Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Background radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background Adaptive Radiation Detection (BARD) v1.0.0

The Background Adaptive Radiation Software can be deployed with static sensors in urban environments. It provides a real-time robust radiation detection based on a unique adaptive learning approach. Local radiation background models are automatically learnt for various environmental conditions, and monitored/re-trained, and selected over time for optimal radiation anomaly detection, informed by source templates directly derived from the data.

Abgrall, Nicolas↗

A hierarchical Bayesian model for background variation in radiation source localization

In this paper, we apply a new model to account for varying background radiation in radiological source localization. We present a hierarchical Bayesian model that simultaneously infers background and source location parameters without requiring separate estimation of the background radiation at each detector location. We employ a simplified photon transport model to reduce the computational expense of Bayesian model calibration. Furthermore, we demonstrate the model accuracy by localizing a cesium-137 source in a simulated city block, and we analyze experimental field measurements with varying background. In both cases, the model provides sufficient fidelity that we can locate the source while simultaneously estimating background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗

Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1–2) ×10−12 pb at a WIMP mass of 40 GeV/ c 2 . This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A decay database of coincident γ–γ and γ–X -ray branching ratios for in-field spectroscopy applications

Current fieldable spectroscopy techniques often use single detector systems heavily impacted by interferences from intense background radiation fields. These effects result in low-confidence measurements that can lead to misinterpretation of the collected spectrum. To help improve interpretation of the fission products and short-lived radionuclides produced in a composite sample, a coincidence-database is being developed in support of a robust portable and X-ray coincidence detector system concurrently under development at the Pacific Northwest National Laboratory for in-field deployment. Hitherto, no database exists containing coincident γ–γ and γ–X-ray branching-ratio intensities on an absolute scale that will greatly enhance isotopic identification for in-field applications. As part of this project, software has been developed to parse all radioactive-decay data sets from the Evaluated Nuclear Structure Data File (ENSDF) archive to enable translation into a more useful JavaScript Object Notation (JSON) formats that more readily supports query-based data manipulation. The coincident database described in this work is the first of its kind and contains coincidence γ–γ and γ–X-ray intensities and their corresponding uncertainties, together with auxiliary metadata associated with each decay data set. The new JSON format provides a convenient and portable means of data storage that can be imported into analysis frameworks with relatively low overhead allowing for meaningful comparison with measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Degradation of the contrast of a short light pulse in a CPA system

We have calculated the effect of four-wave mixing of the main radiation pulse with the background radiation components on the value of the output radiation contrast in a chirped pulse amplification system of petawatt laser facilities. Formulae are presented that make it possible to quantify the contributions of two mechanisms, i.e. Kerr nonlinearity of the refractive index of the amplifying medium and gain saturation. For typical values of the nonlinear refractive index, both contributions are comparable. The possibility of mutual quenching of nonlinear contributions is noted. The influence of spectral filtering of radiation on the output pulse contrast is considered. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A transcriptome software comparison for the analyses of treatments expected to give subtle gene expression responses

