Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atlanta”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data Quality Assessment Process for Real-Time Data-Driven Traffic Microsimulation of Smart Corridor

Smart corridor digital twins are often created for the development and evaluation of emerging intelligent transportation systems and Connected and Autonomous Vehicle (CAV) technologies. However, limited guidance exists for data quality assessment for digital twin development. To address this, this paper discusses the data quality assessment utilized to develop data-driven real-time microscopic simulation models, i.e., digital twins, for two separate smart corridors: the North Avenue Smart Corridor in Atlanta, GA, and the Martin Luther King Smart Corridor in Chattanooga, Tennessee. This paper provides a summary of the author’s investigations of data requirements and data characteristics for the given smart corridor digital twin development efforts. With a focus on data, this summary includes a description of the data investigation process, key data issues observed, and strategies to address observed issues. Discussion is provided to help expand the lessons from these studies to other digital twin development efforts.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

e RPCA : Robust Principal Component Analysis for Exponential Family Distributions

Abstract Robust principal component analysis (RPCA) is a widely used method for recovering low‐rank structure from data matrices corrupted by significant and sparse outliers. These corruptions may arise from occlusions, malicious tampering, or other causes for anomalies, and the joint identification of such corruptions with low‐rank background is critical for process monitoring and diagnosis. However, existing RPCA methods and their extensions largely do not account for the underlying probabilistic distribution for the data matrices, which in many applications are known and can be highly non‐Gaussian. We thus propose a new method called RPCA for exponential family distributions (), which can perform the desired decomposition into low‐rank and sparse matrices when such a distribution falls within the exponential family. We present a novel alternating direction method of multiplier optimization algorithm for efficient decomposition, under either its natural or canonical parametrization. The effectiveness of is then demonstrated in two applications: the first for steel sheet defect detection and the second for crime activity monitoring in the Atlanta metropolitan area.

Zheng, Xiaojun↗

A validated thermal and biological model for predicting algal productivity in large scale outdoor cultivation systems

Proper assessment of the sustainability of algal products requires an understanding of algal growth rate with regional and temporal resolution. This study developed a bulk growth model that utilizes geospatial data, reactor geometry inputs, and a maximum of six strain-specific parameters to predict algal productivity with temporal and regional resolution. The model requires local weather data to calculate the time-resolved culture temperature which is combined with a biological model based on maximum theoretical carbon fixation to predict the time-resolved algal concentration. Validation of the model against experimental data illustrates an average ac- curacy of 0.27% ± 5.32% when comparing algal concentration at harvest over 45 days of cultivation data for Galdieria sulphuraria 5587.1, and Galdieria sulphuraria Soos grown in photobioreactors (PBRs) in Mesa, AZ (33.4152° N, 111.8315° W). For open raceway ponds (ORPs), an accuracy of 0.9% ± 2.35% was achieved when comparing algal concentration at harvest over 50 days of cultivation data for Chlorella vulgaris, Desmodesmus intermedius, Nannochloropsis oceanica grown in Atlanta, GA (33.7490° N, 84.3880° W) and Mesa, AZ (33.4152° N, 111.8315° W). The validation trials spanned three seasons (winter, spring, and summer) to ensure model ac- curacy throughout the year, and concentration between harvests was modeled with hourly resolution. The validated model is used to assess the productivity at several case-study locations in the United States with Chlorella vulgaris, grown in open raceway ponds and Galdieria sulphuraria grown in vertical flat panel photo- bioreactors. In conclusion, the model has been published as an open-source tool, in an effort to increase the fidelity of future studies that rely on outdoor algae cultivation for feedstock production and allow for time resolved results for future techno-economic and life cycle assessments.

59 BASIC BIOLOGICAL SCIENCES↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supply chain optimization of sustainable aviation fuel from carinata in the Southeastern United States

We report carinata is a purpose-grown oilseed feedstock for renewable fuels, including sustainable aviation fuel (SAF) that can replace conventional aviation fuel (CAF). Given carinata is a new crop in the Southeastern United States, it is crucial to analyze its sustainability from a supply chain perspective. This study developed a mixed-integer linear programming (MILP) model and simulated it for 20 years, starting from a farm (county-level data) and ending at the airport. About 2.06 million ha in Alabama, Florida, and Georgia combined were found suitable for carinata production. Given the three-year rotation period, about 0.69 million hectares can be cultivated annually, approximately 65% of which was in Georgia. About 2.4% of the combined SAF annual demand of four major airports (about 210 thousand t) in the study area is satisfied at that level of carinata cultivation. However, all available SAF was supplied to the Atlanta airport as this decision minimizes the supply chain cost. A total of 1343 storage units, one oil extraction mill, and one biorefinery were needed to meet the overall demand. We found that SW Georgia is the top supplier of carinata seeds. The unit cost of production and carbon intensity were estimated to be $\$$0.89 L -1 (or $\$$26.79 GJ -1 ) and 0.91 kg CO 2 e L -1 (or 27.28 kg CO 2 e GJ -1 ), respectively. This carbon intensity of carinata-based SAF was 67.8% lower than that of CAF. With variations included in SAF demand, yield, and soil carbon sequestration, carbon savings remained between 66.5% and 67.8%. Given the GHG advantage of SAF over CAF, there is justification for subsidies required to make SAF competitive.

