Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improvements in the Calibration of the NOAA-20 VIIRS Day-Night Band Low Gain Stage Using a Solar Diffuser

We aim to introduce and demonstrate several improvements that are applied to the on-orbit solar diffuser (SD) calibration of the day-night band (DNB) low gain stage (LGS) of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the NOAA-20 satellite. The most important improvement is the expansion of the angular range, referred to “sweet spot”, from 4° to 7.8° in order to increase the number of fully-illuminated scans considered for the SD calculation. The increase in scan number enables the completion of on-orbit calibration using the SD within one orbit, compared with the multiple orbits approach, which is required in the current standard approach applied in operational DNB LGS calibration coefficients look-up tables (LUTs) updates. The NOAA-20 DNB LGS calibration coefficients have been derived with the new methodology and the results show a more stable, smoother, and less noisy trend when compared with the current standard approach. The results also demonstrate that the NOAA-20 VIIRS DNB overall on-orbit performance has been very stable.

NOAA-20↗

Speed control device for a heavy duty shaft

A speed control device is characterized by a reference speed shaft spatially related to a heavy duty shaft, a drive train for driving the reference speed shaft at a constant angular velocity, a drive train for driving the heavy duty shaft at a variable angular velocity and a speed control assembly for continuously comparing the angular velocity of the heavy duty shaft with the angular velocity of the reference speed shaft. A brake assembly is connected to the heavy duty shaft and is adapted to respond to errors in the angular velocity of the heavy duty shaft in order to reduce the angular velocity of the heavy duty shaft to that of the reference speed shaft.

Ford, A. G.↗

COBE nonspinning attitude propagation

The Cosmic Background Explorer (COBE) spacecraft will exhibit complex attitude motion consisting of a spin rate of approximately -0.8 revolution per minute (rpm) about the x-axis and simultaneous precession of the spin axis at a rate of one revolution per orbit (rpo) about the nearly perpendicular spacecraft-to-Sun vector. The effect of the combined spinning and precession is to make accurate attitude propagation difficult and the 1-degree (3 sigma) solution accuracy goal problematic. To improve this situation, an intermediate reference frame is introduced, and the angular velocity divided into two parts. The nonspinning part is that which would be observed if there were no rotation about the X-axis. The spinning part is simply the X-axis component of the angular velocity. The two are propagated independently and combined whenever the complete attitude is needed. This approach is better than the usual one-step method because each of the two angular velocities look nearly constant in their respective reference frames. Since the angular velocities are almost constant, the approximations made in discrete time propagation are more nearly true. To demonstrate the advantages of this nonspinning method, attitude is propagated as outlined above and is then compared with the results of the one-step method. Over the 100-minute COBE orbit, the one-step error grows to several degrees while the nonspinning error remains negligible.

Chu, D.↗

Elastic scattering measurements for the system {sup 7}Be+{sup 28}Si at 17.2 MeV

Elastic scattering of {sup 7}Be+{sup 28}Si was studied at several near barrier energies for probing the energy dependence of the optical potential. Our analysis at 17.2 MeV will be presented in this article and discussed, in terms of Continuum Coupled Channel Calculations (CDCC). This research is part of a long term plan concerning the energy dependence of the optical potential for weakly bound projectiles, at near barrier energies and for probing the potential threshold anomaly. The experiment took place at the EXOTIC facility - Laboratori Nationali di Legnaro (LNL), and refers to an angular distribution measurement, using the detector array EXPADES (Exotic Particle Detection System). Results at 9 MeV (Rutherford region) were also analyzed and were used for estimating the solid angle. Our analysis for other energies is under process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higher-order multipole amplitudes in charmonium radiative transitions

