Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CARBON DIOXIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analyses of the Integration of Carbon Dioxide Removal Assembly, Compressor, Accumulator and Sabatier Carbon Dioxide Reduction Assembly

A tool has been developed by the Sabatier Team for analyzing/optimizing CO2 removal assembly, CO2 compressor size, its operation logic, water generation from Sabatier, utilization of CO2 from crew metabolic output, and Hz from oxygen generation assembly. Tests had been conducted using CDRA/Simulation compressor set-up at MSFC in 2003. Analysis of test data has validated CO2 desorption rate profile, CO2 compressor performance, CO2 recovery and CO2 vacuum vent in CDRA desorption. Optimizing the compressor size and compressor operation logic for an integrated closed air revitalization system Is being conducted by the Sabatier Team.

Jeng, Frank F.

The Headache of Carbon Dioxide Exposures

Carbon dioxide (CO2), a natural product of human metabolism, accumulates quickly in sealed environments when humans are present, and can induce headaches, among other symptoms. Major resources are expended to control CO2 levels to concentrations that are tolerable to the crews of spacecraft and submersible craft. It is not practical to control CO2 levels to those found in the ambient environment on earth. As NASA looks ahead to long-duration missions conducted far from earth, difficult issues arise related to the management and effects of human exposure to CO2. One is the problem of pockets of CO2 in the habitat caused by excess generation of the gas in one location without a mechanism to purge the area with fresh air. This results in the crew rebreathing CO2 from their exhaled breath, exposing them to a much higher concentration of CO2 than whole-module measurements would suggest. Another issue is the potential increased sensitivity to CO2 in microgravity. For example, based on anecdotal information, it appears that space crews may be more susceptible than submarine crews to some of the subtle, yet adverse effects of CO2 exposure. Another issue, not unique to spaceflight, is the possibility of inter-individual differences in the susceptibility of crewmembers to CO2 exposure. Again, anecdotal reports from the International Space Station (ISS) crews suggest that certain individuals may experience a greater susceptibility. The implications associated with these issues are extremely important as NASA sets CO2 exposure limits that protect the crew from this compound s subtle adverse effects, without causing an unwarranted expenditure of resources to scrub CO2 from the habitat atmosphere.

James, John T.

Assessing the Health and Performance Risks of Carbon Dioxide Exposures

Carbon dioxide (CO2) is an anthropogenic gas that accumulates in spacecraft to much higher levels than earth-normal levels. Controlling concentrations of this gas to acceptable levels to ensure crew health and optimal performance demands major commitment of resources. NASA has many decades of experience monitoring and controlling CO2, yet we are uncertain of the levels at which subtle performance decrements develop. There is limited evidence from ground-based studies that visual disturbances can occur during brief exposures and visual changes have been noted in spaceflight crews. These changes may be due to CO2 alone or in combination with other known spaceflight factors such as increased intracranial pressure due to fluid shifts. Discerning the comparative contribution of each to performance decrements is an urgent issue if we hope to optimize astronaut performance aboard the ISS. Long-term, we must know the appropriate control levels for exploration-class missions to ensure that crewmembers can remain cooperative and productive in a highly stressful environment. Furthermore, we must know the magnitude of interindividual variability in susceptibility to the adverse effects of CO2 so that the most tolerant crewmembers can be identified. Ground-based studies have been conducted for many years to set exposure limits for submariners; however, these studies are typically limited and incompletely reported. Nonetheless, NASA, in cooperation with the National Research Council, has set exposure limits for astronauts using this limited database. These studies do not consider the interactions of spaceflight-induced fluid shifts and CO2 exposures. In an attempt to discern whether CO2 levels affect the incidence of headache and visual disturbances in astronauts we performed a retrospective study comparing average CO2 levels and the prevalence of headache and visual disturbances. Our goal is to narrow gaps in the risk profile for in-flight CO2 exposures. Such studies can provide no more than partial answers to the questions of environmental interactions, interindividual variability, and optimal control levels. Future prospective studies should involve assessment of astronaut well being using sophisticated measures during exposures to levels of CO2 in the range from 2 to 8 mmHg.

James, John T.

Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial-off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy so long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C and 1 atm). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0-10.2 PSIA) or spacesuit (4.1-8.0 PSIA), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the basis of the exponential loss in accuracy is developed theoretically considering thermal, Doppler, and Lorentz broadening effects which arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. As a result, this manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application.

Swickrath, Michael J.

Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy as long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C (70.0 F) and 1 atmosphere). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0{10.2 pounds per square inch absolute (psia)) or spacesuit (4.1{8.0 psia), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the source of the exponential loss in accuracy is developed theoretically. The basis of the loss can be explained through thermal, Doppler, and Lorentz broadening effects that arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. This manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application.

Swickrath, Michael J.

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon is capable of recovering all the oxygen from carbon dioxide, and is the only real alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon and the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

Oxygen recovery

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon, is capable of recovering all the oxygen from carbon dioxide, and it is a promising alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon, and the resulting carbon buildup eventually fouls the catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

ECLSS

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50 because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon is capable of recovering all the oxygen from carbon dioxide, and is the only real alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon and the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

Oxygen Recovery

Measuring the Spectral Expression of Carbon Dioxide in the Solar Reflected Spectrum with AVIRIS

