Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SCANNERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

WE-EF-207-05: Monte Carlo Dosimetry for a Dedicated Cone-Beam CT Head Scanner

Purpose: Cone-Beam CT (CBCT) is an attractive platform for point-of-care imaging of traumatic brain injury and intracranial hemorrhage. This work implements and evaluates a fast Monte-Carlo (MC) dose estimation engine for development of a dedicated head CBCT scanner, optimization of acquisition protocols, geometry, bowtie filter designs, and patient-specific dosimetry. Methods: Dose scoring with a GPU-based MC CBCT simulator was validated on an imaging bench using a modified 16 cm CTDI phantom with 7 ion chamber shafts along the central ray for 80–100 kVp (+2 mm Al, +0.2 mm Cu). Dose distributions were computed in a segmented CBCT reconstruction of an anthropomorphic head phantom with 4×10{sup 5} tracked photons per scan (5 min runtime). Circular orbits with angular span ranging from short scan (180° + fan angle) to full rotation (360°) were considered for fixed total mAs per scan. Two aluminum filters were investigated: aggressive bowtie, and moderate bowtie (matched to 16 cm and 32 cm water cylinder, respectively). Results: MC dose estimates showed strong agreement with measurements (RMSE<0.001 mGy/mAs). A moderate (aggressive) bowtie reduced the dose, per total mAs, by 20% (30%) at the center of the head, by 40% (50%) at the eye lens, and by 70% (80%) at the posterior skin entrance. For the no bowtie configuration, a short scan reduced the eye lens dose by 62% (from 0.08 mGy/mAs to 0.03 mGy/mAs) compared to full scan, although the dose to spinal bone marrow increased by 40%. For both bowties, the short scan resulted in a similar 40% increase in bone marrow dose, but the reduction in the eye lens was more pronounced: 70% (90%) for the moderate (aggressive) bowtie. Conclusions: Dose maps obtained with validated MC simulation demonstrated dose reduction in sensitive structures (eye lens and bone marrow) through combination of short-scan trajectories and bowtie filters. Xiaohui Wang and David Foos are employees of Carestream Health.

60 APPLIED LIFE SCIENCES↗

Ramp Generator for Electron Scanner in SNS Beam Profile Measurements System

A new fast high voltage Ramp Generator to deflect an electron beam in the Electron Scanner is required at the Spallation Neutron Source (SNS) in the Oak Ridge National Laboratory. The Electron Scanner is used for non-destructively measuring the transverse profiles of the proton beam in the accumulator ring of the SNS [1]. The existing deflector is obsolete and needs to be replaced. A new Ramp Generator is proposed based on fast high voltage MOSFET power switches. Two configurations have been considered. One is bipolar, with two opposite polarity power supplies and one switch module or two single switches, and the other is unipolar, with one power supply and two switch modules. Schematics and performance of both options are described, and results of the prototype testing are presented in the paper.

Peplov, Vladimir↗

Filtered-backprojection reconstruction for a cone-beam computed tomography scanner with independent source and detector rotations

Purpose: A new cone-beam CT scanner for image-guided radiotherapy (IGRT) can independently rotate the source and the detector along circular trajectories. Existing reconstruction algorithms are not suitable for this scanning geometry. The authors propose and evaluate a three-dimensional (3D) filtered-backprojection reconstruction for this situation. Methods: The source and the detector trajectories are tuned to image a field-of-view (FOV) that is offset with respect to the center-of-rotation. The new reconstruction formula is derived from the Feldkamp algorithm and results in a similar three-step algorithm: projection weighting, ramp filtering, and weighted backprojection. Simulations of a Shepp Logan digital phantom were used to evaluate the new algorithm with a 10 cm-offset FOV. A real cone-beam CT image with an 8.5 cm-offset FOV was also obtained from projections of an anthropomorphic head phantom. Results: The quality of the cone-beam CT images reconstructed using the new algorithm was similar to those using the Feldkamp algorithm which is used in conventional cone-beam CT. The real image of the head phantom exhibited comparable image quality to that of existing systems. Conclusions: The authors have proposed a 3D filtered-backprojection reconstruction for scanners with independent source and detector rotations that is practical and effective. This algorithm forms the basis for exploiting the scanner’s unique capabilities in IGRT protocols.

