Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A comparative study of surface energies and water adsorption on Ce-bastnäsite, La-bastnäsite, and calcite via density functional theory and water adsorption calorimetry

Bastnäsite, a fluoro-carbonate mineral, is the single largest mineral source of light rare earth elements (REE), La, Ce and Nd. Enhancing the efficiency of separation of the mineral from gangue through froth flotation is the first step towards meeting an ever increasing demand for REE. To design and evaluate collector molecules that selectively bind to bastnäsite, a fundamental understanding of the structure and surface properties of bastnäsite is essential. In our earlier work (J Phys Chem C, 2016, 120, 16767), we carried out an extensive study of the structure, surface stability and water adsorption energies of La-bastnäsite. Here in this work, we make a comparative study of the surface properties of Ce-bastnäsite, La-bastnäsite, and calcite using a combination of density functional theory (DFT) and water adsorption calorimetry. Spin polarized DFT+U calculations show that the exchange interaction between the electrons in Ce 4f orbitals is negligible and that these orbitals do not participate in bonding with the oxygen atom of the adsorbed water molecule. In agreement with calorimetry, DFT calculations predict larger surface energies and stronger water adsorption energies on Ce-bastnäsite than on La-bastnäsite. The order of stabilities for stoichiometric surfaces is as follows: [100] > [101] > [102] > [0001] > [112] > [104] and the most favorable adsorption sites for water molecules are the same as for La-bastnäsite. In agreement with water adsorption calorimetry, at low coverage water molecules are strongly stabilized via coordination to the surface Ce3+ ions, whereas at higher coverage they are adsorbed less strongly via hydrogen bonding interaction with the surface anions. Lastly, due to similar water adsorption energies on bastnäsite [101] and calcite [104] surfaces, the design of collector molecules that selectively bind to bastnäsite over calcite must exploit the structural differences in the predominantly exposed facets of these minerals.

36 MATERIALS SCIENCE↗

AC calorimetry of H 2 O at pressures up to 9 GPa in diamond anvil cells

If successfully developed, calorimetry at tens of GPa of pressure could help characterize phase transitions in materials such as high-pressure minerals, metals, and molecular solids. In this paper, we extend alternating-current calorimetry to 9 GPa and 300 K in a diamond anvil cell and use it to study phase transitions in H 2 O. In particular, water is loaded into the sample chambers of diamond-cells, along with thin metal heaters (1 μm-thick platinum or 20 nm-thick gold on a glass substrate) that drive high-frequency temperature oscillations (20 Hz to 600 kHz; 1 to 10 K). The heaters also act as thermometers via the third-harmonic technique, yielding calorimetric data on (1) heat conduction to the diamonds and (2) heat transport into substrate and sample. Using this method during temperature cycles from 300 to 200 K, we document melting, freezing, and proton ordering and disordering transitions of H 2 O at 0 to 9 GPa, and characterize changes in thermal conductivity and heat capacity across these transitions. Finally, the technique and analysis pave the way for calorimetry experiments on any non-metal at pressures up to ~100 GPa, provided a thin layer (several μm-thick) of thermal insulation supports a metallic thin-film (tens of nm thick) Joule-heater attached to low contact resistance leads inside the sample chamber of a diamond-cell.

36 MATERIALS SCIENCE↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5–50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of σ/E≃9.3%/E⊕1.3% is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N≃30, for example, the energy resolution for electrons below 40 MeV is improved by ≈10%, ≈20%, and ≈40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The joys and jitters of high‐temperature calorimetry

