Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Birefringent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multichannel birefringent filter

A birefringent filter with a large field of view and no additional polarization is discussed. It plays an important role in observing the solar monochromatic image and the solar vector magnetic field. It has only one channel. For simultaneous multichannel observations, the solar spectrograph is better than the birefringent filter. A suggestion was proposed to try to obtain a multichannel birefringent filter which will be used in a new telescope at the Huairou reservoir station of Beijing Observatory. By means of N polarizing beam splitters, (N+1) channels can be divided. In principle, any number of limitless channels can be obtained, thereby subdividing the whole solar spectrum. But since the space in a telescope is limited, the channels to be used are also limited. For the new telescope, 5 and 9 channels are being considered, and the spectral range is from lambda 3800A to lambda 7000A. Many lines are included in this range, for example, H, K, H beta, lambda lambda 5324A, 5250A, 6302A, H alpha, etc., and some of the lines are suited to measure solar velocity fields. According to the character of these lines, the half width of each channel is determined. Moreover, in some channels the solid polarizing Michelson interferometer is considered for measuring velocity field with a lm/s accuracy. The advantages of the filter and problems to be solved are listed.

Gouxiang, A.

Birefringent-Filter Model

Birefringent Filter Model computer program implements stand-alone mathematical model of birefringent filter for use in design and analysis of birefringent filter. Developed to aid in design of solid-state lasers used on aircraft or spacecraft in remote sensing of atmosphere. General enough to enable user to address such problems as temperature-stability requirements, manufacturing tolerances, and alignment tolerances. Written in Microsoft FORTRAN 2.0.

Cross, Patricia L.

Spectral contents readout of birefringent sensor

The technical objective of this research program was to develop a birefringent sensor, capable of measuring strain/stress up to 2000 F and a readout system based on Spectral Contents analysis. As a result of the research work, a data acquisition system was developed, capable of measuring strain birefringence in a sensor at 2000 F, with multi-point static and dynamic capabilities. The system uses a dedicated spectral analyzer for evaluation of stress-birefringence and a PC-based readout. Several sensor methods were evaluated. Fused silica was found most satisfactory. In the final evaluation, measurements were performed up to 2000 F and the system performance exceeded expectations.

Redner, Alex S.

Measurement of birefringence of optical materials using a wedged plate interferometer

A nondestructive technique for measuring the birefringence of optical materials such as calcite using wedged plate interferometer is presented. The sample needed for measuring the refractive index must be polished in the form of a parallel plate. The method is based on the measurement of the longitudinal displacement of the focus when the parallel plate is inserted in a converging beam of light. The displacement of the focus is a measure of the refractive index of the optical material. In the case of a uniaxial crystal, the displacement of the focus for the extraordinary ray is different from the displacement of the focus for the ordinary ray. Hence the birefringence of the crystal is determined by measuring the difference between the two focii. It is possible to obtain an accuracy up to 0.0002 in the measurement of birefringence depending on the sample thickness. The method should find its application for the characterization of new crystals in various material research and crystal growth laboratories.

Shukla, R. P.

Digital Beam Steering Device Based on Decoupled Birefringent Prism Deflector and Polarization Rotator

We describe digital beam deflectors (DBDs) based on liquid crystals. Each stage of the device comprises a polarization rotator and a birefringent prism deflector. The birefringent prism deflects the beam by an angle that depends on polarization of the incident beam. The prism can be made of the uniaxial smectic A (SmA) liquid crystal (LC) or a solid crystal such as yttrium orthovanadate (YVO4). SmA prisms have high birefringence and can be constructed in a variety of shapes, including single prisms and prismatic blazed gratings of different angles and profiles. We address the challenges of uniform alignment of SmA, such as elimination of focal conic domains. Rotation of linear polarization is achieved by an electrically switched twisted nematic (TN) cell. A DBD composed of N rotator-deflector pairs steers the beam into 2(sup N) directions. As an example, we describe a four-stage DBD deflecting normally incident laser beam within the range of +/- 56 mrad with 8 mrad steps. Redirection of the beam is achieved by switching the TN cells.

Pishnyak, Oleg

Optical temperature sensor utilizing birefringent crystals

A temperature sensor comprising an optical transducer member having an array of birefringent crystals. The length and, accordingly, the sensitivity to temperature change of successive birefringent crystals varies according to a particular relationship. The transducer is interconnected with a fiber optic transmission and detecting system. Respective optical output signals that are transmitted from the birefringent crystals via the fiber optic transmission system are detected and decoded so as to correspond to digits of a numbering system, whereby an accurate digital representation of temperature can ultimately be provided.

Quick, William H.

Detecting strain in birefringent materials using spectral polarimetry

A method, computer program product and system for analyzing multispectral images from a plurality of regions of birefringent material, such as a polymer film, using polarized light and a corresponding polar analyzer to identify differential strain in the birefringent material. For example, the birefringement material may be low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene, polyethylene terephthalate (PET), polyvinyl chloride (PVC), polyvinylidene chloride, polyester, nylon, or cellophane film. Optionally, the method includes generating a real-time quantitative strain map.

Ragucci, Anthony J.

