Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bragg spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Crystallography of low Z material at ultrahigh pressure: Case study on solid hydrogen

Diamond anvil cell techniques have been improved to allow access to the multimegabar ultrahigh-pressure region for exploring novel phenomena in condensed matter. However, the only way to determine crystal structures of materials above 100 GPa, namely, X-ray diffraction (XRD), especially for low Z materials, remains nontrivial in the ultrahigh-pressure region, even with the availability of brilliant synchrotron X-ray sources. In this work,we perform a systematic study, choosing hydrogen (the lowest X-ray scatterer) as the subject, to understand how to better perform XRD measurements of low Z materials at multimegabar pressures. The techniques that we have developed have been proved to be effective in measuring the crystal structure of solid hydrogen up to 254 GPa at room temperature [C. Ji et al.,Nature 573, 558–562 (2019)]. We present our discoveries and experiences with regard to several aspects of this work, namely, diamond anvil selection, sample configuration for ultrahigh-pressure XRD studies,XRD diagnostics for low Z materials, and related issues in data interpretation and pressure calibration.We believe that these methods can be readily extended to other low Z materials and can pave the way for studying the crystal structure of hydrogen at higher pressures, eventually testing structural models of metallic hydrogen.

36 MATERIALS SCIENCE↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Coherent diffractive imaging with twisted X-rays: Principles, applications, and outlook

Recent technological breakthroughs in synchrotron and x-ray free electron laser facilities have revolutionized nanoscale structural and dynamic analyses in condensed matter systems. This review provides a comprehensive overview of the advancements in coherent scattering and diffractive imaging techniques, which are now at the forefront of exploring materials science complexities. These techniques, notably Bragg coherent diffractive imaging and x-ray photon correlation spectroscopy, x-ray magnetic dichroism, and x-ray correlation analysis leverage beam coherence to achieve volumetric three-dimensional imaging at unprecedented sub-nanometer resolutions and explore dynamic phenomena within sub-millisecond timeframes. Such capabilities are critical in understanding and developing advanced materials and technologies. Simultaneously, the emergence of chiral crystals—characterized by their unique absence of standard inversion, mirror, or other roto-inversion symmetries—presents both challenges and opportunities. These materials exhibit distinctive interactions with light, leading to phenomena such as molecular optical activity, chiral photonic waveguides, and valley-specific light emissions, which are pivotal in the burgeoning fields of photonic and spintronic devices. This review elucidates how novel x-ray probes can be leveraged to unravel these properties and their implications for future technological applications. A significant focus of this review is the exploration of new avenues in research, particularly the shift from conventional methods to more innovative approaches in studying these chiral materials. Inspired by structured optical beams, the potential of coherent scattering techniques utilizing twisted x-ray beams is examined. This promising direction not only offers higher spatial resolution but also opens the door to previously unattainable insights in materials science. By contextualizing these advancements within the broader scientific landscape and highlighting their practical applications, this review aims to chart a course for future research in this rapidly evolving field.

Physics↗

In situ coherent x-ray scattering reveals polycrystalline structure and discrete annealing events in strongly coupled nanocrystal superlattices

Solution-phase bottom up self-assembly of nanocrystals into superstructures such as ordered superlattices is an attractive strategy to generate functional materials of increasing complexity, including very recent advances that incorporate strong interparticle electronic coupling. While the self-assembly kinetics in these systems have been elucidated and related to the product characteristics, the weak interparticle bonding interactions suggest the superstructures formed could continue to order within the solution long after the primary nucleation and growth have occurred, even though the mechanism of annealing remains to be elucidated. Here, we use a combination of Bragg coherent diffractive imaging and x-ray photon correlation spectroscopy to create real-space maps of supercrystalline order along with a real-time view of the strain fluctuations in aging strongly coupled nanocrystal superlattices while they remain suspended and immobilized in solution. By combining the results, we deduce that the self-assembled superstructures are polycrystalline, initially comprising multiple nucleation sites, and that shear avalanches at grain boundaries continue to increase crystallinity long after growth has substantially slowed. This multimodal approach should be generalizable to characterize a breadth of materials in their native chemical environments, thus extending the reach of high-resolution coherent x-ray characterization to the benefit of a much wider range of physical systems. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

Feasibility of using distributed chemical sensing for CO2 leakage monitoring

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CCS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed using optical spectroscopy in optical fiber for direct detection of CO 2 . The main approach is based on Raman interrogation within gas-filled Holey Fibers (HoFs), so that the location and concentration of the gases would be provided simultaneously via backscattering. Additionally, Infrared (IR) Absorption Spectroscopy could also be used, and the architecture would be more discrete since interleaving with standard solid core fibers and Fiber Bragg Grating (FBG) sections is required to enable reflection to the I/O controls. The possible Raman length or the IR numbers of sections would be defined based on signal to noise ratio. The optical spectroscopy methodology would overcome current roadblocks to CCS, as fiber optics will allow for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Discerning element and site-specific fluctuations of the charge-orbital order in Fe 3 O 4 below the Verwey transition