Abstract High‐temperature calorimetry (HTC) originated in the 20th century as a niche method to enable measurements not easily accomplished with acid solution calorimetry, combustion calorimetry, vapor pressure, or EMF methods. Over time, HTC has evolved into a versatile approach to accurately quantify formation, phase transition, surface and interfacial enthalpies of a wide range of materials including minerals and refractory inorganic compounds. This evolution has been the result of numerous adjustments to experimental setups and procedures, followed by rigorous testing. The commercial availability and the scientific success of this technique have led to an increase in the number of laboratories applying HTC. However, the knowledge acquired by researchers over the past 70 years is scattered throughout the literature or only available as laboratory internal documentation and personal experience. This publication is a collaborative effort among several leading HTC laboratories to summarize and unify current state‐of‐the‐art HTC techniques and procedures. The text starts by summarizing various HT techniques that are commonly used for readers with an interest in HTC in general. It is then directed toward HTC users and includes a brief section on data evaluation procedures as well as a comprehensive compilation of reference data utilizing molten sodium molybdate and lead borate solvents. Finally, for experienced HTC users, an in‐depth discussion of some common difficulties and a discussion of uncertainties are presented.

Scharrer, Manuel [Navrotsky Eyring Center for Mate↗

Determining processing behaviour of pure Cu in laser powder bed fusion using direct micro-calorimetry

We report copper is challenging to process by laser powder bed fusion (LPBF) given its high reflectivity at common infrared laser diode wavelengths and high thermal conductivity. Successful deposition of copper in a predictable and repeatable fashion relies on understanding the development of the keyhole melting regime, as well as heating, melting, boiling and vapour formation behaviour when interacting with a laser beam within an LPBF environment. In this study, in situ optical absorptivity measurements are used to clarify the complex physics of the laser material interaction. Absorptivity of laser energy is measured using direct micro-calorimetry and compared to melt pool depth in correlation to processing parameters. The measured absorptivity for a 100 μm layer thickness of powder was found to be approximately four times higher than that of the bare polished discs. It was also shown that high laser power above 500 W and scan speed up to 150 mm/s are appropriate for effective melting of the powder layer, with these parameters overcoming the threshold required to achieve keyhole melting. This is explained by multiple reflections withing the powder particles and the lower thermal conductivity of packed powder in comparison to bare discs. Melt pool formation was found to be highly unstable and an explosive behavior was observed when in the keyhole regime, caused by high fluctuations in absorptivity values. This work demonstrates calorimetry can be used to monitor melting behaviour in a real-time fashion during processing for this challenging to process material, thereby avoiding unnecessary parametric optimisation. In addition, the parametric window for optimum processing revealed here can inform future work.

36 MATERIALS SCIENCE↗

Calorimetry can detect the early onset of hydrolysis in hybrid supercapacitors with aqueous electrolytes

This study investigates the effect of cation species on the onset of electrolyte hydrolysis in hybrid supercapacitors with aqueous electrolytes using isothermal operando calorimetry. The cells consisted of a positive α-MnO 2 cryptomelane electrode and a negative activated carbon (AC) electrode with either 0.5 M K 2 SO 4 or 0.5 M Cs 2 SO 4 aqueous electrolytes. They were characterized using cyclic voltammetry and galvanostatic cycling. In addition, the instantaneous heat generation rate at each electrode was measured using a custom isothermal operando calorimeter. Heat generation associated with resistive losses (Joule heating) and reversible ion adsorption/desorption was clearly identified. For larger potential windows, an endothermic dip, attributed to the onset of hydrolysis, was observed at the positive α-MnO 2 electrode where K + and Cs + ions engaged in fast surface redox reactions. Interestingly, this endothermic dip appeared at 1.8 V and 2.0 V for K 2 SO 4 and Cs 2 SO 4 aqueous electrolytes, respectively. The difference in the stable operating potential window was attributed to thinner solvation shell around Cs + cation than for K + thus reducing the amount of water present near the electrodes as ions partially shed their solvation shells during adsorption. The early onset of hydrolysis could be observed by isothermal operando calorimetry before it could be observed with conventional electrochemical methods.

