Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A review on the state of thermal hydraulics research on air ingress scenarios in High-Temperature Gas-cooled Reactors following a D-LOFC

With the expectation of near-immediate carbon neutrality, widespread implementation of proven High-Temperature Gas-cooled Reactors (HTGRs) embodies a viable solution pathway given their inherent, passive safety features and high thermal efficiency. This study provides an overview of the current state of research involving the thermal hydraulics associated with air ingress from a depressurized loss of forced cooling (D-LOFC) in HTGRs. Accurately characterizing and predicting the physical phenomena underlying air ingress is of paramount concern, as the integrity of the fuel and core graphite support structures are threatened by the presence of oxygen. Broadly speaking, the air ingress scenario can be delineated into three main stages: (1) Depressurization, (2) Density-Driven Flow, and (3) Natural Convection. In tandem with the underlying fundamental theory, this review collates and synthesizes the existing body of contemporary research concerning the air ingress scenario following a D-LOFC. As evinced by this review, our current understanding and predictive abilities have benefited from extensive research, predominantly concentrated on the rate of air ingestion into the core. Here, additional research is necessary to holistically capture the phenomenology of an air ingress scenario following a D-LOFC by considering an additional variable: the oxygen content of the ingressing air. The latter variable requires investigation into the complex interactions of the fully integrated system. Additionally, while numerical tools are evolving domestically through the Nuclear Energy Advanced Modeling and Simulation program, a sufficiently validated code remains absent.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Citywide indoor air sampling mirrors wastewater and clinical for environmental surveillance of respiratory viruses

Wastewater surveillance of respiratory pathogens can provide timely estimates of viral activity and disease trends in a population. Indoor air surveillance could be used similarly with some advantages but remains largely unvalidated at the community -scale. Here, an indoor air surveillance program was employed as part of public health environmental surveillance in Chicago, Illinois, USA. Ten air samplers were placed in healthcare and congregate living settings across the city. Weekly air samples were evaluated for influenza A, influenza B, respiratory syncytial virus, and SARS -CoV-2 over two respiratory virus seasons (2023 -2025). Citywide, aggregated air sample positivity and viral load were closely correlated with local clinical case and wastewater surveillance data across all respiratory viruses. Virus trends in air data often preceded clinical and wastewater, although this varied across pathogens and respiratory virus seasons. Further, whole -genome sequencing of SARS -CoV-2 showed close correlation of variant proportions across all datasets. At the building -scale, air samples obtained from a single sampling device provided efficient respiratory virus surveillance, with respiratory pathogen levels mirroring citywide clinical surveillance data. These data demonstrate that air surveillance can provide respiratory virus case and variant trend data at a building or community -scale, serving as an alternative or complementary tool for public health environmental surveillance.

Wilton, Rosemarie

Comparison of multi-stage air treatment process divided by the same temperature and enthalpy difference

The multi-stage air treatment system has been proposed recently, and lower grade chilled/hot water could be used and energy efficiency could be improved. However, it has not been studied which division method of air treatment processes has higher energy efficiency. In this study, the model to calculate the energy consumption of multi-stage air treatment process is introduced, and the effects of two division methods, i.e. multi-stage air treatment process divided by the same temperature difference (ST method) or same enthalpy difference (SE method) between inlet and outlet at each stage, under 9 different air inlet parameters in the 2-stage and 3-stage air treatment processes are analysed and compared. The results show that (1) the system energy consumption of the SE method is generally lower than that of the ST method; (2) there is generally a larger energy consumption reduction rate of SE method when the air relative humidity is 70% compared to relative humidity of 50% and 90%; (3) the difference between ST method and SE method is not great, so both methods can be used for the design of multi-stage treatment system although SE method is normally recommended.

Wang, Wentao

Novel Air System for 300 kW Heavy Duty Fuel Cell

Hydrogen fuel cell powered vehicles for heavy duty trucks is a potential path for reducing heavy duty vehicle emissions in the future. The air handling system delivers the proper amount of air (oxygen) to react with fuel (hydrogen) in the fuel cell to produce power. Air delivery requires significant power and is the largest parasitic loss for a 300 kW fuel cell. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications. The air handling is provided by a twin vortices series (TVS) compressor in addition to adding a TVS expander to recover waste heat energy back into the compressor. The final configuration includes a 600 V, 39 kW motor connected with a single shaft to the compressor and expander. This configuration reduced the total electrical power consumption from 48.6 kW to 37 kW at full load, 27 kW to 9 kW at half load and 0.44 kW to 0.22 kW at idle. The response time requirement was to be less than 2 seconds while the final demonstration yielded 0.62 sec. The study includes additional technologies including water dosing into the compressor, a recuperator and elimination of the intercooler.

