Design criteria for reflection polarizers and analyzers in the vacuum ultraviolet

Reflection polarizers and analyzers for the extreme UV spectral region are discussed. The conditions for optimum polarization are presented, and the polarization characteristics of a number of metal coatings, including gold and some of the platinum metals, are given. The performance of three- and four-mirror polarizers, using these metal coatings, is discussed. The properties required of a polarization analyzer are presented, and the performance of single and three- and four-reflection analyzers are discussed in terms of the optical properties of coating materials that might be useful for analyzers.

Hunter, W. R.↗

Detector verifier for circuit analyzers

Economical tool checks operation of automatic circuit analyzer. Each loop is addressed directly from analyzer console by switching internal analyzer bridge to resistance equal that of connecting cable plus specified limiting test value. Procedure verifies whether detected faults in circuit under test are actually due to analyzer malfunction. Standard-length universal test cables make it possible to shift detector tool from cable to cable without resistance compensation.

Pope, D. L.↗

Testing Evaluation of the Electrochemical Organic Content Analyzer

The breadboard electrochemical organic content analyzer was evalauted for aerospace applications. An awareness of the disadvantages of expendables in some systems resulted in an effort to investigate ways of reducing the consumption of the analyzer's electrolyte from the rate of 5.17 kg/30 days. It was found that the electrochemical organic content analyzer can result in an organic monitor in the water quality monitor having a range of 0.1 to 100 mg/1 total organic carbon for a large number of common organic solutes. In a flight version it is anticipated the analyzer would occupy .0002 cu m, weigh 1.4 kg, and require 10 W or less of power. With the optimum method of injecting electrolyte into the sample (saturation of the sample with a salt) it would expend only 0.04 kg of electrolyte during 30 days of continuous operation.

Davenport, R. J.↗

Molecular wake shield gas analyzer

Techniques for measuring and characterizing the ultrahigh vacuum in the wake of an orbiting spacecraft are studied. A high sensitivity mass spectrometer that contains a double mass analyzer consisting of an open source miniature magnetic sector field neutral gas analyzer and an identical ion analyzer is proposed. These are configured to detect and identify gas and ion species of hydrogen, helium, nitrogen, oxygen, nitric oxide, and carbon dioxide and any other gas or ion species in the 1 to 46 amu mass range. This range covers the normal atmospheric constituents. The sensitivity of the instrument is sufficient to measure ambient gases and ion with a particle density of the order of one per cc. A chemical pump, or getter, is mounted near the entrance aperture of the neutral gas analyzer which integrates the absorption of ambient gases for a selectable period of time for subsequent release and analysis. The sensitivity is realizable for all but rare gases using this technique.

Hoffman, J. H.↗

Analysis of counting errors in the phase/Doppler particle analyzer

NASA is investigating the application of the Phase Doppler measurement technique to provide improved drop sizing and liquid water content measurements in icing research. The magnitude of counting errors were analyzed because these errors contribute to inaccurate liquid water content measurements. The Phase Doppler Particle Analyzer counting errors due to data transfer losses and coincidence losses were analyzed for data input rates from 10 samples/sec to 70,000 samples/sec. Coincidence losses were calculated by determining the Poisson probability of having more than one event occurring during the droplet signal time. The magnitude of the coincidence loss can be determined, and for less than a 15 percent loss, corrections can be made. The data transfer losses were estimated for representative data transfer rates. With direct memory access enabled, data transfer losses are less than 5 percent for input rates below 2000 samples/sec. With direct memory access disabled losses exceeded 20 percent at a rate of 50 samples/sec preventing accurate number density or mass flux measurements. The data transfer losses of a new signal processor were analyzed and found to be less than 1 percent for rates under 65,000 samples/sec.

Oldenburg, John R.↗

A wideband, high-resolution spectrum analyzer

A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple signal detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.

Quirk, M. P.↗

A wide-band high-resolution spectrum analyzer

A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.

