Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AgC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Decision-directed automatic gain control for MAPSK systems

An automatic gain control (AGC) loop is presented for use with M-ary amplitude and phase shift keying (MAPSK) systems. The gain control amplifier is regulated by an error signal formed by the difference between the estimated amplitude level and the received amplitude level. The AGC performance is thus independent of the short-term average received signal energy. AGC loop analysis and simulation is presented for M-ary amplitude shift keying and quadrature amplitude shift keying. The AGC is shown to have a negligible degradation on the symbol probability of error for most practical cases. A generalized AGC for an arbitrary MAPSK system is presented.

Weber, W. J., III↗

GD SDR Automatic Gain Control Characterization Testing

The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showi ng how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

Nappier, Jennifer M.↗

GD SDR Automatic Gain Control Characterization Testing

The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showing how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

Nappier, Jennifer M.↗

Automatic gain control

An automatic gain control (AGC), designed to operate with the prototype Loran-C receiver, is described. The device is used to eliminate error which occurs when signals are received at different magnitudes. The automatic gain control is a three transistor circuit which requires a constant dc voltage of 8 volts. Tests conclude that this value may be in the range of 4 to 12 v without change in circuit performance. Two transistors are cascaded to pass and amplify the input signal. Their gain is controlled by a third transistor which itself is controlled by an external AGC voltage between 0 and 8 volts dc. The integrated circuit used is an 8 pin chip, which is a differential cascade amplifier designed for use in communications operating at frequencies from dc to 120 MHz. The integrated circuit was balanced for AGC capabilities, and has a wide operating current range. The maximum input current at pins 1 and 5 is 0.1 mAmps. AGC testing is described.

Roman, J. P.↗

Global weather research

Modeling, prediction, and analysis of global meteorological phenomena influencing the large scale behavior of the atmosphere are summarized. Prediction of global weather phenomena based on satellite data is discussed and models of global phenomena developed. The atmospheric general circulation model (AGCE) is reviewed, axisymmetric flow calculated, and axisymmetric states in cylindrical, spherical, three dimensional, and spin up numerical models for AGCE described. The role of latent heat release in baroclinic waves, latent heat and cyclonic systems, and a theoretical study of baroclinic flow related to the AGCE and the flow regime were studied with a simplified general circulation model. AGCE and the geophysical fluid flow cell (GFFC) instrumentation are discussed. Investigation of solar and planetary convection for GFFC is described. The utilization of satellite cloud observations to diagnose the energy state and transformations in extratropical cyclones is reviewed.

Source record↗

Commutated automatic gain control system

A commutated automatic gain control (AGC) system was designed and built for a prototype Loran C receiver. The receiver uses a microcomputer to control a memory aided phase-locked loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The circuit designed for the AGC is described, and bench and flight test results are presented. The AGC circuit described actually samples starting at a point 40 microseconds after a zero crossing determined by the software lock pulse ultimately generated by a 30 microsecond delay and add network in the receiver front end envelope detector.

Yost, S. R.↗

Commutated automatic gain control system

The commutated automatic gain control (AGC) system was designed and built for the prototype Loran-C receiver is discussed. The current version of the prototype receiver, the Mini L-80, was tested initially in 1980. The receiver uses a super jolt microcomputer to control a memory aided phase loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The AGC control adjusts the level of each station signal, such that the early portion of each envelope rise is about at the same amplitude in the receiver envelope detector.

Yost, S. R.↗

A mixed pseudospectral/finite difference method for a thermally driven fluid in a nonuniform gravitational field

A numerical study of the steady, axisymmetric flow in a heated, rotating spherical shell is conducted to model the Atmospheric General Circulation Experiment (AGCE) proposed to run aboard a later shuttle mission. The AGCE will consist of concentric rotating spheres confining a dielectric fluid. By imposing a dielectric field across the fluid a radial body force will be created. The numerical solution technique is based on the incompressible Navier-Stokes equations. In the method a pseudospectral technique is based on the incompressible Navier-Stokes equations. In the method a pseudospectral technique is used in the latitudinal direction, and a second-order accurate finite difference scheme discretizes time and radial derivatives. This paper discusses the development and performance of this numerical scheme for the AGCE which has been modelled in the past only by pure FD formulations. In addition, previous models have not investigated the effect of using a dielectric force to simulate terrestrial gravity. The effect of this dielectric force on the flow field is investigated as well as a parameter study of varying rotation rates and boundary temperatures. Among the effects noted are the production of larger velocities and enhanced reversals of radial temperature gradients for a body force generated by the electric field.

