been built. The images are derived from standard TV signals: composite video, composite sync, composite blanking, horizontal drive, and vertical drive. Image storage takes place in the CC CRT; the fixed image is written for several TV frames for the contrast to be usable. Once stored on the CC CRT, the image can be read out in one of three modes: with the eye, a 35-mm camera, or a TV camera. Incoming information may also be stored in a storage tube similar to the CC CRT but with a phosphor layer behind the CC layer. By exciting the phosphor layer with a standard raster scan it is possible to read out an image stored in the CC layer in one of three modes: direct viewing, photography, or flying-spot readout using a photomultiplier.

Heyman, P. M.↗

Z-axis control loop for cathode-ray tubes

Inexpensive PIN diode detector samples screen brightness between camera frames generating error signal for feedback control of intensity. System was tested by taking flat-field exposures at several density levels over 4 hour period. Results showed processed film density levels varied by less than + or - 10 percent usually centering around + or - 8 percent.

Ray, A. J., Jr.↗

Effect of cursor characteristics on pilots' tracking performance on a cathode-ray tube in dynamic simulation

The effects of cursor configuration, size, and orientation on the performance of 11 commercial airline pilots were investigated in a difficult compensatory tracking task in a moving-base aircraft simulator. Three levels of congruent cab motion (0, 1, and 2 times the visual motion) were superimposed on the tracking task. Data analysis of the mean tracking error scores revealed no significant effects of cursor size, orientation, or configuration on pilots' tracking performance. Mean tracking error did not significantly differ between the three levels of motion for the conditions with a single dot as the cursor. However, for the dotted and solid line cursors, tracking error significantly decreased from the no motion condition to the motion conditions. The addition of simulator motion significantly reduced tracking error for large cursors, but not for small ones such as a single dot

Junge, M. K.↗

Biomedical ultrasonoscope

The combination of a "C" mode scan electronics in a portable, battery powered biomedical ultrasonoscope having "A" and "M" mode scan electronics, the latter including a clock generator for generating clock pulses, a cathode ray tube having X, Y and Z axis inputs, a sweep generator connected between the clock generator and the X axis input of the cathode ray tube for generating a cathode ray sweep signal synchronized by the clock pulses, and a receiver adapted to be connected to the Z axis input of the cathode ray tube. The "C" mode scan electronics comprises a plurality of transducer elements arranged in a row and adapted to be positioned on the skin of the patient's body for converting a pulsed electrical signal to a pulsed ultrasonic signal, radiating the ultrasonic signal into the patient's body, picking up the echoes reflected from interfaces in the patient's body and converting the echoes to electrical signals; a plurality of transmitters, each transmitter being coupled to a respective transducer for transmitting a pulsed electrical signal thereto and for transmitting the converted electrical echo signals directly to the receiver, a sequencer connected between the clock generator and the plurality of transmitters and responsive to the clock pulses for firing the transmitters in cyclic order; and a staircase voltage generator connected between the clock generator and the Y axis input of the cathode ray tube for generating a staircase voltage having steps synchronized by the clock pulses.

Lee, R. D.↗

Display system

A situational display and a means for creating the display are disclosed. The display comprises a moving line or raster, on a cathode ray tube, which is disposed intermediate of two columns of lamps or intensifications on the cathode ray tube. The raster and lights are controlled in such a manner that pairs of lights define a line which is either tracked or chased by the raster in accordance with the relationship between the optimum and actual values of a monitored parameter.

Story, A. W.↗

Apollo display system

Apollo display system permitting display of printed information and charts of real time data on cathode ray tube

Real time↗

Ultrasonic scanner for footprint identification

Scanner includes transducer, acoustical drive, acoustical receiver, X and Y position indicators, and cathode-ray tube. Transducer sends ultrasonic pulses into shoe sole or shoeprint. Reflected signals are picked up by acoustic receiver and fed to cathode-ray tube. Resulting display intensity is directly proportional to reflected signal magnitude.

Derr, L. J.↗

A Low Cost Traveling Wave Tube for Wireless Communications

Demand for high data rate wireless communications is pushing up amplifier power, bandwidth and frequency requirements. Some systems are using vacuum electron devices again because solid-state power amplifiers are not able to efficiently meet the new requirements. The traveling wave tube is the VED of choice because of its excellent broadband capability as well as high power efficiency and frequency. But TWTs are very expensive on a per watt basis below about 200 watts of output power. We propose a new traveling wave tube that utilizes cathode ray tube construction technology and electrostatic focusing. We believe the tube can be built in quantity for under $1,000 each. We discuss several traveling wave tube slow wave circuits that lend themselves to the new construction. We will present modeling results and data on prototype devices.

Vancil, Bernard Kenneth↗

Choice reaction time to movement of eccentric visual targets during concurrent rotary acceleration

This study investigates the influence of concurrent rotary acceleration on choice reaction time (RT) to a small, accelerating visual cursor on a cathode-ray tube. Subjects sat in an enclosed rotating device at the center of rotation and observed a 3-mm dot accelerating at different rates across a cathode-ray tube. The dot was viewed at various eccentricities under conditions of visual stimulation alone and with concurrent rotary acceleration. Subjects responded to both vertical and horizontal dot movements. There was a significant inverse relationship between choice RT and level of dot acceleration (p less than .001), and a significant direct relationship between choice RT and eccentricity (p less than .001). There was no significant difference between choice RT to vertical or horizontal dot motion (p greater than .25), and choice RT was not significantly affected by concurrent rotary acceleration (p greater than .10). The results are discussed in terms of the effects of vestibular stimulation on choice RT to visual motion.

Hamerman, J. A.↗

Fast signal averager

Electron beam of cathode ray tube with fast phosphor is intensity-modulated by input signal to produce repetitive horizontal trace of luminous intensity proportional to time-varying signal strength. Horizontal trace of cathode ray tube occurs so repetitive portion of signal of interest is encompassed within its length.

Cornsweet, T. N.↗

Interactive graphics system for IBM 1800 computer

A FORTRAN compatible software system that has been developed to provide an interactive graphics capability for the IBM 1800 computer is described. The interactive graphics hardware consists of a Hewlett-Packard 1300A cathode ray tube, Sanders photopen, digital to analog converters, pulse counter, and necessary interface. The hardware is available from IBM as several related RPQ's. The software developed permits the application programmer to use IBM 1800 FORTRAN to develop a display on the cathode ray tube which consists of one or more independent units called pictures. The software permits a great deal of flexibility in the manipulation of these pictures and allows the programmer to use the photopen to interact with the displayed data and make decisions based on information returned by the photopen.

Carleton, T. P.↗