Carbon dioxide is a low-concentration, but important, component of the Earth's atmosphere. This gas absorbs electromagnetic radiation (EMR) in several regions of the spectrum. Absorption of energy by carbon dioxide adds heat to the atmosphere. In the world today, the burning of fossil fuels and other anthropogenic processes adds carbon dioxide to the atmosphere. Other natural processes in the Earth's system both add and remove carbon dioxide. Overall, measurements of atmospheric carbon dioxide at selected sites around the globe show an increased carbon dioxide concentration in the atmosphere. A figure shows the measured carbon dioxide from Mauna Loa, Hawaii, from 1958 to 2000. Overall, the concentration has increased from 315 to 365 ppm at this site over this period. (There is also a yearly cycle to the concentration that is timed with and hypothesized to be related to the vegetation growing season in the Northern Hemisphere.) The overall expected effect of this increase of atmospheric carbon dioxide is trapping of heat in the atmosphere and global warming. While this overall relationship between carbon dioxide and global warming seems straightforward, many of the specific details relating to regional and local sources and sinks and gradients of carbon dioxide are not well understood. A remote sensing capability to measure carbon dioxide could provide important inputs for scientific research to better understand the distribution and change in atmospheric carbon dioxide at detailed spatial and temporal levels. In pursuit of this remote sensing of carbon dioxide objective, this paper analyzes the expression of carbon dioxide in the spectral range measured by the Airborne Visible/Infrared Imagery Spectrometer (AVIRIS). Based on these analyses, a spectral-fitting algorithm that uses AVIRIS measured spectra and MODTRAN radiative-transfer code modeled spectra to derive total column carbon dioxide abundance has been developed. This algorithm has been applied to an AVIRIS data set acquired over Pasadena, California, in 1999 and a data set acquired over the Pacific Ocean near Hawaii in 2000 with promising results. This is ongoing research; the current initial analyses, measurements, and results are reported in this paper.

Green, Robert O.

A high-pressure carbon dioxide gasdynamic laser

A carbon dioxide gasdynamic laser was operated over a range of reservoir pressure and temperature, test-gas mixture, and nozzle geometry. A significant result is the dominant influence of nozzle geometry on laser power at high pressure. High reservoir pressure can be effectively utilized to increase laser power if nozzle geometry is chosen to efficiently freeze the test gas. Maximum power density increased from 3.3 W/cu cm of optical cavity volume for an inefficient nozzle to 83.4 W/cu cm at 115 atm for a more efficient nozzle. Variation in the composition of the test gas also caused large changes in laser power output. Most notable is the influence of the catalyst (helium or water vapor) that was used to depopulate the lower vibrational state of the carbon dioxide. Water caused an extreme deterioration of laser power at high pressure (100 atm), whereas, at low pressure the laser for the two catalysts approached similar values. It appears that at high pressure the depopulation of the upper laser level of the carbon dioxide by the water predominates over the lower state depopulation, thus destroying the inversion.

Kuehn, D. M.

Improvements in Ionic Liquid Technology for Carbon Dioxide Removal Applications

Carbon dioxide removal from cabin air continues to be of vital importance for future space missions. Current and proposed approaches have employed solid sorbents, hollow fiber membrane separators, and direct liquid sorbent contactors. Recent developments in ionic liquids have potential to improve performance in all three of these technologies. Efficient encapsulation of ionic liquids by polymeric shell can enable their use in a solid sorbent-like configuration without significant integration intervention to the current space technology. Poly(ionic liquid)-ionic liquid membranes have the potential to cross over the Robeson selectivity-permeability upper bound, and thereby outperform traditional membranes used in hollow fibers. Advances in ionic liquid chemistry enables performance improvements in liquid sorbent contactors owing to the tunable gravimetric CO2 capacity, reaction enthalpy and liquid viscosity. This paper will describe recent work in each of these areas.

Ionic Liquid,Carbon Dioxide,Air Revitalization

Measuring Atmospheric Carbon Dioxide from the NASA Orbiting Carbon Observatory-2 (OCO-2)

Fossil fuel combustion, deforestation, and other human activities are now adding almost 40 billion tons of carbon dioxide (CO2) to the atmosphere each year. These emissions are superimposed on an active natural carbon cycle that adds about 20 times as much CO2 to the atmosphere annually, and then reabsorbs a comparable amount, along with over half of the CO2 contributed by human activities. Interestingly, the identity and location of the natural “sinks” in the land biosphere and ocean that are responsible for absorbing this anthropogenic CO2 are still poorly understood. Because of this, it is impossible to accurately predict how these sinks will respond to a warming climate. Space based remote sensing provides new tools for studying the sources and sinks of CO2. The NASA Orbiting Carbon Observatory-2 (OCO-2) was launched in July 2014 and was inserted at the head of the 705-km Afternoon Constellation (A-Train) a month later.

Crisp, David

Carbon Dioxide Removal via Passive Thermal Approaches

A paper describes a regenerable approach to separate carbon dioxide from other cabin gases by means of cooling until the carbon dioxide forms carbon dioxide ice on the walls of the physical device. Currently, NASA space vehicles remove carbon dioxide by reaction with lithium hydroxide (LiOH) or by adsorption to an amine, a zeolite, or other sorbent. Use of lithium hydroxide, though reliable and well-understood, requires significant mass for all but the shortest missions in the form of lithium hydroxide pellets, because the reaction of carbon dioxide with lithium hydroxide is essentially irreversible. This approach is regenerable, uses less power than other historical approaches, and it is almost entirely passive, so it is more economical to operate and potentially maintenance- free for long-duration missions. In carbon dioxide removal mode, this approach passes a bone-dry stream of crew cabin atmospheric gas through a metal channel in thermal contact with a radiator. The radiator is pointed to reject thermal loads only to space. Within the channel, the working stream is cooled to the sublimation temperature of carbon dioxide at the prevailing cabin pressure, leading to formation of carbon dioxide ice on the channel walls. After a prescribed time or accumulation of carbon dioxide ice, for regeneration of the device, the channel is closed off from the crew cabin and the carbon dioxide ice is sublimed and either vented to the environment or accumulated for recovery of oxygen in a fully regenerative life support system.

Lawson, Michael