Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BIOPSY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Upgrading the Gleason Score in Extended Prostate Biopsy: Implications for Treatment Choice

Purpose: To determine the incidence of overestimation of Gleason score (GS) in extended prostate biopsy, and consequently circumventing unnecessary aggressive treatment. Methods and Materials: This is a retrospective study of 464 patients who underwent prostate biopsy and radical prostatectomy between January 2001 and November 2007. The GS from biopsy and radical prostatectomy were compared. The incidence of overestimation of GS in biopsies and tumor volume were studied. Multivariate analysis was applied to find parameters that predict upgrading the GS in prostate biopsy. Results: The exact agreement of GS between prostate biopsy and radical prostatectomy occurred in 56.9% of cases. In 29.1% cases it was underestimated, and it was overestimated in 14%. One hundred and six (22.8%) patients received a diagnosis of high GS (8, 9, or 10) in a prostate biopsy. In 29.2% of cases, the definitive Gleason Score was 7 or lower. In cases in which GS was overestimated in the biopsy, tumors were significantly smaller. In multivariate analysis, the total percentage of tumor was the only independent factor in overestimation of GS. Tumors occupying less than 33% of cores had a 5.6-fold greater chance of being overestimated. Conclusion: In the extended biopsy era and after the International Society of Urological Pathology consensus on GS, almost one third of tumors considered to have high GS at the biopsy may be intermediate-risk cancers. In that condition, tumors are smaller in biopsy. This should be remembered by professionals involved with prostate cancer to avoid overtreatment and undesirable side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-09: Quantitative Autoradiography of Biopsy Specimens Extracted Under PET/CT Guidance

Purpose: To develop a procedure for accurate determination of PET tracer concentration with high spatial accuracy in situ by performing Quantitative Autoradiography of Biopsy Specimens (QABS) extracted under PET/CT guidance. Methods: Autoradiography (ARG) standards were produced from a gel loaded with a known concentration of FDG biopsied with 18G and 20G biopsy needles. Specimens obtained with these needles are generally cylindrical: up to 18 mm in length and about 0.8 and 0.6 mm in diameter respectively. These standards, with similar shape and density as biopsy specimens were used to generate ARG calibration curves.Quantitative ARG was performed to measure the activity concentration in biopsy specimens extracted from ten patients. The biopsy sites were determined according to PET/CT's obtained in the operating room. Additional CT scans were acquired with the needles in place to confirm correct needle placements. The ARG images were aligned with the needle tip in the PET/CT images using the open source CERR software. The mean SUV calculated from the specimen activities (SUVarg) were compared to that from PET (SUVpet) at the needle locations. Results: Calibration curves show that the relation between ARG signal and activity concentration in those standards is linear for the investigated range (up to 150 kBq/ml). The correlation coefficient of SUVarg with SUVpet is 0.74. Discrepancies between SUVarg and SUVpet can be attributed to the small size of the biopsy specimens compared to PET resolution. Conclusion: The calibration procedure using surrogate biopsy specimens provided a method for quantifying the activity within the biopsy cores obtained under FDG-PET guidance. QABS allows mapping the activity concentration in such biopsy specimens with a resolution of about 1mm. QABS is a promising tool for verification of biopsy adequacy by comparing specimen activity to that expected from the PET image. A portion of this research was funded by a research grant from Biospace Lab, 13 rue Georges Auric 75019 Paris, FRANCE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of brush and biopsy sampling methods of the ileal pouch for assessment of mucosa-associated microbiota of human subjects

Mucosal biopsy is the most common sampling technique used to assess microbial communities associated with the intestinal mucosa. Biopsies disrupt the epithelium and can be associated with complications such as bleeding. Biopsies sample a limited area of the mucosa, which can lead to potential sampling bias. In contrast to the mucosal biopsy, the mucosal brush technique is less invasive and provides greater mucosal coverage, and if it can provide equivalent microbial community data, it would be preferable to mucosal biopsies. Results: We compared microbial samples collected from the intestinal mucosa using either a cytology brush or mucosal biopsy forceps. We collected paired samples from patients with ulcerative colitis (UC) who had previously undergone colectomy and ileal pouch anal anastomosis (IPAA), and profiled the microbial communities of the samples by sequencing V4-V6 or V4-V5 16S rRNA-encoding gene amplicons. Comparisons of 177 taxa in 16 brush-biopsy sample pairs had a mean R2 of 0.94. We found no taxa that varied significantly between the brush and biopsy samples after adjusting for multiple comparisons (false discovery rate ≤0.05). We also tested the reproducibility of DNA amplification and sequencing in 25 replicate pairs and found negligible variation (mean R2 = 0.99). A qPCR analysis of the two methods showed that the relative yields of bacterial DNA to human DNA were several-fold higher in the brush samples than in the biopsies. Conclusions: Mucosal brushing is preferred to mucosal biopsy for sampling the epithelial-associated microbiota. Although both techniques provide similar assessments of the microbial community composition, the brush sampling method has relatively more bacterial to host DNA, covers a larger surface area, and is less traumatic to the epithelium than the mucosal biopsy.

