Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Active Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Spatio-temporal patterning of extensile active stresses in microtubule-based active fluids

Abstract Microtubule-based active fluids exhibit turbulent-like autonomous flows, which are driven by the molecular motor powered motion of filamentous constituents. Controlling active stresses in space and time is an essential prerequisite for controlling the intrinsically chaotic dynamics of extensile active fluids. We design single-headed kinesin molecular motors that exhibit optically enhanced clustering and thus enable precise and repeatable spatial and temporal control of extensile active stresses. Such motors enable rapid, reversible switching between flowing and quiescent states. In turn, spatio-temporal patterning of the active stress controls the evolution of the ubiquitous bend instability of extensile active fluids and determines its critical length dependence. Combining optically controlled clusters with conventional kinesin motors enables one-time switching from contractile to extensile active stresses. These results open a path towards real-time control of the autonomous flows generated by active fluids.

36 MATERIALS SCIENCE↗

PowerModel-AI: A First On-the-Fly Machine-Learning Predictor for AC Power Flow Solutions

The real-time creation of machine-learning models via active or on-the-fly learning has attracted considerable interest across various scientific and engineering disciplines. These algorithms enable machines to build models autonomously while remaining operational. Through a series of query strategies, the machine can evaluate whether newly encountered data fall outside the scope of the existing training set. In this study, we introduce PowerModel-AI, an end-to-end machine learning software designed to accurately predict AC power flow solutions. We present detailed justifications for our model design choices and demonstrate that selecting the right input features effectively captures load flow decoupling inherent in power flow equations. Our approach incorporates on-the-fly learning, where power flow calculations are initiated only when the machine detects a need to improve the dataset in regions where the model’s suboptimal performance is based on specific criteria. Otherwise, the existing model is used for power flow predictions. This study includes analyses of five Texas A&M synthetic power grid cases, encompassing the 14-, 30-, 37-, 200-, and 500-bus systems. The training and test datasets were generated using PowerModels.jl, an open-source power flow solver/optimizer developed at Los Alamos National Laboratory, NM, USA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through various methods, two of them being thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine thermal quadrant powers. The N-16 system utilizes a beta detector that outputs Nitrogen activation levels to calculate lobe power through an algorithm called Lobe Power Calculation and Indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. These correct indications are crucial for maintaining safety limits because operators rely on this information for decision making. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have increased the accuracy of power readings by making the system more dynamic. The new proposed coefficient and multiplier method implements a cycle specific and physics-based model intended for changing coefficients during operation. This calibration experiment focused on power splitting, outer shim and neck shim, as well as fuel burning into the reactor digital acquisition system (RDAS) weighting factors. Results demonstrated that the physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with the FFTF LOFWOS Tests #10-12

The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. The results of modeling and simulation of LOFWOS Tests #10, #11, and #12 are presented in this report to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. These three tests did not use the primary loop pony motors and thus transitioned to natural circulation flow rates from varying initial power levels. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project (CRP) for benchmark analysis of the FFTF LOFWOS Test #13. The SAS4A/SASSYS-1 model originally developed for the CRP has been extended to include LOFWOS Tests #10-12 and modernized to utilize new code features and modeling practices. Predicted results from SAS4A/SASSYS-1 were compared to measured test data and differences were investigated. Overall, it was concluded that, for LOFWOS Tests #10-12, there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution

DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flow battery flow field having volume that is function of power parameter, time parameter and concentration parameter

A flow battery includes a cell that has first and second flow fields spaced apart from each other and an electrolyte separator layer. A supply/storage system is external of the cell and includes first and second vessels fluidly connected with the first and second flow fields, and first and second pumps configured to selectively move first and second fluid electrolytes between the vessels and the first and second flow fields. The flow fields each have an electrochemically active zone that is configured to receive flow of the fluid electrolytes. The electrochemically active zone has a total open volume that is a function of at least one of a power parameter of the flow battery, a time parameter of the pumps and a concentration parameter of the fluid electrolytes.

Smeltz, Andrew↗

Molten Chloride Thermophysical Properties, Chemical Optimization, and Purification

Next-generation concentrating solar power (CSP) technology requires high-temperature heat-transfer fluids and thermal energy storage that can operate in the temperature range of 500°–720°C. This high temperature demands a new chemistry for the heat-transfer fluids that must have high-temperature thermal and chemical stabilities, high energy density, and low corrosion rate on metallic materials used in the heat exchangers, piping, and thermal energy storage tanks. A ternary MgCl 2 -KCl-NaCl chloride-salt system has been proposed to achieve such goals, given its high-temperature thermal stability. The chloride-salt-based systems have been used by the metallurgy industry as the electrolyte to electrolytically extract metallic magnesium. They have also attracted attentions from the nuclear industry for developing the molten salt fast reactors that can operate at close to atmospheric pressure and at higher temperature than traditional light-water reactors. However, the corrosion properties of the ternary salt are not well known. The corrosion mechanism is believed to be correlated to the presence of MgOHCl impurity at the operation temperature. MgOHCl is fundamentally caused by the hygroscopic nature of the MgCl 2 component. Therefore, the first key objective of this project is to understand the nature of the corrosiveness of the ternary chloride-salt system and its prevention by designing new lab-scale purification processes. Because of its importance, a working group called the Chloride Salt Collective across multiple U.S. Department of Energy national laboratories is established to gain experimental agreement on the corrosion behaviors. In addition, water generation during salt dehydration could lead to highly corrosive HCl/water mixture via a hydrolysis process between water and anhydrous MgCl 2 or MgCl 2 hydrates. MgOHCl will eventually be converted to MgO particulates regardless of the chemical path chosen (i.e., by thermal decomposition, chemical purification with an active metal, or electrochemical purification utilizing the reduction power of electron flows). Large MgO particles with high hardness can wear out bearing and bushing and even clog the delicate channels in the primary heat exchanger. Because of this, a second objective is to understand the chemistry behind salt purification and transfer the scientific understanding to a set of engineering know-how for large-scale salt melter design. Because there is limited information on the thermophysical properties and the sensitivity of these properties around the targeted salt composition, a third objective is to measure thermophysical properties relevant to system and component design and support Topic 1 Liquid Pathway development. For example, composition shift due to salt reaction with water can be a potential issue because it can lead to changes of thermophysical properties, such as (1) melting point (or freeze point), which can jeopardize safe operation of the supercritical CO 2 power cycle proposed for next-generation CSP, and (2) heat capacity and density, which can decrease the overall power-generation capability of the plants. The value of the thermal conductivity of the selected salt composition is also a critical criterion for the solar receiver design.

14 SOLAR ENERGY↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Rectified Rotational Dynamics of Mobile Inclusions in Two-Dimensional Active Nematics

We investigate the dynamics of mobile inclusions embedded in 2D active nematics. The interplay between the inclusion shape, boundary-induced nematic order, and autonomous flows powers the inclusion motion. Disks and achiral gears exhibit unbiased rotational motion, but with distinct dynamics. In comparison, chiral gear-shaped inclusions exhibit long-term rectified rotation, which is correlated with dynamics and polarization of nearby +1/2 topological defects. Furthermore, the chirality of defect polarities and the active nematic texture around the inclusion correlate with the inclusion’s instantaneous rotation rate. Inclusions provide a promising tool for probing the rheological properties of active nematics and extracting ordered motion from their inherently chaotic motion.

36 MATERIALS SCIENCE↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