Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AgCl”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

Apollo-Soyuz pamphlet no. 6: Cosmic ray dosage

The radiation hazard inside spacecraft is discussed with emphasis on its effects on the crew, biological specimens, and spacecraft instruments. The problem of light flash sensations in the eyes of astronauts is addressed and experiment MA-106 is described. In this experiment, light flashes seen by blindfolded astronauts were counted and high energy cosmic ray intensity in the command module cabin were measured. The damage caused by cosmic ray hits on small living organisms was investigated in the Biostack 3 experiment (MA-107). Individual cosmic rays were tracked through layers of bacterial spores, small seeds, and eggs interleaved with layers of AgCl-crystal wafers, special plastic, and special photographic film that registered each cosmic ray particle passed.

Page, L. W.↗

Diffusion of hydrogen through platinum membranes at high pressures and temperatures

The diffusion of hydrogen through platinum membranes has been measured at 450, 500, 550 and 600 C at 2000 bar pressure, using the hydrogen sensor technique. Ag + AgCl + 3M HCl was the starting solution inside the platinum tube. Hydrogen diffuses out of the platinum tube into a system containing Fe2O3 + Fe3O4 + H2O; that is, a solution with a fixed hydrogen fugacity. After quench, the drop in hydrogen fugacity inside the platinum tube was calculated from measurements of pH and chloride molality. The hydrogen fugacity is initially roughly proportional to the square root of time. Diffusion constants were calculated from these data by numerical integration.

Chou, I.-M.↗

Evaluation of high specific-heat ceramic for regenerator use at temperatures between 2-30 K

Specific heat, thermal conductivity (both in the range 2-30 K), and microhardness data were measured on the ceramics labelled LS-8, LS-8A, and LS-8A doped with CsI, SnCl2, and AgCl. A work hardened sample of LS-8A was also studied in an effort to determine the feasibility of using these types of LS-8 materials to replace Pb spheres in the regenerator of the JPL cryocooler. The LS-8A materials are all more than an order of magnitude harder than Pb, and the dopants do not significantly improve the hardness. However, the SnCl2 dopant has a remarkable effect in improving the specific heat and thermal conductivity of LS-8A. The SnCl2 doping level which maximized the regenerator enthalpy change in going from an unloaded to a loaded condition was found to be 0.2 percent SnCl2 in LS-8A. It was also found that the enthalpy change for a regenerator employing the LS-8A material is more than three times larger than for the Pb spheres case. The use of rods, rather than spheres, of optimally doped LS-8A in regenerators is discussed.

Lawless, W. N.↗

Investigation of stimulated Brillouin scattering switching in mid infrared fibers

Backward stimulated Brillouin scattering (SBS) has been experimentally studied in midinfrared transparent AgCl and KRS-5 fibers. In the present scheme, pump transmission through the fibers and acoustooptic radiative effects are simultaneously observed. The SBS shifted scattered light spectrum is investigated by laser heterodyne spectroscopy using HgCdTe and very fast metal-oxide-metal diode broadband mixers. The results suggest that reflection under high incident laser power departs from simple Fresnel surface reflection.

Yu, Chung↗

Cosmic ray LET spectra and doses on board Cosmos-2044 biosatellite

Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the Linear Energy Transfer (LET) spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (approximately 20 g cm (exp -2) shielding) and outside (1 g cm(exp -2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d (exp -1), respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d(exp -1). The effects of the flight parameters on the total fluence of, and on the dose from the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.

Watts, J. W., Jr.↗

Cosmic ray LET spectra and doses on board Cosmos-2044 biosatellite

Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (approximately 20 g cm-2 shielding) and outside (1 g cm-2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d-1, respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d-1. The effects of the flight parameters on the total fluence of, and on the dose from, the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.