42 ENGINEERING↗

Adsorption calorimetry during metal vapor deposition on single crystal surfaces: Increased flux, reduced optical radiation, and real-time flux and reflectivity measurements

Thin films of metals and other materials are often grown by physical vapor deposition. To understand such processes, it is desirable to measure the adsorption energy of the deposited species as the film grows, especially when grown on single crystal substrates where the structure of the adsorbed species, evolving interface, and thin film are more homogeneous and well-defined in structure. Our group previously described in this journal an adsorption calorimeter capable of such measurements on single-crystal surfaces under the clean conditions of ultrahigh vacuum [J. T. Stuckless, N. A. Frei, and C. T. Campbell, Rev. Sci. Instrum. 69, 2427 (1998)]. Here we describe several improvements to that original design that allow for heat measurements with ∼18-fold smaller standard deviation, greater absolute accuracy in energy calibration, and, most importantly, measurements of the adsorption of lower vapor-pressure materials which would have previously been impossible. These improvements are accomplished by: (1) using an electron beam evaporator instead of a Knudsen cell to generate the metal vapor at the source of the pulsed atomic beam, (2) changing the atomic beam design to decrease the relative amount of optical radiation that accompanies evaporation, (3) adding an off-axis quartz crystal microbalance for real-time measurement of the flux of the atomic beam during calorimetry experiments, and (4) adding capabilities for in situ relative diffuse optical reflectivity determinations (necessary for heat signal calibration). These improvements are not limited to adsorption calorimetry during metal deposition, but also could be applied to better study film growth of other elements and even molecular adsorbates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetics of solid-gas reactions characterized by scanning AC nano-calorimetry with application to Zr oxidation

Scanning AC nano-calorimetry is a recently developed experimental technique capable of measuring the heat capacity of thin-film samples of a material over a wide range of temperatures and heating rates. Here, we describe how this technique can be used to study solid-gas phase reactions by measuring the change in heat capacity of a sample during reaction. We apply this approach to evaluate the oxidation kinetics of thin-film samples of zirconium in air. The results confirm parabolic oxidation kinetics with an activation energy of 0.59 ± 0.03 eV. The nano-calorimetry measurements were performed using a device that contains an array of micromachined nano-calorimeter sensors in an architecture designed for combinatorial studies. We demonstrate that the oxidation kinetics can be quantified using a single sample, thus enabling high-throughput mapping of the composition-dependence of the reaction rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-D-BRC-06: Experimental and Monte Carlo Studies of Fluence Corrections for Graphite Calorimetry in Proton Therapy

Purpose: For photon and electron beams, the standard device used to measure absorbed dose is a calorimeter. Standards laboratories are currently working on the establishment of graphite calorimeters as a primary standard for proton beams. To provide a practical method for graphite calorimetry, it is necessary to convert dose to graphite to dose to water, requiring knowledge of the water-to-graphite stopping-power ratio and the fluence correction factor. This study aims to present a novel method to determine fluence corrections experimentally, and to apply this methodology to low- and high-energy proton beams. Methods: Measurements were performed in 60 MeV and 180 MeV proton beams. Experimental information was obtained from depth-dose ionization chamber measurements performed in a water phantom. This was repeated with different thicknesses of graphite plates in front of the water phantom. One distinct advantage of this method is that only ionization chamber perturbation factors for water are required. Fluence corrections were also obtained through Monte Carlo simulations for comparison with the experiments. Results: The experimental observations made in this study confirm the Monte Carlo results. Overall, fluence corrections between water and graphite increased with depth, with a maximum correction of 1% for the low-energy beam and 4% for the high-energy beam. The results also showed that a fraction of the secondary particles generated in proton therapy beams do not have enough energy to cross the ionization chamber wall; thus, their contribution is not accounted for in the measured fluence corrections. This effect shows up as a discrepancy in fluence corrections of 1% and has been confirmed by simulations of the experimental setup. Conclusion: Fluence corrections derived by experiment do not account for low-energy secondary particles that are stopped in the ion chamber wall. This work will contribute to a practical graphite calorimetry technique for determining absolute dose to water in proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 09: Stability of a water calorimetry system as a primary standard for absorbed dose to water