Quirk, Maureen P.↗

A Nanometer Aerosol Size Analyzer (nASA) for Rapid Measurement of High-Concentration Size Distributions

We have developed a fast-response Nanometer Aerosol Size Analyzer (nASA) that is capable of scanning 30 size channels between 3 and 100 nm in a total time of 3 seconds. The analyzer includes a bipolar charger (P0210), an extended-length Nanometer Differential Mobility Analyzer (Nano-DMA), and an electrometer (TSI 3068). This combination of components provides particle size spectra at a scan rate of 0.1 second per channel free of uncertainties caused by response-time-induced smearing. The nASA thus offers a fast response for aerosol size distribution measurements in high-concentration conditions and also eliminates the need for applying a de-smearing algorithm to resulting data. In addition, because of its thermodynamically stable means of particle detection, the nASA is useful for applications requiring measurements over a broad range of sample pressures and temperatures. Indeed, experimental transfer functions determined for the extended-length Nano-DMA using the Tandem Differential Mobility Analyzer (TDMA) technique indicate the nASA provides good size resolution at pressures as low as 200 Torr. Also, as was demonstrated in tests to characterize the soot emissions from the J85-GE engine of a T38 aircraft, the broad dynamic concentration range of the nASA makes it particularly suitable for studies of combustion or particle formation processes. Further details of the nASA performance as well as results from calibrations, laboratory tests and field applications are presented.

Han, Hee-Siew↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

Harmonic distortion analyzer speeds setup of magnetic tape recorders

Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

Tinari, D. F.↗

Pseudotachometer for mobile metabolic analyzer

Metabolic analyzer determines a patient's walking or ambulation speed and simultaneously measures his metabolic parameters. Analyzer is designed to move at some preselected human ambulation speed. During test, patient is connected to system and follows analyzer closely while his metabolic data is being monitored.

Currie, J. R.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Prototype partial one-third octave band spectrum analyzer for acoustic, vibration and other wideband data for flight applications

The design refinement of a compact frequency analyzer for measurement and analysis on board flight vehicles is discussed. The analyzer has been constructed in a partial one-third octave band configuration with six filters and detectors spaced by the square root of 10 from 316 Hz to 100,000 Hz and a broadband detector channel. The analyzer has been tested over a temperature range of 40 to 120 F at a pressure of one atmosphere, and at a temperature of 75 F at an absolute pressure of 0.000001 torr, and has demonstrated at least 60 db of dynamic range.

Source record↗

The Pioneer 10 plasma analyzer results at Jupiter

Results are reported for the Pioneer 10 plasma-analyzer experiment at Jupiter. The analyzer system consisted of dual 90-deg quadrispherical electrostatic analyzers, multiple charged-particle detectors, and attendant electronics; it was capable of determining the incident plasma-distribution parameters over the energy range from 100 to 18,000 eV for protons and from approximately 1 to 500 eV for electrons. Data are presented on the interaction between the solar wind and the Jovian magnetosphere, the interplanetary ion flux, observations of the magnetosheath plasma, and traversals of the bow shock and magnetopause. Values are estimated for the proton isotropic temperature, number density, and bulk velocity within the magnetosheath flow field as well as for the beta parameter, ion number density, and magnetic-energy density of the magnetospheric plasma. It is argued that Jupiter has a reasonably thick magnetosphere somewhat similar to earth's except for the vastly different scale sizes involved.

Wolfe, J. H.↗

Analysis of a discrete spectrum analyzer for the detection of radio frequency interference

As the radio frequency spectrum becomes increasingly overcrowded, interference with mission-critical DSN operations is rising at an alarming rate. To alleviate this problem the DSN is developing a wideband surveillance system for on-site detection and identification of potential sources of radio frequency interference (RFI), which will complement the existing frequency coordination activities. The RFI monitoring system is based on a wideband, multi-look discrete spectrum analyzer operating on fast Fourier transform principles. An extensive general statistical analysis is presented of such spectrum analyzers and derives threshold detection performance formulas for signals of interest. These results are then applied to the design of the RFI spectrum analyzer under development.

Levitt, B. K.↗

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.↗

Experimental solar radio spectrum analyzer (50-100 MHz)

Summarized is the work carried out under a NASA Grant covering the period 15 October 1977 to 14 January 1978. The grant provided funds for the acquisition of an experimental radio spectrum analyzer covering the band 50-100 MHz, for use in a program of solar radio observations. Components for the experimental analyzer were duly obtained, and the system was assembled, checked, and put into operation in early February 1978. The analyzer is working in an entirely satisfactory manner and, from the time that it has been put into operation, it has played an important part in the on-going research programs in solar radio astronomy being conducted.

Maxwell, A.↗