Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Activity detect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Methods of expressing and detecting activity of expansin in plant cells

A method of expressing heterologous expansin in a plant cell is provided where a nucleic acid molecule encoding expansin is introduced into the plant cell and in an embodiment is operably linked to a promoter preferentially expressing in the seed tissue of the plant, and in another embodiment is linked to a promoter preferentially expressing in the embryo tissue of the seed. An embodiment provides the nucleic acid molecule is operably linked to a second nucleic acid molecule that directs expression to the endoplasmic reticulum, vacuole or cell wall. Plants and plant parts expressing expansin are provided. An assay for detection of expansin activity is also provided.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexed Toxin Activity Detection

There is a need for field forward biothreat detection methods for highly lethal marine toxins, such as conotoxins, to protect the warfighter and civilians in contested environments. These toxins arise from harmful algal blooms which impact the warfighter, pets, and civilians. The need for detection platforms that can be fielded on drones or unmanned vehicles is paramount to successful biothreat detection to serve as an early warning system for those impacted in these environments.

59 BASIC BIOLOGICAL SCIENCES↗

An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays

Active matrix flat-panel imager (AMFPI) technology is being employed for an increasing variety of imaging applications. An important element in the adoption of this technology has been significant ongoing improvements in optical signal collection achieved through innovations in indirect detection array pixel design. Such improvements have a particularly beneficial effect on performance in applications involving low exposures and/or high spatial frequencies, where detective quantum efficiency is strongly reduced due to the relatively high level of additive electronic noise compared to signal levels of AMFPI devices. In this article, an examination of various signal properties, as determined through measurements and calculations related to novel array designs, is reported in the context of the evolution of AMFPI pixel design. For these studies, dark, optical, and radiation signal measurements were performed on prototype imagers incorporating a variety of increasingly sophisticated array designs, with pixel pitches ranging from 75 to 127 {mu}m. For each design, detailed measurements of fundamental pixel-level properties conducted under radiographic and fluoroscopic operating conditions are reported and the results are compared. A series of 127 {mu}m pitch arrays employing discrete photodiodes culminated in a novel design providing an optical fill factor of {approx}80% (thereby assuring improved x-ray sensitivity), and demonstrating low dark current, very low charge trapping and charge release, and a large range of linear signal response. In two of the designs having 75 and 90 {mu}m pitches, a novel continuous photodiode structure was found to provide fill factors that approach the theoretical maximum of 100%. Both sets of novel designs achieved large fill factors by employing architectures in which some, or all of the photodiode structure was elevated above the plane of the pixel addressing transistor. Generally, enhancement of the fill factor in either discrete or continuous photodiode arrays was observed to result in no degradation in MTF due to charge sharing between pixels. While the continuous designs exhibited relatively high levels of charge trapping and release, as well as shorter ranges of linearity, it is possible that these behaviors can be addressed through further refinements to pixel design. Both the continuous and the most recent discrete photodiode designs accommodate more sophisticated pixel circuitry than is present on conventional AMFPIs - such as a pixel clamp circuit, which is demonstrated to limit signal saturation under conditions corresponding to high exposures. It is anticipated that photodiode structures such as the ones reported in this study will enable the development of even more complex pixel circuitry, such as pixel-level amplifiers, that will lead to further significant improvements in imager performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VARIABILITY AND MULTIWAVELENGTH-DETECTED ACTIVE GALACTIC NUCLEI IN THE GOODS FIELDS

We identify 85 variable galaxies in the GOODS North and South fields using five epochs of Hubble Space Telescope Advance Camera for Survey V-band (F606W) images spanning 6 months. The variables are identified through significant flux changes in the galaxy's nucleus and represent {approx}2% of the survey galaxies. With the aim of studying the active galaxy population in the GOODS fields, we compare the variability-selected sample with X-ray and mid-IR active galactic nucleus (AGN) candidates. Forty-nine percent of the variables are associated with X-ray sources identified in the 2Ms Chandra surveys. Twenty-four percent of X-ray sources likely to be AGNs are optical variables and this percentage increases with decreasing hardness ratio of the X-ray emission. Stacking of the non-X-ray-detected variables reveals marginally significant soft X-ray emission. Forty-eight percent of mid-IR power-law sources are optical variables, all but one of which is also X-ray detected. Thus, about half of the optical variables are associated with either X-ray or mid-IR power-law emission. The slope of the power-law fit through the Spitzer IRAC bands indicates that two-thirds of the variables have BLAGN-like spectral energy distributions. Among those galaxies spectroscopically identified as AGNs, we observe variability in 74% of broad-line AGNs and 15% of NLAGNs. The variables are found in galaxies extending to z{approx} 3.6. We compare the variable galaxy colors and magnitudes to the X-ray and mid-IR sample and find that the non-X-ray-detected variable hosts extend to bluer colors and fainter intrinsic magnitudes. The variable AGN candidates have Eddington ratios similar to those of X-ray-selected AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting active comets with SDSS