Reich, Evan [Eaton Corporation, Southfield, MI (Un

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage

Characterizing Greater Houston's Aerosol by Air Mass During TRACER

During the TRacking Aerosol and Convection interaction ExpeRiment (TRACER), a suite of aerosol and cloud measurements were made using the Texas A&M Rapid Onsite Atmospheric Measurement Van (ROAM-V) mobile instrument platform. Joint ROAM-V/radiosonde deployments focused on sampling polluted marine and continental air masses to understand summertime convection along and across the sea-breeze front as it propagated through Houston. The polluted marine air mass at Seawolf Park, Galveston, TX was defined by two characteristic aerosol populations. Although the background total particle concentrations averaged 2,500 cm −3 , the air mass was also influenced by frequent but irregular periods of ship emission with significantly higher aerosol concentrations at times exceeding 34,000 cm −3 . Ship emission influenced periods, typically lasting <10 min, contained smaller, less hygroscopic particles resulting in a 69% relative decline in cloud condensation nuclei (CCN) activated fraction at 1% supersaturation compared to background periods. Measurements in continental air masses northwest of Houston revealed an average aerosol concentration of 5,208 cm −3 with a κ value near 0.1 reasonably describing the CCN population, independent of particle size. In continental air masses, substantial differences in particle size and CCN activation over small distances (<42 miles between sites) suggest considerable site-to-site variability in addition to the expected day-to-day differences. This small-scale variability makes it difficult to generalize continental air mass aerosol properties. Both coastal and inland locations had effective ice nucleating particles, but inland deployments observed the warmest nucleation temperature at −15.6°C compared to −17.8°C close to the coast. These measurements can reduce uncertainties in regional convection allowing models to improve understanding of aerosol-cloud interactions.

54 ENVIRONMENTAL SCIENCES

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai

EMP - Environmental Radiological Air Monitoring Plan: PNNL Operations in Washington

The Environmental Radiological Air Monitoring Plan (EMP) for Pacific Northwest National Laboratory (PNNL) describes systems/processes/practices related to radiological operations in Richland and Sequim, Washington, that are associated with environmental radiological air monitoring and surveillance activities. The activities described support the lab’s responsibility to maintain safe operations and minimize negative impacts to both onsite and offsite persons and environment. Dose assessments required by regulations and DOE Orders for the public and biota are described. PNNL conducts environmental air surveillance monitoring as part of the PNNL Site Radioactive Air Emissions License (RAEL)-005 for Richland Campus, issued in 2010 with its most recent renewal effective in January 2021. The radioactive air emissions license for the PNNL-Sequim campus (RAEL-014) was issued to the U.S. Department of Energy in 2012 with its most recent renewal effective in January 2023. The EMP is a compilation of the following four documents: - Environmental Radiological Air Monitoring Plan (this main document) (PNNL-20919) - Sampling and Analysis Plan (Attachment 1) (PNNL-20919-1) - Data Management Plan (Attachment 2) (PNNL-20919-2) - Dose Assessment Guidance (Attachment 3) (PNNL-20919-3).

40 CFR 61 Subpart H

Development of SAM Code Capabilities for Safety Analysis of GCR Air-ingress Events

Air-ingress following a depressurized loss-of-forced-cooling (DLOFC) event is a challenging, multiphysics safety scenario for High-Temperature Gas-Cooled Reactors (HTGRs), involving coupled gas composition transport, buoyancy-driven flow redistribution, graphite oxidation, and structural heat-up. Despite its importance — air ingress is a key scenario identified in the PIRT process for the HTGRs — existing system-level safety codes have lacked the integrated capability to simulate the complete event sequence with high confidence. This report documents the development, validation, and demonstration of three new capabilities in the SAM code to address this gap: (1) a multi-component gas mixture flow model with binary diffusion to track the helium-air composition and its effect on system density and flow; (2) a 0-D graphite oxidation model based on the Roes correlation, including oxygen consumption and exothermic heat release; and (3) an isentropic critical flow model for accurate representation of primary system depressurization through a break. These capabilities are validated against two benchmark experiments. The NSTF heavy-gas ingress experiment validates the multi-component flow model: SAM correctly reproduces the rapid buoyancydriven flow stagnation and subsequent natural circulation recovery driven by composition-dependent density changes. The NACOK graphite oxidation experiment validates the oxidation model: SAM predicts a bottom-level graphite weight loss of 25%, in close agreement with the measured 24%, and reproduces the strong axial nonuniformity and block-geometry dependence of oxidation, at a level comparable to the SPECTRA and TINTE codes. The validated capabilities are then exercised together in an integrated, reactor-scale simulation of a DLOFC air-ingress transient in a simplified HTR-PM pebble-bed reactor. In a single calculation spanning approximately 8 days, SAM reproduces the complete accident sequence: rapid depressurization, densityand diffusion-driven air ingress over ˜15 hours, onset of buoyancy-driven natural circulation, exothermic graphite oxidation with a peak fuel temperature at ˜62 hours, and eventual passive cooldown. These results demonstrate that SAM now provides the nuclear community with a preliminarily validated, modern systemlevel tool for HTGR air-ingress safety analysis, filling a recognized capability gap. Future extensions to broaden species tracking, improve oxidation chemistry, and refine the reactor model are discussed.