Using 24x10{sup 6} {psi}{sup '}{identical_to}{psi}(2S) decays in CLEO-c, we have searched for higher multipole admixtures in electric-dipole-dominated radiative transitions in charmonia. We find good agreement between our data and theoretical predictions for magnetic quadrupole (M2) amplitudes in the transitions {psi}{sup '}{yields}{gamma}{chi}{sub c1,c2} and {chi}{sub c1,c2}{yields}{gamma}J/{psi}, in striking contrast to some previous measurements. Let b{sub 2}{sup J} and a{sub 2}{sup J} denote the normalized M2 amplitudes in the respective aforementioned decays, where the superscript J refers to the angular momentum of the {chi}{sub cJ}. By performing unbinned maximum likelihood fits to full five-parameter angular distributions, we found the following values of M2 admixtures for J{sub {chi}}=1: a{sub 2}{sup J={sup 1}}=(-6.26{+-}0.63{+-}0.24)x10{sup -2} and b{sub 2}{sup J={sup 1}}=(2.76{+-}0.73{+-}0.23)x10{sup -2}, which agree well with theoretical expectations for a vanishing anomalous magnetic moment of the charm quark. For J{sub {chi}}=2, if we fix the electric octupole (E3) amplitudes to zero as theory predicts for transitions between charmonium S states and P states, we find a{sub 2}{sup J={sup 2}}=(-9.3{+-}1.6{+-}0.3)x10{sup -2} and b{sub 2}{sup J={sup 2}}=(1.0{+-}1.3{+-}0.3)x10{sup -2}. If we allow for E3 amplitudes we find, with a four-parameter fit, a{sub 2}{sup J={sup 2}}=(-7.9{+-}1.9{+-}0.3)x10{sup -2}, b{sub 2}{sup J={sup 2}}=(0.2{+-}1.4{+-}0.4)x10{sup -2}, a{sub 3}{sup J={sup 2}}=(1.7{+-}1.4{+-}0.3)x10{sup -2}, and b{sub 3}{sup J={sup 2}}=(-0.8{+-}1.2{+-}0.2)x10{sup -2}. We determine the ratios a{sub 2}{sup J={sup 1}}/a{sub 2}{sup J={sup 2}}=0.67{sub -0.13}{sup +0.19} and a{sub 2}{sup J={sup 1}}/b{sub 2}{sup J={sup 1}}=-2.27{sub -0.99}{sup +0.57}, where the theoretical predictions are independent of the charmed quark magnetic moment and are a{sub 2}{sup J={sup 1}}/a{sub 2}{sup J={sup 2}}=0.676{+-}0.071 and a{sub 2}{sup J={sup 1}}/b{sub 2}{sup J={sup 1}}=-2.27{+-}0.16.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-axis leveling detector system

Electro-mechanical device for measuring tilt angles in order to establish level base without optical reference is described. Angular displacement is detected by movement of bubble in conducting fluid containing electrode network. Electrical signal causes compensation for small movements in horizontal and vertical planes.

Weiner, L.↗

Development of a Magneto-Resistive Angular Position Sensor for Space Mechanisms

Magnetic microsystems in the form of magneto-resistive (MR) sensors are firmly established in automobiles and industrial applications. They are used to measure travel, angle, electrical current, or magnetic fields. MR technology opens up new sensor possibilities in space applications and can be an enabling technology for optimal performance, high robustness and long lifetime at reasonable costs. In some science missions, the technology is already applied, however, the designs are proprietary and case specific, for instance in case of the angular sensors used for JPL/NASA's Mars rover Curiosity [1]. Since 2013 HTS GmbH and Sensitec GmbH have teamed up to develop and qualify a standardized yet flexible to use MR angular sensor for space mechanisms. Starting with a first assessment study and market survey performed under ESA contract, a very strong industry interest in novel, contactless position measurement means was found. Currently a detailed and comprehensive development program is being performed by HTS and Sensitec. The objective of this program is to advance the sensor design up to Engineering Qualification Model level and to perform qualification testing for a representative space application. The paper briefly reviews the basics of magneto-resistive effects and possible sensor applications and describes the key benefits of MR angular sensors with reference to currently operational industrial and space applications. The key applications and specification are presented and the preliminary baseline mechanical and electrical design will be discussed. An outlook on the upcoming development and test stages as well as the qualification program will be provided.

Hahn, Robert↗

Two-particle angular correlations in e + e - collisions to hadronic final states in two reference coordinates at Belle

We present the analysis of two-particle angular correlations using coordinate systems defined with the conventional beam axis and the event thrust axis. We propose the latter as a good representation for the correlation structure interpretation in the e + e - collision system. The e + e - collisions to hadronic final states at center-of-mass energies of $\sqrt{s}$ = 10.52 GeV and 10.58 GeV are recorded by the Belle detector at KEKB. In this paper, results on the first dataset are supplementary to the previous Belle publication [1]. At the same time, the latter is the first two-particle correlation measurement at collision energy on the Υ(4S) resonance and is sensitive to its decay products. Measurements are reported as a function of the charged-particle multiplicity. Finally, a qualitative understanding of the correlation structure is discussed using a combination of Monte Carlo simulations and experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The multichannel astrometric photometer and atmospheric limitations in the measurement of relative positions

The operational Multichannel Astrometric Photometer (MAP) now in use in the Allegheny Observatory astrometric program is the culmination of a decade of design and development effort. A detailed description of the system and its related software is followed by analysis of data acquired in four stellar regions. The study indicates an accuracy (in the sense of conformity to the best model), per night, for stars of the eighth magnitude or brighter, of 0.003 arcsec or better. These data points each have approximately twice the precision of the annual normal points obtained in our photographic program. Accuracy is shown to depend on: (1) the photon-count rate of the target star (it follows that the number of photons from the reference frame is also in important factor), (2) the duration of the observation, (3) the angular size of the reference frame, and (4) the quality of the astronomical seeing. Since (4) and, to a lesser extent, (1) involve the atmospheric characteristics at the time of observation, the probable performance at more favorable sites is discussed briefly.