Using a sample of serendipitously discovered active comets in the Sloan Digital Sky Survey (SDSS), we develop well-controlled selection criteria for greatly increasing the efficiency of comet identification in the SDSS catalogs. After follow-up visual inspection of images to reject remaining false positives, the total sample of SDSS comets presented here contains 19 objects, roughly one comet per 10 million other SDSS objects. The good understanding of selection effects allows a study of the population statistics, and we estimate the apparent magnitude distribution to r {approx} 18, the ecliptic latitude distribution, and the comet distribution in SDSS color space. The most surprising results are the extremely narrow range of colors for comets in our sample (e.g. root-mean-square scatter of only {approx}0.06 mag for the g-r color), and the similarity of comet colors to those of jovian Trojans. We discuss the relevance of our results for upcoming deep multi-epoch optical surveys such as the Dark Energy Survey, Pan-STARRS, and the Large Synoptic Survey Telescope (LSST), and estimate that LSST may produce a sample of about 10,000 comets over its 10-year lifetime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active Detection and Imaging of Nuclear Materials with High-Brightness Gamma Rays

A Compton scattering {gamma}-ray source, capable of producing photons with energies ranging from 0.1 MeV to 0.9 MeV has been commissioned and characterized, and then used to perform nuclear resonance fluorescence (NRF) experiments. The performances of the two laser systems (one for electron production, one for scattering), the electron photoinjector, and the linear accelerator are also detailed, and {gamma}-ray results are presented. The key source parameters are the size (0.01 mm{sup 2}), horizontal and vertical divergence (6 x 10 mrad{sup 2}), duration (10 ps), spectrum and intensity (10{sup 5} photons/shot). These parameters are summarized by the peak brightness, 1.5 x 10{sup 15} photons/mm{sup 2}/mrad{sup 2}/s/0.1% bandwidth, measured at 478 keV. Additional measurements of the flux as a function of the timing difference between the drive laser pulse and the relativistic photo-electron bunch, {gamma}-ray beam profile, and background evaluations are presented. These results are systematically compared to theoretical models and computer simulations. NRF measurements performed on {sup 7}Li in LiH demonstrate the potential of Compton scattering photon sources to accurately detect isotopes in situ.

42 ENGINEERING↗

X-ray detected active galactic nuclei in dwarf galaxies at 0 < z < 1

We present a sample of accreting supermassive black holes (SMBHs) in dwarf galaxies at z<1. We identify dwarf galaxies in the NEWFIRM Medium Band Survey with stellar masses of M{sub ⋆}<3×10{sup 9} M{sub ⊙} that have spectroscopic redshifts from the DEEP2 survey and lie within the region covered by deep (flux limit of ∼5×10{sup −17}--6×10{sup −16} erg cm{sup −2} s{sup −1}) archival Chandra X-ray data. From our sample of 605 dwarf galaxies, 10 exhibit X-ray emission consistent with that arising from active galactic nucleus (AGN) activity. If black-hole mass scales roughly with stellar mass, then we expect that these AGNs are powered by SMBHs with masses of ∼10{sup 5}--10{sup 6} M{sub ⊙} and typical Eddington ratios of ∼5%. Furthermore, we find an AGN fraction consistent with extrapolations of other searches of ∼0.6%--3% for 10{sup 9} M{sub ⊙}⩽M{sub ⋆}⩽3×10{sup 9} M{sub ⊙} and 0.1<z<0.6. Our AGN fraction is in good agreement with a semi-analytic model, suggesting that, as we search larger volumes, we may use comparisons between observed AGN fractions and models to understand seeding mechanisms in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Long Range Active Detection of HEU Based on Thermal Neutron Multiplication

We report on the results of measurements of proton irradiation on a series of targets at Brookhaven National Laboratory’s (BNL) Alternate Gradient Synchrotron Facility (AGS), in collaboration with LANL and SNL. We examined the prompt radiation environment in the tunnel for the DTRA-sponsored series (E 972), which investigated the penetration of air and subsequent target interaction of 4 GeV proton pulses. Measurements were made by means of an organic scintillator with a 500 MHz bandwidth system. We found that irradiation of a depleted uranium (DU) target resulted in a large gamma-ray signal in the 100-500 µsec time region after the proton flash when the DU was surrounded by polyethylene, but little signal was generated if it was surrounded by boron-loaded polyethylene. Subsequent Monte Carlo (MCNPX) calculations indicated that the source of the signal was consistent with thermal neutron capture in DU. The MCNPX calculations also indicated that if one were to perform the same experiment with a highly enriched uranium (HEU) target there would be a distinctive fast neutron yield in this 100-500 µsec time region from thermal neutron-induced fission. The fast neutrons can be recorded by the same direct current system and differentiated from gamma ray pulses in organic scintillator by pulse shape discrimination.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Malicious activity detection in a memory

A method and apparatus for monitoring a volatile memory in a computer system. Samples of compressed data from locations in the volatile memory in the computer system are read. Data in the volatile memory is reconstructed using the samples of compressed data. The data is an image of the volatile memory. The image enables determining whether an undesired process is present in the volatile memory.