Despite countless experimental probes into magnetite's electronic structure across the Verwey transition Fe 3 O 4 , the exact origin of this archetypical metal-insulator transition remains a puzzle. Advanced x-ray diffraction techniques have mostly resolved the monoclinic structure of the insulating phase, including interatomic bond lengths, but the complexity of the charge-orbitally ordered state is difficult to disentangle. Here we combined resonant elastic x-ray scattering and x-ray photon correlation spectroscopy to probe charge-orbital fluctuations in the insulating state of magnetite. By accessing the Bragg forbidden $(00\frac{1}{2})_{c}$ peak at the oxygen K-edge, we complement our previous study on the iron L 3 – edge to reveal the dynamics of the iron 3d and oxygen 2p orbital domains. Our new results reveal a decoupling of the orbital correlation lengths between the oxygen 2p states and site-specific iron 3d states, and we further show charge-orbital domain fluctuations at the iron t 2g orbital sites of trimeron chains. These results also demonstrate an experimental method capable of distinguishing electronic dynamics between the oxygen ligands and the transition metal that underpins emergent behaviors in complex oxides.

36 MATERIALS SCIENCE↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong, Yet Split Hydrogen Bonding with Ice Rules in Delafossite (H/D)RhO 2

Despite remaining enigmatic, strong hydrogen bonding provides an advanced design handle for tailoring the properties of functional materials. Here, in this study, 3 R –(H/D)RhO 2 delafossites (prepared by ion exchange of Na + from NaRhO 2 ) contain H/D in linear coordination with O, linking Rh III O 2 layers. Bragg and real-space X-ray and neutron scattering analysis, vibrational and solid-state NMR spectroscopy, and density functional theory (DFT)–based electronic structure calculations have been employed to understand the nature of the hydrogen bonding. Despite short distances between H/D and the two O to which they are bonded, a clear double-minimum corresponding to a shorter and longer (H/D)–O distance is established. The triangular lattices formed by H/D appear to display ice-like disorder, corroborated by low-temperature heat capacity measurements.

NMR spectroscopy↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Diffraction gratings with two-orders-of-magnitude-enhanced dispersion rates for sub-meV resolution soft X-ray spectroscopy

Diffraction gratings with large angular dispersion rates are central to obtaining high spectral resolution in grating spectrometers operating over a broad spectral range from infrared to soft X-ray domains. The greatest challenge is of course to achieve large dispersion rates in the short-wavelength X-ray domain. Here it is shown that crystals in non-coplanar asymmetric X-ray Bragg diffraction can function as high-reflectance broadband soft X-ray diffraction gratings with dispersion rates that are at least two orders of magnitude larger than those that are possible with state-of-the-art man-made gratings. Additionally, this opens new opportunities to design and implement soft X-ray resonant inelastic scattering (RIXS) spectrometers with spectral resolutions that are up to two orders of magnitude higher than what is currently possible, to further advance a very dynamic field of RIXS spectroscopy, and to make it competitive with inelastic neutron scattering. Examples of large-dispersion-rate crystal diffraction gratings operating near the 930 eV L 3 absorption edge in Cu and of the 2.838 keV L 3 -edge in Ru are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying electron temperature distributions from time-integrated x-ray emission spectra

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. Here we present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of $1310^{+90}_{-70}$ eV with significant contributions from temperatures down to 200 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Scanning X-Ray Diffraction Microscopy for Diamond Quantum Sensing

An understanding of nano- and microscale crystal strain in chemical-vapor-deposition diamond is crucial to the advancement of diamond quantum technologies. In particular, the presence of such strain and its characterization presents a challenge to diamond-based quantum sensing and information applications-as well as for future dark-matter detectors, where the directional information about incoming particles is encoded in crystal strain. Here, we exploit nanofocused scanning x-ray diffraction microscopy to quantitatively measure crystal deformation from defects in diamond with high spatial and strain resolution. The combination of information from multiple Bragg angles allows stereoscopic three-dimensional modeling of strain-feature geometry; the diffraction results are validated via comparison to optical measurements of the strain tensor based on spin-state-dependent spectroscopy of ensembles of nitrogen-vacancy centers in the diamond. Finally, our results demonstrate both strain and spatial resolution sufficient for directional detection of dark matter via x-ray measurement of crystal strain and provide a promising tool for diamond growth analysis and improvement of defect-based sensing.

42 ENGINEERING↗

Polariton Control of Molecular Charge Transfer in Perylene Diimide Semiconductors

We report the modulation of molecular charge transfer in a bay-substituted perylene diimide derivative embedded in a planar distributed Bragg reflector microcavity. Angle-resolved reflectance spectra confirm the formation of upper and lower polaritons with clear Rabi splitting, indicating strong coupling between the cavity mode and molecular excitons. Using broadband transient absorption spectroscopy, we compare the ultrafast dynamics of cavity and non-cavity films. While excited-state absorption and stimulated emission pathways remain largely unchanged, kinetic modeling reveals a moderate increase in the charge transfer rate and yield under strong coupling. This enhancement is attributed to a reduction in the effective driving force via the formation of the lower polariton, placing the system deeper into the Marcus inverted regime. Our results demonstrate a promising non-chemical method leveraging cavity quantum electrodynamics to modulate charge separation processes in molecular semiconductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