Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Annular flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Two-Phase Annular Flow in Helical Coil Flow Channels in a Reduced Gravity Environment

A brief review of both single- and two-phase flow studies in curved and coiled flow geometries is first presented. Some of the complexities of two-phase liquid-vapor flow in curved and coiled geometries are discussed, and serve as an introduction to the advantages of observing such flows under a low-gravity environment. The studies proposed -- annular two-phase air-water flow in helical coil flow channels are described. Objectives of the studies are summarized.

Keshock, Edward G.↗

A numerical investigation of supersonic strut/endwall interactions in annular flow with varying strut thickness

A full 3D Navier-Stokes numerical investigation has been conducted of the shock-wave/boundary-layer flow interactions caused by four diamond-shaped struts, of varying thickness, in an annular duct with Mach 3 core flow and turbulent boundary-layers on both walls. Secondary flows caused by weak-to-strong interactions are examined in the vicinity of a strut which is bounded by curved endwalls. The duct endwall boundary-layer separated for the strongest interaction. The struts studied had maximum thickness-to-chord ratios of 0.125, 0.188, 0.250, and 0.500. The duct gap height is 0.7 strut chords, the duct inner-to-outer wall radius ratio is 0.7, and the Reynolds number is 3 x 10 exp 5 based on the strut chord length which was held constant for all interactions considered. The effects of strut thickness on the secondary flows are discussed, including: trajectories for the leading and trailing edge horseshoe vortices, strut/endwall corner vortices, and boundary-layer separation. The line of coalescence discussed in the literature, previously ascribed to boundary-layer separation, is shown to be caused by the leading edge horseshoe vortex convecting along the shock front.

Williams, K. E.↗

Annular flow in rod-bundle: Effect of spacer on disturbance waves

A high-speed camera technique is used to study the effect of spacers on the disturbance waves present in annular two-phase flow within a rod-bundle geometry. Images obtained using a backlight configuration to visualize the spacer-wave interactions at the micro-scale resolution (in time and space) are discussed. This paper also presents additional images obtained using a reflected light configuration which provides new observations of the disturbance waves. These images show the separation effect caused by the spacer on the liquid film in which the size of generated liquid droplets can be controlled by the gas superficial velocity. Furthermore, the data confirm that the spacer breaks the circumferential coherent structures of the waves.

disturbance waves↗

Compliant Metal Enhanced Convection Cooled Reverse-Flow Annular Combustor

A joint Army/NASA program was conducted to design, fabricate, and test an advanced, reverse-flow, small gas turbine combustor using a compliant metal enhanced (CME) convection wall cooling concept. The objectives of this effort were to develop a design method (basic design data base and analysis) for the CME cooling technique and tben demonstrate its application to an advanced cycle, small, reverse-flow combustor with 3000 F (1922 K) burner outlet temperature (BOT). The CME concept offers significant improvements in wall cooling effectiveness resulting in a large reduction in cooling air requirements. Therefore, more air is available for control of burner outlet temperature pattern in addition to the benefit of improved efficiency, reduced emissions, and smoke levels. Rig test results demonstrated the benefits and viability of the CME concept meeting or exceeding the aerothermal performance and liner wall temperature characteristics of similar lower temperature-rise combustors, achieving 0.15 pattern factor at 3000 F (1922 K) BOT, while utilizing approximately 80 percent less cooling air than conventional, film-cooled combustion systems.

Paskin, Marc D.↗

Investigation of core-annular flow in an industrial scale circulating fluidized bed riser with electrical capacitance volume tomography (ECVT)

There is a paucity of riser data for industrial scale units, particularly with regard to the solids fraction. This is especially true for detailed spatially distributed values. To alleviate this problem, NETL installed a 0.445 m tall electrical capacitance volume tomography (ECVT) sensor 9.66 m from the gas distributor of its industrial size (15.45 m high and 0.3 m diameter) circulating fluidized bed (CFB) cold model. A series of tests were conducted to investigate the gas-solid flow behavior using high density polyethylene (PPE) solids. Static electricity was successfully minimized using Larostat and humidification. Time averaged radial solid fractions profiles are presented and discussed. The time and spatially averaged solid fractions measured by the ECVT agree well with estimates from the pressure drop. The annular thickness was measured and found to increase with increases in the solids flow rate and decrease with increases in the gas velocity. Comparisons of the annular thickness and solids fraction as determined from the ECVT unit were compared to existing correlations. In conclusion, the average error ranged from 13% to 275% which is not surprising since the literature correlations were developed from data on much smaller units and for significantly different particles.

42 ENGINEERING↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat Transfer and Pressure Drop in Concentric Annular Flows of Binary Inert Gas Mixtures

Studies of heat transfer and pressure drop of binary inert gas mixtures flowing through smooth concentric circular annuli, tubes with fully developed velocity profiles, and constant heating rate are described. There is a general lack of agreement among the constant property heat transfer correlations for such mixtures. No inert gas mixture data exist for annular channels. The intent of this study was to develop highly accurate and benchmarked pressure drop and heat transfer correlations that can be used to size heat exchangers and cores for direct gas Brayton nuclear power plants. The inside surface of the annular channel is heated while the outer surface of the channel is insulated. Annulus ratios range 0.5 < r* < 0.83. These smooth tube data may serve as a reference to the heat transfer and pressure drop performance in annuli, tubes, and channels having helixes or spacer ribs, or other surfaces.

