Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARBON IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

Physical and Tribological Characteristics of Ion-Implanted Diamond Films

Unidirectional sliding friction experiments were conducted with a natural, polished diamond pin in contact with both as-deposited and carbon-ion-implanted diamond films in ultrahigh vacuum. Diamond films were deposited on silicon, silicon carbide, and silicon nitride by microwave-plasma-assisted chemical vapor deposition. The as-deposited diamond films were impacted with carbon ions at an accelerating energy of 60 keV and a current density of 50 micron A/cm(exp 2) for approximately 6 min, resulting in a dose of 1.2 x 10(exp 17) carbon ions/cm(exp 2). The results indicate that the carbon ion implantation produced a thin surface layer of amorphous, nondiamond carbon. The nondiamond carbon greatly decreased both friction and wear of the diamond films. The coefficients of friction for the carbon-ion-implanted, fine-grain diamond films were less than 0.1, factors of 20 to 30 lower than those for the as-deposited, fine-grain diamond films. The coefficients of friction for the carbon-ion-implanted, coarse-grain diamond films were approximately 0.35, a factor of five lower than those for the as-deposited, coarse-grain diamond films. The wear rates for the carbon-ion-implanted, diamond films were on the order of 10(exp -6) mm(exp 3)/Nm, factors of 30 to 80 lower than that for the as-deposited diamond films, regardless of grain size. The friction of the carbon-ion-implanted diamond films was greatly reduced because the amorphous, nondiamond carbon, which had a low shear strength, was restricted to the surface layers (less than 0.1 micron thick) and because the underlying diamond materials retained their high hardness. In conclusion, the carbon-ion-implanted, fine-grain diamond films can be used effectively as wear resistant, self-lubricating coatings for ceramics, such as silicon nitride and silicon carbide, in ultrahigh vacuum.

Miyoshi, K.↗

Detection of the Carbon Monoxide Ion (CO+) in the Interstellar Medium and a Planetary Nebula

We report detection of the carbon monoxide ion (CO+) in the interstellar medium (Ml7SW) and a planetary nebula (NGC 7027). These detections are based on observations of three millimeter and submillimeter transitions in M17SW and one in NGC 7027. Chemical models suggest that CO+ should be most abundant where complex molecules are least likely to be present. In our search for CO+ we therefore minimized the chance of confusion while maximizing the probability of detection by observing regions whose chemistry is dominated by the effects of ultraviolet radiation.

Latter, William B.↗

Manufacturing of 57cm carbon-carbon composite ion optics for the NEXIS ion engine

Exploration of the outer planets can be taxing on the ion optics of ion propulsion systems because of the higher power and propellant throughout than the present state-of-the art. Carbon-carbon composite ion optics are an enabling technology extending the life of ion optics operated at high specific impulse, power, and propellant throughout because of their low erosion rates compared to molybdenum ion optics.

ion optics manufacturing↗

The 157 Micron (C II) Luminosity of the Galaxy

The diffuse far infrared (C II) emission of several regions of the Galactic plane were sampled. Mechanisms for the excitation of carbon ions are discussed in reference to the role of carbon ion transitions in cooling diffuse atomic hydrogen. Observations indicate that the C II emission probably arises at the edges of giant molecular clouds and appears to have localized knot-like features. The total C II luminosity of the Galaxy is approximately 6 to 10 to the 7th power L(solar).

Stacey, G. J.↗

Evidence for the involvement of carbonic anhydrase and urease in calcium carbonate formation in the gravity-sensing organ of Aplysia californica

To better understand the mechanisms that could modulate the formation of otoconia, calcium carbonate granules in the inner ear of vertebrate species, we examined statoconia formation in the gravity-sensing organ, the statocyst, of the gastropod mollusk Aplysia californica using an in vitro organ culture model. We determined the type of calcium carbonate present in the statoconia and investigated the role of carbonic anhydrase (CA) and urease in regulating statocyst pH as well as the role of protein synthesis and urease in statoconia production and homeostasis in vitro. The type of mineral present in statoconia was found to be aragonitic calcium carbonate. When the CA inhibitor, acetazolamide (AZ), was added to cultures of statocysts, the pH initially (30 min) increased and then decreased. The urease inhibitor, acetohydroxamic acid (AHA), decreased statocyst pH. Simultaneous addition of AZ and AHA caused a decrease in pH. Inhibition of urease activity also reduced total statoconia number, but had no effect on statoconia volume. Inhibition of protein synthesis reduced statoconia production and increased statoconia volume. In a previous study, inhibition of CA was shown to decrease statoconia production. Taken together, these data show that urease and CA play a role in regulating statocyst pH and the formation and maintenance of statoconia. CA produces carbonate ion for calcium carbonate formation and urease neutralizes the acid formed due to CA action, by production of ammonia.