Wheeler, Jason W.↗

A cell-based Papain-like Protease (PLpro) activity assay for rapid detection of active SARS-CoV-2 infections and antivirals

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its variants are a continuous threat to human life. An urgent need remains for simple and fast tests that reliably detect active infections with SARS-CoV-2 and its variants in the early stage of infection. Here we introduce a simple and rapid activity-based diagnostic (ABDx) test that identifies SARS-CoV-2 infections by measuring the activity of a viral enzyme, Papain-Like protease (PLpro). The test system consists of a peptide that fluoresces when cleaved by SARS PLpro that is active in crude, unprocessed lysates from human tongue scrapes and saliva. Test results are obtained in 30 minutes or less using widely available fluorescence plate readers, or a battery-operated portable instrument for on-site testing. Proof-of-concept was obtained in a study on clinical specimens collected from patients with COVID-19 like symptoms who tested positive (n = 10) or negative (n = 10) with LIAT RT-PCR using nasal mid turbinate swabs. When saliva from these patients was tested with in-house endpoint RT-PCR, 17 were positive and only 5 specimens were negative, of which 2 became positive when tested 5 days later. PLpro activity correlated in 17 of these cases (3 out of 3 negatives and 14 out of 16 positives, with one invalid specimen). Despite the small number of samples, the agreement was significant (p value = 0.01). Two false negatives were detected, one from a sample with a late Ct value of 35 in diagnostic RT-PCR, indicating that an active infection was no longer present. The PLpro assay is easily scalable and expected to detect all viable SARS-CoV-2 variants, making it attractive as a screening and surveillance tool. Additionally, we show feasibility of the platform as a new homogeneous phenotypic assay for rapid screening of SARS-CoV-2 antiviral drugs and neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗

Special Nuclear Material Detection and Monitoring by Environmental Activation Products Detection

Through a series of measurements with a high purity germanium detector, we have established that the past presence of neutron emitting material can be detected by the decay of activation products in aluminum containers, tungsten shielding, and concrete floors even several days after last exposure. The time since last exposure can also be estimated by the gamma-ray detection rate. These findings may lead to interesting new CONOPS in the detection of illicit SNM or the verification of the absence (or presence) of SNM containing objects in facilities and/or transit even after the material has been removed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanopore Activity Assays for Detection of Biomarker Protease Activity: Design and Testing of Substrates for Both Nanopore Sequencing and PCR-Based Detection Methods

The work performed in this project has demonstrated the ability to construct proteolytic enzyme substrates that are PCR and sequencing-readable reporter molecules. Specifically, the goal was to detect those reporter molecules via PCR and Oxford Nanopore Technologies MinION sequencing methods following exposure to the biomarker protease thrombin. The assay development focused on binding the constructed peptide-oligonucleotide chimera to immobilized streptavidin. The action of thrombin on the peptide portion of the molecule released the oligonucleotide for detection. Detection of protease activity was demonstrated in a concentration-dependent manner using MALDI-MS, RT-PCR and DNA sequencing. Additional steps to remove background release of reporter molecules during the assay was used to improve the difference in detected oligonucleotide reporter following protease activity. Additional steps in assay development will be to (1) test the assay in an appropriate matrix, (2) investigate detection using additional DNA sequencing platforms and (3) demonstrate multiplexed detection of multiple protease markers in a single reaction.

59 BASIC BIOLOGICAL SCIENCES↗

PARAMETER-FREE AUTOMATIC SOLAR ACTIVE REGION DETECTION BY HERMITE FUNCTION DECOMPOSITION

We present a new method for the automated detection of sunspots and active regions (ARs) from full-disk observations of the photospheric Stokes vector. The algorithm relies on a Hermite function decomposition of observed Stokes polarization profiles as a function of position on the solar disk. This approach is unique in that it requires no user-defined tunable parameters, like intensity or magnetic field thresholds, and utilizes no information traditionally exploited by other detection schemes to signal the presence of an AR. It is truly a black-box approach, utilizing a self-consistent statistical analysis of the Hermite coefficients. We present the method and show the results of its application to Synoptic Optical Long-term Investigations of the Sun Vector Spectromagnetograph full-disk observations. Detection efficiency is presented for a one-month time series of daily photospheric observations, and we derive a skill-score for the method during this time period.