59 BASIC BIOLOGICAL SCIENCES↗

Improvement of prostate cancer detection combining a computer-aided diagnostic system with TRUS-MRI targeted biopsy

Purpose: To validate a novel consensus method, called target-in-target, combining human analysis of mpMRI with automated CAD system analysis, with the aim to increasing the prostate cancer detection rate of targeted biopsies. Methods: A cohort of 420 patients was enrolled and 253 patients were rolled out, due to exclusion criteria. 167 patients, underwent diagnostic 3T MpMRI. Two expert radiologists evaluated the exams adopting PI-RADSv2 and CAD system. When a CAD target overlapped with a radiologic one, we performed the biopsy in the overlapping area which we defined as target-in-target. Targeted TRUS-MRI fusion biopsy was performed in 63 patients with a total of 212 targets. The MRI data of all targets were quantitatively analyzed, and diagnostic findings were compared to pathologist’s biopsy reports. Results: CAD system diagnostic performance exhibited sensitivity and specificity scores of 55.2% and 74.1% [AUC = 0.63 (0.54 ÷ 0.71)] , respectively. Human readers achieved an AUC value, in ROC analysis, of 0.71 (0.63 ÷ 0.79). The target-in-target method provided a detection rate per targeted biopsy core of 81.8 % vs. a detection rate per targeted biopsy core of 68.6 % for pure PI-RADS based on target definitions. The higher per-core detection rate of the target-in-target approach was achieved irrespective of the presence of technical flaws and artifacts. Conclusions: A novel consensus method combining human reader evaluation with automated CAD system analysis of mpMRI to define prostate biopsy targets was shown to improve the detection rate per biopsy core of TRUS-MRI fusion biopsies. Results suggest that the combination of CAD system analysis and human reader evaluation is a winning strategy to improve targeted biopsy efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous ureteral biopsy: safety and diagnostic yield

Purpose: To evaluate safety and diagnostic yield of percutaneous CT-guided biopsy of extrarenal upper urinary tract lesions. Materials and methods: Retrospective review of our institutional database of image-guided biopsies yielded 44 CT-guided percutaneous biopsies in 44 unique patients that targeted ureteral (30, 68%) or other non-renal upper urinary tract lesions (14, 32%) between January 1, 2000 and May 1, 2017. Indications, pre-biopsy imaging, biopsy technique, peri-procedural antithrombotic use, complications including bleeding defined by Society of Interventional Radiology criteria, pathology results, and subsequent imaging were reviewed up to 3 months after the procedure to evaluate safety and diagnostic yield. Results: Mean patient age was 66 (range 27–88) and 23/44 patients were male. The majority (34/44) of lesions were sampled with an 18-gauge biopsy device via a 17-gauge introducer needle, and the remaining 10/44 lesions were sampled with a 19/20 gauge system. The mean number of core samples obtained was 4 (range 2–10). No major complications occurred. Specifically, no patient developed a urine leak or urinary obstruction. Minor complications occurred in 3/44 (7%) biopsies, all retroperitoneal hemorrhages that did not require transfusion or other intervention. Biopsy was adequate for pathologic examination in 41 of 44 (93%) cases. Among patients undergoing surgical resection, biopsy diagnosis was concordant with surgical pathology in 9/10 (90%) cases and discordant in 1/10 (10%). Conclusion: CT-guided percutaneous biopsy of upper urinary tract lesions can be performed safely, with high diagnostic yield, and with a high rate of concordance on subsequent surgical pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall survival in patients with high-grade tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-06: Optimized Patient Inclusion for NaF PET Response-Based Biopsies

