Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bragg crystal spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Si XIII and Si XIV line emission search with the ANS crystal spectrometer

The final results of the search for Si XIII and Si XIV line emission, using the ANS Bragg crystal spectrometer, are presented. No positive line detection was achieved in any of the measurements made on several types of cosmic object; i.e., a transient X-ray source, close binary systems, supernova remnants, GX sources, and clusters of galaxies. Three-sigma upper limits for discrete line emission from these objects are reported and compared with line strengths inferred from other proportional-counter and Bragg spectrometer data. The present upper limit of 1.0 eV for the equivalent width of a narrow Si XIV line emission from the X-ray nova A0620-00 is an order of magnitude lower than previous limits set by other experiments.

Parsignault, D. R.↗

A soft X-ray spectrometer for diffuse cosmic sources

The design of a Bragg crystal spectrometer for the diffuse soft X-ray background is described. The instrument has no moving parts; a 6 degree x 20 degree FWHM field of view; resolution in the range 20-100; and spans wavelength ranges 44-80 A or 13-23 A when lead stearate or KAP crystals are used. If placed on a small spacecraft, integration times of approximately 1000 s will be required to detect the existence of the stronger lines expected in the X-ray background.

Borken, R. J.↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Advanced X-ray Astrophysics Facility (AXAF) science instrumentation

AXAF is to be equipped with a high performance X-ray telescope for the conduction of detailed astrophysics research. The observatory is to be serviced by the Space Station or the Shuttle, depending on capabilities during the AXAF operational period. The AXAF is to utilize the wavelength band from 1.2 A to 120 A. Attention is given to the AXAF science team, the AXAF observatory characteristics, the AXAF science instrument definition program, the Advanced Charge Coupled Device (CCD) Imaging Spectrometer (ACIS), the High Resolution Camera (HRC), the Bragg Crystal Spectrometer (BCS), the X-ray Spectrometer (XRS), the transmission gratings, and the program schedule.

Dailey, C. C.↗

A Bragg spectrometer for stellar X-ray astronomy.

Poor energy resolution and the steeply varying continuum spectrum make it impossible to obtain with proportional counters an unambiguous identification of certain emission features of Sco X-1. For this reason a Bragg crystal spectrometer was constructed. The instrument, flown successfully aboard an Aerobee-170 rocket, scanned the spectral range from 2.4 to 2.9 keV. The spectrometer consists of two large reflecting crystals of synthetic graphite. The results obtained during the flight of the instrument clearly indicate that the Bragg method can yield much higher sensitivity to line emission than can proportional counter methods.

Kestenbaum, H.↗

The curved crystal X-ray spectrometer for the HEAO-B satellite

The Focal Plane Crystal Spectrometer on HEAO-B is a moderate to high resolution, curved-crystal, Bragg spectrometer which operates behind a grazing incidence X-ray telescope. It is designed to allow detailed spectral studies of both point and extended celestial X-ray sources in the energy range 0.2-3.3 keV, with resolutions of 50 to 1000. The analyzing elements are six torroidal diffractors, and the detectors are position-sensitive, flow, proportional counters. HEAO-B is scheduled for launch in June, 1978.

Canizares, C. R.↗

Data reduction and analysis for the graphite crystal X-ray spectrometer and polarimeter experiment flown aboard OSO-8 spacecraft

The documentation and software programs developed for the reception, initial processing (quickbook), and production analysis of data obtained by solar X-ray spectroscopy, stellar spectroscopy, and X-ray polarimetry experiments on OSO-8 are listed. The effectiveness and sensitivity of the Bragg crystal scattering instruments used are assessed. The polarization data polarimetric data obtained shows that some X-ray sources are polarized and that a larger polarimeter of this type is required to perform the measurements necessary to fully understand the physics of X-ray sources. The scanning Bragg crystal spectrometer was ideally suited for studying rapidly changing solar conditions. Observations of the Crab Nebula and pulsar, Cyg X-1, Cyg X-2, Cyg X-3, Sco X-1, Cen X-3, and Her X-1 are discussed as well as of 4U1656-53 and 4U1820-30. Evidence was obtained for iron line emission from Cyg X-3.

Novick, R.↗

Development of improved higher-order correction for the NIF opacity spectrometer

X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. Furthermore, by modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.