Non-NASA Center↗

Apparatus for producing diamond-like carbon flakes

A vacuum arc from a spot at the face of a graphite cathode to a graphite anode produces a beam of carbon ions and atoms. A carbon coating from this beam is deposited on an ion beam sputtered target to produce diamond-like carbon flakes. A graphite tube encloses the cathode, and electrical isolation is provided by an insulating sleeve. The tube forces the vacuum arc spot to be confined to the surface on the outermost end of the cathode. Without the tube the arc spot will wander to the side of the cathode. This spot movement results in low rates of carbon deposition, and the properties of the deposited flakes are more graphite-like than diamond-like.

Banks, Bruce A.↗

Vapor phase diamond growth technology

Ion beam deposition chambers used for carbon film generation were designed and constructed. Features of the developed equipment include: (1) carbon ion energies down to approx. 50 eV; (2) in suit surface monitoring with HEED; (3) provision for flooding the surface with ultraviolet radiation; (4) infrared laser heating of substrate; (5) residual gas monitoring; (6) provision for several source gases, including diborane for doping studies; and (7) growth from either hydrocarbon source gases or from carbon/argon arc sources. Various analytical techniques for characterization of from carbon/argon arc sources. Various analytical techniques for characterization of the ion deposited carbon films used to establish the nature of the chemical bonding and crystallographic structure of the films are discussed. These include: H2204/HN03 etch; resistance measurements; hardness tests; Fourier transform infrared spectroscopy; scanning auger microscopy; electron spectroscopy for chemical analysis; electron diffraction and energy dispersive X-ray analysis; electron energy loss spectroscopy; density measurements; secondary ion mass spectroscopy; high energy electron diffraction; and electron spin resonance. Results of the tests are summarized.

Angus, J. C.↗

Mechanism for diamond nucleation and growth on single crystal copper surfaces implanted with carbon

The nucleation and growth of diamond crystals on single-crystal copper surfaces implanted with carbon ions is studied. Microwave plasma-enhanced chemical-vapor deposition is used for diamond growth. The single-crystal copper substrates were implanted either at room or elevated temperature with carbon ions prior to diamond nucleation. This procedure leads to the formation of a graphite film on the copper surface which greatly enhances diamond crystallite nucleation. A simple lattice model is constructed for diamond growth on graphite as 111 line (diamond) parallel to 0001 line (graphite) and 110 line (diamond) parallel to 1 1 -2 0 (graphite).

Ong, T. P.↗

Carbon-Based Ion Optics Development at NASA GRC

With recent success of the NSTAR ion thruster on Deep Space 1, there is continued interest in long term, high propellant throughput thrusters to perform energetic missions. This requires flight qualified thrusters that can operate for long periods at high beam density, without degradation in performance resulting from sputter induced grid erosion. Carbon-based materials have shown nearly an order of magnitude improvement in sputter erosion resistance over molybdenum. NASA Glenn Research Center (GRC) has been active over the past several years pursuing carbon-based grid development. In 1995, NASA GRC sponsored work performed by the Jet Propulsion Laboratory to fabricate carbon/carbon composite grids using a machined panel approach. In 1999, a contract was initiated with a commercial vendor to produce carbon/carbon composite grids using a chemical vapor infiltration process. In 2001, NASA GRC purchased pyrolytic carbon grids from a commercial vendor. More recently, a multi-year contract was initiated with North Carolina A&T to develop carbon/carbon composite grids using a resin injection process. The following paper gives a brief overview of these four programs.