Background: In this comparative study we evaluate the performance of four software tools: DNAstar-D (DESeq2), DNAstar-E (edgeR), CLC Genomics and Partek Flow for identification of differentially expressed genes (DEGs) using a transcriptome of E. coli. The RNA-seq data are from the effect of below-background radiation 5.5 nGy total dose (0.2nGy/hr) on E. coli grown shielded from natural radiation 655 m below ground in a pre-World War II steel vault. The gene expression response to three supplemented sources of radiation designed to mimic natural background, 1952 – 5720 nGy in total dose (71–208 nGy/hr), are compared to this “radiation-deprived” treatment. In addition, RNA-seq data of Caenorhabditis elegans nematode from similar radiation treatments was analyzed by three of the software packages. Results: In E. coli, the four software programs identified one of the supplementary sources of radiation (KCl) to evoke about 5 times more transcribed genes than the minus-radiation treatment (69–114 differentially expressed genes, DEGs), and so the rest of the analyses used this KCl vs “Minus” comparison. After imposing a 30-read minimum cutoff, one of the DNAStar options shared two of the three steps (mapping, normalization, and statistic) with Partek Flow (they both used median of ratios to normalize and the DESeq2 statistical package), and these two programs identified the highest number of DEGs in common with each other (53). In contrast, when the programs used different approaches in each of the three steps, between 31 and 40 DEGs were found in common. Regarding the extent of expression differences, three of the four programs gave high fold-change results (15–178 fold), but one (DNAstar’s DESeq2) resulted in more conservative fold-changes (1.5–3.5). In a parallel study comparing three qPCR commercial validation software programs, these programs also gave variable results as to which genes were significantly regulated. Similarly, the C. elegans analysis showed exaggerated fold-changes in CLC and DNAstar’s edgeR while DNAstar-D was more conservative. Conclusions: Regarding the extent of expression (fold-change), and considering the subtlety of the very low level radiation treatments, in E. coli three of the four programs gave what we consider exaggerated fold-change results (15 – 178 fold), but one (DNAstar’s DESeq2) gave more realistic fold-changes (1.5–3.5). When RT-qPCR validation comparisons to transcriptome results were carried out, they supported the more conservative DNAstar-D’s expression results. When another model organism’s (nematode) response to these radiation differences was similarly analyzed, DNAstar-D also resulted in the most conservative expression patterns. Therefore, we would propose DESeq2 (“DNAstar-D”) as an appropriate software tool for differential gene expression studies for treatments expected to give subtle transcriptome responses.

59 BASIC BIOLOGICAL SCIENCES↗

Expectation-propagation for weak radionuclide identification at radiation portal monitors

We propose a sparsity-promoting Bayesian algorithm capable of identifying radionuclide signatures from weak sources in the presence of a high radiation background. The proposed method is relevant to radiation identification for security applications. In such scenarios, the background typically consists of terrestrial, cosmic, and cosmogenic radiation that may cause false positive responses. We evaluate the new Bayesian approach using gamma-ray data and are able to identify weapons-grade plutonium, masked by naturally-occurring radioactive material (NORM), in a measurement time of a few seconds. We demonstrate this identification capability using organic scintillators (stilbene crystals and EJ-309 liquid scintillators), which do not provide direct, high-resolution, source spectroscopic information. Compared to the EJ-309 detector, the stilbene-based detector exhibits a lower identification error, on average, owing to its better energy resolution. Organic scintillators are used within radiation portal monitors to detect gamma rays emitted from conveyances crossing ports of entry. The described method is therefore applicable to radiation portal monitors deployed in the field and could improve their threat discrimination capability by minimizing “nuisance” alarms produced either by NORM-bearing materials found in shipped cargoes, such as ceramics and fertilizers, or radionuclides in recently treated nuclear medicine patients.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comprehensive Baseline Environmental Monitoring of an Interim Legacy Waste Store in Arid Zone Australia - 20062

Radionuclide containing soil and rubble from the clean-up of a former uranium, thorium and rare earth minerals processing research facility carried out in the early 50's and 60's is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to developing a final disposal pathway commensurate with waste acceptance criteria, a comprehensive baseline environmental monitoring has been carried out to establish the background radiation levels. The survey included in situ gamma scanning of the surface soil ({sup 238}U, {sup 232}Th, {sup 40}K), a laboratory analysis of 86 soil samples (from 0-20 cm depth), which involved XRF measurements (U, Th, and rare earth metals) and spectroscopic analysis ({sup 238}U, {sup 232}Th, {sup 226}Ra and daughter nuclides). A time series of radon concentration measurements in air was established, while soil radon ({sup 222}Rn) and thoron ({sup 220}Rn) flux measurements were undertaken at 18 different locations. The 2018 comprehensive baseline survey demonstrated radiation levels in the immediate vicinity of the Woomera interim waste store are typical background values of soil and rock. No contamination was detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

Roy, Tanay↗

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