Purpose: To investigate the stability of a water calorimetry system as a primary standard for absorbed dose to water using measurements performed in cobalt-60 and high-energy linac photon beams over a span of more than a decade. Methods: Calorimetry measures adsorbed dose directly by recording the amount of heat created when ionizing radiation passes through matter. The radiation-induced temperature rise was measured using two thermistors calibrated against the NRC temperature primary standard, using an AC bridge with lock-in amplifier for precise measurement. The calorimeter system was operated under thermal equilibrium at 4 °C (to eliminate convection) with drifts in water temperature less than 0.1 mK/min. Seven water vessels of various designs were used to make repeated measurements over the course of 17 years. Results: The standard uncertainty achieved for a set of ten calorimeter measurements (4 Gy delivered) was generally well below 0.15 % while the variation between multiple sets for a given vessel was consistent with this value. The long-term stability of the system combined with inter-vessel variations indicated that there was good control of the radiochemistry (chemical heat defect). Conclusions: The measurements performed over a period of several years showed that the combined water calorimeters showed stability at +/− 0.25 % level. Thus, rather than relying on a particular vessel as an artifact one can realize the Gray through the more generalized method of combining a glass vessel, high-purity water and thermistor probes. This provides increased robustness in the dissemination of absorbed dose to Canadian users.

60 APPLIED LIFE SCIENCES↗

Applying fast calorimetry analysis on spent fuel calorimeter - 15620

Swedish Nuclear Fuel and Waste Management Company (SKB) is responsible for the back-end of the Swedish nuclear industry. This includes transport of spent fuel by boat from the power plants to the Central Interim Storage Facility for Spent Fuel (Clab), and in the future, encapsulation of the spent fuel and further transportation to a geological repository. In order to ensure safety for the planned geological repository, the decay heat has to be well known. For this purpose the SKB has performed calorimetric measurements on over 200 pressurized water reactor (PWR) and boiling water reactor (BWR) assemblies since 2003. The results from earlier analyses have been used to improve computer codes predicting heat as well as to acquire deeper knowledge about the fuel inventory. The work complements research being done as part of the Next Generation of Safeguards Initiative - Spent Fuel project, whose purpose is to develop and test nondestructive assay (NDA) technologies to improve safeguards measurements of spent nuclear fuel. The project is working to accomplish multiple goals, one of which is to determine the heat content of spent fuel assemblies. To shorten the measurement time, the temperature increase method was used instead of the equilibrium temperature method. In the temperature increase method, the temperature inside of the calorimeter is lowered below the surrounding water temperature before the measurement, and the temperature is allowed to increase due to the higher surrounding water temperature during the measurement. The rate of the temperature increase when the temperature is the same as the surrounding temperature is then compared to a calibration curve where an electric heater has been used in the same way. The price for the higher throughput is less accuracy and dependency of fuel geometry since the heat flow will be different for different fuel types, especially between PWR and BWR assemblies. Recently at Los Alamos National Laboratory, more sophisticated analysis methods have been considered for the use of calorimetry for treaty verification. These methods aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy and eliminate the dependency on fuel geometry. Even though the techniques show promise for future calorimetry of spent fuel, certain design features of the current system have been identified to interfere with the accuracy of equilibrium measurements in general such as changing pool temperatures and heat leakage during calibration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting the heat release variability of Li-ion cells under thermal runaway with few or no calorimetry data

Accurate measurement of the variability of thermal runaway behavior of lithium-ion cells is critical for designing safe battery systems. However, experimentally determining such variability is challenging, expensive, and time-consuming. Here, we utilize a transfer learning approach to accurately estimate the variability of heat output during thermal runaway using only ejected mass measurements and cell metadata, leveraging 139 calorimetry measurements on commercial lithium-ion cells available from the open-access Battery Failure Databank. We show that the distribution of heat output, including outliers, can be predicted accurately and with high confidence for new cell types using just 0 to 5 calorimetry measurements by leveraging behaviors learned from the Battery Failure Databank. Fractional heat ejection from the positive vent, cell body, and negative vent are also accurately predicted. We demonstrate that by using low cost and fast measurements, we can predict the variability in thermal behaviors of cells, thus accelerating critical safety characterization efforts.