Gatewood, George D.↗

Effects of visual reference on adaptation to motion sickness and subjective responses evoked by graded cross-coupled angular accelerations

Three groups of 10 subjects each were exposed to stepwise increments of cross coupled angular accelerations in three visual modes: internal visual reference (IVR), external visual reference (EVR), and vision absent (VA). The subjects in the IVR condition required significantly greater amounts of stimulus exposure to neutralize their illusory subjective reactions. They also suffered a greater loss of well-being and a more marked incidence of motion sickness than did subjects in the EVR and VA conditions. The same 30 subjects were reexposed to the same graded cross coupled stimulation 1 week later. This time, however, all the subjects were tested under only the IVR condition. All three groups showed some positive transfer of adaptation, but only the IVR-IVR combination required significantly fewer head motions to achieve the same level of adaptation on the second occasion. Taken overall, however, the most efficient and least disturbing route to adaptation at the completion of the second test was via the VA-IVR combination.

Reason, J. T.↗

Holography with a neutron interferometer

We use a Mach-Zehnder interferometer to perform neutron holography of a spiral phase plate. The object beam passes through a spiral phase plate, acquiring the phase twist characteristic of orbital angular momentum states. The reference beam passes through a fused silica prism, acquiring a linear phase gradient. The resulting hologram is a fork dislocation image, which could be used to reconstruct neutron beams with various orbital angular momenta. This work paves the way for novel applications of neutron holography, diffraction and imaging.

47 OTHER INSTRUMENTATION↗

Skylab attitude control and angular momentum desaturation with one double-gimbaled control moment gyro

In case two control moment gyros fail, attitude control of Skylab can be maintained with the thruster attitude control system. This results, however, in a severely increased fuel consumption, depleting the fuel in a few days. Therefore, an alternate concept was developed which does not have large fuel consumption under any circumstances. In this concept the attitude reference is commanded to oscillate in the orbital plane with twice the orbital frequency and the remaining control moment gyro controls about orbital north and about the minimum moment-of-inertia axis, while the thruster attitude control system controls rate only about the remaining axis. This rate control in conjunction with the restoring torque due to the gravity gradient will keep bounded the excursion of the minimum moment-of-inertia axis out of the orbital plane. This alternate concept has the additional advantage that it needs no information on the principal moment-of-inertia axes misalignment and is completely insensitive to star tracker failure. Proper phasing of the attitude reference oscillation even allows angular momentum desaturation, which is responsible for the insensitivity of the thruster fuel consumption to unknown disturbances, like vent torques and magnetic torques.

Kennel, H. F.↗

Angular-momentum projection in coupled-cluster theory: Structure of 34 Mg

Single- reference coupled-cluster theory is an accurate and affordable computational method for the nuclear many-body problem. For open-shell nuclei, the reference state typically breaks rotational invariance and angular momentum must be restored as a good quantum number. We perform angular-momentum projection after variation and employ the disentangled coupled-cluster formalism and a Hermitian approach. We compare our results with benchmarks for 8 Be and 20 Ne using a two-nucleon interaction from chiral effective field theory and for pf-shell nuclei within the traditional shell model. We compute the rotational band in the exotic nucleus 34 Mg and find agreement with data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ASTROMETRY WITH THE HUBBLE SPACE TELESCOPE: TRIGONOMETRIC PARALLAXES OF PLANETARY NEBULA NUCLEI NGC 6853, NGC 7293, ABELL 31, AND DeHt 5