60 APPLIED LIFE SCIENCES↗

Beam Dynamics Studies at the PIP-II Injector Test Facility

A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised of a 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1- MeV CW RFQ, followed by a 10-m Medium Energy Beam Transport (MEBT), 2 cryomodules accelerating the beam to 16 MeV and a High-Energy Beam Transport (HEBT) bringing the beam to a dump. This paper presents beam dynamics - related measurements performed at PIP2IT such as the Twiss parameters with Allison scanners, beam envelopes along the injector, and transverse and longitudinal rms emittance reconstruction. These measurements are compared with predictions from the beam dynamics code Tracewin.

43 PARTICLE ACCELERATORS↗

Beam Emittance Measurement with Laser Wire Scanners in the ILC Beam Delivery System

Accurate measurement of the beam phase-space is essential for the next generation of electron accelerators. A scheme for beam optics optimization and beam matrix reconstruction algorithms for the diagnostics section of the beam delivery system of the International Linear Collider based on laser-wire beam profile monitors are discussed. Possible modes of operation of the laser-wire system together with their corresponding performance are presented. Based on these results, prospects for reconstructing the ILC beam emittance from representative laser-wire beam size measurements are evaluated.

43 PARTICLE ACCELERATORS↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

Design of a versatile multiaperture negative ion source

Negative ion sources are a key component of the neutral beam injector to be installed in the International Thermonuclear Experimental Reactor. At present research and development activities address several important issues related to beam extraction, optics, and optimization. Together with the design of real size devices and the accumulation of atomic cross section databases, a relatively small negative ion source [130 mA of H{sup -} at 60 kV, named Negative Ion Optimization phase 1 (NIO1)] is under construction at Consorzio RFX to contribute to benchmark numerical simulation tools and to test components, such as emittance scanners, beam dumps, and cesium ovens. NIO1 design, magnet configuration, and rf coupling simulations are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact electron cyclotron resonance accelerator for industrial and security applications

We describe the development of a novel accelerator, an electron Cyclotron Resonance Accelerator (eCRA) [1], to produce high power electron beams and X-ray beams for medical, research, sterilization, and national security applications. The several attractive features of eCRA include: a compact robust room-temperature single-cell RF cavity as the accelerating structure; continuous ampere-level high current output; and production of a self-rastering electron beam, thus eliminating the need for a separate beam scanner. Progress on the eCRA development, including numerical simulation, engineering design, and on-going experimental efforts will be reported here.

43 PARTICLE ACCELERATORS↗

Performance of an airborne imaging 92/183 GHz radiometer during the Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST)

An airborne imaging 92/183 GHz radiometer was recently flown onboard NASA's Convair 990 research aircraft during the February 1983 Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST). The 92 GHz portion of the radiometer was used to gather ice signature data and to generate real-time millimeter wave images of the marginal ice zone. Dry atmospheric conditions in the Arctic resulted in good surface ice signature data for the 183 GHz double sideband (DSB) channel situated + or - 8.75 GHz away from the water vapor absorption line. The radiometer's beam scanner imaged the marginal ice zone over a + or - 45 degrees swath angle about the aircraft nadir position. The aircraft altitude was 30,000 feet (9.20 km) maximum and 3,000 feet (0.92 km) minimum during the various data runs. Calculations of the minimum detectable target (ice) size for the radiometer as a function of aircraft altitude were performed. In addition, the change in the atmospheric attenuation at 92 GHz under varying weather conditions was incorporated into the target size calculations. A radiometric image of surface ice at 92 GHz in the marginal ice zone is included.

Gagliano, J. A.↗

A prototype fan-beam optical CT scanner for 3D dosimetry

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a 100 kV pulse generator for driving an electron scanner used in proton beam profile measurements

The Spallation Neutron Source (SNS) utilizes an electron scanner in the accumulator ring for nondestructive transverse profiling of the proton beam. The electron scanner consists of a high voltage pulse generator driving an electron gun, a medium voltage ramp generator, and a CCD camera. A new high voltage pulse generator that provides negative 100 kV pulses with rise times of less than 200 ns, +/-0.5% flattop of greater than 100 ns has been designed, delivered, and undergone extensive testing. The pulse generator has been operationally verified with the existing control system and simulated loads. Full system testing with the actual electron scanner is planned. This paper details the requirements, design, setup, and test results of the high voltage pulse generator.