Macaraeg, M. G.↗

A mixed pseudospectral/finite difference method for a thermally driven fluid in a nonuniform gravitational field

A numerical study of the steady, axisymmetric flow in a heated, rotating spherical shell is conducted to model the Atmospheric General Circulation Experiment (AGCE) proposed to run aboard a later Shuttle mission. The AGCE will consist of concentric rotating spheres confining a dielectric fluid. By imposing a dielectric field across the fluid a radial body force will be created. The numerical solution technique is based on the incompressible Navier-Stokes equations. In the method a pseudospectral technique is used in the latitudinal direction, and a second-order accurate finite difference scheme discretizes time and radial derivatives. This paper discusses the development and performance of this numerical scheme for the AGCE which has been modeled in the past only by pure FD formulations. In addition, previous models have not investigated the effect of using a dielectric force to simulate terrestrial gravity. The effect of this dielectric force on the flow field is investigated as well as a parameter study of varying rotation rates and boundary temperatures. Among the effects noted are the production of larger velocities and enhanced reversals of radial temperature gradients for a body force generated by the electric field.

Macaraeg, M. G.↗

Pointing a ground antenna at a spinning spacecraft using Conscan-simulation results

The results are presented for an investigation of ground antenna pointing errors which are caused by fluctuations of the receiver AGC signal due to thermal noise and a spinning spacecraft. Transient responses and steady-state errors and losses are estimated using models of the digital Conscan (conical scan) loop, the FFT, and antenna characteristics. Simulation results are given for the on-going Voyager mission and for the upcoming Galileo mission, which includes a spinning spacecraft. The simulation predicts a 1 sigma pointing error of 0.5 to 2.0 mdeg for Voyager, assuming an AGC loop SNR of 35 to 30 dB with a scan period varying from 128 to 32 sec, respectively. This prediction is in agreement with the DSS 14 antenna Conscan performance of 1.7 mdeg for 32 sec scans as reported in earlier studies. The simulation of Galileo predicts 1 mdeg error with a 128 sec scan and 4 mdeg with a 32 sec scan under similar AGC conditions.

Mileant, A.↗

Pointing a ground antenna at a spinning spacecraft using conical scan - Simulation results

The results are presented for an investigation of ground antenna pointing errors which are caused by fluctuations of the receiver AGC signal due to thermal noise and a spinning spacecraft. Transient responses and steady-state errors and losses are estimated using models of the digital Conscan (conical scan) loop, the FFT, and antenna characteristics. Simulation results are given for the on-going Voyager mission and for the upcoming Galileo mission, which includes a spinning spacecraft. The simulation predicts a 1 sigma pointing error of 0.5 to 2.0 mdeg for Voyager, assuming an AGC loop SNR of 35 to 30 dB with a scan period varying from 128 to 32 sec, respectively. This prediction is in agreement with the DSS 14 antenna Conscan performance of 1.7 mdeg for 32 sec scans as reported in earlier studies. The simulation of Galileo predicts 1 mdeg error with a 128 sec scan and 4 mdeg with a 32 sec scan under similar AGC conditions.

Mileant, Alexander↗

Design and performance of an Automatic Gain Control system for the High Energy X-Ray Timing Experiment

The High Energy X-Ray Timing Experiment (HEXTE), currently under development for the X-Ray Timing Explorer (XTE) mission, employs a closed loop gain control system to attain 0.5 percent stabilization of each of eight-phoswich detector gains. This Automatic Gain Control (AGC) system utilizes a split window discriminator scheme to control the response of each detector pulse height analyzer to gated Am-241 X-ray events at 60 keV. A prototype AGC system has been implemented and tested within the gain perturbation environment expected to be experienced by the HEXTE instrument in flight. The AGC system and test configuration are described. Response, stability and noise characteristics are measured and compared with theoretical predictions. The system is found to be generally suitable for the HEXTE application.