Reid, R. S.↗

Sound fields in a lined annular flow duct with lined radial splitters

High attenuation in the inlet duct of fan-jet engines is limited mainly because of two factors: the duct length is short and the frequency is high giving rise to a large duct width to wavelength ratio. Lined radial splitters may be installed. In this configuration not only is the absorbing surface area increased, the acoustic propagation properties in each of the segmented ducts are different to those in a cylindrical or annular duct without radial splitters. Such differences in properties can be used to advantage for mismatching the acoustic source. A lower order spinning mode must propagate as a higher order (integral or fractional) spinning mode. Cut-off phenomena may also be used to advantage. A theoretical modal analysis is made of the sound inside one segment of the annular duct with lined radial splitters.

Mungur, P.↗

Lateral particle size segregation in a riser under core annular flow conditions due to the Saffman lift force

It has been observed under certain flow conditions that there is a measured increase in fine particle concentration at the center of the circulating fluidized bed riser just below the exit to the cyclone. It is hypothesized that the Saffman force might be responsible for this phenomena. Furthermore, this research paper discusses the likelihood of the existence of “Saffman” forces, or lift due to viscous shear, in cylindrical, circulating fluidized bed (CFB) risers operating in the core annular regime.

01 COAL, LIGNITE, AND PEAT↗

Radiated sound field measurements from an annular flow duct facility

A series of measured radiated field patterns correlated with defined in-duct conditions is presented, along with a second series of radiation measurements for multiple mode propagation, with individual mode amplitudes and phases at duct termination as well as with angular positions of higher-order stationary duct modes relative to the plane of the radiated field measurement. Though incomplete, these experimental data should prove useful for comparisons with theoretical predictions in testing analytical procedures and prediction techniques.

Plumblee, H. E.↗

A new linearized theory of laminar film condensation of two phase annular flow in a capillary pumped loop

Future large space based facilities, such as Space Station, will require energy management systems capable of transporting tens of kilowatts of heat over a hundred meters or more. This represents better than an order of magnitude improvement over current technology. Two-phase thermal systems are currently being developed to meet this challenge. Condensation heat transfer plays a very important role in this system. The present study attempts an analytic solution to the set of linearized partial differential equations. The axial velocity and temperature functions were found to be Bessel functions which have oscillatory behavior. This result agrees qualitatively with the experimental evidence from tests at both NASA Goddard Space Flight Center and elsewhere.

Hsu, Y. K.↗

Secondary flows in annular cascades and effects on flow in inlet guide vanes

Qualitative discussion is presented of the general nature of secondary flows in stationary annular cascades with thin wall boundary layers and radial design variation of circulation. Deviations from ideal mean outlet flows (based on blade-element performance) exist in potential-flow region of vanes because of conditions imposed by end-wall boundaries, displacement of wall boundary layers toward blade suction surfaces, and irrotationality requirement. As a consequence of existence of nonuniform radial flow across blade spacing, it may not generally be possible to obtain an arbitrarily specified design variation of the turning angle along the radial height of a blade row. Quantitative turning angle corrections due to effects of secondary flows in axial-flow compressor inlet guide vanes were obtained from induced deflections of a superimposed vortex system in conjunction with an empirically determined correlation factor.

CASCADES, EXPERIMENT↗

Studies of Two-Phase Gas-Liquid Flow in Microgravity

Two-phase gas-liquid flows are expected to occur in many future space operations. Due to a lack of buoyancy in the microgravity environment, two-phase flows are known to behave differently than those in earth gravity. Despite these concerns, little research has been conducted on microgravity two-phase flow and the current understanding is poor. This dissertation describes an experimental and modeling study of the characteristics of two-phase flows in microgravity. An experiment was operated onboard NASA aircraft capable of producing short periods of microgravity. In addition to high speed photographs of the flows, electronic measurements of void fraction, liquid film thickness, bubble and wave velocity, pressure drop and wall shear stress were made for a wide range of liquid and gas flow rates. The effects of liquid viscosity, surface tension and tube diameter on the behavior of these flows were also assessed. From the data collected, maps showing the occurrence of various flow patterns as a function of gas and liquid flow rates were constructed. Earth gravity two-phase flow models were compared to the results of the microgravity experiments and in some cases modified. Models were developed to predict the transitions on the flow pattern maps. Three flow patterns, bubble, slug and annular flow, were observed in microgravity. These patterns were found to occur in distinct regions of the gas-liquid flow rate parameter space. The effect of liquid viscosity, surface tension and tube diameter on the location of the boundaries of these regions was small. Void fraction and Weber number transition criteria both produced reasonable transition models. Void fraction and bubble velocity for bubble and slug flows were found to be well described by the Drift-Flux model used to describe such flows in earth gravity. Pressure drop modeling by the homogeneous flow model was inconclusive for bubble and slug flows. Annular flows were found to be complex systems of ring-like waves and a substrate film. Pressure drop was best fitted with the Lockhart- Martinelli model. Force balances suggest that droplet entrainment may be a large component of the total pressure drop.

Bousman, William Scott↗

Termination unit

Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