25 ENERGY STORAGE↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The importance of calorimetry for highly-boosted jet substructure

Jet substructure techniques are playing an essential role in exploring the TeV scale at the Large Hadron Collider (LHC), since they facilitate the efficient reconstruction and identification of highly-boosted objects. Both for the LHC and for future colliders, there is a growing interest in using jet substructure methods based only on charged-particle information. The reason is that silicon-based tracking detectors offer excellent granularity and precise vertexing, which can improve the angular resolution on highly-collimated jets and mitigate the impact of pileup. In this paper, we assess how much jet substructure performance degrades by using track-only information, and we demonstrate physics contexts in which calorimetry is most beneficial. Specifically, we consider five different hadronic final states—W bosons, Z bosons, top quarks, light quarks, gluons—and test the pairwise discrimination power with a multi-variate combination of substructure observables. In the idealized case of perfect reconstruction, we quantify the loss in discrimination performance when using just charged particles compared to using all detected particles. We also consider the intermediate case of using charged particles plus photons, which provides valuable information about neutral pions. In the more realistic case of a segmented calorimeter, we assess the potential performance gains from improving calorimeter granularity and resolution, comparing a CMS-like detector to more ambitious future detector concepts. Broadly speaking, we find large performance gains from neutral-particle information and from improved calorimetry in cases where jet mass resolution drives the discrimination power, whereas the gains are more modest if an absolute mass scale calibration is not required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigating the Role of Energy Density in Thermal Runaway of Lithium-Ion Batteries with Accelerating Rate Calorimetry

This work uses accelerating rate calorimetry to evaluate the impact of cell chemistry, state of charge, cell capacity, and ultimately cell energy density on the total energy release and peak heating rates observed during thermal runaway of Li-ion batteries. While the traditional focus has been using calorimetry to compare different chemistries in cells of similar sizes, this work seeks to better understand how applicable small cell data is to understand the thermal runaway behavior of large cells as well as determine if thermal runaway behaviors can be more generally tied to aspects of lithium-ion cells such as total stored energy and specific energy. We have found a strong linear correlation between the total enthalpy of the thermal runaway process and the stored energy of the cell, apparently independent of cell size and state of charge. We have also shown that peak heating rates and peak temperatures reached during thermal runaway events are more closely tied to specific energy, increasing exponentially in the case of peak heating rates.

25 ENERGY STORAGE↗

A Demonstration of Light-Augmented Calorimetry For Low-Energy Electrons in Liquid Argon.

The ability to resolve electrons with energies as low as 5 MeV in liquid argon (LAr) is important for future studies of astrophysical neutrinos in liquid argon time projection chambers (LArTPCs). Existing methods for measuring the energy of electromagnetic showers in LArTPCs rely solely on charge-based reconstruction which requires correcting for assumed electron-ion recombination. However, LAr scintillation light has the potential to improve energy reconstruction over charge-based measurements alone. Here we present a demonstration of a light-augmented calorimetric technique for low-energy electrons in LAr that foregoes the need to correct for recombination. A sample of Michel electrons from stopping cosmic muons is collected in LArIAT (Liquid Argon In A Testbeam), a single-phase LArTPC at Fermilab’s Test Beam Facility. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons with Ee < 60 MeV is then simulated to better determine the energy resolution of this topology. Due to LArIAT’s low wire noise, the addition of light is not found to significantly improve upon the achieved charged-based resolution of σ/E ≃ 9%/√E ⊕ 1%. However, additional samples are generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in large LArTPCs such as DUNE and SBND. At a charge-readout signal-to-noise of ≈10, the energy resolution for low-energy electrons is improved by ∼15%, ∼25%, and ∼45% over charge-only calorimetry for average light yields of 10, 20, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADiCAL—Precision Timing, Ultracompact, Radiation-Hard Electromagnetic Calorimetry

To address the challenges of providing high-performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCC-hh environments), we conducted R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we focused our attention on ultra-compact radiation-hard EM calorimeters based on modular structures (RADiCAL modules) consisting of alternating layers of the very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.

Anderson, Thomas↗