10 SYNTHETIC FUELS↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating system responses to electric vehicle charging infrastructure expansion through data-driven simulation

Understanding the system responses to electric vehicle (EV) charging infrastructure expansion, including vehicle charging needs, station utilization, and energy consumption, is critical for effective planning to meet growing charging demand without unnecessary resource investment. This study evaluates the system responses to EV charging infrastructure expansion, focusing on charging needs, station utilization, and energy consumption. Using trip data from the National Household Travel Survey and origin–destination patterns, we simulated trip chains in downtown Atlanta with 10 % EV penetration. We assessed 32 scenarios involving different charging port power levels and siting strategies. Furthermore, we found that higher-power ports were more sensitive to placement, with concentrated expansion boosting station utilization more than uniform expansion. Adding high-power ports did not always increase peak energy consumption; in some cases, a few 400 kW ports reduced overall consumption compared to 150 kW ports by enabling faster charging and higher vehicle turnover.

Electric vehicle↗

Dynamic Evolution of Mass and Physical Properties of Atmospheric Organic Aerosol under Solar Irradiance

Organic aerosol (OA) particles constitute a substantial fraction of sub-micron particulate mass in the atmosphere and play a critical role in climate system. OA undergoes dynamic aging processes in the atmosphere, with photolytic aging induced by ultraviolet solar irradiance being an important yet poorly characterized mechanism. Knowledge gaps persist regarding the role of volatility transformations during photolytic aging on the OA mass decay kinetics and the evolution of climate-relevant properties, such as hygroscopicity, hindering the model evaluation of OA spatiotemporal distributions and atmospheric budgets. In this study, we conduct isothermal photolytic aging experiments on both laboratory-generated secondary organic aerosols and ambient-collected particles from urban Atlanta, utilizing a high-sensitivity Quartz Crystal Microbalance. Our results reveal that photolytic aging reduces 40–66% of the low-volatility OA mass with lifetimes ranging from 8 to 200 hours under solar irradiance, and 44–92% of the photolytic mass loss is through slow evaporation of semi- or intermediate-volatile products, kinetically limited by their volatility. We observe up to ±50% changes in OA hygroscopicity with the transformation of fresh OA to photo-recalcitrant low-volatility products, associated with changes in oxygen-to-carbon ratio and molecular weight. A kinetic model incorporating photolytic volatility transformation provides a cohesive explanation for the observed photolysis-induced changes in mass, volatility, and hygroscopicity. Our results can help constrain model representation of the dynamic evolutions of mass and climate-relevant properties during photolytic aging processes of the ambient OA, improving our understanding of OA atmospheric behavior and climate impact.

Bai, Bin↗

A Coupled Deep Learning Model for Estimating Surface NO 2 Levels from Remote Sensing Data: 15-Year Study Over the Contiguous United States

This study proposes a novel two-step deep learning (DL) model for estimating surface NO 2 concentrations using satellite data over the contiguous United States (CONUS) from 2005 to 2019. The first phase of the model uses partial convolutional neural network (PCNN), an advanced DL model that accurately imputes gaps between surface NO 2 stations and creates 5,478 daily-mean NO 2 grids (PCNN-NO 2 ) of the 2005-2019 period over the study area. We then feed the PCNN-NO 2 , along with other predictor variables, into a deep neural network (DNN) to estimate surface NO 2 levels, achieving exceptional performance with a correlation coefficient of 0.975 to 0.978, a mean absolute bias of 0.99 ppb to 1.38 ppb, and a root mean square error of 1.47 ppb to 1.97 ppb. Spatial cross-validation results also indicate strong spatial performance of PCNN-DNN surface NO 2 estimates. In addition to its accurate estimates, the PCNN-DNN model consistently generates estimated NO 2 grids without any missing values, improving the quality of various applications such as emission reduction strategies and public health studies. Between 2005 and 2019, the 5,478 daily estimated NO 2 grids over the CONUS reveal significant reductions in NO 2 levels in fourteen major urban environments: Washington D.C. (-43%), New York (-45%), Los Angeles (-38%), Chicago (-25%), Boston (-43%), Houston (-34%), Dallas (-40%), Philadelphia (-41%), Phoenix (-38%), Detroit (-20%), Denver (-23%), Atlanta (-0.7%), Cincinnati (-38%), and Pittsburgh (-56%). Furthermore, the study shows that the denser urban regions that in-situ stations are installed in, the higher the difference between in-situ observations and regional-mean NO 2 levels.