We present absolute parallaxes and relative proper motions for the central stars of the planetary nebulae NGC 6853 (The Dumbbell), NGC 7293 (The Helix), Abell 31, and DeHt 5. This paper details our reduction and analysis using DeHt 5 as an example. We obtain these planetary nebula nuclei (PNNi) parallaxes with astrometric data from Fine Guidance Sensors FGS 1r and FGS 3, white-light interferometers on the Hubble Space Telescope. Proper motions, spectral classifications and VJHKT{sub 2}M and DDO51 photometry of the stars comprising the astrometric reference frames provide spectrophotometric estimates of reference star absolute parallaxes. Introducing these into our model as observations with error, we determine absolute parallaxes for each PNN. Weighted averaging with previous independent parallax measurements yields an average parallax precision, {sigma}{sub {pi}}/{pi} = 5%. Derived distances are: d {sub NGC6853} = 405{sup +28} {sub -25} pc, d {sub NGC7293} = 216{sup +14} {sub -12} pc, d {sub Abell31} = 621{sup +91} {sub -70} pc, and d {sub DeHt5} = 345{sup +19}{sub -17} pc. These PNNi distances are all smaller than previously derived from spectroscopic analyses of the central stars. To obtain absolute magnitudes from these distances requires estimates of interstellar extinction. We average extinction measurements culled from the literature, from reddening based on PNNi intrinsic colors derived from model SEDs, and an assumption that each PNN experiences the same rate of extinction as a function of distance as do the reference stars nearest (in angular separation) to each central star. We also apply Lutz-Kelker bias corrections. The absolute magnitudes and effective temperatures permit estimates of PNNi radii through both the Stefan-Boltzmann relation and Eddington fluxes. Comparing absolute magnitudes with post-AGB models provides mass estimates. Masses cluster around 0.57 M{sub odot}, close to the peak of the white dwarf mass distribution. Adding a few more PNNi with well-determined distances and masses, we compare all the PNNi with cooler white dwarfs of similar mass, and confirm, as expected, that PNNi have larger radii than white dwarfs that have reached their final cooling tracks.

79 ASTRONOMY AND ASTROPHYSICS↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmon Enhanced Photoemission

Next generation ultrabright light sources will operate at megahertz repetition rates with temporal resolution in the attosecond regime. For an X-Ray Free Electron Laser (FEL) to operate at such repetition rate requires a high quantum efficiency (QE) cathode to produce electron bunches of 300 pC per 1.5 μJ incident laser pulse. Semiconductor photocathodes have sufficient QE in the ultraviolet (UV) and the visible spectrum, however, they produce picosecond electron pulses due to the electron-phonon scattering. On the other hand, metals have two orders of magnitude less QE, but can produce femtosecond pulses, that are required to form the optimum electron distribution for high efficiency FEL operation. In this work, a novel metallic photocathode design is presented, where a set of nano-cavities is introduced on the metal surface to increase its QE to meet the FEL requirements, while maintaining the fast time response. Photoemission can be broken up into three steps: (1) photon absorption, (2) electron transport to the surface, and (3) crossing the metal-vacuum barrier. The first two steps can be improved by making the metal completely absorbing and by localizing the fields closer to the metal surface, thereby reducing the electron travel distance. Both of these effects can be achieved by coupling the incident light to an electron density wave on the metal surface, represented by a quasi-particle, the Surface Plasmon Polariton (SPP). The photoemission then becomes a process where the photon energy is transferred to an SPP and then to an electron. The dispersion relation for the SPP defines the region of energies where such process can occur. For example, for gold, the maximum SPP energy is 2.4 eV, however, the work function is 5.6 eV, therefore, only a fourth order photoemission process is possible. In such process, four photons excite four plasmons that together excite only one electron. The yield of such non-linear process depends strongly on the light intensity. In this work, the structure consisted of rectangular nano-grooves (NGs) arranged in a subwavelength grating on a metal surface is presented that provides a dramatic increase in the metal’s absorption, field localization, and field enhancement. When light is polarized perpendicular to the orientation of the grooves a standing SPP wave is excited along the vertical walls in the NGs, that act as Fabry-Perot resonators. By adjusting the geometry of the NGs and the period of the subwavelength grating the resonance can be fine tuned to a desired position, for example, the laser fundamental wavelength, anywhere from the UV to the near infrared (NIR). Two types of gratings are presented: (a) a gold grating with period of 600 nm, and (b) an aluminum-gold grating with a period of 100 nm; both with resonance at 720 nm. In each case, strong on-resonance absorption was observed, with over 98% for grating (b). Unlike the grating-coupled SPP waves, where the angle is well defined by the momentum matching condition, the resonant NGs allow coupling to the standing modes at a range of angles of incidence, referred to as the angular bandwidth. A new model for the on-resonance absorption based on the ensamble action of the NGs is presented that serves as the basis for a design of an NG grating with an ultrawide spectral as well as angular bandwidth. For sample (b), the angular bandwidth is 80 degrees, corresponding to an opening angle of 160 degrees. The photoemission enhancement for such a grating was measured to be seven orders of magnitude for a four-photon photoemission. This is an incredible result demonstrating the power of the plasmonic grating presented, which is an efficient light trapper and field enhancer for a non-linear processes. These results demonstrate that the metal photocathode prepared with a NG grating on the metal surface will provide sufficient pulse charge driven by a 1 μJ 15fs pulsed laser at 800 nm for the optimum FEL operation.

74 ATOMIC AND MOLECULAR PHYSICS↗