Morris, B↗

Wire scanner assessment of transverse beam size in the Fermilab side-coupled linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

Wire Scanner Assessment of Transverse Beam Size in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

WIRE SCANNER FOR HIGH INTENSITY BEAM PROFILE DIAGNOSITICS

A control and data acquisition system of a high speed wire scanner is developed for high intensity beam profile diagnostics. The control system of the wire scanner includes two IOCs, a Soft IOC and a VME IOC. The Soft IOC connects with an Aerotech Ensemble motor drive through EPCIS motor record and controls the movement of the wire scanner. An Electrical Input card samples the real-time position of the wire through an incremental encoder, and generates a pulse to synchronize a VME ADC data acquisition card, which digitizes and samples the beam-induced signal after pre-amplification. A VME Relay Output card is installed to control the Brake Solenoid and Actuator Solenoid. All the VME I/O cards are installed on one VME crate and controlled by the VME IOC. The system configuration and software of the wire scanner are under development.

Yan, J.↗

Measurements of a 2.1 MeV H− beam with an Allison scanner

Transverse 2D phase space distributions of a 2.1 MeV, 5 mA H− beam are measured at the Proton Improvement Plan II Injector Test accelerator at Fermilab with an Allison scanner. This paper describes the design, calibration, and performance of the scanner along with the main results from beam measurements. Analyses of the recorded phase portraits are performed primarily in action-phase coordinates. The stability of the action under linear optics makes it easier to compare measurements taken under different beamline conditions. The amplitude of a single measured point (“pixel”) is proportional to the phase density in the corresponding portion of the beam. When the Twiss parameters are calculated using only the high-phase density part of the beam, the pixel amplitude in the beam core is found to be decreasing approximately exponentially with action and to be phase-independent. Outside of the core, the amplitudes decrease with action at a slower rate than in the core. This “tail” comprises 10%–30% of the beam, with 0.1% of the total measured intensity extending beyond action 10–20 times larger than the rms emittance. The transition from the core to the tail is accompanied by the appearance of two “branches” that are separated in phase and extend beyond the core. A set of selected measurements shows that there is no measurable emittance dilution along the beamline; the beam parameters are practically constant over a 0.5 ms pulse; and scraping in various parts of the beamline is an effective way to decrease the transverse tails by removing the branches.

Richard, C. (ORCID:000000029891135X)↗

Measurements of a 2.1 MeV H$^-$ beam with an Allison scanner

Transverse 2D phase space distribution of a 2.1 MeV, 5 mA H$^-$ beam is measured at the PIPIT test accelerator at Fermilab with an Allison scanner. The paper describes the design, calibration, and performance of the scanner as well as the main results of the beam measurements. Analyses of the recorded phase portraits are performed primarily in action-phase coordinates; the stability of the action under linear optics makes it easier to compare measurements taken with different beamline conditions, e.g. in various locations. The intensity of a single measured point (\pixel") is proportional to the phase density in the corresponding portion of the beam. When the Twiss parameters are calculated using only the high-phase density part of the beam, the pixel intensity in the beam core is found to be decreasing exponentially with action and to be phase-independent. Outside of the core, the intensities decrease with action at a significantly slower rate than in the core. This `tail' comprises 10-30% of the beam, with 0.1% of the total measured intensity extending beyond the action 10-20 times larger than the rms emittance. The transition from the core to the tail is accompanied by the appearance of a strong phase dependence, which is characterized in action-phase coordinates by two `branches' extending beyond the core. A set of selected measurements shows, in part, that there is no measurable emittance dilution along the beam line in the main portion of the beam; the beam parameters are practically constant over a 0.5 ms pulse; and scraping in various parts of the beam line is an effective way to decrease the transverse tails by removing the branches.

43 PARTICLE ACCELERATORS↗

First Test Results of the New LANSCE Wire Scanner

The Beam Diagnostics and Instrumentation Team (BDIT) at Los Alamos National Laboratory's LANSCE facility is presently developing a new and improved wire scanner diagnostics system controlled by National Instrument's cRIO platform. This paper describes the current state of development of the control system along with the results gathered from the latest actuator motion performance and accelerator-beam data acquisition tests.

Accelerator Design, Technology, and Operations↗

THE LASER EMITTANCE SCANNER FOR 1 GEV H- BEAM

A transverse phase space laser emittance scanner is proposed [1] and under development for the 1-GeV H- SNS linac, using a laser beam as a slit. For a 1-GeV H- beam, it is difficult to build a slit because the stopping distance is more than 50 cm in copper. We propose a Laser Emittance Scanner (LES) to use a laser beam as an effective slit by stripping off the outer electron of the H- (making it neutral) upstream of a bend magnet and measuring the stripped component downstream of the bend magnet. The design and modeling of the system will be discussed. We are expecting to make a preliminary measurement in 2009.

43 PARTICLE ACCELERATORS↗