Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Force”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Emerging Technologies Review: Water Reuse Systems for Cooling Tower Applications

This report explores the concept of water reuse systems for cooling tower water makeup, specifically focusing on the use of alternative water sources, and the viability of these systems for Air Force installations and operations. Cooling is a critical requirement for DAF operations, and alternative water supplies that enable cooling tower use during a disruption of utility-supplied water increase Air Force resilience. The components of a water reuse system for cooling towers include alternative water supplies, storage, treatment, and distribution in addition to the cooling tower itself. Alternative water sources are not derived from fresh surface water or groundwater and can provide a redundant water supply to utility supply or to fresh water produced on site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Burrowing Owl Survey Report for Sandia National Laboratories: 2025

The Burrowing Owl Survey Report for Sandia National Laboratories: 2025 provides data and analysis on occupancy surveys that were conducted during the 2025 survey season. The surveys were conducted in partnership with Kirtland Air Force Base’s Natural Resource Program and the United States Fish and Wildlife Service to maintain and expand on the long-term dataset on burrowing owls on base. Ecology Program biologists conducted roadside census surveys at survey areas previously identified by Kirtland Air Force Base along with several additional survey areas deemed suitable for occupancy. Remote sensor camera monitoring was also conducted on three nest burrows. In total, 12 breeding pairs of burrowing owls were confirmed in 2025. Several owls were confirmed to have leg bands, indicating previous captures and recurrence of these specific individuals on base. Occupancy surveys on burrowing owls continue to provide valuable information on ecosystem health and can serve to inform future management direction and decisions.

54 ENVIRONMENTAL SCIENCES↗

NbTi_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys niobium-titanium (Nb-Ti). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP), https://github.com/ORNL/ScalableWorkflow_VASP_Calculations. Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Nb and Ti. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on Air Force HPC11 cluster using the VASP 6.5.1. Additional methodology and file structure information is available in the dataset README.txt file.

36 MATERIALS SCIENCE↗

HfTi_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys hafnium-titanium (Hf-Ti). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Hf and Ti. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on Air Force HPC11 cluster using the VASP 6.5.1. Additional methodology and file structure information is available in the dataset README.txt file.

36 MATERIALS SCIENCE↗

TiV_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys titanium-vanadium (Ti-V). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Ti and V. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on Air Force HPC11 cluster using the VASP 6.5.1. Additional methodology and file structure information is available in the dataset README.txt file.

36 MATERIALS SCIENCE↗

Non-stationary precipitation design standards for stormwater infrastructure modernization at USAF installations

The resilience of defense infrastructure systems to a changing climate is critical for national security. Climate induced recurrent flooding is already impacting over 20 U.S. Air Force installations, underscoring the urgency of revisiting precipitation standards and stormwater infrastructure design. Despite growing scientific knowledge and an expanding set of tools for updating outdated precipitation standards based on the assumption of climate stationarity, the adoption of climate informed analyses remain limited in practice. This study utilizes an existing framework to update Intensity (or Depth)-Duration-Frequency (DDF) curves using an ensemble of future climate projections. Change factors in precipitation estimates are derived and applied to six USAF installations across the U.S. The analysis is further extended to evaluate the implications of climate-informed DDFs on stormwater infrastructure performance and flood analysis at Tyndall AFB. Results indicate that the current design precipitation estimates are likely to become obsolete in all six USAF bases by the end of the century. The wide range of change factors across 32 GCM ensembles highlights the need to integrate uncertainty and evolving scientific data into infrastructure planning. The study also finds that the impacts of a changing climate vary spatially and temporally, emphasizing the value of localized analysis for infrastructure decision-making. The work advances ongoing DoD and societal efforts to implement adaptation strategies aimed at enhancing infrastructure resilience.

Intensity-duration-frequency curves↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microgrid Training Session 5: Alternative Solutions to Microgrids

This presentation is the second session of a microgrid training series for the Air Force. Microgrids have advantages over other solutions; however, microgrids have their own costs in terms of finance and operations. This session will help attendees identify alternative solutions to specific issues.

Air Force↗

Nuclear Testing and the Joint Task Force System

During the 1940s, 50s, and early 60s, the United States conducted eight nuclear test operations in the far reaches of the Pacific Ocean. These operations were possible only because of a military command and control organization, the joint task force. Commanded by the Army Navy, and Air Force on a rotating basis, each of the seven JTFs provided the means by which the thousands of ships, planes, material, and personnel were moved over thousands of miles of ocean. The first task force, JTF-1, was created to test the destructive effects of the Fat Man bomb on Naval vessels at Bikini Atoll in the summer of 1946. Commanded by Vice Admiral William “Spike” Blandy, JTF-1 was a purely military operation supported by the MED. Never meant to be a permanent organization, JTF-1 was dissolved soon after completing its mission.