Non-NASA Center↗

Silver Foam A Long-Term Passive Biocide for Potable Water Systems: 2020 Update

A spacecraft water disinfection system suitable for extended length space exploration missions should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically-influenced corrosion. In addition, the system should have minimal maintenance requirements, the effluent should be chemically compatible with all materials in contact with the water, be safe for human consumption, and suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad spectrum biocide and the chosen potable water biocide for future exploration missions. The leading technology for actively dosing silver in future water systems is based on electrolytic production. Several challenges remain with this approach which have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle (NP)/polyurethane (PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2019 International Conference on Environmental Systems (ICES) paper of the same name. In this paper, the technical background and results from the updated silver chloride (AgCl) NP/PU composite foam synthesis and property testing is provided. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Irwin, Tesia D.↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems

A spacecraft water disinfection system suitable for extended length space exploration should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements,should be chemically compatible with all materials in contact with the water, be safe for human consumption, and suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum biocide under consideration as a potable water biocide for future exploration missions. The leading technology for actively dosing silver in future water systems is based on electrolytic production. Several challenges remain with this approach that have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a silver chloride (AgCl) nanoparticle (NP)/polyurethane (PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2019 International Conference on Environmental Systems (ICES) paper number 272.This paper provides the technical background and results from the updated AgClNP/PU composite foam (AgFoam) synthesis and property testing. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia Dawn Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2020 International Conference onEnvironmental Systems (ICES) paper number 128. This paper provides the technical background and performance results from the updated silver chloride (AgCl) NP/PU. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive-Dosing of Biocide in Spacecraft Potable Water Systems – Update 2022

A spacecraft water disinfection system suitable for extended length space exploration should meet a list of requirements. It should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon previously published work. This paper provides the technical background and performance results (wash testing and ongoing long-term silver ion release testing) from the silver chloride (AgCl) NP/PU composite foams. The goal of the project is to develop a stable and reliable passive-dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2023

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2022 International Conference on Environmental Systems (ICES) paper number 97. This paper provides the technical background and performance test results (ongoing long-term silver ion release testing and product variability testing) from the silver chloride (AgCl) NP/PU composite foams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2024

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2023 International Conference on Environmental Systems (ICES) paper number 251. This paper provides the technical background and performance results for the product variability testing and microbial check valve (MCV) testing of the silver chloride (AgCl) NP/PU composite foams, referred to as AgFoams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Reference electrode for electrochemical measurements at high temperatures

A reference electrode which is stable over a wide range of temperatures, pressures and chemical conditions is provided. The subject reference electrode according to the present invention comprises a tubular enclosure composed of quartz having a distal, closed end and a proximal, open end. An insulating ceramic rod is seemingly connected to the opening in the closed distal end of the enclosure to form micro-cracks between the ceramic rod and the quartz enclosure (called a cracked junction, CJ). The CJ gives a very tortuous path for ion conduction from inside the reference electrode (RE) to a working electrode (WE). Inside the tubular enclosure is an electrical lead (e.g., a silver wire) disposed in an electrolyte comprising a mixture of alkaline metal salts (e.g., AgCl and KCl), extending from the electrolyte upward through a sealing means at the proximal end of the quartz enclosure.

Gervasio, Dominic Francis↗

Stabilization of colloidal crystals engineered with nucleic acid

A post-synthetic method for stabilizing colloidal crystals programmed from nucleic acid is disclosed herein. In some embodiments, the method relies on Ag + ions to stabilize the particle-connecting nucleic acid duplexes within the crystal lattice, essentially transforming them from loosely bound structures to ones with very strong interparticle links. In some embodiments, the nucleic acid is DNA. Such crystals do not dissociate as a function of temperature like normal DNA or DNA-interconnected colloidal crystals, and they can be moved from water to organic media or the solid state, and stay intact. The Ag + -stabilization of the nucleic acid (e.g., DNA) bonds is accompanied by a nondestructive contraction of the lattice, and both the stabilization and contraction are reversible with the chemical extraction of the Ag + ions, e.g., by AgCl precipitation with NaCl.

Mirkin, Chad A.↗