Purpose: A method to guide mid-treatment biopsies using quantitative [F-18]NaF PET/CT response is being investigated in a clinical trial. This study aims to develop methodology to identify patients amenable to mid-treatment biopsy based on pre-treatment imaging characteristics. Methods: 35 metastatic prostate cancer patients had NaF PET/CT scans taken prior to the start of treatment and 9–12 weeks into treatment. For mid-treatment biopsy targeting, lesions must be at least 1.5 cm{sup 3} and located in a clinically feasible region (lumbar/sacral spine, pelvis, humerus, or femur). Three methods were developed based on number of lesions present prior to treatment: a feasibility-restricted method, a location-restricted method, and an unrestricted method. The feasibility restricted method only utilizes information from lesions meeting biopsy requirements in the pre-treatment scan. The unrestricted method accounts for all lesions present in the pre-treatment scan. For each method, optimized classification cutoffs for candidate patients were determined. Results: 13 of the 35 patients had enough lesions at the mid-treatment for biopsy candidacy. Of 1749 lesions identified in all 35 patients at mid-treatment, only 9.8% were amenable to biopsy. Optimizing the feasibility-restricted method required 4 lesions at pre-treatment meeting volume and region requirements for biopsy, resulting patient identification sensitivity of 0.8 and specificity of 0.7. Of 6 false positive patients, only one patient lacked lesions for biopsy. Restricting for location alone showed poor results (sensitivity 0.2 and specificity 0.3). The optimized unrestricted method required patients have at least 37 lesions in pretreatment scan, resulting in a sensitivity of 0.8 and specificity of 0.8. There were 5 false positives, only one lacked lesions for biopsy. Conclusion: Incorporating the overall pre-treatment number of NaF PET/CT identified lesions provided best prediction for identifying candidate patients for mid-treatment biopsy. This study provides validity for prediction-based inclusion criteria that can be extended to various clinical trial scenarios. Funded by Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm{sup 2}-diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37{sup o}C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both groups). The incidence of pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7 patients: 13.7 %), from which one patient developed a persistent air leakage necessitating pleurodesis.ConclusionPneumothorax complicating CT-guided core biopsy of pulmonary lesions, showed the insignificant difference between coaxial and non-coaxial techniques. However, both techniques have the same significant risk factors including small and basal lesions, increased lesion’s depth from pleural surface, and increased length of aerated lung parenchyma crossed by biopsy needle and passing through pulmonary fissures in the needle tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Biochemical Relapse-Free Survival Between Primary Gleason Score 3 and Primary Gleason Score 4 for Biopsy Gleason Score 7 Prostate Cancer

Purpose: To determine whether the primary grade (PG) of biopsy Gleason score (GS) 7 prostate cancer (CaP) was predictive for biochemical relapse-free survival (bRFS). Most of the present data regarding the PG of GS7 CaP refer to surgical specimens. Our goal was to determine whether the biopsy GS used at the time of medical decision making predicted for the biochemical outcome. Methods and Materials: We reviewed the data from 705 patients with biopsy GS7 CaP, from a prospectively maintained database, who had been treated at our institution between September 1996 and March 2005 with radical prostatectomy (n = 310), external beam radiotherapy (n = 268), or prostate radioactive seed implantation (n = 127). The bRFS rates were estimated using the Kaplan-Meier method. Cox proportional hazards regression analysis was used for univariate and multivariate analyses examining these factors in relation to bRFS: PG of biopsy GS, initial prostate-specific antigen level, clinical T stage, use of androgen deprivation, risk group (high or intermediate), and treatment modality. Results: The 5-year bRFS rate was 78% and 71% (p = 0.0108) for biopsy GS7 PG3 CaP and biopsy GS7 PG4 CaP, respectively. Comparing PG3 and PG4 within treatment modalities, only prostate implantation patients had a significant difference in the 5-year bRFS rate, 88% vs. 76%, respectively (p = 0.0231). On multivariate analysis, the PG of biopsy GS remained an independent predictor of bRFS, with PG3 having better bRFS than PG4 (relative risk, 0.655; 95% confidence interval, 0.472-0.909; p = 0.0113). Conclusion: Biopsy GS7 PG4 CaP carries a worse bRFS than biopsy GS7 PG3 CaP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Renal Biopsy: Our Experience and Technical Considerations

The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient was temporarily dialyzed; the remaining patient required ureteric stenting. In conclusion, TJRB provides an adequate yield for diagnosis. Complication rates are relatively high, but patients are also at high risk from the conventional percutaneous approach. Patient selection and optimization are critical to avoid major complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Accuracy of Percutaneous Biopsy Using “Cross and Push” Technique for Patients Suspected with Malignant Biliary Strictures