Yang, Gang

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps

A simple and practical wax-encapsulation method for air-sensitive XAS samples

To facilitate X-ray absorption spectroscopy (XAS) measurements of air-sensitive samples, we present a simple method in which materials are encased in common paraffin wax to protect them from air and moisture. We demonstrate the efficacy of this approach using a highly reducing, air- and moisture-sensitive uranium(III) complex, the tris(amide) U[N(SiMe 3 ) 2 ] 3 (1). When finely dispersed in a boron nitride matrix and subsequently encased in inert paraffin wax, samples of 1 remain stable with no visible or spectroscopic degradation after several days under ambient conditions. The viability of this method for XAS measurements was further evaluated across a series of uranium compounds, ranging from uranyl species to highly air- and moisture-sensitive molecular complexes, at the uranium L 3 -edge. Edge energy determinations were highly reproducible (±0.1 eV between replicates) and, where available, showed excellent agreement with literature values. In conclusion, this low-cost, effective, and versatile method offers a viable solution for XAS studies of air-sensitive compounds and materials.

36 MATERIALS SCIENCE

A Combined Water and CO 2 Direct Air Capture System (Final Technical Report)

The primary objective of the project was to demonstrate the technical and economic performance of a technology that simultaneously captures CO 2 and water from the air – a Hybrid Direct Air Capture system (HDAC). In HDAC, air is passed over water capture section as well as a CO 2 selective sorbent to remove CO 2 from the air stream. Combining potable water generation and CO 2 capture in a single device with the unique energy conserving features of the proposed design enables long-term projected CAPEX under $\$$750/t-CO 2 and levelized cost of capture (LCOC) of $\$$140/t-CO 2 . Project DE-FE-0031970 "A Combined Water and CO 2 Direct Air Capture System" ran for four years and three months from 10/01/2020 to 12/31/2024 for three budget periods and an extension period. The total project budget at completion was $\$$3,534,408 consisting of a $\$$2,680,064 federal share and $\$$854,344 cost share. The pilot plant was successfully designed, engineered, built and commissioned during the initial three budget periods. The plant demonstrated successful water capture during this period, whereas initial CO 2 capture was well below target values. The project team requested an extension period during which alternate materials and beds were evaluated. By the end of the project, both moisture swing adsorption of CO 2 and water capture had successfully been demonstrated at target capture rates making further scale-up of the technology viable.

42 ENGINEERING

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING

A New Framework for the Attribution of Air‐Sea CO 2 Exchange

Abstract The air‐sea transfer of carbon dioxide can be viewed as a dynamic system through which atmospheric and oceanic processes push surface waters away from thermodynamic equilibrium, while diffusive gas transfer pulls them back toward local equilibrium. These push/pull processes drive significant sub‐seasonal, seasonal, and interannual variability in air‐sea carbon fluxes, the quantification of which is critical both for diagnosing the ocean response to fossil fuel emissions and for attempts to mitigate anthropogenic climate disruption through intentional modification of surface ocean biogeochemistry. In this study, we present a new approach for attributing air‐sea carbon fluxes to specific mechanisms. The new framework is first applied to a two‐box ocean nutrient and carbon cycle model as an illustrative example. Next, outputs from a regional eddy‐resolving model of the Southern Ocean are analyzed. The roles of multiple physical and biogeochemical processes are identified. The decomposition of the seasonal air‐sea carbon flux shows the dominant role of biological carbon pumps that are partially compensated by the transport convergence. Finally, the framework is used to diagnose the response to mesoscale iron and alkalinity release, explicitly quantifying transport feedback and eventual impacts on net air‐sea carbon flux. Ocean carbon transport has divergent influences between iron and alkalinity release, due to opposing near‐surface gradients of dissolved inorganic carbon. We suggest that our attribution framework may be a useful analytical technique for monitoring natural ocean carbon fluxes and quantifying the impacts of human intervention on the ocean carbon cycle.

Ito, Takamitsu [School of Earth and Atmospheric Sc

Identification and denoising of radio signals from cosmic-ray air showers using convolutional neural networks

Radio pulses generated by cosmic-ray air showers can be used to reconstruct key properties like the energy and depth of the electromagnetic component of cosmic-ray air showers. Radio detection threshold, influenced by natural and anthropogenic radio background, can be reduced through various techniques. In this work, we demonstrate that convolutional neural networks (CNNs) are an effective way to lower the threshold. We developed two CNNs: a classifier to distinguish radio signal waveforms from background noise and a denoiser to clean contaminated radio signals. Following the training and testing phases, we applied the networks to air-shower data triggered by scintillation detectors of the prototype station for the enhancement of IceTop, IceCube’s surface array at the South Pole. Over a four-month period, we identified 554 cosmic-ray events in coincidence with IceTop, approximately five times more compared to a reference method based on a cut on the signal-to-noise ratio. Comparisons with IceTop measurements of the same air showers confirmed that the CNNs reliably identified cosmic-ray radio pulses and outperformed the reference method. Additionally, we find that CNNs reduce the false-positive rate of air-shower candidates and effectively denoise radio waveforms, thereby improving the accuracy of the power and arrival time reconstruction of radio pulses.

Abbasi, R