99 GENERAL AND MISCELLANEOUS↗

Field demonstration of a tracer method to track simulated exhaled air trajectories and mixing in three connected rooms with upper-room GUV

We conducted tracer gas experiments in three connected nursery rooms to track simulated exhaled air trajectories and mixing. We emulated exhaled air with a pulse release of ethanol and measured its concentration with 2s time resolution with spatially distributed metal oxide sensors in both the upper and occupied levels of the room. We found that the overhead cooling supply air enhanced vertical air mixing within the rooms. When a room had higher supply airflow than the others, the tracer gas mixed quickly in that room because the supply air dominated the room mixing, thereby isolating it from air mixing with the other rooms. When the forced air system was not operating, the tracer gas resided longer in the upper room before descending. The tracer method also depicts air trajectories from different release locations by detecting the release point and affecting nearby sensors. These experiments support the potential of this method to be used in the field for understanding air trajectories in rooms with upper-room GUV.

Um, Chai Yoon↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TaTi_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-titanium (Ta-Ti). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Hf and Nb. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on Air Force HPC11 cluster using the VASP 6.5.1. Additional methodology and file structure information is available in the dataset README.txt file.

36 MATERIALS SCIENCE↗

Aircraft observations in a tropical supercluster over the equatorial Indian Ocean during MISO-BOB field campaign

The Monsoon Intra-Seasonal Oscillations in the Bay of Bengal (MISO-BOB) field campaign was conducted in the Indian Ocean during the 2018 and 2019 summer monsoon seasons. WC-130J aircraft of the 53rd Weather Reconnaissance Squadron of the US Air Force participated in the campaign in June 2018. The dropsonde observations across a tropical supercluster showed zonal wind variations in association with the structure of the convectively coupled Kelvin wave (CCKW). Within the supercluster, easterlies (westerlies) were observed in the upper (lower) troposphere; this transformation occurred just below the 0° C level. The cold pool had an easterly component throughout, and it was coldest (by 2.5° C) at the center of the supercluster, deepest (~ 1000 m) at its rear/western end, and shallowest (~ 300 m) at the front/eastern end. The level of free convection (LFC) at the front end was at 897 m altitude. At the eastern flank of the supercluster, zonal convergence in the lower troposphere occurred between 500-1500 m levels above the surface between the westerlies within the supercluster and opposing ambient easterlies. Thus, the uplifting of conditionally unstable air parcels above LFC to the east of the supercluster was likely to occur due to this convergence rather than the cold pool influence. Conversely, the western flank of the supercluster had low-level zonal divergence. These observations support the notion of ‘self-similarity’ among the mesoscale convective systems and large-scale waves.

54 ENVIRONMENTAL SCIENCES↗

Technoeconomic assessment of distillation heat transfer intensification using aeroelastically fluttering reeds

Dry cooling, where forced air is the heat transfer medium, is a preferable cooling method in arid locations lacking readily available process water. However, such locations often experience high ambient temperatures that limit the effectiveness of air cooling. The objective of this study is to quantify the economic and energetic benefits of heat transfer intensification via the implementation of aeroelastically fluttering reeds to the air-cooled condenser of a methanol distillation column. Condenser size and performance, regarding recovered methanol and required fan power, is evaluated across condenser operating temperatures (T cond ) from 60 to 62°C and heat transfer coefficients (U) U base –2U base for a range of inlet air temperatures based on ambient temperature data from Yuma, Arizona. Under typical design sizing, condenser capital cost was reduced by 6%–35% (1.3U base –2U base ) and nominal methanol recovery was increased from 0.26% to 0.38% (T cond = 62–60°C). At optimized condenser size, all enhanced U and T cond pairs increase methanol recovery and reduce fan power costs compared to the optimal Ubase reference. Overall, using enhanced heat transfer to maintain condenser temperature under a wider range of inlet conditions, rather than to reduce operation temperature, produces more favorable performance. Methanol price is not a determining factor in which pairs are profitable. Analysis was repeated for a global warming scenario, revealing more valuable improvements under elevated temperatures. Energy savings from condenser improvement to a methanol production system are not significant with respect to an optimized conventional system. Furthermore, unit economic and energetic incentives suggest implementation of fluttering reeds may be justified in other applications.

42 ENGINEERING↗

A step towards the final frontier: Lessons learned from acceptance testing of the first HPE/Cray EX 3000 system at ORNL

Summary In this article, we summarize the deployment of the Air Force Weather (AFW) HPC11 system at Oak Ridge National Laboratory (ORNL) including the process followed to successfully complete acceptance testing of the system. HPC11 is the first HPE/Cray EX 3000 system that has been successfully released to its user community in a federal facility. HPC11 consists of two identical 800‐node supercomputers, Fawbush and Miller, with access to two independent and identical lustre parallel file systems. HPC11 is equipped with Slingshot 10 interconnect technology and relies on the HPE Performance Cluster Manager software for system configuration. ORNL has a clearly defined acceptance testing process used to ensure that every new system deployed can provide the necessary capabilities to support user workloads. We worked closely with HPE and AFW to develop a set of tests that used the United Kingdom's Meteorological Office's Unified Model and 4‐dimensional variational data assimilation. We also included benchmarks and applications from the Oak Ridge Leadership Computing Facility portfolio to fully exercise the HPE/Cray programming environment and evaluate the functionality and performance of the system. Acceptance testing of HPC11 required parallel execution of each element on Fawbush and Miller. In addition, careful coordination was needed to ensure successful acceptance of the newly deployed lustre file systems alongside the compute resources. In this work, we present test results from specific system components and provide an overview of the issues identified, challenges encountered, and the lessons learned along the way.

Melesse Vergara, Verónica G.↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