79 ASTRONOMY AND ASTROPHYSICS↗

Groundwater Monitoring and Control Before Decommissioning of the Research Reactor VVR-S from Magurele-Bucharest

The research reactor type VVR-S (tank type, water is cooler, moderator and reflector, thermal power- 2 MW, thermal energy- 9. 52 GW d) was put into service in July 1957 and, in December 1997 was shout down. In 2002, Romanian Government decided to put the research reactor in the permanent shut-down in order to start the decommissioning. This nuclear facility was used in nuclear research and radioisotope production for 40 years, without events, incidents or accidents. Within the same site, in the immediate vicinity of the research reactor, there are many other nuclear facilities: Radioactive Waste Treatment Plant, Tandem Van der Graaf heavy ions accelerator, Cyclotron, Industrial Irradiator, Radioisotope Production Center. The objectives of this work were dedicated on the water underground analyses described in the following context: - presentation of the approaches in planning the number of drillings, vertical soil profiles (characteristics, analyses, direction of the flow of underground water, uncertainties in measurements); - presentation of the instrumentation used in analyses of water, soil and vegetation samples - analyses and final conclusions on results of the measurements; - comparison of the results of measurements on underground water from drillings with the measurements results on samples from the town and the system of drinking water - supplied from the second level of underground water. According to the analysis, in general, no values higher than the Minimum Detectable Activity were detected in water samples (MDA) for Pb{sup 212}, Bi{sup 214}, Pb{sup 214}, Ac{sup 228}, but situated under values foreseen in drinking water. Distribution of Uranium As results of the Uranium determination, values higher than 0,004 mg/l (4 ppb) were detected, values that represent the average contents in the underground water. The higher values, 2-3 times higher than background, were detected in the water from the drillings F15, F12, F5, F13, drillings located between RWTP (Radioactive Waste Treatment Plant) - the 300 m{sup 3} tanks and the Spent Filters Storage (SFS). At south of this area, on the leaking direction of the underground water layer, in the drillings F1, F2, F3, F18 and at east, in F6, F7, the natural Uranium values are within the background for the underground-water. Distribution of Radon For the Radon determination with RAD 7 equipment, water samples were taken from the same piezo-metrical drilling, 2 or 4 times during of six months period, and then, the average contents were calculated, which varied between 0,35 - 2,1 Bq/l. The values higher than 1,1 -1,2 Bq/l were detected in the water taken from the drillings located in the northern part (F10, F11) and in the eastern part (F6, F8) of the Institute fences (around of the radioactive waste storage facilities). The concentrations of 0,3 - 0,5 Bq/l are in the underground-water layer 'intercepted' by the piezo-metrical drillings (F1, F2, F3) located near the Nuclear Reactor. Concentration of heavy metals: 0.04-0.08 mg/l Pb in F5, F14, F7, F8 exceeding MCA-Maximum Admissible Concentration (0.01 mg/l) for Pb, and for Zn in F5, F7, F8, F14 are 0.2-0.5 mg/l situated under MCA , and 0.18 mg/l in F18, in accordance with tendency of decreasing of concentration of contaminants. After 50 years of deploying nuclear activities on the site the underground water quality is in very good condition. Taking into consideration the direction of the underground water flow, it results that, only in the area of underground pipe, around of the research reactor and radioactive waste treatment plant, the quality of water is influenced, and remediation actions are not necessary. Based on measurements executed in F18, the water quality is the same with any other part of the region. During the decommissioning of the Research Reactor, the samples from 18 drillings will be analysed monthly, and the contents of the heavy metals, Pb and Zn, will be monitored carefully, together with all the factors: air, soil, vegetation, subsoil, water surface and underground water. A great attention will be paid to the dismantlement of the underground structures, the 30 m{sup 3} tank, that collects all the liquid radioactive waste from the reactor, the pipes that connects this tank to the other two 300 m{sup 3} tanks, from RWTP, the ventilation ducts between the Spent Filters Storage and reactor's stack, in order to prevent contamination of surface and underground water. Engineering Absorbent Barriers will be used both for hydrophilic substances and for hydrophobic substances, tents will be used for preventing the spread of possible contaminants from the pipes and tanks, owing to the precipitation or wind, and the tanks and pipes will be drained to eliminate the spills. Since we are dealing with a multinuclear facility site, the on site and off site Monitoring Program of Institute will be properly upgraded, taking into account the values of the derived emission limit approved by Regulatory Body, before, during and after the completion of the works with impact on underground water. In another work will be presented radiological map of land associated of decommissioning project (on surface, at 0.15 m and 0.30 m in depth of soil) and estimation of migration rate in soil up to ground water level. Applying these measures, taking account of the radiological status at the beginning of the project, will mean savings and a good protection of the environment in completing the decommissioning project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