PurposeVarious methods have been used to sample biliary strictures, including percutaneous fine-needle aspiration biopsy, intraluminal biliary washings, and cytological analysis of drained bile. However, none of these methods has proven to be particularly sensitive in the diagnosis of biliary tract malignancy. We report improved diagnostic accuracy using a modified technique for percutaneous transluminal biopsy in patients with this disease.Materials and MethodsFifty-two patients with obstructive jaundice due to a biliary stricture underwent transluminal forceps biopsy with a modified “cross and push” technique with the use of a flexible biopsy forceps kit commonly used for cardiac biopsies. The modification entailed crossing the stricture with a 0.038-in. wire leading all the way down into the duodenum. A standard or long sheath was subsequently advanced up to the stricture over the wire. A Cook 5.2-Fr biopsy forceps was introduced alongside the wire and the cup was opened upon exiting the sheath. With the biopsy forceps open, within the stricture the sheath was used to push and advance the biopsy cup into the stricture before the cup was closed and the sample obtained. The data were analysed retrospectively.ResultsWe report the outcomes of this modified technique used on 52 consecutive patients with obstructive jaundice secondary to a biliary stricture. The sensitivity and accuracy were 93.3 and 94.2 %, respectively. There was one procedure-related late complication.ConclusionWe propose that the modified “cross and push” technique is a feasible, safe, and more accurate option over the standard technique for sampling strictures of the biliary tree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greater Biopsy Core Number Is Associated With Improved Biochemical Control in Patients Treated With Permanent Prostate Brachytherapy

Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores ({<=}6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluated as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and {<=}6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Pathologic Upgrading or Locally Advanced Disease in Early Prostate Cancer Patients Based on Biopsy Gleason Score and PSA: A Population-Based Study of Modern Patients

Purpose: Radiation oncologists rely on available clinical information (biopsy Gleason score and prostate-specific antigen [PSA]) to determine the optimal treatment regimen for each prostate cancer patient. Existing published nomograms correlating clinical to pathologic extent of disease were based on patients treated in the 1980s and 1990s at select academic institutions. We used the Surveillance, Epidemiology, and End Results (SEER) database to examine pathologic outcomes (Gleason score and cancer stage) in early prostate cancer patients based on biopsy Gleason score and PSA concentration. Methods and Materials: This analysis included 25,858 patients whose cancer was diagnosed between 2010 and 2011, with biopsy Gleason scores of 6 to 7 and clinical stage T1 to T2 disease, who underwent radical prostatectomy. In subgroups based on biopsy Gleason score and PSA level, we report the proportion of patients with pathologically advanced disease (positive surgical margin or pT3-T4 disease) or whose Gleason score was upgraded. Logistic regression was used to examine factors associated with pathologic outcomes. Results: For patients with biopsy Gleason score 6 cancers, 84% of those with PSA <10 ng/mL had surgical T2 disease with negative margins; this decreased to 61% in patients with PSA of 20 to 29.9 ng/mL. Gleason score upgrading was seen in 43% (PSA: <10 ng/mL) to 61% (PSA: 20-29.9 ng/mL) of biopsy Gleason 6 patients. Patients with biopsy Gleason 7 cancers had a one-third (Gleason 3 + 4; PSA: <10 ng/mL) to two-thirds (Gleason 4 + 3; PSA: 20-29.9 ng/mL) probability of having pathologically advanced disease. Gleason score upgrading was seen in 11% to 19% of patients with biopsy Gleason 4 + 3 cancers. Multivariable analysis showed that higher PSA and older age were associated with Gleason score upgrading and pathologically advanced disease. Conclusions: This is the first population-based study to examine pathologic extent of disease and pathologic Gleason score upgrading based on clinically available information in modern patients. These data inform the selection of radiation therapy strategies and an understanding of whether prostatectomy alone is likely to be curative for patients with early prostate cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM and US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212 genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably identified, targeting with radiotherapy should improve outcome. This is the first demonstration of a link between quantitative imaging features (radiomics) with genomic features in MRI-directed prostate biopsies. The research was supported by NIH- NCI R01 CA 189295 and R01 CA 189295; E Davicioni is partial owner of GenomeDx Biosciences, Inc. M Takhar, N Erho, L Lam, C Buerki and E Davicioni are current employees at GenomeDx Biosciences, Inc.

60 APPLIED LIFE SCIENCES↗