Haag, Thomas↗

Complex Chromosomal Rearrangements Induced in Vivo by Heavy Ions

It has been suggested that the ratio complex/simple exchanges can be used as a biomarker of exposure to high-LET radiation. We tested this hypothesis in vivo, by considering data from several studies that measured complex exchanges in peripheral blood from humans exposed to mixed fields of low- and high-LET radiation. In particular, we studied data from astronauts involved in long-term missions in low-Earth-orbit, and uterus cancer patients treated with accelerated carbon ions. Data from two studies of chromosomal aberrations in astronauts used blood samples obtained before and after space flight, and a third study used blood samples from patients before and after radiotherapy course. Similar methods were used in each study, where lymphocytes were stimulated to grow in vitro, and collected after incubation in either colcemid or calyculin A. Slides were painted with whole-chromosome DNA fluorescent probes (FISH), and complex and simple chromosome exchanges in the painted genome were classified separately. Complex-type exchanges were observed at low frequencies in control subjects, and in our test subjects before the treatment. No statistically significant increase in the yield of complex-type exchanges was induced by the space flight. Radiation therapy induced a high fraction of complex exchanges, but no significant differences could be detected between patients treated with accelerated carbon ions or X-rays. Complex chromosomal rearrangements do not represent a practical biomarker of radiation quality in our test subjects. Copyright 2003 S. Karger AG, Basel.

Ions/adverse effects/therapeutic use↗

Dielectronic recombination as a function of electric field strength

Dielectronic recombination (DR) is the dominant recombination mechanism at coronal temperatures and densities. We present a procedure for calculating DR rate coefficients as a function of electric field strength and apply this method to carbon ions. We focus on the competing effects of enhancement by plasma microfields and rate decrease through collisional excitation and ionization. We find that, in the case of C(3+), a significant rate enhancement results, leading to a reinterpretation of C IV emission-line intensities in the sun and late-type stars. We further consider how macroscopic electric fields, in particular motional electric fields, can affect DR rate coefficients, demonstrating dramatic rate increases for a number of the carbon ions.

Reisenfeld, Daniel B.↗

Strangelove Ocean and Deposition of Unusual Shallow-Water Carbonates After the End-Permian Mass Extinction

The severe mass extinction of marine and terrestrial organisms at the end of the Permian Period (approx. 251 Ma) was accompanied by a rapid negative excursion of approx. 3 to 4 per mil in the carbon-isotope ratio of the global surface oceans and atmosphere that persisted for some 500,000 into the Early Triassic. Simulations with an ocean-atmosphere/carbon-cycle model suggest that the isotope excursion can be explained by collapse of ocean primary productivity (a Strangelove Ocean) and changes in the delivery and cycling of carbon in the ocean and on land. Model results also suggest that perturbations of the global carbon cycle resulting from the extinctions led to short-term fluctuations in atmospheric pCO2 and ocean carbonate deposition, and to a long-term (>1 Ma) decrease in sedimentary burial of organic carbon in the Triassic. Deposition of calcium carbonate is a major sink of river-derived ocean alkalinity and for CO2 from the ocean/atmosphere system. The end of the Permian was marked by extinction of most calcium carbonate secreting organisms. Therefore, the reduction of carbonate accumulation made the oceans vulnerable to a build-up of alkalinity and related fluctuations in atmospheric CO2. Our model results suggest that an increase in ocean carbonate-ion concentration should cause increased carbonate accumulation rates in shallow-water settings. After the end-Permian extinctions, early Triassic shallow-water sediments show an abundance of abiogenic and microbial carbonates that removed CaCO3 from the ocean and may have prevented a full 'ocean-alkalinity crisis' from developing.

Rampino, Michael R.↗

Mossbauer effect in the ion-implanted iron-carbon alloys

The concentration dependence of Mossbauer effect in four carbon ion-implanted iron absorbers, which contain carbon as the solute atoms, has been investigated over the range of concentration 0.05 through 1 atomic percent. The specimens were prepared by implanting carbon atoms on each reference iron foil with four different bombarding energies of 250 keV, 160 keV, 140 keV and 80 keV, respectively. Thus, the specimen contains a uniform dosage of carbon atoms which penetrated up to 3,000 A depth of the reference iron. In the measurement of Mossbauer spectra, the backscattering conversion electron counting geometry was used. Typical results of Mossbauer parameters of iron-carbon alloys show that the isomer shift, quadrupole shift, the effective hyperfine splitting of Fe-57, and the intensity ratio exhibit a large variation with the increase of carbon concentration in the environment of iron atoms.

Han, K. S.↗