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background

Defect passivation in nanostructured silica for stable birefringence in polarization optics

Nanostructured materials with anisotropic microstructure exhibit direction-dependent refractive index, known as form birefringence. One of the main advantages of these nanostructured materials is that the ease of fabrication significantly reduces the cost of production. However, their birefringence is affected by humidity as well as time. The hypothesis is that defects, particularly silanols, are responsible. Here, in this work, we present the use of hexamethyldisilazane (HMDS) vapor as a passivation strategy. Using spectroscopic ellipsometry and Raman scattering, the data show that HMDS successfully passivates silanol groups and promotes O-Si-O bond formation, resulting in improved stability. The results demonstrate a simple method to enhance the reliability of all-silica polarization optics offering potential advancements for high-power laser components.

Mireles, Marcela [Univ. of Rochester, NY (United S

Correction for losses in optical birefringent networks, a concept

Technique determines the effects of losses upon the performance of a birefringent network and shows how the desired amplitude transmittance of the network may be corrected /or predistorted/, prior to synthesizing the birefringent network, to prevent the effects of crystal losses.

Amman, E. O.

Synthesis of optical birefringent networks.

Outline of synthesis procedures, with description of the birefringent networks which result from their use. Optical compensators are employed in synthesis procedures in two different ways. The first role is simply the practical one of compensating for slightly incorrect crystal lengths. The second role occurs because some synthesis procedures require different fractional retardations for the stages of the network. Lyot and Solc filters are described, and an attempt is made to show how birefringent networks function. Experimental results are presented, and the application of synthesis procedures to electrooptic networks is discussed.

Ammann, E. O.

A study of birefringence in the interstellar medium in the direction of the Crab Nebula

The interstellar medium may be regarded as a weak wave plate, the linear birefringence arising from the aligned grains which produce interstellar linear polarization. Using the Crab Nebula as a background source of linearly polarized light we have investigated this birefringence by measurements of circular polarization. The circular component is found to vary with the intrinsic linear polarization in a sinusoidal fashion characteristic of a wave plate with the orientation expected from independent measurements of the interstellar linear polarization in the same direction. Measurements of the wavelength dependence, together with the sense and magnitude of the circular polarization are interpreted as evidence for the dielectric nature of the interstellar grain materials. These observations provide a firm basis for a similar interpretation of the circular polarization of reddened stars. The observations of the stars can then be used to study the grain composition and the structure of the magnetic field in many directions in the Galaxy.

Martin, P. G.

The effect of vacuum birefringence on the polarization of X-ray binaries and pulsars

In a strong magnetic field the vacuum becomes birefringent. This effect is especially important for pulsars at X-ray wavelengths. Any polarized X-ray emission from the surface of a magnetic neutron star becomes depolarized as it propagates through the magnetic field. The soft X-ray emission from AM Her, believed to be a magnetic white dwarf, may show about one radian of phase retardation. In this case, circular polarization of the X-ray flux would be a characteristic signature of vacuum birefringence.

Novick, R.

Development of orthotropic birefringent materials for photoelastic stress analysis

Materials were selected and fabrication procedures developed for orthotropic birefringent materials. An epoxy resin (Maraset 658/558 system) was selected as the matrix material. Fibers obtained from style 3733 glass cloth and type 1062 glass roving were used as reinforcement. Two different fabrication procedures were used. In the first one, layers of unidirectional fibers removed from the glass cloth were stacked, impregnated with resin, bagged and cured in the autoclave at an elevated temperature. In the second procedure, the glass roving was drywound over metal frames, impregnated with resin and cured at room temperature under pressure and vacuum in an autoclave. Unidirectional, angle-ply and quasi-isotropic laminates of two thicknesses and with embedded flaws were fabricated. The matrix and the unidirectional glass/epoxy material were fully characterized. The density, fiber volume ratio, mechanical, and optical properties were determined. The fiber volume ratio was over 0.50. Birefringent properties were in good agreement with predictions based on a stress proportioning concept and also, with one exception, with properties predicted by a finite element analysis.

Daniel, I. M.

Development and characterization of orthotropic-birefringent materials

Materials were selected and fabrication procedures developed for orthotropic birefringent materials. An epoxy resin (Maraset 658/558 system) was selected as the matrix material. Fibers obtained from style 3733 glass cloth and type 1062 glass roving were used as reinforcement. Two different fabrication procedures were used. In the first one, layers of unidirectional fibers removed from the glass cloth were stacked, impregnated with resin, bagged and cured in the autoclave at an elevated temperature. In the second procedure, the glass roving was drywound over metal frames, impregnated with resin and cured at room temperature under pressure and vacuum in an autoclave. Unidirectional, angle-ply and quasi-isotropic laminates of two thicknesses and with embedded flaws were fabricated. The matrix and the unidirectional glass/epoxy material were fully characterized. The density, fiber volume ratio, mechanical, and optical properties were determined. The fiber volume ratio was over 0.50. Birefringent properties were in good agreement with predictions based on a stress proportioning concept and also, with one exception, with properties predicted by a finite element analysis. Previously announced in STAR as N81-26183

Daniel, I. M.