Pelling, Michael R.↗

Low phase-shift amplifier

Single-stage MOSFET amplifier is described which is identical to standard neutralized amplifier except that neutralization provided by broadband transformer is applied to AGC gate instead of signal gate. Neutralization of drain-to-control gate capacity minimizes the phase change induced by variation in AGC.

Lutes, G. F.↗

Burst-error characteristics of the equatorial transionospheric channel

Analyses of AGC analog data from the Small Astronomy Satellite (SAS) at VHF (136 MHz) have shown amplitude fluctuations in the signals received at several equatorial tracking sites operated by NASA. Errors in data are shown to increase markedly for nighttime satellite passes around the periods of the two equinoxes as compared to the errors observed during other periods. Qualitative and quantitative correlations are established between the ionospheric scintillation phenomenon and the occurrence of errors. Strong time and geographic cause-and-effect relationships are established by determining the statistical correlation between scintillation indices and bit error rates. Detailed analyses of the AGC fading statistics and the fine grain error statistics, such as the block-error distribution and the bit-error autocorrelation function, establish the strong correlation between deep fades and their effects on the burst error structure associated with the transionospheric channel and the communication receiver being employed.

Blank, H. A.↗

The estimation of pointing angle and normalized surface scattering cross section from GEOS-3 radar altimeter measurements

The statistical error of the pointing angle estimation technique is determined as a function of the effective receiver signal to noise ratio. Other sources of error are addressed and evaluated with inadequate calibration being of major concern. The impact of pointing error on the computation of normalized surface scattering cross section (sigma) from radar and the waveform attitude induced altitude bias is considered and quantitative results are presented. Pointing angle and sigma processing algorithms are presented along with some initial data. The intensive mode clean vs. clutter AGC calibration problem is analytically resolved. The use clutter AGC data in the intensive mode is confirmed as the correct calibration set for the sigma computations.

Brown, G. S.↗

Digital automatic gain control

Performance analysis, used to evaluated fitness of several circuits to digital automatic gain control (AGC), indicates that digital integrator employing coherent amplitude detector (CAD) is best device suited for application. Circuit reduces gain error to half that of conventional analog AGC while making it possible to automatically modify response of receiver to match incoming signal conditions.

Uzdy, Z.↗

Learning guide for the terminal configured vehicle advanced guidance and control system mode select panel

This learning guide is designed to assist pilots in taking the PLATO presimulator training course on the advanced guidance and control system mode select panel. The learning guide is divided into five sections. The first section, the introduction, presents the course goals, prerequisites, definition of PLATO activities, and a suggested approach to completing the course. The remaining four sections present the purpose, learning activities and summary of each lesson of the AGCS PLATO course, which consists of (1) AGCS introduction; (2) lower order modes; (3) higher order modes; and (4) an arrival route exercise.

Anderson, M. A.↗

Feasibility study: Atmospheric general circulation experiment, volume 1

The atmospheric general circulation experiment (AGCE) uses a rotating fluid flow cell assembly. The key technical areas affecting the feasibility of the design and operation of the AGCE are investigated. The areas investigated include materials for the flow cell assembly, thermal design, high voltage power supply design, effective retrieval and handling of experiment data and apparatus configuration. Several materials, DMSO and m-tolunitrile, were selected as candidate fluids for the flow cell principally for their high dielectric constant which permits the high voltage power supply design to be held to 15 kV and still simulate terrestrial gravity. Achievement of a low dissipation factor in the fluid to minimize internal heating from the applied electrical field depends strongly on purification and handling procedures. The use of sapphire as the outer hemisphere for the flow cell provides excellent viewing conditions without a significant impact on attaining the desired thermal gradients. Birefringent effects from sapphire can be held to acceptably low limits. Visualization of flow fluid is achieved through the motion of a dot matrix formed by photochromic dyes. Two dyes found compatible with the candidate fluids are spiropyran and triarylmethane. The observation of the dot motion is accomplished using a flying spot scanner.

Homsey, R. J.↗