79 ASTRONOMY AND ASTROPHYSICS↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of Ultra-High Energy Density Relativistic Plasmas from Ordered Nanostructures

This award funded a four-year program at Colorado State University on the physics of ultra-high energy density plasmas generated by focusing femtosecond, >1021 Wcm-2 laser pulses onto ordered nanowire arrays. We used the ALEPH petawatt-class Ti:Sa laser with its high contrast 400 nm second harmonic beamline to irradiate arrays of Ni and TiO2 nanowires made by template assisted electrodeposition and atomic layer deposition over a wide range of average densities. We met two of the three original project goals: radial ion acceleration via doppler shifted K shell emission, and time and spectrally resolved K shell measurements. The main experimental advance was integrating the Lawrence Livermore National Laboratory (LLNL) TREX ultrafast x-ray streak camera with a suite of spherically bent quartz Bragg crystal spectrometers built using Princeton Plasma Physics Laboratory (PPPL) methodology. This is the first TREX-on-bent-quartz setup fielded at a femtosecond, >1021 Wcm-2 facility. It is now a permanent diagnostic at ALEPH and is offered to the LaserNetUS user community. The program produced three peer reviewed journal articles that acknowledge this award. The platform will continue at the upgraded CSU ATLAS facility, where the ALEPH laser is being upgraded to 2 PW.

Hollinger, Reed [Colorado State University]↗

HEAO-B X-ray experiments. Non-dispersive spectroscopy

The scientific objectives of HEAO-B are presented. They include four X-ray and gamma ray experiments in addition to two charged cosmic ray experiments. The first X-ray experiment is one using standard proportional counters, mechanically collimated, and covers the region from 0.2 to 60 keV. It is being designed for the purpose of detecting small changes in the surface brightness of the X-ray sky over a very broad spectral range. The second X-ray experiment involves Bragg crystal spectrometers for the range 0.5 to 10 keV. In the low energy gamma ray experiment, which also extends into the X-ray region, a cooled germanium (lithium drifted) gamma-ray spectrometer was used.

Boldt, E. A.↗

Multidisciplinary research in the space sciences. Scope B: Experimental X-ray astronomy

A research program to design and develop instruments suitable for rocket-borne X-ray astronomy experiments is discussed. Successful designs that were implemented are summarized. The designs include the following: (1) a large area modular X-ray focusing system, (2) incoherent scattering polarimeters, (3) Bragg crystal spectrometers and polarimeters, and (4) a focusing collector for long wavelength. The applications of these instruments to the observation of X-ray sources in rocket-borne experiments are analyzed.

Novick, R.↗

Observation of soft X-rays from extended sources

Efforts were directed toward surveying several supernova remnants for the emission of soft X-rays. Rather than attempt to detect such faint X-ray emission, the program was redirected to observe the spectrum and angular structure of the extended X-ray source in the Perseus cluster of galaxies and the super-nova remnant Puppis A. An attempt was made to detect X-ray line emission from Puppis A with a Bragg crystal spectrometer. Observations provide evidence for the presence of X-ray line emission in the spectrum of Puppis A near .65 keV.

Catura, R. C.↗

The relative abundance of neon and magnesium in the solar corona

A technique is proposed for specifically determining the relative solar coronal abundance of neon and magnesium. The relative abundance is calculated directly from the relative intensity of the resonance lines of Ne X (12.134A) and Mg XI (9.169A) without the need for the development of a detailed model of the thermal structure of the corona. Moderate resolution Bragg crystal spectrometer results from the OVI-10 satellite were used to determine a coronal neon to magnesium relative abundance of 1.47 + or - 0.38. The application of this technique to a recent higher resolution rocket observation gave an abundance ratio of approximately 0.93 + or - 0.15.

Rugge, H. R.↗

X-ray spectroscopy with the ANS satellite

Preliminary results from the Bragg crystal spectrometer on the ANS satellite are given. No significant Si XIII and Si XIV narrow line emission has been detected from Cygnus X-1, -2, or -3.

Schnopper, H. W.↗

Measurements of the frequency spectrum of transition radiation

We report a measurement of the frequency spectrum of X-ray transition radiation. X rays were generated by electrons of 5 and 9 GeV in radiators of multiple polypropylene foils, and detected in the range 4 to 30 keV with a calibrated single-crystal Bragg spectrometer. The experimental results closely reproduce the features of the theoretically predicted spectrum. In particular, the pronounced interference pattern of multifoil radiators and the expected hardening of the radiation with increasing foil thickness are clearly observed. The overall intensity of the radiation is somewhat lower than predicted by calculations.

Cherry, M. L.↗