54 ENVIRONMENTAL SCIENCES↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anomaly detection for MPC forecast in Fleet of Water Heaters

Among residential devices, water heaters consume 20% of home energy use in the United States. Water heaters possess the capability to store energy within their reservoirs, enabling the ability to decouple energy use from hot water use. This capability can be used to reduce energy usage and costs while also supporting grid services. This requires accurate forecasting of the parameters of the water heater such as upper and lower temperatures. In this study, we analyzed the performance and behavior of a water heater model used in the real-world to predict a control mechanism that is implemented in a smart residential neighborhood. The model forecasts are accurate in most cases but not all. In such scenarios, error correction of the model is necessary to further improve model predictive control accuracy. Anomaly detection is the first step of error correction. This study complements existing research by grouping time series data into two clusters one with anomalies and another without anomalies. To achieve this task, we explored and compared multiple unsupervised machine learning algorithms to perform clustering. Among these algorithms, Ward clustering has the lowest running time and identified the highest number of anomalies for the upper temperature limit. The proposed approach is tested based on the data collected in a neighborhood with 46 townhomes located in Atlanta, GA.

Lebakula, Viswadeep↗

Evidence of Residential Demand Flexibility in a 46 Townhome Neighborhood

Demand response is an important emerging part of smart grids and it has been well researched from the theoretical and modeling perspectives. The empirical evidence on demand response is scarce, resulting in a limited understanding of many important aspects of demand response, including latency, cycling, and overrides - including acceptable impacts to customer comfort, convenience, and productivity in the new remote work era. We attempt to provide additional information to address this knowledge gap by sharing early results from the 46-townhome testbed located in Atlanta, GA. We report our findings from the first three months of experimental work. These focus on the delays associated with device status updates, characteristics of user overrides of control signals, and the share of devices available for demand response. We also provide some information about the duration of demand response events and a discussion of some properties of the testbed neighborhood.

Tsybina, Eve↗

Autonomous Anomaly Detection for MPC Forecasts of HVAC Systems in Residential Communities

The use of residential heating, ventilation, and air conditioning (HVAC) to shift peak demand or provide ancillary services is a potential solution in the presence of older grids and distributed renewables. However, to ensure the efficient use of devices, utilities need to accurately forecast the load and adopt error correction schemes when necessary. While significant theoretical research exists in the area of predictive control of HVAC, little experimental evidence exists. The lack of experimental data in turn causes researchers to be unprepared for unsystematic errors which emerge due to the higher complexity of the data generating process. This study offers an anomaly detection methodology that uses unsupervised machine learning algorithms to detect and isolate these errors with different forecast error ranges. The results of anomaly detection procedure can then be used for error correction and would eventually help develop better predictive controllers. The methodology is tested using real world data from a smart neighborhood that currently operates in Atlanta. GA.

Lebakula, Viswadeep↗

A Three-Tier Incremental Approach for Development of Smart Corridor Digital Twins

Development of an arterial smart corridor digital twin requires the integration of real time data streams, data storage, and simulation model execution. This process may be complex, time consuming, and susceptible to errors. To aid in smart corridor digital twin development this paper seeks to provide a framework, best practices, and development guidance. As such, a three-tier incremental approach to smart corridor digital twin development is presented. The paper highlights practical issues in digital twin construction along with key data challenges based on experiences from the development of digital twins for two large Smart Corridor deployments, one in Chattanooga, Tennessee, and the other in Atlanta, Georgia. The presented three-tier incremental approach includes: 1) development of a prepopulated offline simulation, 2) development of a pseudo digital twin that is driven by archived data, and 3) integration of real time data streams to create the online digital twin model. The three-tiered approach facilitates conducting multiple trials and scenarios with increasing complexity, allowing for incremental error processing and updating of the digital twin.

Saroj, Abhilasha↗

Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resident Tolerance to Transitional Temperature Deviation in Smart Communities

Choosing the right HVAC system or the right algorithm of implementing demand response may create significant energy and environmental gains while maintaining resident comfort. But these questions are closely related to the concept of user comfort, which in turn requires a reasonable fit between user preferences and temperature setpoints. While setting the temperature right is a well-researched question, systems in transition from one setpoint to another are currently not thoroughly addressed in research. But how tolerant the residents really are if a system spends a large share of time outside of the comfort setpoint. This study gives some early insights on how the deviation of temperature from the setpoint affect perceived resident comfort. We use two weeks of data for a smart neighborhood located in Atlanta, GA. We find that the system spends 20% - 50% of time deviating from the setpoint by more than 1℉. However, we do not find that increasing deviations cause resident complaints or increasing overrides.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